This document describes procedures to assess the applicability of the standard method EN 16909 (determination of OC and EC deposited on filters) to particle size fractions up to 10 µm in aerodynamic diameter (50 % cut off).

    • sale 10% off
    • Technical report
      21 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Technical report
      21 pages
      English language
    • e-Library read for
      1 day

This document specifies the requirements and test methods of bamboo charcoal for air-purification applications.

    • sale 15% off
    • Standard
      5 pages
      English language
    • sale 15% off
    • Draft
      5 pages
      English language
    • sale 15% off
    • Draft
      5 pages
      English language

This document specifies a laboratory test method using test chambers defined in ISO 16000-9 and further specified in EN 16516 and evaluation procedures for the determination of odours emitted from building products and materials. Sampling, transport and storage of materials under test, as well as preparation of test specimens are described in ISO 16000-11 and further specified in EN 16516.

    • sale 15% off
    • Standard
      37 pages
      French language
    • sale 15% off
    • Standard
      35 pages
      English language
    • sale 15% off
    • Draft
      37 pages
      French language
    • sale 15% off
    • Draft
      35 pages
      English language

This European Standard specifies a horizontal reference method for the determination of emissions of regulated dangerous substances from construction products into indoor air. This method is applicable to volatile organic compounds, semi-volatile organic compounds, and very volatile aldehydes. It is based on the use of a test chamber and subsequent analysis of the organic compounds by GC-MS or HPLC.
NOTE 1   Supplemental information is given on indirect test methods (see Annex B) and on measuring...
view more

    • sale 10% off
    • Standard
      61 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies a method for the sampling and analysis of NH3 in ambient air using
diffusive sampling.
It can be used for NH3 measurements at ambient levels but the concentration range and exposure time are sampler dependent and the end user shall use the working conditions for the various devices as recommended by the manufacturer.
Denuders may be used as a surrogate reference method, and for this reason their use is also described in this European Standard.

    • sale 10% off
    • Standard
      45 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      47 pages
      English language
    • e-Library read for
      1 day

This document describes a standard method for determining particle number size distributions in ambient air in the size range from 10 nm to 800 nm at total concentrations up to approximately 105 cm–3 with a time resolution of a few minutes. The standard method is based on a Mobility Particle Size Spectrometer (MPSS) used with a bipolar diffusion charger and a Condensation Particle Counter (CPC) as the detector. The document describes the performance characteristics and minimum requirements of th...view more

    • sale 10% off
    • Technical specification
      63 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Technical specification
      62 pages
      English language
    • e-Library read for
      1 day

This document describes a standard method for determining particle number size distributions in ambient air in the size range from 10 nm to 800 nm at total concentrations up to approximately 10^5 cm^-3 with a time resolution of a few minutes. The standard method is based on a Mobility Particle Size Spectrometer (MPSS) used with a bipolar diffusion charger and a Condensation Particle Counter (CPC) as the detector. The document describes the performance characteristics and minimum requirements of ...view more

    • sale 10% off
    • Technical specification
      63 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Technical specification
      62 pages
      English language
    • e-Library read for
      1 day

ISO 14966 specifies a method using scanning electron microscopy for determination of the concentration of inorganic fibrous particles in the air. The method specifies the use of gold-coated, capillary-pore, track-etched membrane filters, through which a known volume of air has been drawn. Using energy-dispersive X-ray analysis, the method can discriminate between fibres with compositions consistent with those of the asbestos varieties (e.g. serpentine and amphibole), gypsum, and other inorganic ...view more

    • sale 15% off
    • Standard
      49 pages
      English language
    • sale 10% off
    • Standard
      55 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      56 pages
      English language
    • e-Library read for
      1 day

This document specifies a method using scanning electron microscopy for determination of the concentration of inorganic fibrous particles in the air. The method specifies the use of gold-coated, capillary-pore, track-etched membrane filters, through which a known volume of air has been drawn. Using energy-dispersive X-ray analysis, the method can discriminate between fibres with compositions consistent with those of the asbestos varieties (e.g. serpentine and amphibole), gypsum, and other inorga...view more

    • sale 15% off
    • Standard
      49 pages
      English language
    • sale 10% off
    • Standard
      55 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      56 pages
      English language
    • e-Library read for
      1 day

This document specifies a reference method using transmission electron microscopy for the determination of airborne asbestos fibres and structures in in a wide range of ambient air situations, including the interior atmospheres of buildings, and for a detailed evaluation for asbestos structures in any atmosphere. The specimen preparation procedure incorporates ashing and dispersion of the collected particulate, so that all asbestos is measured, including the asbestos originally incorporated in p...view more

    • sale 15% off
    • Standard
      84 pages
      French language
    • sale 15% off
    • Standard
      80 pages
      English language
    • sale 10% off
    • Standard
      87 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      90 pages
      English language
    • e-Library read for
      1 day

This document specifies requirements for an indoor air quality management system. It is applicable to any organization that wishes to:
a) establish a system for the management of the quality of indoor air;
b) implement, maintain and continually improve the indoor air quality management system;
c) ensure conformity to the indoor air quality management system;
d) demonstrate conformity to this document.
It is applicable to the indoor environments of all kinds of facilities, installations and ...
view more

    • sale 15% off
    • Standard
      26 pages
      French language
    • sale 15% off
    • Standard
      23 pages
      English language
    • sale 10% off
    • Standard
      29 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      29 pages
      English language
    • e-Library read for
      1 day

This document specifies a reference method using transmission electron microscopy for the determination of airborne asbestos fibres and structures in in a wide range of ambient air situations, including the interior atmospheres of buildings, and for a detailed evaluation for asbestos structures in any atmosphere. The method allows determination of the type(s) of asbestos fibres present and also includes measurement of the lengths, widths and aspect ratios of the asbestos structures. The method c...view more

    • sale 15% off
    • Standard
      75 pages
      French language
    • sale 15% off
    • Standard
      72 pages
      English language
    • sale 10% off
    • Standard
      78 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      84 pages
      English language
    • e-Library read for
      1 day

This document, along with ISO 16000-38, specifies the measurement method for determining the mass concentration of primary, secondary and tertiary aliphatic and aromatic amines in indoor air using accumulated sampling and high-performance liquid chromatography (HPLC) coupled with tandem mass spectrometry (MS-MS) or high-resolution mass spectrometry (HRMS). The analytical procedure is covered by this document. The sampling procedure and the manufacturing of the samplers are covered by ISO 16000-3...view more

    • sale 15% off
    • Standard
      12 pages
      English language
    • sale 10% off
    • Standard
      17 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Standard
      17 pages
      English language
    • e-Library read for
      1 day

This document specifies a method for the determination of primary, secondary and tertiary aliphatic
and aromatic amines in indoor air using accumulated sampling and high-performance liquidchromatography
(HPLC) coupled with tandem mass spectrometry (MS-MS) or high resolution mass
spectrometry (HRMS). It specifies the sampling procedure for determining the mass concentration of
amines as mean values by sampling the amines on phosphoric acid impregnated filters. The analytical
procedure of the...
view more

    • sale 15% off
    • Standard
      9 pages
      English language
    • sale 10% off
    • Standard
      14 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Standard
      14 pages
      English language
    • e-Library read for
      1 day

This document specifies a large bag sampling method for measuring volatile organic compounds (VOCs), formaldehyde and other carbonyl compounds which are emitted from vehicle interior parts into the air inside road vehicles. This method is intended for evaluation of large new vehicle interior parts, and complete assemblies. This is a screening method to compare similar car components under similar test conditions on a routine basis. Evaluating VOC emissions of vehicle interior parts is an importa...view more

    • sale 15% off
    • Standard
      15 pages
      English language
    • sale 10% off
    • Standard
      20 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Standard
      20 pages
      English language
    • e-Library read for
      1 day

This document specifies a reference method using transmission electron microscopy for the determination of airborne asbestos fibres and structures in in a wide range of ambient air situations, including the interior atmospheres of buildings, and for a detailed evaluation for asbestos structures in any atmosphere. The method allows determination of the type(s) of asbestos fibres present and also includes measurement of the lengths, widths and aspect ratios of the asbestos structures. The method c...view more

    • sale 15% off
    • Standard
      75 pages
      French language
    • sale 15% off
    • Standard
      72 pages
      English language
    • sale 10% off
    • Standard
      78 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      84 pages
      English language
    • e-Library read for
      1 day

This document specifies a reference method using transmission electron microscopy for the determination of airborne asbestos fibres and structures in in a wide range of ambient air situations, including the interior atmospheres of buildings, and for a detailed evaluation for asbestos structures in any atmosphere. The specimen preparation procedure incorporates ashing and dispersion of the collected particulate, so that all asbestos is measured, including the asbestos originally incorporated in p...view more

    • sale 15% off
    • Standard
      84 pages
      French language
    • sale 15% off
    • Standard
      80 pages
      English language
    • sale 10% off
    • Standard
      87 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      90 pages
      English language
    • e-Library read for
      1 day

This document specifies a general laboratory test method for evaluating the reduction of formaldehyde
and other carbonyl compounds (aldehydes and ketones) concentrations by sorptive building materials.
This method applies to boards, wallpapers, carpets, paint products, and other building materials. The
sorption of those target compounds, i.e. formaldehyde and other carbonyl compounds, can be brought
about by adsorption, absorption and chemisorption.
The method specified in this document emp...
view more

    • sale 15% off
    • Standard
      28 pages
      French language
    • sale 15% off
    • Standard
      27 pages
      English language
    • sale 10% off
    • Standard
      33 pages
      English language
    • e-Library read for
      1 day

This document specifies the measurement methods and strategies for determining the PM2,5 mass
concentrations of suspended particulate matter (PM) in indoor air. It can also be used for determining
PM10 mass concentration.
The reference method principle consists of collecting PM2,5 on a filter after separation of the particles
by an impaction head and weighing them by means of a balance.
Measurement procedure and main requirements are similar to the conditions specified in EN 12341.
This do...
view more

    • sale 15% off
    • Standard
      12 pages
      English language
    • sale 10% off
    • Standard
      17 pages
      English language
    • e-Library read for
      1 day

This document specifies a general laboratory test method for evaluating the reduction in concentration
of VOCs by sorptive building materials. This method applies to boards, wallpapers, carpets, paint
products, and other building materials. The sorption of those target compound(s), i.e. VOCs, can be
brought about by adsorption, absorption and chemisorption. The performance of the material, with
respect to its ability to reduce the concentration of VOCs in indoor air, is evaluated by measurin...
view more

    • sale 15% off
    • Standard
      19 pages
      English language
    • sale 15% off
    • Standard
      20 pages
      French language
    • sale 10% off
    • Standard
      24 pages
      English language
    • e-Library read for
      1 day