This document establishes the requirements and test methods for rubber and plastics suction hoses for fire-fighting purposes. These hoses can also be used manually to supply unpressurized water to the pump or for water discharge. NOTE      All pressures are expressed in megapascals and in bar (1 MPa = 10 bar). Additional requirements are specified for hose assemblies, that is, hoses with couplings already fitted, where this is carried out by the hose manufacturer (see Clause 8). TypeÂ...view more

    • sale 15% off
    • Standard
      18 pages
      English language
    • sale 15% off
    • Standard
      20 pages
      French language
    • sale 15% off
    • Draft
      18 pages
      English language
    • sale 15% off
    • Draft
      20 pages
      French language

This document specifies requirements for earthquake protection of automatic sprinkler systems in accordance with EN 12845 . This document applies only to locations in earthquake zones in accordance to EN 1998-1:2004, 3.2.11) and for area subject to peak ground acceleration above 9 % of g.
This document does not cover all legislative requirements. In certain countries specific national regulations apply and take precedence over this document. Users of this document are advised to inform themselv...
view more

    • sale 10% off
    • Technical specification
      29 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Technical specification
      28 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies requirements and gives recommendations for the design, installation, inspection and maintenance of fixed land based water mist systems.
This document is intended to apply to water mist automatic nozzle systems and water mist deluge systems supplied by stand alone or pumped systems.
Aspects of water mist associated with explosion protection are not covered by this European Standard.
This standard does not cover all legislative requirements. In certain countries...
view more

    • sale 10% off
    • Standard
      99 pages
      English language
    • e-Library read for
      1 day

This part of EN 15004 contains specific requirements for gaseous fire-extinguishing systems, with respect to the HFC 23 extinguishant. It includes details of physical properties, specification, usage and safety aspects and is applicable to systems operating at a nominal pressure of 41 bar without nitrogen superpressurization and 70 bar superpressurized with nitrogen.

    • sale 10% off
    • Standard
      14 pages
      English language
    • e-Library read for
      1 day

This document specifies requirements for gaseous fire-extinguishing systems, with respect to the HFC 125 extinguishant. It includes details of physical properties, specification, usage and safety aspects.
This document is apploicable for systems operating at nominal pressures of 25 bar and 42 bar, superpressurized with nitrogen. This does not preclude the use of other systems.

    • sale 10% off
    • Standard
      13 pages
      English language
    • e-Library read for
      1 day

This document specifies requirements for gaseous fire-extinguishing systems, with respect to FK 5 1 12 extinguishant. It includes details of physical properties, specification, usage and safety aspects.
This document covers only systems operating at nominal pressures of 25 bar, 34,5 bar, 42 bar and 50 bar with nitrogen propellant. This does not preclude the use of other systems.

    • sale 10% off
    • Standard
      16 pages
      English language
    • e-Library read for
      1 day

This part of EN 15004 contains specific requirements for gaseous fire-extinguishing systems, with respect to the HFC 227ea extinguishant. It includes details of physical properties, specification, usage and safety aspects.
This part of EN 15004 covers systems operating at nominal pressures of 25 bar, 42 bar and 50 bar with nitrogen propellant. This does not preclude the use of other systems.

    • sale 10% off
    • Standard
      14 pages
      English language
    • e-Library read for
      1 day

This document specifies minimum performance requirements for protective clothing designed to be worn during firefighting activities. The requirements are detailed in this document covering heat and flame, mechanical, chemical, comfort, visibility, etc.
This document covers the general clothing design, the minimum performance levels of the material used, the methods of test to be used to determine these performance levels, marking and information supplied by the manufacturer.
This document make...
view more

    • sale 10% off
    • Standard
      44 pages
      English language
    • e-Library read for
      1 day

1.1   This document defines requirements and tests which apply to:
-   collecting heads with a nominal pressure of 16 bar (1,6 MPa) PN16 which are used by fire and rescue services to combine two or more inlets into one or more outlets;
-   dividing breechings with a nominal pressure of 16 bar (1,6 MPa) PN 16 which are used by fire and rescue services to divide one or more inlets into two or more outlets.
NOTE 1   In this document "ColDiv" is used to refer both to collecting heads and dividing breechi...
view more

    • sale 10% off
    • Standard
      25 pages
      English language
    • e-Library read for
      1 day

This European standard specifies oxygen reduction systems that are used as fire prevention systems by creating an atmosphere in an area which is having a lower permanent oxygen concentration as in ambient conditions. The level of oxygen reduction is defined by the individual risks of these areas (see Annex A). Oxygen reduction is achieved by technical systems which are providing a flux of air containing a reduced concentration of oxygen.
This European standard specifies minimum requirements and...
view more

    • sale 10% off
    • Standard
      37 pages
      English language
    • e-Library read for
      1 day

1.1   This document specifies the additional or deviating requirements to prEN 81 20:2018 for new passenger and goods passenger lifts, which may be used for firefighting and evacuation purposes under firefighters control.
1.2   This document applies, when the following conditions are fulfilled:
-   the lift well and the lift environment are designed to restrict the ingress of fire, heat and smoke to the lift well, machinery spaces and safe areas;
-   the building design limits the flow of water into ...
view more

    • sale 10% off
    • Standard
      46 pages
      English language
    • e-Library read for
      1 day

This document specifies the minimum performance requirements and methods of test for firehoods that cover the head and neck and are used for wildland firefighting. An optional requirement has been included to provide limited protection against particulate contaminants This document covers the general design of the PPE, the minimum levels of performance for the materials employed and the methods of test used. This PPE is not intended to provide protection during fire entrapment. This document doe...view more

    • sale 15% off
    • Standard
      16 pages
      English language
    • sale 15% off
    • Draft
      16 pages
      English language

This International Standard specifies methods of test and minimum performance requirements for protective clothing to
be worn in wildland firefighting and associated activities. This clothing is not intended to provide protection during fire
entrapment. This International Standard applies to the general design of the garment, the minimum level of performance for the materials employed and the methods of test to determine these levels.
This International Standard is not applicable to clothing for...
view more

    • sale 10% off
    • Standard
      22 pages
      English language
    • e-Library read for
      1 day

This draft European Standard specifies the characteristics, performance and test methods for extinguishing aerosol dispensers, in accordance with Directive 75/324/EEC, for fire extinguishing purposes. Requirements in this draft Standard are specified for products containing less than 1 kg or 1 l of extinguishing media, which can be expelled by the action of internal pressure and are intended to extinguish test fires of type A + B, or type A + F, or type A + B + F classes of EN 2. These extinguis...view more

    • sale 10% off
    • Standard
      41 pages
      English language
    • e-Library read for
      1 day
    • sale 15% off
    • Standard
      2 pages
      English language

This European Standard applies to resettable line-type heat detectors consisting of a sensing element using an optical fibre, a pneumatic tube or an electrical sensor cable connected to a sensor control unit, either directly or through an interface module, intended for use in fire detection and fire alarm systems installed in and around buildings and other civil engineering works (see EN 54-1:2011).
This European Standard specifies the requirements and performance criteria, the corresponding te...
view more

    • sale 10% off
    • Standard
      74 pages
      English language
    • e-Library read for
      1 day

This European Standard applies to resettable line-type heat detectors consisting of a sensing element using an optical fibre, a pneumatic tube or an electrical sensor cable connected to a sensor control unit, either directly or through an interface module, intended for use in fire detection and fire alarm systems installed in and around buildings and other civil engineering works (see EN 54-1:2011).
This European Standard specifies the requirements and performance criteria, the corresponding te...
view more

    • sale 10% off
    • Standard
      74 pages
      English language
    • e-Library read for
      1 day

This document specifies fire testing requirements for water mist systems used for fire protection of machinery in enclosures with volumes not exceeding 260 m³.

    • sale 10% off
    • Standard
      16 pages
      English language
    • e-Library read for
      1 day

This document specifies requirements for the construction and performance of residential sprinklers as well as test methods for their type approval, which are operated by a change of state of an element or bursting of a glass bulb under the influence of heat, for use only in automatic sprinkler systems for domestic and residential applications as defined in EN 16925:− .
This standard does not cover representative fire and other tests for special sprinklers that are intended to provide for speci...
view more

    • sale 10% off
    • Standard
      64 pages
      English language
    • e-Library read for
      1 day

This document specifies fire testing requirements for water mist systems used for fire protection of machinery in enclosures with volumes exceeding 260 m³.

    • sale 10% off
    • Standard
      17 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies requirements and gives recommendations for the design, installation and maintenance of fixed fire sprinkler systems in buildings and industrial plants, and particular requirements for sprinkler systems that are integral to measures for the protection of life.
This European Standard covers only the types of sprinkler specified in EN 12259 1 (see Annex L).
The requirements and recommendations of this European Standard are also applicable to any addition, extensio...
view more

    • sale 10% off
    • Standard
      215 pages
      English language
    • e-Library read for
      1 day

This document specifies the minimum performance requirements and methods of test for helmets used for wildland firefighting. This document covers the general design of wildland firefighting helmets, the minimum levels of performance for the materials employed and the methods of test used. The personal protection equipment (PPE) is not intended to provide protection during fire entrapment. This document does not cover PPE for structural firefighting (see ISO 11999 series), for use against chemica...view more

    • sale 15% off
    • Standard
      22 pages
      English language

This European Standard specifies the Sweating Torso as a method to
measure the coupled heat and mass transfer through protective clothing
in fire fighters’ specific conditions.
NOTE The Sweating Torso is developed to perform highly reproducible
laboratory tests for heat and mass transfer on clothing systems under
controlled conditions which are closely correlated to real conditions. The
Sweating Torso is a cylinder with the same size as a human trunk. The
layers of the measurement cylinder are ...
view more

    • sale 10% off
    • Amendment
      8 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Amendment
      5 pages
      English language
    • e-Library read for
      1 day
    • sale 15% off
    • Standard
      1 page
      English language

This document specifies the minimum performance requirements and methods of test for personal protective equipment (PPE), gloves, that cover the hands whilst wildland firefighting. This document covers the general design of the PPE, the minimum levels of performance for the materials employed and the methods of test used. This PPE is not intended to provide protection during fire entrapment. A risk assessment (see ISO/TR 21808) can be undertaken to determine if the gloves covered by this documen...view more

    • sale 15% off
    • Standard
      17 pages
      English language

This document specifies the minimum performance requirements and methods of test for personal protective equipment (PPE) face and eye protection, for wildland firefighting. This document covers the general design of the PPE, the minimum levels of performance for the materials employed and the methods of test used. This PPE is not intended to provide protection during fire entrapment. This document does not cover PPE for structural firefighting (see ISO 11999 series), for use against chemical, bi...view more

    • sale 15% off
    • Standard
      23 pages
      English language

This document specifies the minimum performance requirements and test methods for assessing compatibility of wildland firefighters' personal protective equipment (PPE). This document does not cover PPE for structural firefighting (see ISO 11999 series), for use against chemical, biological, radiological and nuclear hazards, or for use where a reflective outer surface is required (see ISO 15538). Activities in support of wildland firefighting, such as the cutting of trees and the use of a chainsa...view more

    • sale 15% off
    • Standard
      3 pages
      English language

This European standard describes a thermophysiological model (thermal
human simulator) that uses the output data of the first part to obtain
physiological heat load criteria that predicts the (maximal) duration of
work in the protective clothing in fire fighters’ relevant conditions.
NOTE The human simulator method using the Sweating Torso (i.e.
coupling of the instrumented manikin with a thermo-physiological
feedback model) is validated for different scenarios by comparison to
human subject tri...
view more

    • sale 10% off
    • Amendment
      7 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Amendment
      4 pages
      English language
    • e-Library read for
      1 day

This document specifies the minimum performance requirements and methods of test for personal protective equipment (PPE) covering the torso, neck, arms, hands, legs, feet, head, eyes and hearing that is used for wildland firefighting. This document covers the general design of the PPE, the minimum levels of performance for the materials employed and the methods of test used. The PPE is not intended to provide protection during fire entrapment. This document does not cover PPE for structural fire...view more

    • sale 15% off
    • Standard
      13 pages
      English language

This document specifies test methods and minimum performance requirements for personal protective clothing, designed to protect the wearer's body, except for the head, hands, and feet, that is worn during wildland firefighting and associated activities. This clothing is not intended to provide protection during fire entrapment. This document covers the general design of the garment, the minimum level of performance for the materials employed and the methods of test to determine these levels. Thi...view more

    • sale 15% off
    • Standard
      2 pages
      English language

This document specifies the minimum performance requirements and methods of test for hearing protection used when wildland firefighting. This document covers the general design of the personal protective equipment (PPE), the minimum levels of performance for the materials employed and the methods of test used. The PPE is not intended to provide protection during fire entrapment. This document does not cover PPE for structural firefighting (see ISO 11999 series), for use against chemical, biologi...view more

    • sale 15% off
    • Standard
      4 pages
      English language

In addition to the requirements given in EN 15182-1, this document applies to hand-held combination branchpipes (nozzles) PN 16 with a maximum flow rate up to 1 000 l/min at a reference pressure of 6 bar (0,6 MPa). It deals with:
-   safety requirements;
-   performance requirements;
-   test methods.
This document applies to branchpipes as defined in Annex A of EN 15182-1.

    • sale 10% off
    • Standard
      13 pages
      English language
    • e-Library read for
      1 day

This document applies to hand-held branchpipes. It deals with:
-   safety requirements;
-   performance requirements;
-   test methods;
-   classification and designation;
-   instructions for use and maintenance;
-   marking.
It is advised to read this document in conjunction with parts 2, 3 or 4.
This document does not apply to branchpipes covered by EN 671, foam branchpipes covered by EN 16712-3, powder branchpipes, or branchpipes with a maximum working pressure above 40 bar.
NOTE 1   The Working ...
view more

    • sale 10% off
    • Standard
      28 pages
      English language
    • e-Library read for
      1 day

This document applies to hand-held branchpipes. It deals with:
- safety requirements;
- performance requirements;
- test methods;
- classification and designation;
- instructions for use and maintenance;
- marking.
It is advised to read this document in conjunction with parts 2, 3 or 4.
This document does not apply to branchpipes covered by EN 671 series, foam branchpipes covered by EN 16712-3, powder branchpipes, or branchpipes with a maximum working pressure above 40 bar.
NOTE 1   The W...
view more

    • sale 10% off
    • Standard
      28 pages
      English language
    • e-Library read for
      1 day

In addition to the requirements given in EN 15182-1:2019, this document applies to hand-held combination branchpipes (nozzles), with a nominal pressure of 16 bar (1,6 MPa) PN 16, with a maximum flow rate up to 1 000 l/min at a reference pressure of 6 bar (0,6 MPa). It deals with:
- safety requirements;
- performance requirements;
- test methods.
This document applies to branchpipes as defined in Annex A of EN 15182-1:2019.

    • sale 10% off
    • Standard
      13 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies fire testing requirements for water mist systems used for fire protection of industrial oil cookers. This does not include requirements for systems used for protection of other equipment such as exhaust air ducts, heaters, heat exchangers, and food processing and food preparation areas.

    • sale 10% off
    • Standard
      15 pages
      English language
    • e-Library read for
      1 day

In addition to the requirements given in EN 15182-1, this document applies to hand-held high pressure branchpipes (nozzles) PN 40 with a maximum flow rate up to 250 l/min at a reference pressure of 6 bar (0,6 MPa). It deals with:
-   safety requirements;
-   performance requirements;
-   test methods.
This document applies to branchpipes as defined in Annex A of EN 15182-1.

    • sale 10% off
    • Standard
      13 pages
      English language
    • e-Library read for
      1 day

In addition to the requirements given in EN 15182-1, this document applies to hand-held branchpipes with smooth bore jet and/or one fixed spray jet angle branchpipes PN 16, with a maximum flow rate of 1 000 l/min at a reference pressure of 6 bar (0,6 MPa). It deals with:
-   safety requirements;
-   performance requirements;
-   test methods.
This document applies to branchpipes as defined in Annex A of EN 15182-1.
WARNING 1 - These branchpipes offer no or inadequate protection for firefighters w...
view more

    • sale 10% off
    • Standard
      9 pages
      English language
    • e-Library read for
      1 day

This document specifies requirements for fire blankets which are not re-usable and that are intended for use by one person.
It specifies requirements for fire blankets usable to control small fires. It also limits the risk of electric shock in case of unintentional use on live electrical equipment.
Fire blankets that are large enough are considered suitable to be used for smothering persons whose clothes are on fire.

    • sale 10% off
    • Standard
      18 pages
      English language
    • e-Library read for
      1 day

This document specifies minimum requirements and defines the specifications governing the design, installation and maintenance of fixed oxygen reduction systems with oxygen reduced air for fire prevention in buildings and industrial production plants. It also applies to the extension and modification of existing systems. This document applies to oxygen reduction systems using nitrogen-enriched-air which are designed for continual oxygen reduction in enclosed spaces. NOTE Nitrogen is, today, the ...view more

    • sale 15% off
    • Standard
      24 pages
      English language

In addition to the requirements given in EN 15182-1:2019, this document applies to hand-held high pressure branchpipes (nozzles) with a nominal pressure of 40 bar (4,0 MPa) PN 40, with a maximum flow rate up to 250 l/min at a reference pressure of 6 bar (0,6 MPa). It deals with:
- safety requirements;
-  performance requirements;
- test methods.
This document applies to branchpipes as defined in Annex A of EN 15182-1:2019.

    • sale 10% off
    • Standard
      13 pages
      English language
    • e-Library read for
      1 day

This document specifies requirements for fire blankets which are not reusable and that are intended for use by one person.
It specifies requirements for fire blankets usable to control small fires. It also limits the risk of electric shock in case of unintentional use on live electrical equipment.
Fire blankets that are large enough are considered suitable to be used for smothering persons whose clothes are on fire.

    • sale 10% off
    • Standard
      18 pages
      English language
    • e-Library read for
      1 day

In addition to the requirements given in EN 15182-1:2019, this document applies to hand-held branchpipes with smooth bore jet and/or one fixed spray jet angle branchpipes with a nominal pressure of 16 bar (1,6 MPa) PN 16, with a maximum flow rate up to 1 000 l/min at a reference pressure of 6 bar (0,6 MPa). It deals with:
- safety requirements;
- performance requirements;
- test methods.
This document applies to branchpipes as defined in Annex A of EN 15182-1:2019.
WARNING 1 — These branchp...
view more

    • sale 10% off
    • Standard
      9 pages
      English language
    • e-Library read for
      1 day

This document contains specific requirements for gaseous fire-extinguishing systems, with respect to the HFC 23 extinguishant. It includes details of physical properties, specifications, usage and safety aspects. It is applicable to systems operating at a nominal pressure of 41 bar without nitrogen superpressurization and 70 bar superpressurized with nitrogen.

    • sale 15% off
    • Standard
      10 pages
      English language

This document contains specific requirements for gaseous fire-extinguishing systems, with respect to the HFC 227ea extinguishant. It includes details of physical properties, specifications, usage and safety aspects. This document is applicable to systems operating at nominal pressures of 25 bar, 42 bar and 50 bar with nitrogen propellant. This does not preclude the use of other systems.

    • sale 15% off
    • Standard
      11 pages
      English language

This document contains specific requirements for gaseous fire-extinguishing systems, with respect to the HFC 125 extinguishant. It includes details of physical properties, specifications, usage and safety aspects. This document is applicable to systems operating at nominal pressures of 25 bar and 42 bar, superpressurized with nitrogen. This does not preclude the use of other systems.

    • sale 15% off
    • Standard
      9 pages
      English language

This document contains specific requirements for gaseous fire-extinguishing systems, with respect to FK-5-1-12 extinguishant. It includes details of physical properties, specifications, usage and safety aspects. This document is applicable only to systems operating at nominal pressures of 25 bar, 34,5 bar, 42 bar and 50 bar with nitrogen propellant. This does not preclude the use of other systems.

    • sale 15% off
    • Standard
      11 pages
      English language

This document specifies the essential properties and performance of liquid foam concentrates used to make medium- or high-expansion foams or both for the control, the extinction and the inhibition of reignition of fires of water-immiscible liquids. Minimum performance on certain test fires is specified. These foams are suitable for top application to fires of water-immiscible liquid. Those foams that comply with ISO 7203-1 are also suitable for top application to fires of water-immiscible liquid...view more

    • sale 15% off
    • Standard
      41 pages
      English language

This document specifies the essential properties and performance of liquid foam concentrates used to make low-expansion foams for the control, extinction and inhibition of re-ignition of fires of water-miscible liquids. Minimum performance on certain test fires is specified. These foams are suitable for top application to fires of water-miscible liquids. Those foams that also comply with ISO 7203-1 are also suitable for top application to fires of water-immiscible liquids. The foam concentrates ...view more

    • sale 15% off
    • Standard
      39 pages
      English language

This document specifies the essential properties and performance of liquid foam concentrates used to make low-expansion foams for the control, the extinction and the inhibition of reignition of fires of water-immiscible liquids. Minimum performance on certain test fires is specified. These foams are suitable for top application to fires of water-immiscible liquids. The foams that conform with ISO 7203-3 are also suitable for top application to fires of water-miscible liquids. The foam concentrat...view more

    • sale 15% off
    • Standard
      42 pages
      English language