This part of IEC 62561 specifies the requirements and tests for metallic connection
components that form part of a lightning protection system (LPS). Typically, these can be
connectors, clamps, bonding and bridging components, expansion pieces and test joints.
For the purposes of this document the following connection types are considered as
connection components: exothermic, brazing, welding, clamping, crimping, seaming, screwing
or bolting.
Testing of components for an explosive atmosphere is not covered by this document.

  • Standard
    32 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60352 is applicable to insulation piercing connections made with stranded wires
and tinsel wires, insulated flat conductors and flat flexible circuitries for use in electrical and
electronic equipment.
Information on materials and data from industrial experience is included in addition to the test
procedures to provide electrically stable connections under prescribed environmental
conditions.
The object of this document is to:
– determine the suitability of insulation piercing connections under specified mechanical,
electrical, and atmospheric conditions;
– provide a means of comparing test results when the tools used to make the connections, if
any, are of different designs or manufacture.
There are different designs and materials for insulation piercing terminations in use. For this
reason, only fundamental parameters of the termination, the performance requirements of the
conductor and the complete connection are specified in this document.

  • Standard
    38 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60352-6:2022 This part of IEC 60352 is applicable to insulation piercing connections made with stranded wires and tinsel wires, insulated flat conductors and flat flexible circuitries for use in electrical and electronic equipment. Information on materials and data from industrial experience is included in addition to the test procedures to provide electrically stable connections under prescribed environmental conditions. The object of this document is to:  determine the suitability of insulation piercing connections under specified mechanical, electrical, and atmospheric conditions; provide a means of comparing test results when the tools used to make the connections, if any, are of different designs or manufacture.

  • Standard
    38 pages
    English language
    sale 10% off
    e-Library read for
    1 day

NEXT ACTION: PUBLICATION EXPECTED BY 2020-04

  • Amendment
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60352-6:2022 This part of IEC 60352 is applicable to insulation piercing connections made with stranded wires and tinsel wires, insulated flat conductors and flat flexible circuitries for use in electrical and electronic equipment.
Information on materials and data from industrial experience is included in addition to the test procedures to provide electrically stable connections under prescribed environmental conditions.
The object of this document is to:
determine the suitability of insulation piercing connections under specified mechanical, electrical, and atmospheric conditions;
provide a means of comparing test results when the tools used to make the connections, if any, are of different designs or manufacture.

  • Standard
    70 pages
    English and French language
    sale 15% off

This International Standard specifies requirements and tests for cable cleats used for securing cables in electrical installations and for intermediate restraints used for holding cables together in formation in electrical installations. Cable cleats provide resistance to electromechanical forces where declared. This standard includes cable cleats that rely on a mounting surface specified by the manufacturer for axial and/or lateral retention of cables.
NOTE Requirements for manufacturers in this document also apply to importers and responsible vendors where appropriate.
This standard does not apply to cable ties.

  • Standard
    45 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This International Standard specifies requirements and tests for cable cleats used for securing cables in electrical installations and for intermediate restraints used for holding cables together in formation in electrical installations. Cable cleats provide resistance to electromechanical forces where declared. This document includes cable cleats that rely on a mounting surface specified by the manufacturer for axial and/or lateral retention of cables. Various types of cable cleats and intermediate restraints are shown in Annex A. NOTE Requirements for manufacturers in this document also apply to importers and responsible vendors where appropriate. This document does not apply to cable ties.

  • Standard
    45 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Not available

  • Amendment
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2020-07-20: This prAA represents common mods to EN 61534-22:2014/prA1 (PR=72289)

  • Amendment
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2020-07-20: This prAA represents common mods to EN 61534-21:2014/prA1 (PR=72286)

  • Amendment
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61914:2021 specifies requirements and tests for cable cleats used for securing cables in electrical installations and for intermediate restraints used for holding cables together in formation in electrical installations. Cable cleats provide resistance to electromechanical forces where declared. This document includes cable cleats that rely on a mounting surface specified by the manufacturer for axial and/or lateral retention of cables.
This third edition cancels and replaces the second edition published in 2015. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:  
requirements for mandrels used in testing rationalised and detailed in the general test requirements (Clause 5);
definition of liner added and test requirements where liners and other optional parts are used;
definitions for LV, MV and HV cables added and test requirements where MV & HV cable are used ;
new corrosion resistance classes for plated products added;
new requirements and test for durability and legibility of markings added;
new test requirements for axial load testing of cleats for more than one cable added;
lateral load test requirements for intermediate restraints added.

  • Standard
    78 pages
    English and French language
    sale 15% off

2020-07-20: This prAA represents common mods to EN 61534-21:2014/prA1 (PR=72286)

  • Amendment
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Not available

  • Amendment
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2020-07-20: This prAA represents common mods to EN 61534-22:2014/prA1 (PR=72289)

  • Amendment
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

To complete the text of EN 61995-1:2008/A1:2017 (PR=60113) with common modification for Europe and Annex ZZ for LVD.

  • Amendment
    7 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2019-08-27 PC: sent for LVD assessment

  • Amendment
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

To complete the text of EN 61995-1:2008/A1:2017 (PR=60113) with common modification for Europe and Annex ZZ for LVD.

  • Amendment
    7 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2018-09-14 PeC: Cited under the LVD in C 326/02
20180129: BT decision D139/C142 for implementation dates

  • Amendment
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

NEW!IEC 60320-2-4:2018 is available as IEC 60320-2-4:2018 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60320-2-4:2018 is applicable to two-pole appliance couplers for alternating current only, with or without earthing contact, with a rated voltage not exceeding 250 V and a rated current not exceeding 16 A, for household and similar general purposes and intended for incorporation or integration within electric appliances or other electric equipment of multi‑part construction for 50 Hz or 60 Hz supply which depend on the weight of the appliance to ensure correct engagement. This second edition cancels and replaces the first edition published in 2005 and Amendment 1:2009. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - IEC 60320-2-4 is aligned with IEC 60320-1:2015. - IEC 60320-2-4 is aligned with IEC 60335-1 and IEC 60335-2-15. IEC 60320-2-4 appliance couplers are incorporated into appliances designed and manufactured to these standards. To this end, particular attention is drawn to 14.2 and Clause 20. - It also now proposes that appliance couplers with auxiliary contacts be considered.

  • Standard
    42 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60352-7:2020 is available as IEC 60352-7:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.

IEC 60352-7:2020 is applicable to spring clamp connections made with stripped wire without further preparation:
- solid conductors of 0,32 mm to 3,7 mm nominal diameter (0,08 mm2 to 10 mm2 cross‑section), or
- stranded conductors of 0,08 mm2 to 10 mm2 cross-section, or
- flexible conductors of 0,08 mm2 to 10 mm2 cross-section,
according to IEC 60228 or IEC 60189-3 for use in electrical and electronic equipment and components.
Information on materials and data from industrial experience is included in addition to the test procedures to provide electrically stable connections under prescribed environmental conditions. The object of this document is to determine the suitability of spring clamp connections under specified mechanical, electrical and atmospheric conditions. This second edition cancels and replaces the first edition of IEC 60352-7, published in 2002. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) correction of the two flow charts in Figure 6 and Figure 7,
b) split the content into more clauses for better separation between full test schedule and basic test schedule,
c) relocating the content of former Clause 6 Practical guidance into an informative Annex A, as now common in the IEC 60352 series for solderless connections,
d) clarification on conductor types with reference to classes defined in IEC 60228.

  • Standard
    34 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60352 is applicable to solderless press-in connections for use in electrical
and electronic equipment and components.
The press-in connection consists of a termination having a suitable press-in zone which is
inserted into a hole of a board.
Information on materials and data from industrial experience is included in addition to the test
procedures to provide electrically stable connections under specified environmental conditions.
The object of this document is to determine the suitability of press-in connections under
mechanical, electrical and atmospheric conditions as specified by the manufacturer of the
press-in termination and to provide a means of comparing test results when the tools used to
make the connections are of different designs or manufacture.

  • Standard
    38 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60352-4:2020 is applicable to non-accessible ID connections for which the tests and measurements according to Clauses 6 through 8 are suitable and which are made with:
– appropriately designed ID terminations;
– wires having solid round conductors of 0,25 mm to 3,6 mm nominal diameter;
– wires having stranded conductors of 0,05 mm2 to 10 mm2 cross-sectional area;
for use in electrical and electronic equipment and components.
Information on materials and data from industrial experience is included in addition to the test procedures to provide electrically stable connections under prescribed environmental conditions.
There are different designs and materials for ID terminations in use. For this reason, only fundamental parameters of the termination are specified, while the performance requirements of the wire and the complete connection are specified in full detail.
The purpose of this document is:
– to determine the suitability of non-accessible ID connections under specified mechanical, electrical and atmospheric conditions;
– to provide a means of comparing test results when the tools used to make the connections, if any, are of different designs or manufacture.
This second edition cancels and replaces the first edition, published in 1994, and its Amendment 1 (2000). This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) Transferred Clauses 9 to 13 into Annex A (informative).
b) The figures were re-drawn for clarity.

  • Standard
    47 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60352-4:2020 is applicable to non-accessible ID connections for which the tests and measurements according to Clauses 6 through 8 are suitable and which are made with: – appropriately designed ID terminations; – wires having solid round conductors of 0,25 mm to 3,6 mm nominal diameter; – wires having stranded conductors of 0,05 mm2 to 10 mm2 cross-sectional area; for use in electrical and electronic equipment and components. Information on materials and data from industrial experience is included in addition to the test procedures to provide electrically stable connections under prescribed environmental conditions. There are different designs and materials for ID terminations in use. For this reason, only fundamental parameters of the termination are specified, while the performance requirements of the wire and the complete connection are specified in full detail. The purpose of this document is: – to determine the suitability of non-accessible ID connections under specified mechanical, electrical and atmospheric conditions; – to provide a means of comparing test results when the tools used to make the connections, if any, are of different designs or manufacture. This second edition cancels and replaces the first edition, published in 1994, and its Amendment 1 (2000). This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) Transferred Clauses 9 to 13 into Annex A (informative). b) The figures were re-drawn for clarity.

  • Standard
    47 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60352-4:2020 is applicable to non-accessible ID connections for which the tests and measurements according to Clauses 6 through 8 are suitable and which are made with:
– appropriately designed ID terminations;
– wires having solid round conductors of 0,25 mm to 3,6 mm nominal diameter;
– wires having stranded conductors of 0,05 mm2 to 10 mm2 cross-sectional area;
for use in electrical and electronic equipment and components.
Information on materials and data from industrial experience is included in addition to the test procedures to provide electrically stable connections under prescribed environmental conditions.
There are different designs and materials for ID terminations in use. For this reason, only fundamental parameters of the termination are specified, while the performance requirements of the wire and the complete connection are specified in full detail.
The purpose of this document is:
– to determine the suitability of non-accessible ID connections under specified mechanical, electrical and atmospheric conditions;
– to provide a means of comparing test results when the tools used to make the connections, if any, are of different designs or manufacture.
This second edition cancels and replaces the first edition, published in 1994, and its Amendment 1 (2000). This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) Transferred Clauses 9 to 13 into Annex A (informative).
b) The figures were re-drawn for clarity.

  • Standard
    85 pages
    English and French language
    sale 15% off

This part of IEC 60352 is applicable to ID connections which are accessible for tests and
measurements according to Clauses 6 through 8 and which are made with:
– appropriately designed accessible ID terminations,
– wires having solid round conductors of 0,25 mm to 3,6 mm nominal diameter,
– wires having stranded conductors of 0,05 mm2 to 10 mm2 cross-sectional area,
for use in electrical and electronic equipment and components.
Information on materials and data from industrial experience is included in addition to the test
procedures to provide electrically stable connections under prescribed environmental conditions.
There are different designs and materials for accessible ID terminations in use. For this reason
only fundamental parameters of the termination are specified, while the performance requirements
of the wire and the complete connection are specified in full detail.
The purpose of this document is:
– to determine the suitability of accessible ID connections under specified mechanical, electrical
and atmospheric conditions;
– to provide a means of comparing test results when the tools used to make the connections,
if any, are of different designs or manufacture.

  • Standard
    44 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60352-3:2020 is applicable to ID connections which are accessible for tests and measurements according to Clauses 6 through 8 and which are made with: – appropriately designed accessible ID terminations, – wires having solid round conductors of 0,25 mm to 3,6 mm nominal diameter, – wires having stranded conductors of 0,05 mm2 to 10 mm2 cross-sectional area, for use in electrical and electronic equipment and components. Information on materials and data from industrial experience is included in addition to the test procedures to provide electrically stable connections under prescribed environmen-tal conditions. There are different designs and materials for accessible ID terminations in use. For this reason only fundamental parameters of the termination are specified, while the perfor-mance requirements of the wire and the complete connection are specified in full detail. The purpose of this document is: – to determine the suitability of accessible ID connections under specified mechanical, electrical and atmospheric conditions; – to provide a means of comparing test results when the tools used to make the con-nections, if any, are of different designs or manufacture. This second edition cancels and replaces the first edition published in 1993. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the pre-vious edition: a) Subclause 7.2.2: reduce the limit of duration of contact disturbance to 1 µs. b) Subclause 7.2.3: reduce the limit of duration of contact disturbance to 1 µs. c) Transferred Clauses 9 to 13 to Annex A (informative). d) The figures were revised for clarity.

  • Standard
    44 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2017-05-02: D156/C084 - Ratified standards not being made available.
2017-03-28: BT decided to have this standard published (D156/C084)
2016-11-23: includes common modifications from 63999

  • Amendment
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60352-3:2020 is applicable to ID connections which are accessible for tests and measurements according to Clauses 6 through 8 and which are made with:
– appropriately designed accessible ID terminations,
– wires having solid round conductors of 0,25 mm to 3,6 mm nominal diameter,
– wires having stranded conductors of 0,05 mm2 to 10 mm2 cross-sectional area,
for use in electrical and electronic equipment and components.
Information on materials and data from industrial experience is included in addition to the test procedures to provide electrically stable connections under prescribed environmen-tal conditions.
There are different designs and materials for accessible ID terminations in use. For this reason only fundamental parameters of the termination are specified, while the perfor-mance requirements of the wire and the complete connection are specified in full detail.
The purpose of this document is:
– to determine the suitability of accessible ID connections under specified mechanical, electrical and atmospheric conditions;
– to provide a means of comparing test results when the tools used to make the con-nections, if any, are of different designs or manufacture.
This second edition cancels and replaces the first edition published in 1993. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the pre-vious edition:
a) Subclause 7.2.2: reduce the limit of duration of contact disturbance to 1 µs.
b) Subclause 7.2.3: reduce the limit of duration of contact disturbance to 1 µs.
c) Transferred Clauses 9 to 13 to Annex A (informative).
d) The figures were revised for clarity.

  • Standard
    81 pages
    English and French language
    sale 15% off

This part of EN 61238 applies to compression and mechanical connectors for power cables for rated voltages up to 1 kV (Um = 1,2 kV), for example buried cables or cables installed in buildings, having
a)   conductors complying with EN 60228 having nominal cross-sectional areas between 2,5 mm2 and 1 200 mm2 for copper and between 16 mm2 and 1 200 mm2 for aluminium;
b)   a maximum continuous conductor temperature not exceeding 90 °C.
This document is not applicable to connectors for overhead line conductors nor to connectors with a sliding contact.
The object of this document is to define the type test methods and requirements which apply to compression and mechanical connectors for power cables with copper or aluminium conductors. The reference method is to perform the tests on unused conductors.

  • Standard
    44 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    44 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 61238 applies to compression and mechanical connectors for power cables for rated voltages above 1 kV (Um = 1,2 kV) up to 36 kV (Um = 42 kV), for example buried cables or cables installed in buildings, having
a) conductors complying with EN 60228 having nominal cross-sectional areas between 2,5 mm2 and 1 200 mm2 for copper and between 16 mm2 and 1 200 mm2 for aluminium, excluding Milliken conductors;
b) a maximum continuous conductor temperature not exceeding 90 °C.
This document is not applicable to connectors for overhead line conductors nor to connectors with a sliding contact.
The object of this document is to define the type test methods and requirements which apply to compression and mechanical connectors for power cables with copper or aluminium conductors. The reference method is to perform the tests on unused conductors.

  • Amendment
    3 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    3 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 61238 applies to insulation piercing connectors for power cables for rated voltages up to 1 kV (Um = 1,2 kV), for example according to HD 603 or other buried cables and cables installed in buildings, having
a) conductors complying with EN 60228 having nominal cross-sectional areas between 2,5 mm2 and 300 mm2 for copper and between 16 mm2 and 500 mm2 for aluminium,
b) a maximum continuous cable temperature not exceeding the insulation material properties.
This document is not applicable to connectors for overhead line conductors nor to connectors with a sliding contact.  
The object of this document is to define the type test methods and requirements, which apply to insulation piercing connectors for power cables with copper or aluminium conductors. The reference method is to perform the tests on unused insulated conductors.

  • Standard
    58 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    58 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 61238 applies to compression and mechanical connectors for power cables for rated voltages above 1 kV (Um = 1,2 kV) up to 36 kV (Um = 42 kV), for example buried cables or cables installed in buildings, having
a) conductors complying with EN 60228 having nominal cross-sectional areas between 2,5 mm2 and 1 200 mm2 for copper and between 16 mm2 and 1 200 mm2 for aluminium, excluding Milliken conductors;
b) a maximum continuous conductor temperature not exceeding 90 °C.
This document is not applicable to connectors for overhead line conductors nor to connectors with a sliding contact.
The object of this document is to define the type test methods and requirements which apply to compression and mechanical connectors for power cables with copper or aluminium conductors. The reference method is to perform the tests on unused conductors.

  • Standard
    47 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    47 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61995-2:2009 which is to be read in conjunction with IEC 61995-1, applies to devices for the connection of luminaires (DCL) 250 V, 6 A a.c. intended for household and similar purposes, for the electrical connection to final circuits rated not more than 16 A, without providing mechanical support for the luminaire. This publication is to be read in conjunction with IEC 61995-1:2005.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61914:2015 is available as IEC 61914:2015 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 61914:2015 specifies requirements and tests for cable cleats and intermediate restraints used for securing cable in electrical installations. Cable cleats provide resistance to electromechanical forces where declared. This standard includes cable cleats that rely on a mounting surface specified by the manufacturer for axial and/or lateral retention of cables. This second edition cancels and replaces the first edition published in 2009. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) Additional declaration and test for lateral load retention depending on cleat mounting orientation with associated new figures; b) Additional declaration of the distance between the cable centres in any short-circuit test and associated new figures; c) Specification of the cable to be used in short-circuit testing and relaxation of the ambient temperature limits for the test; d) Additional requirement to photograph the short-circuit test arrangement before and after the test and to record more complete details of the cable used; e) Revised parameters for the test of resistance to UV light. This edition also includes the following editorial changes with respect to the previous edition: f) Revised and updated normative references and bibliography; g) Editorial clarification of definitions; h) Editorial clarification of procedures for selection of test samples and the testing of cleats designed for more than one cable; i) Relaxation of some mandrel material requirements; j) Clarification of the inspection requirements following a short-circuit test and adding the option of either a.c. or d.c. voltage testing following a second short-circuit; k) Clarification that the resistance to corrosion test applies to all types of fixing; l) New cleat example illustration; m) Limitations of use of the formulae in Annex B added.

  • Standard
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard was amended to correct some references in the annexes.

  • Amendment
    3 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard details the performance requirements and the test methods for type testing of cable accessories for use with power distribution cables of rated voltage 0,6/1,0 (1,2) kV as defined in HD 603 or other relevant cable standards. Cable accessories covered by this European Standard include joints, stop ends and outdoor terminations for extruded solid dielectric insulated cables and transition joints between extruded solid dielectric insulated and impregnated paper insulated cables. Joints, stop ends and outdoor terminations for impregnated paper insulated cables are not included. The service operating conditions of accessories should be compatible with the service operating conditions of cables on which they are to be installed. Accessories for special applications such as submarine, shipboard, explosive or seismic environments, or where specified fire performance characteristics are required, are not included. NOTE 1 This European Standard does not invalidate existing approvals of products achieved on the basis of national standards and specifications and/or the demonstration of satisfactory service performance. However, products approved according to such national standards or specifications cannot directly claim approval to this European standard. NOTE 2 It may be possible, subject to agreement between supplier and purchaser, and/or the relevant conformity assessment body, to demonstrate that conformity to the earlier standard can be used to claim conformity to this European Standard, provided an assessment is made of any additional type testing that may need to be carried out. Any such additional testing that is part of a sequence of testing cannot be done separately.

  • Standard
    37 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    37 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    36 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62986:2017(E) sets the general and dimensional interchangeability requirements for plugs, socket-outlets, connectors and appliance inlets with arcuate contacts of standardized configurations (hereinafter referred to as accessories), with a rated operating voltage not exceeding 600 V AC at a frequency of 50 Hz and 60 Hz and with rated currents of 20 A and 30 A, primarily intended for commercial use indoors, in conditions where the presence of water is negligible.

  • Standard
    88 pages
    English language
    sale 15% off

2017-05-02: D156/C084 - Ratified standards not being made available.
2017-03-28: BT decided to have this standard published (D156/C084)
2016-11-23: includes common modifications from 63999

  • Amendment
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 62561 specifies the requirements and tests for metallic connection
components that form part of a lightning protection system (LPS). Typically, these can be
connectors, clamps, bonding and bridging components, expansion pieces and test joints.
For the purposes of this document the following connection types are considered as
connection components: exothermic, brazing, welding, clamping, crimping, seaming, screwing
or bolting.
Testing of components for an explosive atmosphere is not covered by this document.

  • Standard
    28 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61534-21:2014 specifies the particular requirements and tests for PT systems intended for mounting on walls and/or ceiling. They may be installed flush or semi-flush, surface mounted, suspended or spaced away from the surface using fixing devices. This second edition cancels and replaces the first edition published in 2006 and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - Clauses 18 to 22 have been adapted to IEC 61534-1:2011 and include short-circuit test requirements; - Additional classification, terms and requirements for wall powertrack (PT) systems mounted at the skirting level (close to the floor) position. This publication is to be read in conjunction with IEC 61534-1:2011.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61534-22:2014 specifies the particular requirements and tests for PT systems intended for mounting on, or under the floor level and floor service units which are mounted on the floor, under the floor or flush with the floor. This second edition cancels and replaces the first edition published in 2009. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - Clauses 18 to 22 have been adapted to IEC 61534-1:2011 and include short-circuit test requirements; - addition of a new (500 N) classification for the resistance to traffic load applied to small surface areas on a flushfloor service unit; - addition of a new classification for the non-automatic closing of the lid on flushfloor service units and appropriate tests; - addition of tests for floor service units declared for use when a floor is wet treated. This publication is to be read in conjunction with IEC 61534-1:2011.

  • Standard
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2020-10-02: EC formal rejection from citation LVD 2014/35/EU
2019-09-26 PeC: cannot be cited for LVD, Annex ZZ is not in the right format
2017-05-02: D156/C084 - Ratified standards not being made available.

  • Amendment
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2020-10-02: EC formal rejection from citation LVD 2014/35/EU
2019-09-26 PeC: cannot be cited for LVD, Annex ZZ is not in the right format
2017-05-02: D156/C084 - Ratified standards not being made available.

  • Amendment
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day