EN 12421:1998
(Main)Magnesium and magnesium alloys - Unalloyed magnesium
- BACK
- 21-Apr-1998
- 07-Mar-2017
- 77.120.20
- CEN/TC 190
Magnesium and magnesium alloys - Unalloyed magnesium
This European standard specifies the chemical composition of cast unalloyed magnesium. It specifies classification, designation and marking.
Magnesium und Magnesiumlegierungen - Reinmagnesium
Diese Europäische Norm legt die chemische Zusammensetzung von Reinmagnesiumguß sowie die Klassifizierung, Bezeichnung und Kennzeichnung fest.
Magnésium et alliages de magnésium - Magnésium non allié
La présente norme européenne spécifie la composition chimique du magnésium non allié moulé. Elle en spécifie la classification, la désignation et le marquage.
Magnezij in magnezijeve zlitine - Nelegirani magnezij
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Magnezij in magnezijeve zlitine - Nelegirani magnezijMagnesium und Magnesiumlegierungen - ReinmagnesiumMagnésium et alliages de magnésium - Magnésium non alliéMagnesium and magnesium alloys - Unalloyed magnesium77.120.20Magnezij in magnezijeve zli
...
This May Also Interest You
This European Standard specifies the grades and the corresponding requirements for magnesium alloys for cast anodes.
This European Standard specifies 2 groups of cast magnesium alloy grades by a classification based on chemical composition. The first group deals with magnesium alloy ingots for anodes. The second group deals with magnesium alloy anode castings.
This European Standard specifies chemical composition, designation, testing and inspection documentation.
This European Standard does not cover technical delivery conditions for magnesium alloy anode castings (see EN 1559-1 [3] and EN 1559-5 [4]).
- Standard18 pagesEnglish languagesale 10% offe-Library read for×1 day
- 05-Sep-2017
- 77.120.20
- 77.150.10
- 77.150.20
- CEN/TC 190
This European Standard specifies the grades and corresponding requirements for cast unalloyed magnesium.
This European Standard specifies the chemical composition, designation, testing, marking and inspection documentation.
- Standard11 pagesEnglish languagesale 10% offe-Library read for×1 day
- 07-Mar-2017
- 77.120.20
- CEN/TC 190
This European Standard specifies the grades and the corresponding requirements for magnesium alloys for cast anodes.
This European Standard specifies 2 groups of cast magnesium alloy grades by a classification based on chemical composition. The first group deals with magnesium alloy ingots for anodes. The second group deals with magnesium alloy anode castings.
This European Standard specifies chemical composition, designation, testing and inspection documentation.
This European Standard does not cover technical delivery conditions for magnesium alloy anode castings (see EN 1559-1 [3] and EN 1559-5 [4]).
- Standard18 pagesEnglish languagesale 10% offe-Library read for×1 day
- 05-Sep-2017
- 77.120.20
- 77.150.10
- 77.150.20
- CEN/TC 190
This European Standard specifies the grades and corresponding requirements for cast unalloyed magnesium.
This European Standard specifies the chemical composition, designation, testing, marking and inspection documentation.
- Standard11 pagesEnglish languagesale 10% offe-Library read for×1 day
- 07-Mar-2017
- 77.120.20
- CEN/TC 190
This document specifies the minimum safety characteristics required for the design, materials, manufacture and testing of inflatable boats and rigid inflatable boats with a length of the hull LH in accordance with ISO 8666 less than 8 m with a motor power rating of 15 kW and greater.
This document is applicable to the following types of boats intended for use within the operating temperatures of –20 °C to +60 °C:
— Type VII: Powered boats, fitted with a buoyancy tube on the port and starboard sides, suitable for navigation in conditions of design categories C and D.
— Type VIII: Powered boats, fitted with a buoyancy tube on the port and starboard sides, suitable for navigation in conditions of design category B.
This document excludes single-chambered boats and boats with tubes made from unsupported materials, and does not apply to aquatic toys and inflatable liferafts.
Boats with tubes made from aluminium, roto-moulded polyethylene, fibre reinforced plastic or other rigid materials are excluded from this document.
- Draft34 pagesEnglish languagesale 10% offe-Library read for×1 day
- 14-May-2024
- 47.080
- 2013/53/EU
- M/542
- CEN/TC 464
This document specifies minimum requirements concerning material, design, construction and workmanship, manufacturing processes and testing of refillable transportable welded carbon steel gas cylinders of water capacities up to and including 150 l for compressed, liquefied and dissolved gases.
For acetylene service, additional requirements for the cylinder and basic requirements for the porous material are given in EN ISO 3807. For cylinder shells for acetylene service manufactured from high frequency induction (HFI) welded steel tubes by spinning of the end, the requirements are given in Annex A.
This document is primarily applicable to industrial gases other than LPG but can also be applied for LPG. However for dedicated LPG cylinders, see EN 1442.
- Draft42 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies a measurement method based on an automatic method for determination of the mass concentration of formaldehyde in ducts and stacks emitting to the atmosphere. It specifies the sampling and gas conditioning system. Furthermore, it specifies the characteristics to be determined and the performance criteria to be fulfilled by portable automated measuring systems (P-AMS) using appropriate techniques to measure formaldehyde.
This method is intended for intermittent monitoring of formaldehyde emissions as well as for the calibration and validation of automated formaldehyde measuring systems.
The analyser is calibrated using test gases produced by a test gas generator.
- Draft41 pagesEnglish languagesale 10% offe-Library read for×1 day
- 14-May-2024
- 13.040.40
- 2008/50/EC
- CEN/TC 264
1.1 Scope of EN 12309 series
Appliances covered by this document include one or a combination of the following:
- gas-fired sorption chiller;
- gas-fired sorption chiller/heater;
- gas-fired sorption heat pump;
- hybrids based on gas sorption appliances.
This document applies to appliances designed to be used for space heating or cooling or refrigeration with or without heat recovery.
This document applies to appliances having flue gas systems of Type B and Type C (according to EN 1749:2020) and to appliances designed for outdoor installations, including Type A.
EN 12309 does not apply to air conditioners, it only applies to appliances having:
- integral burners under the control of fully automatic burner control systems;
- closed system refrigerant circuits in which the refrigerant does not come into direct contact with the water or air to be cooled or heated;
- mechanical means to assist transportation of the combustion air and/or the flue gas.
The above appliances can have one or more primary or secondary functions (i.e. heat recovery - see definitions in EN 12309-1:2023).
In the case of packaged units (consisting of several parts), this document applies only to those designed and supplied as a complete package.
The appliances having their condenser cooled by air and by the evaporation of external additional water are not covered by EN 12309.
Installations used for heating and/or cooling of industrial processes are not within the scope of EN 12309. All the symbols given in this text are to be used regardless of the language used.
1.2 Scope of this Part 3 of EN 12309
This part of EN 12309 specifies the requirements, test methods and conditions for gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW.
This part of EN 12309 deals particularly with test protocols and tools to calculate the capacity, the gas utilization efficiency and the electrical power input of the appliance. This data can be used in particular to calculate the seasonal efficiency of the appliance.
- Draft71 pagesEnglish languagesale 10% offe-Library read for×1 day
This document is a specification for vertical, cylindrical tank systems, built on site, above ground and of which either the primary liquid container or the liquid tight barrier is made of steel. The secondary liquid container, if applicable, can be of steel or of concrete or a combination of both. A primary liquid container made of pre-stressed concrete is excluded from the scope of this document.
This document provides general requirements and specifies principles and application rules for the structural design of the tank system during construction, testing, commissioning, operation (accidental included), and decommissioning. This document applies to all tank system components attached to and located within the liquid, vapour, purge gas, membrane or membrane tank outer containers of the tank system. It does not address the requirements for ancillary equipment such as pumps, pumpwells, valves, instrumentation, external staircases and walkways, roof mounted platforms, external pipe supports, etc. The requirements for those components are covered by the relevant European Standards, structurally designed in accordance with Eurocodes where appropriate, and meeting applicable safety regulations.
This document also does not address tank system operating procedures unless specified for determination of the relevant resistance and protection criteria for the tank systems. It specifies minimum performance requirements for the tank system, tank system foundation and protection systems. From a process piping standpoint, the scope of this document is limited to the following boundaries:
a) the face of the first flange outside of the tank in bolted flanged connection;
b) the first threaded joint outside of the tank in threaded connection;
c) the first circumferential pipe welded joint outside of the tank in welding-end pipe connection, which does not have a flange.
This document is applicable to storage tank systems designed to store products, having an atmospheric boiling point below ambient temperature, in a dual phase, i.e. liquid and vapour. The equilibrium between liquid and vapour phases being maintained by cooling down the product to a temperature equal to, or just below, its atmospheric boiling point in combination with a slight overpressure in the storage tank system.
The maximum design pressure of the tank systems covered by this document is limited to 500 mbar. For higher pressures, reference can be made to EN 13445, Parts 1 to 5.
The operating range of the gases to be stored is between 0 °C and −196°C.
The tank systems covered by this document are used to store large volumes of hydrocarbon products, ammonia and other non-hydrocarbon gases with low temperature boiling points, generally called “Refrigerated Liquefied Gases” (RLGs). Typical products stored in the tank systems are: methane, ethane, propane, butane, ethylene, propylene, butadiene (this range includes the Liquefied Natural Gas (LNG’s) and Liquefied Petroleum Gas (LPG’s)), ammonia, nitrogen, oxygen and argon.
NOTE 1 Properties of the gases are given in Annex A.
The requirements of this document cannot cover all details of design and construction because of the variety of sizes and configurations that may be employed. Where complete requirements for a specific design are not provided, the intention is for the designer, subject to approval of the purchaser's authorized representative and of the regulatory body, to provide design and details that are as safe as those laid out in this document.
EN 14620 consists of multiple parts. This document specifies general requirements for the tank system concept, selection and general design considerations.
In case of a conflict between general requirements of this document and the requirements in other parts of EN 14620 related to a specific liquefied gas, the product-specific requirements set forth in the other parts prevail.
- Draft60 pagesEnglish languagesale 10% offe-Library read for×1 day
- 14-May-2024
- 23.020.10
- CEN/TC 265
This document specifies the detection of Clostridium (C.) perfringens.
This document is applicable to:
— products intended for human consumption;
— products intended for animal feeding;
— environmental samples in the area of food and feed production and handling;
— samples from the primary production stage.
This horizontal method was originally developed for the examination of all samples belonging to the food chain. Based on the information available at the time of publication of this document, this method is considered to be fully suited to the examination of all samples belonging to the food chain. However, because of the large variety of products in the food chain, it is possible that this horizontal method is not appropriate in every detail for all products. Nevertheless, it is expected that the required modifications are minimized so that they do not result in a significant deviation from this horizontal method.
NOTE Interlaboratory studies with a small number of participating laboratories (<10) were conducted for the following food categories:
— ready-to-eat, ready-to-reheat meat products;
— eggs and egg products (derivates);
— ready-to-eat, ready-to-reheat fishery products;
— processed fruits and vegetables;
— infant formula and infant cereals (with probiotics);
— multi-component foods or meal components.
It has also been validated with a small number of participating laboratories for the following other category:
— environmental samples (food or feed production).
Since the method is not commonly used for samples in the primary production stage, this category was not included in the interlaboratory study. Therefore, no performance characteristics were obtained for this category. The method has not been validated for the category ‘pet food and animal feed’, as the test samples used for the interlaboratory study were already naturally contaminated with C. perfringens. Given the limited number of participating laboratories in the interlaboratory studies, the calculated performance characteristics can be used as indicative values of the method performance. For detailed information on the validation, see Clause 11 and Annexes C to F.
- Draft43 pagesEnglish languagesale 10% offe-Library read for×1 day
- 14-May-2024
- 07.100.30
- 2017/625
- 882/2004
- CEN/TC 463
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.