This European Standard specifies requirements for the interaction between pantographs and overhead contact lines, to achieve to achieve free access.
NOTE   These requirements are defined for a limited number of pantograph types, referred to as an 'interoperable pantograph' according to 5.3, together with the geometry and characteristics of compatible overhead contact lines.
This European Standard describes parameters and values for planned and future lines.
Annex B gives some parameters for exi...
view more

    • sale 10% off
    • Standard
      74 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      67 pages
      English language
    • e-Library read for
      1 day

Unchanged with respect to the current edition CLC/TS 50238-2:2015.
Scope of the revision:
- to include the corrigendum CLC/TS 50238-2:2015/AC:2016-07,
- to correct editorial errors and to align definition of terms with EN 50238 series, EN 50617 series, IEV 60050-
811:2017 and IEV 60050-821:2017,
- to update Annex A "Interference current limits for Rolling Stock"
- to review the need of Annex B "Rolling Stock Interference Evaluation methods"

    • sale 10% off
    • Technical specification
      43 pages
      English language
    • e-Library read for
      1 day

For the purpose of demonstrating compatibility between rolling stock and axle counter detectors, this document defines the interference limits and evaluation methods to verify rolling stock emissions. Wheel sensors and crossing loops are not covered by this document.
This document gives recommended individual limits to be applied to establish compatibility between RST and all selected types of axle counter detectors, including any covered by national standards.
The list of selected types of ax...
view more

    • sale 10% off
    • Technical specification
      14 pages
      English language
    • e-Library read for
      1 day

In addition to the general requirements of IEC 60077-2, this part of IEC 60077 gives rules for
AC circuit-breakers, the main contacts of which are connected to AC overhead contact lines;
the nominal voltage of these circuits being in accordance with IEC 60850.
This document, together with IEC 60077-2, states specifically:
a) the characteristics of the circuit-breakers;
b) the service conditions with which circuit-breakers comply with reference to:
– operation and behaviour in normal servic...
view more

    • sale 10% off
    • Standard
      33 pages
      English language
    • e-Library read for
      1 day

This European Standard applies to electric traction overhead contact line systems in heavy railways, light railways, trolley busses and industrial railways of public and private operators.
It applies to new installations of overhead contact line systems and for the complete reconstruction of existing overhead contact line systems.
This standard contains the requirements and tests for the design of overhead contact lines, requirements for structures and their structural calculations and verific...
view more

    • sale 10% off
    • Standard
      108 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      95 pages
      English language
    • e-Library read for
      1 day

In addition to the general requirements of NEN-EN-IEC 60077-2, NEN-EN-IEC 60077-3 gives the rules for circuit-breakers, the main contacts of which are connected to DC power and/or auxiliary circuits. The nominal voltage of these circuits does not exceed 3 000 V DC according to IEC 60850. This part of IEC 60077, together with IEC 60077-2, states specifically: a) the characteristics of the circuit-breakers; b) the service conditions with which circuit-breakers complies with reference to: - operati...view more

    • sale 10% off
    • Standard
      32 pages
      English language
    • e-Library read for
      1 day

The purpose of NEN-EN-IEC 60077-5 is to give additional or amended rules for high voltage (HV) fuses as a supplement to those given by IEC 60077-2. The high voltage fuses concerned are those connected into power and/or auxiliary circuits. The nominal voltage of these circuits lies between 600 V DC and 3 000 V DC, according to IEC 60850. These fuses can also be used in auxiliary AC circuits up to a nominal voltage of 1500 V. This document together with IEC 60077-2 states specifically: a) the char...view more

    • sale 10% off
    • Standard
      32 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies requirements for the acceptance of simulation tools used for the assessment of design of traction power supply systems.
The simulation results allow the calculation of quality indexes requested by EN 50388:2012, Clause 8.
This European Standard is applicable to the simulation of AC and DC traction power supply systems, including lines defined in the TSIs.
This European Standard does not deal with validation of simulation tools by measurement.
The minimum requ...
view more

    • sale 10% off
    • Standard
      69 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      107 pages
      English language
    • e-Library read for
      1 day

This document applies to overhead contact line systems in heavy railways, light railways, trolley buses and industrial railways of public and private operators. This document applies to new installations of overhead contact line systems and for the complete renewal of existing overhead contact line systems. This document contains the requirements and tests for the design of overhead contact lines, requirements for structures and their structural calculations and verifications as well as the requ...view more

    • sale 10% off
    • Standard
      108 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      95 pages
      English language
    • e-Library read for
      1 day

This document specifies requirements for the acceptance of simulation tools used for the assessment of design of electric traction power supply systems with respect to TSI Energy. This document is applicable to the simulation of AC and DC electric traction power supply systems, in the frame of assessment required by Directive (EU) 2016/797. The methods and parameters defined in this document are only intended for use in the design of the electric traction power supply system, and hence this docu...view more

    • sale 10% off
    • Standard
      69 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      107 pages
      English language
    • e-Library read for
      1 day

IEC 60077-3:2019 is available as IEC 60077-3:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60077-3:2019 gives the rules for circuit-breakers, the main contacts of which are connected to DC power and/or auxiliary circuits. The nominal voltage of these circuits does not exceed 3 000 V DC according to IEC 60850. This part of IEC 60077, together with IEC 60077-2, states specifically: a) th...view more

    • sale 10% off
    • Standard
      32 pages
      English language
    • e-Library read for
      1 day

This European Standard applies to emission and immunity aspects of EMC for electrical and electronic apparatus and systems intended for use in railway fixed installations for power supply. This includes the power feed to the apparatus, the apparatus itself with its protective control circuits, trackside items such as switching stations, power autotransformers, booster transformers, substation power switchgear and power switchgear to other longitudinal and local supplies.
Filters operating at ra...
view more

    • sale 10% off
    • Amendment
      3 pages
      English language
    • e-Library read for
      1 day

For the purpose of demonstrating compatibility between rolling stock and axle counter detectors, this document defines the interference limits and evaluation methods to verify rolling stock emissions. Wheel sensors and crossing loops are not covered by this document. This document gives recommended individual limits to be applied to establish compatibility between RST and all selected types of axle counter detectors, including any covered by national standards. The list of selected types of axle...view more

    • sale 10% off
    • Technical specification
      14 pages
      English language
    • e-Library read for
      1 day

Simulation techniques are used to assess the dynamic interaction between overhead contact lines and pantographs, as part of the prediction of current collection quality. This European Standard specifies functional requirements for the validation of such simulation methods to ensure confidence in, and mutual acceptance of the results of the simulations.
This standard deals with:
-   input and output parameters of the simulation,
-   comparison with line test measurements, and the characteristics o...
view more

    • sale 10% off
    • Standard
      87 pages
      English language
    • e-Library read for
      1 day

This European Standard applies to signalling and telecommunication apparatus that is installed inside the railway environment. Signalling and telecommunication apparatus mounted in vehicles is covered by EN 50121-3-2:2016, signalling and telecommunication apparatus installed inside the substation and connected to substation equipment is covered by EN 50121-5:2016. This European Standard specifies limits for emission and immunity and provides performance criteria for signalling and telecommunicat...view more

    • sale 10% off
    • Amendment
      3 pages
      English language
    • e-Library read for
      1 day

This European Standard applies to emission and immunity aspects of EMC for electrical and electronic apparatus and systems intended for use in railway fixed installations for power supply. This includes the power feed to the apparatus, the apparatus itself with its protective control circuits, trackside items such as switching stations, power autotransformers, booster transformers, substation power switchgear and power switchgear to other longitudinal and local supplies. Filters operating at rai...view more

    • sale 10% off
    • Amendment
      3 pages
      English language
    • e-Library read for
      1 day

Simulation techniques are used to assess the dynamic interaction between overhead contact lines and pantographs, as part of the prediction of current collection quality. This document specifies functional requirements for the validation of such simulation methods to ensure confidence in, and mutual acceptance of the results of the simulations. This document deals with: - input and output parameters of the simulation; - comparison with line test measurements, and the characteristics of those line...view more

    • sale 10% off
    • Standard
      87 pages
      English language
    • e-Library read for
      1 day

This Technical Report provides recommendations for DC reversible substations. These recommendations apply
to systems and components that facilitate the flow of energy to and from the upstream AC grid including their
related interfaces.
These recommendations provide the necessary functions for the recovery of braking energy. It is intended to be
used in fixed electrical installations with nominal voltage not exceeding 3 000 V DC which supply electrical
power to vehicles used in public guided...
view more

    • sale 10% off
    • Technical report
      21 pages
      English language
    • e-Library read for
      1 day