2019-10-24 PeC: to revisit after SLR is published

  • Amendment
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62612:2013 specifies the performance requirements, together with the test methods and conditions, required to show compliance of LED lamps with integral means for stable operation, intended for domestic and similar general lighting purposes, having: - a rated power up to 60 W; - a rated voltage of > 50 V a.c. up to 250 V a.c.; - a lamp cap as listed in IEC 62560. This first edition of IEC 62612 cancels and replaces IEC/PAS 62612. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to IEC/PAS 62612. a) The standard explicitly states that real life time tests are not part of the test regime. Instead, a period of up to 6 000 h is chosen in order to assess manufacturers' claims of maintenance. b) Technical features have been adapted to IEC/PAS 62717 (performance of LED modules) as far as possible. Examples are the family approach and the temperature measuring point. c) Marking requirements are shifted from the product to the packaging. d) The number of lamps to be tested is made test specific, not general. e) First requirements are given for setting the colour for colour adjustable lamps and the luminous flux level of dimmable lamps. f) The structure of tests is clearly divided between requirement and compliance. g) Statistical compliance is separated into individual and average. h) Light output requirements are extended to luminous intensity distribution, peak intensity, beam angle and efficacy. i) The use of the terms 'correlated colour temperature' and 'chromaticity coordinates' is corrected. j) The number of tolerance categories is reduced from 8 to 4, and split between initial and maintained values. k) Colour rendering is differently assessed at initial and maintained state. l) Three lumen maintenance categories are given instead of five. m) The endurance tests are completely re-established. n) The verification (formerly: assessment) clause is completed. o) Information for luminaire design is added. p) Stabilisation is more precise (Annex A on the method of measuring lamp characteristics) and extension is made for the additional photometric and colorimetric parameters. q) Annex B on measuring luminous flux is contained in Annex A. New Annex B provides the photometric code. r) Further annexes are added: Annex C and D for displacement factor, Annex E for life time metrics/reliability and Annex F for examples of LED dies and LED packages.

  • Amendment
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2017-06-08: Final decision is to publish A1 and A11 separately the same day. A1 is identical to IEC A1.
2017-05-31: D156/039: to be published
2017-05-04: Publication on the hold pending TC 34A reply about A11 (pr=58955)
2015-11-18 - CLC/TC 34A request that A1 is published together with the European Amendment A11 (WI 58955).

  • Amendment
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62717:2014 specifies the performance requirements for LED modules, together with the test methods and conditions, required to show compliance with this standard. This first edition cancels and replaces IEC PAS 62717 published in 2011. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to IEC PAS 62717: - all terms and definitions are aligned with IEC 62504 and relevant documents of CIE. For example, general terms like "rated value" are shifted to IEC 62504. - a statement on the applicability on a population is included. - the normative references are completed and cleaned from standards that are not in use. - with regard to EMC, references to harmonic currents are given. - the change, which has an effect on most parts of the standard, is the split of failure mechanisms into abrupt failures and luminous flux depreciation. Consequently, new terms and definitions, new requirements for lumen maintenance and a complete new structure and contents of Annex C are introduced. - transition from tpmax to tprated is made, with the background that there is not one tpmax, but a choice of tp(rated) values, in combination with lifetime. - places where to mark (product, packaging, data sheets) are changed, and as a consequence of the split of failure mechanisms, new parameters are listed. Further, changes in the endurance test (ramping speed of temperature) are reflected in marking. - the concept of displacement factor instead of power factor is introduced. This led to new definitions, requirements and Annexes E and F. - the requirements on luminous efficacy are changed. - the requirements, associated with the family concept are reviewed. - statistics, based on confidence intervals are removed. This concerns requirements and limits for LED module power and luminous flux and deletion of Annex E. - new requirements for lumen maintenance are introduced. - as part of the endurance test, the maximum light decrease after accelerated operation life test is now fixed. - with regard to the discussion on type test and sample size, the number of pieces in a test sample is drastically reduced, see Table 7. - Annex A on measuring methods is completely restructured and reviewed, for example for ambient temperature and for shortening of stabilisation time when conducting subsequent light output measurements. - for electrical characteristics, the ageing time may be chosen as 500 h. - for photometric data file formats, reference is given to IEC 62722-1. - mistakes in the photometric code (Annex D) are corrected. - Annex G on optimised test duration is removed; instead, an INF sheet shall be published. - from the luminaire standard, a new Annex H on "Test equipment for temperature measurement" is taken over. - finally, the Bibliography is updated.

  • Standard
    64 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    64 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for measurement of electrical, photometric, and colorimetric quantities of LED lamps, modules, light engines and luminaires, for operation with AC or DC supply voltages, possibly with associated control gear. Photometric and colorimetric quantities covered in this standard include total luminous flux, luminous efficacy, partial luminous flux, luminous intensity distribution, centre-beam intensities, luminance and luminance distribution, chromaticity coordinates, correlated color temperature (CCT), Color Rendering Index (CRI), and spatial uniformity of chromaticity.
This standard does not cover LED packages and products based on OLEDs (organic LEDs).
NOTE   Where the term "LED product, LED device or DUT (device under test)" is used, the term covers LED lamps, modules, light engines or luminaires.

  • Standard
    71 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for measurement of electrical, photometric, and colorimetric quantities of LED lamps, modules, light engines and luminaires, for operation with AC or DC supply voltages, possibly with associated control gear. Photometric and colorimetric quantities covered in this standard include total luminous flux, luminous efficacy, partial luminous flux, luminous intensity distribution, centre-beam intensities, luminance and luminance distribution, chromaticity coordinates, correlated color temperature (CCT), Color Rendering Index (CRI), and spatial uniformity of chromaticity.
This standard does not cover LED packages and products based on OLEDs (organic LEDs).
NOTE   Where the term "LED product, LED device or DUT (device under test)" is used, the term covers LED lamps, modules, light engines or luminaires.

  • Standard
    71 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2019-10-24 PeC: to revisit after SLR is published

  • Amendment
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62722-2-1:2014 specifies the performance requirements for LED luminaires, together with the test methods and conditions, required to show compliance with this standard. It applies to LED luminaires for general lighting purposes. This first edition of IEC 62722-2-1 cancels and replaces IEC PAS 62722-2-1. published in 2011. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the Publicly Available Specification. a) The testing time is aligned with IEC 62717 and the option of 2 000 h is removed. Products containing modules not in compliance with IEC 62717 are now tested to 6 000 h. b) Testing sample sizes have been modified to give valid statistical data. c) The temperature reduction of 10 °C for street lanterns and floodlights has been removed. d) Life definitions have been updated and aligned with IEC 62717.

  • Standard
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This International Standard specifies the performance requirements for single-capped and double-capped tungsten halogen lamps, having rated voltages of up to 250 V, used for the following applications: · Projection (including cinematograph and still projection) · · Photographic (including studio) · · Floodlighting · · Special purpose · · General purpose · · Stage lighting This third edition cancels and replaces the second edition published in 1982 and amendments 1(1984), 2(1985), 3(1987), 4(1989), 5(1992), 6(1993), 7(1994), 8(1995), 9(1996), 10(1996), 11(1997), 12(1999) and 13(2000

  • Amendment
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62612:2013 specifies the performance requirements, together with the test methods and conditions, required to show compliance of LED lamps with integral means for stable operation, intended for domestic and similar general lighting purposes, having:  - a rated power up to 60 W;  - a rated voltage of > 50 V a.c. up to 250 V a.c.;  - a lamp cap as listed in IEC 62560. This first edition of IEC 62612 cancels and replaces IEC/PAS 62612. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to IEC/PAS 62612.  a) The standard explicitly states that real life time tests are not part of the test regime. Instead, a period of up to 6 000 h is chosen in order to assess manufacturers' claims of maintenance.  b) Technical features have been adapted to IEC/PAS 62717 (performance of LED modules) as far as possible. Examples are the family approach and the temperature measuring point.  c) Marking requirements are shifted from the product to the packaging.  d) The number of lamps to be tested is made test specific, not general.  e) First requirements are given for setting the colour for colour adjustable lamps and the luminous flux level of dimmable lamps.  f) The structure of tests is clearly divided between requirement and compliance.  g) Statistical compliance is separated into individual and average.  h) Light output requirements are extended to luminous intensity distribution, peak intensity, beam angle and efficacy.  i) The use of the terms 'correlated colour temperature' and 'chromaticity coordinates' is corrected.  j) The number of tolerance categories is reduced from 8 to 4, and split between initial and maintained values.  k) Colour rendering is differently assessed at initial and maintained state.  l) Three lumen maintenance categories are given instead of five.  m) The endurance tests are completely re-established.  n) The verification (formerly: assessment) clause is completed.  o) Information for luminaire design is added.  p) Stabilisation is more precise (Annex A on the method of measuring lamp characteristics) and extension is made for the additional photometric and colorimetric parameters.  q) Annex B on measuring luminous flux is contained in Annex A. New Annex B provides the photometric code.  r) Further annexes are added: Annex C and D for displacement factor, Annex E for life time metrics/reliability and Annex F for examples of LED dies and LED packages.

  • Amendment
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62612:2013 specifies the performance requirements, together with the test methods and conditions, required to show compliance of LED lamps with integral means for stable operation, intended for domestic and similar general lighting purposes, having: - a rated power up to 60 W; - a rated voltage of > 50 V a.c. up to 250 V a.c.; - a lamp cap as listed in IEC 62560. This first edition of IEC 62612 cancels and replaces IEC/PAS 62612. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to IEC/PAS 62612. a) The standard explicitly states that real life time tests are not part of the test regime. Instead, a period of up to 6 000 h is chosen in order to assess manufacturers' claims of maintenance. b) Technical features have been adapted to IEC/PAS 62717 (performance of LED modules) as far as possible. Examples are the family approach and the temperature measuring point. c) Marking requirements are shifted from the product to the packaging. d) The number of lamps to be tested is made test specific, not general. e) First requirements are given for setting the colour for colour adjustable lamps and the luminous flux level of dimmable lamps. f) The structure of tests is clearly divided between requirement and compliance. g) Statistical compliance is separated into individual and average. h) Light output requirements are extended to luminous intensity distribution, peak intensity, beam angle and efficacy. i) The use of the terms 'correlated colour temperature' and 'chromaticity coordinates' is corrected. j) The number of tolerance categories is reduced from 8 to 4, and split between initial and maintained values. k) Colour rendering is differently assessed at initial and maintained state. l) Three lumen maintenance categories are given instead of five. m) The endurance tests are completely re-established. n) The verification (formerly: assessment) clause is completed. o) Information for luminaire design is added. p) Stabilisation is more precise (Annex A on the method of measuring lamp characteristics) and extension is made for the additional photometric and colorimetric parameters. q) Annex B on measuring luminous flux is contained in Annex A. New Annex B provides the photometric code. r) Further annexes are added: Annex C and D for displacement factor, Annex E for life time metrics/reliability and Annex F for examples of LED dies and LED packages.

  • Standard
    45 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This International Standard specifies the performance requirements for single-capped and double-capped tungsten halogen lamps, having rated voltages of up to 250 V, used for the following applications: · Projection (including cinematograph and still projection) · · Photographic (including studio) · · Floodlighting · · Special purpose · · General purpose · · Stage lighting This third edition cancels and replaces the second edition published in 1982 and amendments 1(1984), 2(1985), 3(1987), 4(1989), 5(1992), 6(1993), 7(1994), 8(1995), 9(1996), 10(1996), 11(1997), 12(1999) and 13(2000

  • Amendment
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This International Standard specifies the performance requirements, together with the test methods and conditions, required to show compliance of LED lamps with integral means for stable operation, intended for domestic and similar general lighting purposes, having:
• a rated power up to 60 W;
• a rated voltage of > 50 V a.c. up to 250 V a.c.;
• a lamp cap as listed in IEC 62560.
These performance requirements are additional to the safety requirements in IEC 62560. The only feature provided by this standard, when applied for replacement purposes, is information on maximum lamp outlines. The requirements of this standard relate to type testing. This standard covers LED lamps that intentionally produce white light, based on inorganic LEDs.
Recommendations for whole product testing or batch testing are under consideration. The life time of LED lamps is in most cases much longer than the practical test times. Consequently, verification of manufacturer’s life time claims cannot be made in a sufficiently confident way, because projecting test data further in time is not standardised. For that reason the acceptance or rejection of a manufacturer's life time claim, past an operational time as stated in 7.1, is out of the scope of this standard. Instead of life time validation, this standard has opted for lumen maintenance codes at a defined finite test time. Therefore, the code number does not imply a prediction of achievable life time. The categories, represented by the code, are lumen-depreciation character categories showing behaviour in agreement with manufacturer’s information, provided before the test is started. In order to validate a life time claim, several methods of test data extrapolation exist. A general method of projecting measurement data beyond limited test time is under consideration. The pass/fail criterion of the life time test as defined in this standard is different from the life time metrics claimed by manufacturers. For explanation of recommended life time metrics, see Annex E. NOTE When lamps are operated in a luminaire the claimed performance data can deviate from the values established via this standard due to e.g. luminaire components that impact the performance of the lamp.

  • Standard
    45 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Amandma A3:2011 je dodatek k standardu SIST EN 60357:2004.
This International Standard specifies the performance requirements for single-capped and double-capped tungsten halogen lamps, having rated voltages of up to 250 V, used for the following applications:
- Projection (including cinematograph and still projection)
- Photographic (including studio)
- Floodlighting
- Special purpose
- General purpose
- Stage lighting
For some of the requirements given in this standard reference is made to "the relevant data sheet". For some lamps these data sheets are contained in this standard. For other lamps, falling under the scope of this standard, the relevant data are supplied by the lamp manufacturer or responsible vendor. The requirements of this standard relate only to type testing.
NOTE The requirements and tolerances permitted by this standard correspond to testing of a type test sample, submitted by the manufacturer for that purpose. In principle this type test sample should consist of units having characteristics typical of the manufacturer's production and being as close to the production centre point values as possible.
It may be expected with the tolerances given in the standard that products manufactured in accordance with the type test sample will comply with the standard for the majority of production. Due to the production spread however, it is inevitable that there will sometimes be products outside the specified tolerances. For guidance on sampling plans and procedures for inspection by attributes, see IEC 60410.

  • Amendment
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60432 specifies the safety requirements for single-capped and double-capped tungsten halogen lamps, having rated voltages of up to 250 V, used for the following applications:
• projection (including cinematograph and still projection),
• photographic (including studio),
• floodlighting,
• special purpose,
• general purpose,
• stage lighting,
This International Standard does not apply to general purpose single-capped tungsten halogen lamps, covered by IEC 60432-2, that are used as replacement for conventional tungsten filament lamps. This part of IEC 60432 covers photobiological safety according to IEC 62471 and IEC/TR 62471-2. Lamps covered by this part of IEC 60432 do not reach risk levels that require risk group marking if they are
a) floodlight lamps,
b) general purpose capsule lamps, or
c) general purpose reflector lamps.

  • Standard
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This International Standard specifies the safety and interchangeability requirements, together with the test methods and conditions required to show compliance of LED-lamps with integrated means for stable operation (self-ballasted LED-lamps), intended for domestic and similar general lighting purposes, having: - a rated wattage up to 60 W; - a rated voltage of > 50 V up to 250 V; - caps according to Table 1. The requirements of this standard relate only to type testing. Recommendations for whole product testing or batch testing are identical to those given in Annex C of IEC 62031.

  • Standard
    30 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60662:2011 specifies performance requirements for high-pressure sodium vapour lamps for general lighting purposes which comply with the safety requirements of IEC 62035. This second edition cancels and replaces the first edition published in 1980 and its amendments. It constitues a technical revision. Main items that required development of the 2nd edition of IEC 60662 are:  - restriction to performance requirements. Safety requirements are given in IEC 62035: Discharge lamps (excluding fluorescent lamps) - Safety specifications;  - introduction of a test device for ignition;  - split of the lamp data sheets which make use of the test device and those which do not;  - provisions for measurement during starting, measurement of electrical and photometrical characteristics and tests for lumen maintenance and life;  - general review e.g. of maximum lamp outlines and alignment of data;  - new order of data sheets by wattage.

  • Standard
    186 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This International Standard specifies sample preparation methods for determining mercury levels in new tubular fluorescent lamps (including single capped, double capped, self-ballasted and CCFL for backlighting) containing 0,1 mg mercury or more. The intended resolution of the methods described in this standard is of the order of 5 %. Mercury level measurement of spent lamps is excluded, as during lamp operation, mercury gradually diffuses into the glass wall and reacts with the glass materials. The test method of this standard does not recover mercury that is diffused into or reacted with or otherwise incorporated irreversibly with the glass wall of discharge tubes. This standard does not contain information on measurement. Measurement is specified in IEC 62321.

  • Standard
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This Technical Report describes the method of measuring and specifying the centre beam intensity and the associated beam angle(s) of reflector lamps. It applies to incandescent, tungsten halogen and gas-discharge and LED based reflector lamps for general lighting purposes. It does not apply to lamps for special purposes such as projection lamps. These recommendations relate to design testing of lamps only.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

D127/C041: 2MV on CM requested in DE comments

  • Amendment
    50 pages
    English and French language
    sale 10% off
    e-Library read for
    1 day

This International Standard gives guidance for evaluating the photobiological safety of lamps and lamp systems including luminaires. Specifically it specifies the exposure limits, reference measurement technique and classification scheme for the evaluation and control of photobiological hazards from all electrically powered incoherent broadband sources of optical radiation, including LEDs but excluding lasers, in the wavelength range from 200 nm through 3000 nm.

  • Standard
    49 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This International Standard specifies the performance requirements for single-capped and double-capped tungsten halogen lamps, having rated voltages of up to 250 V, used for the following applications: · Projection (including cinematograph and still projection) · · Photographic (including studio) · · Floodlighting · · Special purpose · · General purpose · · Stage lighting This third edition cancels and replaces the second edition published in 1982 and amendments 1(1984), 2(1985), 3(1987), 4(1989), 5(1992), 6(1993), 7(1994), 8(1995), 9(1996), 10(1996), 11(1997), 12(1999) and 13(2000

  • Standard
    212 pages
    English and French language
    sale 10% off
    e-Library read for
    1 day

This International Standard specifies the performance requirements for single-capped and double-capped tungsten halogen lamps, having rated voltages of up to 250 V, used for the following applications: · Projection (including cinematograph and still projection) · · Photographic (including studio) · · Floodlighting · · Special purpose · · General purpose · · Stage lighting This third edition cancels and replaces the second edition published in 1982 and amendments 1(1984), 2(1985), 3(1987), 4(1989), 5(1992), 6(1993), 7(1994), 8(1995), 9(1996), 10(1996), 11(1997), 12(1999) and 13(2000

  • Standard
    212 pages
    English and French language
    sale 10% off
    e-Library read for
    1 day

International Standard IEC 60432-1 specifies the safety and interchangeability requirements of
tungsten filament incandescent lamps for general lighting service having:
– rated wattage up to and including 200 W;
– rated voltage of 50 V to 250 V inclusive;
– bulbs of the A, B, C, G, M, P, PS, PAR or R shapes* , or other bulb shapes where the lamps
are intended to serve the same purpose as lamps with the foregoing bulb shapes;
– bulbs with all kinds of finishes;
– caps B15d, B22d, E12, E14, E17, E26** , E26d, E26/5039, E27 or E27/5139.
As far as is reasonably practicable, this standard is also applicable to lamps with bulbs and caps other than those mentioned above, but which serve the same purpose. This standard specifies the method a manufacturer should use to show that his product conforms to this standard on the basis of whole production appraisal in association with his test records on finished products. This method can also be applied for certification purposes. Details of a batch test procedure which can be used to make limited assessment of batches are also given. This standard is concerned with safety criteria only and does not take into account the performance of tungsten filament lamps with respect to luminous flux, life or power consumption characteristics. Readers should refer to IEC 60064 for such characteristics with respect to types normally used for general lighting service.

  • Standard
    46 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60432 specifies the safety and the related interchangeability requirements of tungsten halogen lamps for general lighting service. It covers those tungsten halogen lamps that are used as direct replacements for conventional tungsten filament lamps as well as new tungsten halogen lamps which have no correspondence in IEC 60432-1, but for which the safety and interchangeability requirements are treated by this standard in conjunction with IEC 60432-1. These tungsten halogen lamps have the following characteristics:
– rated wattage up to and including 250 W;
– rated voltage of 50 V to 250 V inclusive;
– caps B15d, B22d, E12, E14, E17, E26, E26d, E26/5039, E27 or E27/5139.
This standard also covers single-ended lamps, within the above ratings, which are not direct replacements for conventional tungsten filament lamps, but serve the same purpose.
NOTE 1 There is no implication that a tungsten halogen lamp used as a substitute for an incandescent tungsten filament lamp would use the same bulb shape as the original incandescent lamp. NOTE 2 There are two variations of E26 caps which are not fully compatible. E26/24 caps are used in North merica and E26/25 caps are used in Japan.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

It contains the recommendation of the IEC in regard to Lamp Caps and Holders in general use today, together with relevant gauges, with the object of securing International interchangeability. The gauges illustrated, although generally accepted in principle, are not necessarily the only form in which they can be made.

  • Standard
    330 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Performance requirements, test methods and conditions required to show compliance of tubular fluorescent and other gas discharge lamps with integral means for controlling starting and stable operation (self-ballasted lamps) intended for domestic and similar general lighting purposes.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Applies to lamps complying with the safety requirements in IEC 432-1 and having rated wattage of 25 W to 200 W, inclusive; rated voltage 100 V to 250 V; bulbs of the A or PS shapes; bulbs with clear, frosted or equivalently coated finishes, or white finishes; caps B22d, E26 or E27. States the performance requirements for lamps, including test methods and means of confirming compliance within the requirements. Whole production apraisal methods regarding a lamp manufacturer's test record on finished products are defined which can be applied for certification purposes.

  • Standard
    88 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60969:2016 is available as IEC 60969:2016 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 60969:2016 specifies performance requirements together with test methods and conditions required to show compliance of self-ballasted compact fluorescent lamps intended for general lighting services. This second edition cancels and replaces the first edition published in 1988, Amendment 1:1991 and Amendment 2:2000. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) title change; b) scope is now limited to compact fluorescent lamps, but expanded to cover all lamps of voltages greater than 50 V and all power ratings; c) introduction of requirements for lamp equivalency claims, switching withstand, starting time; d) low temperature, run up time, treatment of claims for different operating conditions; e) enhanced assessment and compliance criteria especially for lifetime; f) introduction in-rush test conditions and displacement factor. The contents of the corrigendum of January 2017 have been included in this copy.

  • Draft
    45 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for measurement of electrical, photometric, and colorimetric quantities of LED lamps, modules, light engines and luminaires, for operation with AC or DC supply voltages, possibly with associated control gear. Photometric and colorimetric quantities covered in this standard include total luminous flux, luminous efficacy, partial luminous flux, luminous intensity distribution, centre-beam intensities, luminance and luminance distribution, chromaticity coordinates, correlated color temperature (CCT), Color Rendering Index (CRI), and spatial uniformity of chromaticity.
This standard does not cover LED packages and products based on OLEDs (organic LEDs).
NOTE   Where the term "LED product, LED device or DUT (device under test)" is used, the term covers LED lamps, modules, light engines or luminaires.

  • Draft
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60969:2016 is available as IEC 60969:2016 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60969:2016 specifies performance requirements together with test methods and conditions required to show compliance of self-ballasted compact fluorescent lamps intended for general lighting services. This second edition cancels and replaces the first edition published in 1988, Amendment 1:1991 and Amendment 2:2000. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) title change;
b) scope is now limited to compact fluorescent lamps, but expanded to cover all lamps of voltages greater than 50 V and all power ratings;
c) introduction of requirements for lamp equivalency claims, switching withstand, starting time;
d) low temperature, run up time, treatment of claims for different operating conditions;
e) enhanced assessment and compliance criteria especially for lifetime;
f) introduction in-rush test conditions and displacement factor.
The contents of the corrigendum of January 2017 have been included in this copy.

  • Draft
    45 pages
    English language
    sale 10% off
    e-Library read for
    1 day

CMs merged with PR=24308 on 2016-06-10

  • Draft
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for measurement of electrical, photometric, and colorimetric quantities of LED lamps, modules, light engines and luminaires, for operation with AC or DC supply voltages, possibly with associated control gear. Photometric and colorimetric quantities covered in this standard include total luminous flux, luminous efficacy, partial luminous flux, luminous intensity distribution, centre-beam intensities, luminance and luminance distribution, chromaticity coordinates, correlated color temperature (CCT), Color Rendering Index (CRI), and spatial uniformity of chromaticity.
This standard does not cover LED packages and products based on OLEDs (organic LEDs).
NOTE   Where the term "LED product, LED device or DUT (device under test)" is used, the term covers LED lamps, modules, light engines or luminaires.

  • Draft
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 62442 defines a measurement and calculation method of the total input power for controlgear ? lamp circuits when operating with their associated fluorescent lamp(s). The calculation method for the efficiency of the lamp controlgear is also defined. This International Standard applies to electrical controlgear lamp circuits consisting only of the controlgear and the lamp(s). It is intended for use on a.c. supplies up to 1 000 V at 50 Hz or 60 Hz.

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

EN IEC 62442-2 defines a measurement method of the power losses of electromagnetic controlgear, the total input power and the standby power of electronic controlgear for high intensity discharged lamps (excluding fluorescent lamps). Also a calculation method of the efficiency for controlgear for high intensity discharged lamp(s) is defined. This International Standard applies to electrical controlgear - lamp circuits comprised solely of the controlgear and of the lamp(s).

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

EN IEC 62442-3 defines a measurement method for the power losses of magnetic transformers and the power losses with the standby power of electronic convertor for halogen lamps and LED modules. Also a calculation method of the efficiency for the mentioned controlgear for halogen lamps and LED modules is defined. This part of IEC 62442 applies to electrical controlgear - lamp circuits comprised solely of the controlgear and of the lamp(s). For multipurpose power supplies only the lighting part will be considered. It specifies the measurement method for the total input power, the standby power and the calculation method of the controlgear efficiency for all controlgear sold for domestic and normal commercial purposes operating with halogen lamps and LED modules.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for measurement of electrical, photometric, and colorimetric quantities of LED lamps, modules, light engines and luminaires, for operation with AC or DC supply voltages, possibly with associated control gear. Photometric and colorimetric quantities covered in this standard include total luminous flux, luminous efficacy, partial luminous flux, luminous intensity distribution, centre-beam intensities, luminance and luminance distribution, chromaticity coordinates, correlated color temperature (CCT), Color Rendering Index (CRI), and spatial uniformity of chromaticity.
This standard does not cover LED packages and products based on OLEDs (organic LEDs).
NOTE   Where the term "LED product, LED device or DUT (device under test)" is used, the term covers LED lamps, modules, light engines or luminaires.

  • Standard
    65 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This International Standard specifies the performance requirements for metal halide lamps for general lighting purposes. For some of the requirements given in this standard, reference is made to “the relevant lamp data sheet”. For some lamps, these data sheets are contained in this standard. For other lamps, falling under the scope of this standard, the relevant data are supplied by the lamp manufacturer or responsible vendor. The requirements of this standard relate only to type testing.

  • Standard
    161 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This International Standard specifies the safety and interchangeability requirements, together with the test methods and conditions, required to show compliance of tubular fluorescent and other gas-discharge lamps with integrated means for controlling starting and stable operation (self-ballasted lamps), intended for domestic and similar general lighting purposes, having:
– a rated wattage up to 60 W;
– a rated voltage of 100 V to 250 V;
– Edison screw or bayonet caps.
The requirements of this standard relate only to type testing.
Recommendations for whole product testing or batch testing are under consideration. This part of the standard covers photobiological safety according to IEC 62471 and IEC/TR 62471-2. Blue light and infrared hazards are below the level which requires marking.

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 61000 deals with the limitation of harmonic currents injected into the public supply system. It specifies limits of harmonic components of the input current which may be produced by equipment tested under specified conditions. Harmonic components are measured according to Annexes A and B. This part of IEC 61000 is applicable to electrical and electronic equipment having an input current up to and including 16 A per phase, and intended to be connected to public low-voltage distribution systems. Arc welding equipment which is not professional equipment, with input current up to and including 16 A per phase, is included in this standard. Arc welding equipment intended for professional use, as specified in IEC 60974-1, is excluded from this standard and may be subject to installation restrictions as indicated in IEC 61000-3-4 or IEC 61000-3-12. The tests according to this standard are type tests. Test conditions for particular equipment are given in Annex C. For systems with nominal voltages less than 220 V (line-to-neutral), the limits have not yet been considered.

  • Standard
    34 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard establishes general principles for the measurement of basic photometric data for lighting application purposes. It establishes the measurement criteria needed for the standardisation of basic photometric data and details of the CEN file format for electronic data transfer. In addition to it being a valuable standard in its own right, this standard has been written in two parts to provide the basis of photometric measurement in part 1 and verification and presentation techniques for specific lighting applications in part 2.

  • Standard
    62 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Specifies dimensions and characteristics of tungsten halogen lamps, designed specifically for the following applications: projection, photographic (including studio), flood lighting, specialized airfield purpose and general purpose. This is a loose-leaf publication; supplements, containing new and revised sheets, are issued from time to time. Consolidated edition incorporating the amendments 1, 2, 3, 4, 5, 6, 7 and 8.

  • Standard
    82 pages
    English language
    sale 10% off
    e-Library read for