This document specifies the testing methodology to be used for glass products that are claiming fire resistance. The methodology covers Type Testing as defined in the relevant glass product standard.
NOTE   This document provides guidance with the declaration of the characteristic, Safety in case of fire − Resistance to fire (for glass for use in a glazed assembly intended specifically for fire resistance) for the CE marking.
The same methodology can also be used to determine the performance cla...
view more

    • sale 10% off
    • Standard
      16 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      15 pages
      English language
    • e-Library read for
      1 day

This document specifies a test method for evaluating the reaction-to-fire performance of thermal insulating sandwich panel building systems for large rooms and the resulting flame spread on or within the thermal insulating sandwich panel building construction when it is exposed to heat from a simulated internal fire with flames impinging directly on its internal corner. The test method is not intended for evaluating a product's fire resistance. This document is applicable to both freestanding an...view more

    • sale 15% off
    • Draft
      16 pages
      English language
    • sale 15% off
    • Standard
      16 pages
      English language

This Part of (pr/Fpr)EN 15269, which should be read in conjunction with FprEN 15269-1, covers hinged and pivoted steel doorsets, hinged and pivoted timber doorsets (including timber framed glazed doorsets) and hinged and pivoted metal framed glazed doorsets of single or double-leaf construction.
The document prescribes the methodology for extending the application of test results obtained from test(s) conducted in accordance with EN 1634-3.
NOTE    It is anticipated that the above scope will be...
view more

    • sale 10% off
    • Standard
      193 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      183 pages
      English language
    • e-Library read for
      1 day

This Part of EN 1366 specifies a method for determining the fire resistance of vertical and horizontal ventilation ducts including those access panels, which are integral part of the tested ducts. The test examines the behaviour of ducts exposed to fire from the outside (duct A) and fire inside the duct (duct B). This Standard is used in conjunction with EN1363-1.
Annex A provides general guidance and gives background information.
This European Standard is not applicable to:
a)   ducts whos...
view more

    • sale 10% off
    • Standard
      50 pages
      English language
    • e-Library read for
      1 day

This document specifies the special provisions and safety rules describing the behaviour of lifts in the event of fire in a building, on the basis of a recall signal(s) to the lift(s) control system.
This document applies to new passenger lifts and goods passenger lifts with all types of drives. However, it may be used as a basis to improve the safety of existing passenger and goods passenger lifts.
This document does not apply to:
-   lifts which remain in use in the event of fire e.g. firefig...
view more

    • sale 10% off
    • Standard
      16 pages
      English language
    • e-Library read for
      1 day

This document specifies a test method for determining the non-combustibility performance, under
specified conditions, of homogeneous products and substantial components of non-homogeneous
products.
Information on the precision of the test method is given in Annex A.

    • sale 10% off
    • Standard
      39 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      36 pages
      English language
    • e-Library read for
      1 day

This document specifies a test method for determining the ability of a horizontal protective membrane, when used as a fire resistant barrier, to contribute to the fire resistance of standard horizontal structural building members as defined in 6.4.2.
Test of horizontal protective membrane installed under a specific non-standard floor should be tested according to EN 1365-2.
This document contains the fire test which specifies the tests which are carried out whereby the horizontal protective me...
view more

    • sale 10% off
    • Standard
      49 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      49 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies a fire test method and an assessment procedure for determining the contribution of fire protection systems to the fire resistance performance of circular and rectangular steel bars used as tension members.
This Standard applies to fire protection materials that have already been tested and assessed in accordance with EN 13381 4 or EN 13381-8 unless all the testing is carried out in accordance with Annex B using a minimum length of 2 000 mm. If testing to EN 1338...
view more

    • sale 10% off
    • Standard
      31 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      30 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies a method of test for determining the reaction to fire performance of construction products excluding floorings, and excluding products which are indicated in Table 1 of EC Decision 2000/147/EC, when exposed to thermal attack by a single burning item (SBI). The calculation procedures are given in Annex A. Information on the precision of the test method is given in Annex B. The calibration procedures are given in Annexes C and D, of which C is a normative annex.
N...
view more

    • sale 10% off
    • Standard
      104 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      121 pages
      English language
    • e-Library read for
      1 day

This document specifies a test method for determining the non-combustibility performance, under specified conditions, of homogeneous products and substantial components of non-homogeneous products. Information on the precision of the test method is given in Annex A.

    • sale 15% off
    • Standard
      32 pages
      French language
    • sale 15% off
    • Standard
      31 pages
      English language

This document sets out the general principles for the extended application of test results obtained on fire resisting and smoke control doorsets, e.g. the types of pedestrian and industrial doors, operable fabric curtains and openable windows listed in the Introduction above when tested in accordance with EN 1634-1 and/or EN 1634-3.
This document provides the general principles which are intended to be used in conjunction with the relevant part of EN 15269 depending upon the specific product ty...
view more

    • sale 10% off
    • Corrigendum
      2 pages
      English language
    • e-Library read for
      1 day

EN-ISO 11925-2 specifies a method of test for determining the ignitability ofproducts by direct small flame impingement under zero impressed irradiance usingvertically oriented test specimens. Information on the precision of the testmethod is given in Annex A (informative).Information on testing not essentiallyflat end-use products is given in Annex B (normative).Information on testingperforated end-use products is given in Annex C (normative).

    • sale 10% off
    • Standard
      36 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      33 pages
      English language
    • e-Library read for
      1 day

This document sets out the general principles for the extended application of test results obtained on fire resisting and smoke control doorsets, e.g. the types of pedestrian and industrial doors, operable fabric curtains and openable windows listed in the Introduction above when tested in accordance with EN 1634-1 and/or EN 1634-3.
This document provides the general principles which are intended to be used in conjunction with the relevant part of EN 15269 depending upon the specific product ty...
view more

    • sale 10% off
    • Corrigendum
      2 pages
      English language
    • e-Library read for
      1 day

This document specifies the apparatus and procedure for measuring reaction to fire behaviour under reduced oxygen atmospheres. Continuous measurements are made to calculate heat release rates, smoke and specific gas production rates, and mass loss rates. Ignition time measurements are also made and ignition behaviour is obtained. Pyrolysis parameters of specimens exposed to controlled levels of irradiance and controlled levels of oxygen supply can be determined as well. Different reduced oxygen ...view more

    • sale 15% off
    • Technical specification
      24 pages
      French language
    • sale 15% off
    • Technical specification
      23 pages
      English language

This document establishes the general principles for determining the fire resistance of various elements of construction when subjected to standard fire exposure conditions. Alternative and additional procedures to meet special requirements are given in EN 1363-2.
The principle that has been embodied within all European Standards relating to fire resistance testing is that where aspects and procedures of testing are common to all specific test methods e.g. the temperature/time curve, then they ...
view more

    • sale 10% off
    • Standard
      54 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      54 pages
      English language
    • e-Library read for
      1 day

This document specifies a method of test for determining the ignitability of products by direct small flame impingement under zero impressed irradiance using vertically oriented test specimens.
Information on the precision of the test method is given in Annex A (informative).
Information on testing not essentially flat end-use products is given in Annex B (normative).
Information on testing perforated end-use products is given in Annex C (normative).

    • sale 10% off
    • Standard
      36 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      33 pages
      English language
    • e-Library read for
      1 day

This document specifies a method of test for determining the ignitability of products by direct small flame impingement under zero impressed irradiance using vertically oriented test specimens. Information on the precision of the test method is given in Annex A (informative). Information on testing not essentially flat end-use products is given in Annex B (normative). Information on testing perforated end-use products is given in Annex C (normative).

    • sale 15% off
    • Standard
      28 pages
      French language
    • sale 15% off
    • Standard
      27 pages
      English language

This document establishes the general principles for determining the fire resistance of various elements of construction when subjected to standard fire exposure conditions. Alternative and additional procedures to meet special requirements are given in EN 1363-2.
The principle that has been embodied within all European standards relating to fire resistance testing is that where aspects and procedures of testing are common to all specific test methods e.g. the temperature/time curve, then they ...
view more

    • sale 10% off
    • Standard
      54 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      54 pages
      English language
    • e-Library read for
      1 day