This European Standard contains terms and definitions applications to CBRNE.
Common understanding and communication is important in the implementation of an effective CBRNE response and this communication will be most effective if there is common understanding of the terms used. Many of the terms and definitions listed here have been widely used for many years, while others are the result of cross-cutting experience of areas of CBRNE. The gradual evolution of our understanding of CBRNE and resp...
view more

    • sale 10% off
    • Standard
      101 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      103 pages
      English language
    • e-Library read for
      1 day

This document is for combined passive infrared and microwave detectors installed in buildings and provides for security Grades 1 to 4 (see EN 50131-1), specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV (see EN 50130-5). This document does not include requirements for detectors intended for use outdoors.
The purpose of the detector is to detect the broad spectrum infrared radiation emitted by an intruder, to emit microwave signals and analyse the signa...
view more

    • sale 10% off
    • Standard
      54 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      52 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies the requirements for Intrusion and Hold-up Alarm Systems installed in buildings using
specific or non-specific wired interconnections or wire-free interconnections. These requirements also apply to the
components of an I&HAS installed in a building which are normally mounted on the external structure of a building e.g.
ancillary control equipment or warning devices. The standard does not include requirements for exterior I&HAS.
This standard specifies perform...
view more

    • sale 10% off
    • Amendment
      11 pages
      English language
    • e-Library read for
      1 day

This document specifies the requirements for pyrotechnic obscuration security devices as a part of an I&HAS. It covers application and performance and also specifies the necessary tests and trials to ensure efficiency and reliability of such obscuration devices.
This European Standard is not intended to cover standalone or vehicular security pyrotechnic obscuration security device.
This European Standard also gives guidelines on the criteria for design, installation, operation and maintenance ...
view more

    • sale 10% off
    • Standard
      33 pages
      English language
    • e-Library read for
      1 day

This part of this European Standard specifies requirements for fire resisting data cabinets and diskette inserts.
Two methods of test are specified to determine the ability of fire resisting data cabinets to protect temperature and humidity sensitive contents from the effects of fire: a fire endurance test and a fire shock and impact test. Two levels of fire severity (S 60 and S 120) based upon time of fire exposure; and three protection classes (P, D and DIS) are specified using the maximum t...
view more

    • sale 10% off
    • Standard
      26 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      28 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies requirements for light fire storage units providing protection against fire.
The method of test is specified to determine the ability of light fire storage units to protect paper media from the effects of fire. Two levels of fire exposure periods (LFS 30 P and LFS 60 P) are specified using the maximum temperature increase permitted within the storage space of the light fire storage unit.
Requirements are also specified for the test specimen, the technical docu...
view more

    • sale 10% off
    • Standard
      17 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      17 pages
      English language
    • e-Library read for
      1 day

This document specifies requirements for fire resisting data cabinets and diskette inserts.
Two methods of test are specified to determine the ability of fire resisting data cabinets to protect temperature and humidity sensitive contents from the effects of fire: a fire endurance test and a fire shock and impact test. Two levels of fire severity (S 60 and S 120) based upon time of fire exposure; and three protection classes (P, D and DIS) are specified using the maximum temperature increases an...
view more

    • sale 10% off
    • Standard
      26 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      28 pages
      English language
    • e-Library read for
      1 day

This European Standard includes requirements for warning devices used for notification in intrusion and hold up alarm systems installed in buildings. Four grades of warning device are described corresponding to each of the four security grades given in EN 50131-1. Requirements are also given for four environmental classes covering applications in indoor and outdoor locations as specified in EN 50130-5.
This European Standard does not deal with requirements for compliance with EC regulatory Dire...
view more

    • sale 10% off
    • Standard
      36 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies the requirements for Security Fog Devices connected to an I&HAS. It covers application and performance and also gives the necessary tests and trials to ensure efficiency and reliability of such obscuration devices.
This European Standard also gives guidance on the criteria for design, installation, operation and maintenance of Security Fog Devices.
A Security Fog Device is not considered to be a component of an I&HAS and no requirements are given relating to th...
view more

    • sale 10% off
    • Standard
      30 pages
      English language
    • e-Library read for
      1 day

This document specifies requirements for light fire storage units providing protection against fire.
The method of test is specified to determine the ability of light fire storage units to protect paper media from the effects of fire. Two levels of fire exposure periods (LFS 30 and LFS 60) are specified using the maximum temperature increase permitted within the storage space of the light fire storage unit.
Protection after the fire exposure of 30 min (LFS 30) or 60 min (LFS 60) is not ensured...
view more

    • sale 10% off
    • Standard
      17 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      17 pages
      English language
    • e-Library read for
      1 day

This part of the European Standard EN 1047 specifies requirements for data rooms and data containers. It includes a method of test for the determination of the ability of data rooms and data containers to protect temperature and humidity sensitive data media (see 3.5) and hardware systems (see 3.6) from the effects of fire. A test method for measuring the resistance to mechanical stress (impact test) provided by data rooms type B and data containers is also specified.
Requirements are also spec...
view more

    • sale 10% off
    • Standard
      35 pages
      English language
    • e-Library read for
      1 day

This European Standard establishes the basis for testing and classifying free-standing safes, built-in safes (floor and wall), ATM safes and ATM bases, strongroom doors and strongrooms (with or without a door) according to their burglary resistance. This European Standard does not cover testing and classifying Deposit Systems and ATM systems.

    • sale 10% off
    • Standard
      54 pages
      English language
    • e-Library read for
      1 day

This European Standard establishes the basis for testing and classifying free-standing safes, built-in safes (floor and wall), ATM safes and ATM bases, strongroom doors and strongrooms (with or without a door) according to their burglary resistance. This European Standard does not cover testing and classifying Deposit Systems and ATM systems.

    • sale 10% off
    • Standard
      54 pages
      English language
    • e-Library read for
      1 day

This part of the European Standard EN 1047 specifies requirements for data rooms and data containers. It includes a method of test for the determination of the ability of data rooms and data containers to protect temperature and humidity sensitive data media (see 3.5) and hardware systems (see 3.6) from the effects of fire. A test method for measuring the resistance to mechanical stress (impact test) provided by data rooms type B and data containers is also specified.
Requirements are also spec...
view more

    • sale 10% off
    • Standard
      35 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies requirements for high security locks (HSL) for reliability, resistance to burglary and unauthorized opening with methods of testing. It also provides a scheme for classifying HSL in accordance with their assessed resistance to burglary and unauthorized opening.
It applies to mechanical and electronic HSL. The following features may be included as optional subjects but they are not mandatory:
a)   recognized code for preventing code altering and/or enabling/disabl...
view more

    • sale 10% off
    • Standard
      55 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies requirements for high security locks (HSL) for reliability, resistance to burglary and unauthorized opening with methods of testing. It also provides a scheme for classifying HSL in accordance with their assessed resistance to burglary and unauthorized opening.
It applies to mechanical and electronic HSL. The following features may be included as optional subjects but they are not mandatory:
a)   recognized code for preventing code altering and/or enabling/disabl...
view more

    • sale 10% off
    • Standard
      55 pages
      English language
    • e-Library read for
      1 day

This European Standard provides for security grades 1 to 4, (see EN 50131-1) specific or non-specific wired or wire-free lock state contacts, and includes the requirements for four environmental classes covering applications in internal and outdoor locations as specified in EN 50130-5.
Lock state contacts are installed in windows or doors and windows or doorframes to allow to monitor the lock/unlock status only or the lock/unlock status combined with the open/close status of a window/door simul...
view more

    • sale 10% off
    • Standard
      32 pages
      English language
    • e-Library read for
      1 day

This Technical Specification provides guidance for managing security of (high risk) chemical, biological, radioactive, nuclear or Explosive materials, such as those covered by the EU CBRN action plan, that are used within healthcare facilities (HCF); it covers the lifecycle of such materials within a HCF’s span of control. In this Technical Specification these materials are referred to as ‘CBRNE materials’.
It covers the protection of (high risk) CBRNE materials used in healthcare facilities ag...
view more

    • sale 10% off
    • Technical specification
      37 pages
      English language
    • e-Library read for
      1 day

This Technical Specification provides guidance for managing security of (high risk) chemical, biological, radioactive, nuclear or Explosive materials, such as those covered by the EU CBRN action plan, that are used within healthcare facilities (HCF); it covers the lifecycle of such materials within a HCF’s span of control. In this Technical Specification these materials are referred to as ‘CBRNE materials’.
It covers the protection of (high risk) CBRNE materials used in healthcare facilities ag...
view more

    • sale 10% off
    • Technical specification
      37 pages
      English language
    • e-Library read for
      1 day

ISO/IEC 20243-1:2018 (O-TTPS) is a set of guidelines, requirements, and recommendations that address specific threats to the integrity of hardware and software COTS ICT products throughout the product life cycle. This release of the Standard addresses threats related to maliciously tainted and counterfeit products. The provider's product life cycle includes the work it does designing and developing products, as well as the supply chain aspects of that life cycle, collectively extending through t...view more

    • sale 15% off
    • Standard
      32 pages
      English language