IEC 60384-16:2019 applies to fixed capacitors with metallized electrodes and poly­propylene dielectric for use in electronic equipment. These capacitors can have "self-healing properties" depending on conditions of use. They are mainly intended for use with direct voltage. Capacitors for alternating voltage and pulse applications are not included, but are covered by IEC 60384-17. Capacitors for electromagnetic interference suppression are not included, but are covered by IEC 60384-14. Capacitors for electrical shock hazard protection (covered by IEC 60065) and fluorescent lamp and motor capacitors are also excluded.

  • Standard
    40 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60384-11:2019 is applicable to fixed direct current capacitors, for rated voltages not exceeding 6 300 V, using as dielectric a polyethylene-terephthalate film and electrodes of thin metal foils. For capacitors with rated voltages exceeding 1 000 V, additional tests and requirements may be specified in the detail specification. The capacitors covered by this document are intended for use in electronic equipment. Capacitors for electromagnetic interference suppression are not included, but are covered by IEC 60384‑14. The object of this document is to prescribe preferred ratings and characteristics and to select from IEC 60384-1:2016 the appropriate quality assessment procedures, tests and measuring methods and to give general performance requirements for this type of capacitor. Test severities and requirements prescribed in detail specifications referring to this sectional specification are of an equal or higher performance level. Lower performance levels are not permitted. This edition includes the following significant technical changes with respect to the previous edition: a) revision of all parts of the document based on the ISO/IEC Directives, Part 2:2018, and harmonization with other similar kinds of documents; b) the document structure has been organized to follow new sectional specification structure decided in TC 40; c) revised tables and Clause 5 so as to prevent duplications and contradictions.

  • Standard
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60384 is applicable to fixed surface mount capacitors for direct current, with
metallized electrodes and polyethylene-terephthalate dielectric for use in electronic equipment.
These capacitors have metallized connecting pads or soldering strips and are intended to be
mounted directly onto printed boards or onto substrates for hybrid circuits. These capacitors
can have "self-healing properties" depending on conditions of use. They are primarily intended
for applications where the AC component is small with respect to the rated voltage.
This part of IEC 60384 specifies preferred ratings and characteristics, and selects from
IEC 60384-1:2021 the appropriate quality assessment procedures, tests and measuring
methods, and gives general performance requirements for this type of capacitor. Test severities
and requirements specified in detail specifications referring to this sectional specification are
of an equal or higher performance level. Lower performance levels are not permitted.
Capacitors for electromagnetic interference suppression are not included, but are covered by
IEC 60384-14.

  • Standard
    40 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60384-19:2022 is applicable to fixed surface mount capacitors for direct current, with metallized electrodes and polyethylene-terephthalate dielectric for use in electronic equipment. These capacitors have metallized connecting pads or soldering strips and are intended to be mounted directly onto printed boards or onto substrates for hybrid circuits. These capacitors can have "self-healing properties" depending on conditions of use. They are primarily intended for applications where the AC component is small with respect to the rated voltage. This part of IEC 60384 specifies preferred ratings and characteristics, and selects from IEC 60384‑1:2021 the appropriate quality assessment procedures, tests and measuring methods, and gives general performance requirements for this type of capacitor. Test severities and requirements specified in detail specifications referring to this sectional specification are of an equal or higher performance level. Lower performance levels are not permitted. Capacitors for electromagnetic interference suppression are not included, but are covered by IEC 60384‑14. This edition includes the following significant technical changes with respect to the previous edition:  revision of all parts of the document based on the ISO/IEC Directives, Part 2:2021, and harmonization with other similar kinds of documents; the document structure has been organized to follow new sectional specification structure decided in TC 40; revised tables and Clause 5 to prevent duplications and contradictions; in Clause 5.2 (Mounting), 5.2.1, 5.2.2 and 5.2.3 have been added; in Clause 5.5 (Shear test), 5.5.1 and 5.5.2 have been added; in Clause 5.14 (Component solvent resistance), 5.14.1 and 5.14.2 have been added. In Table 8 and Table A.2, test 5.14 has been moved before 5.7.5 Final inspections in Group 1A and in Subgroup C1; in Clause 5.15 (Solvent resistance of marking), 5.15.1 and 5.15.2 have been added; tangent of loss angle measurement has been added to resistance to soldering heat test; lot-by-lot and periodical inspection tables including requirements have been moved to Annex A; revised Inspection Level (IL) of A1 subgroup.

  • Standard
    40 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60384-19:2022 is applicable to fixed surface mount capacitors for direct current, with metallized electrodes and polyethylene-terephthalate dielectric for use in electronic equipment. These capacitors have metallized connecting pads or soldering strips and are intended to be mounted directly onto printed boards or onto substrates for hybrid circuits. These capacitors can have "self-healing properties" depending on conditions of use. They are primarily intended for applications where the AC component is small with respect to the rated voltage.
This part of IEC 60384 specifies preferred ratings and characteristics, and selects from IEC 60384‑1:2021 the appropriate quality assessment procedures, tests and measuring methods, and gives general performance requirements for this type of capacitor. Test severities and requirements specified in detail specifications referring to this sectional specification are of an equal or higher performance level. Lower performance levels are not permitted.
Capacitors for electromagnetic interference suppression are not included, but are covered by IEC 60384‑14.
This edition includes the following significant technical changes with respect to the previous edition:  
revision of all parts of the document based on the ISO/IEC Directives, Part 2:2021, and harmonization with other similar kinds of documents;
the document structure has been organized to follow new sectional specification structure decided in TC 40;
revised tables and Clause 5 to prevent duplications and contradictions;
in Clause 5.2 (Mounting), 5.2.1, 5.2.2 and 5.2.3 have been added;
in Clause 5.5 (Shear test), 5.5.1 and 5.5.2 have been added;
in Clause 5.14 (Component solvent resistance), 5.14.1 and 5.14.2 have been added. In Table 8 and Table A.2, test 5.14 has been moved before 5.7.5 Final inspections in Group 1A and in Subgroup C1;
in Clause 5.15 (Solvent resistance of marking), 5.15.1 and 5.15.2 have been added;
tangent of loss angle measurement has been added to resistance to soldering heat test;
lot-by-lot and periodical inspection tables including requirements have been moved to Annex A;
revised Inspection Level (IL) of A1 subgroup.

  • Standard
    76 pages
    English and French language
    sale 15% off

IEC 60384-17:2019 is available as IEC 60384-17:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60384-17:2019 applies to fixed capacitors with metallized electrodes and polypropylene dielectric for use in electronic equipment. Capacitors that have mixed film and metallized electrodes are also within the scope of this standard. These capacitors may have "self-healing" properties depending on conditions of use. Capacitors covered by this specification are mainly intended for use with alternating voltage and/or for pulse applications. The maximum reactive power applicable is 10 000 var and the maximum peak voltage is 3 000 V. This edition includes the following significant technical changes with respect to the previous edition: a) all parts of the document have been revised based on the ISO/IEC Directives, Part 2:2016 (seventh edition) and harmonization between other similar kinds of documents; b) tables and Clause 4 have been revised so as to prevent duplications and contradictions; c) new damp heat steady-state robustness classes with test conditions have been added in text, in Clause 4 and in Annex A.

  • Standard
    47 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60384 applies to fixed capacitors for direct current, with metallized electrodes
and polyethylene-terephthalate dielectric for use in electronic equipment.
These capacitors have a possibility of "self-healing properties" depending on conditions of use.
They are primarily intended for applications where the AC component is small with respect to
the rated voltage. Two performance grades of capacitors are covered: grade 1 for long-life
application and grade 2 for general application.
Capacitors for electromagnetic interference suppression and surface mount fixed metallized
polyethylene-terephthalate film dielectric DC capacitors are not included, but are covered by
IEC 60384-14 and IEC 60384-19, respectively.
The object of this document is to prescribe preferred ratings and characteristics and to select
from IEC 60384-1 the appropriate quality assessment procedures, tests and measuring
methods, and to give general performance requirements for this type of capacitor. Test
severities and requirements prescribed in detail specifications referring to this sectional
specification are of equal or higher performance level, because lower performance levels are
not permitted.

  • Standard
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60384 applies to fixed capacitors for direct current, with metallized electrodes and polyethylene-terephthalate dielectric for use in electronic equipment. These capacitors have a possibility of "self-healing properties" depending on conditions of use. They are primarily intended for applications where the AC component is small with respect to the rated voltage. Two performance grades of capacitors are covered: grade 1 for long-life application and grade 2 for general application. Capacitors for electromagnetic interference suppression and surface mount fixed metallized polyethylene-terephthalate film dielectric DC capacitors are not included, but are covered by IEC 60384-14 and IEC 60384-19, respectively. The object of this document is to prescribe preferred ratings and characteristics and to select from IEC 60384-1 the appropriate quality assessment procedures, tests and measuring methods, and to give general performance requirements for this type of capacitor. Test severities and requirements prescribed in detail specifications referring to this sectional specification are of equal or higher performance level, because lower performance levels are not permitted.

  • Standard
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60384-2:2021 applies to fixed capacitors for direct current, with metallized electrodes and polyethylene-terephthalate dielectric for use in electronic equipment.
These capacitors have a possibility of "self-healing properties" depending on conditions of use. They are primarily intended for applications where the AC component is small with respect to the rated voltage. Two performance grades of capacitors are covered: grade 1 for long-life application and grade 2 for general application.
Capacitors for electromagnetic interference suppression and surface mount fixed metallized polyethylene-terephthalate film dielectric DC capacitors are not included, but are covered by IEC 60384-14 and IEC 60384-19, respectively.
The object of this document is to prescribe preferred ratings and characteristics and to select from IEC 60384-1 the appropriate quality assessment procedures, tests and measuring methods, and to give general performance requirements for this type of capacitor. Test severities and requirements prescribed in detail specifications referring to this sectional specification are of equal or higher performance level, because lower performance levels are not permitted.
This edition includes the following significant technical changes with respect to the previous edition:
a) revision of all parts of the document based on the ISO/IEC Directives, Part 2:2018 and harmonization with other similar kinds of documents;
b) the document structure has been organized to follow the new sectional specification structure decided by TC 40;
c) revision of tables and Clause 5 so as to prevent duplications and contradictions.

  • Standard
    32 pages
    English language
    sale 15% off
  • Standard
    64 pages
    English and French language
    sale 15% off

IEC 60384-13:2020 specifies preferred ratings and characteristics, selects from IEC 60384-1:2016 the appropriate quality assessment procedures, tests and measuring methods, and gives general performance requirements for this type of capacitor. Test severities and requirements specified in detail specifications referring to this sectional specification are of an equal or higher performance level. Lower performance levels are not permitted. This part of IEC 60384 applies to fixed direct current capacitors, using as dielectric a polypropylene film with electrodes of thin metal foils. The capacitors covered by this document are intended for use in electronic equipment. Capacitors for electromagnetic interference suppression are not included, but are covered by IEC 60384-14. This edition includes the following significant technical changes with respect to the previous edition: a) revision of all parts of the document based on the ISO/IEC Directives, Part 2:2018, and harmonization with other similar kinds of documents; b) the document structure has been organized to follow new sectional specification structure decided in TC 40; c) revised tables and Clause 5 so as to prevent duplications and contradictions.

  • Standard
    36 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60384-13:2020 specifies preferred ratings and characteristics, selects from IEC 60384-1:2016 the appropriate quality assessment procedures, tests and measuring methods, and gives general performance requirements for this type of capacitor. Test severities and requirements specified in detail specifications referring to this sectional specification are of an equal or higher performance level. Lower performance levels are not permitted.
This part of IEC 60384 applies to fixed direct current capacitors, using as dielectric a polypropylene film with electrodes of thin metal foils. The capacitors covered by this document are intended for use in electronic equipment.
Capacitors for electromagnetic interference suppression are not included, but are covered by IEC 60384-14.
This edition includes the following significant technical changes with respect to the previous edition:
a) revision of all parts of the document based on the ISO/IEC Directives, Part 2:2018, and harmonization with other similar kinds of documents;
b) the document structure has been organized to follow new sectional specification structure decided in TC 40;
c) revised tables and Clause 5 so as to prevent duplications and contradictions.

  • Standard
    66 pages
    English and French language
    sale 15% off

This Standard applies to fixed capacitors with metallized electrodes and polypropylene dielectric for use in electronic equipment. These capacitors can have "self-healing properties" depending on conditions of use. They are mainly intended for use with direct voltage. The maximum power to be applied is 500 var at 50 Hz and the maximum peak voltage is 2 500 V. The following two grades are covered; a) Grade 1: for long-life application; b) Grade 2: for general application. Capacitors for alternating voltage and pulse applications are not included, but are covered by IEC 60384-17. Capacitors for electromagnetic interference suppression are not included, but are covered by IEC 60384-14. Capacitors for electrical shock hazard protection (covered by IEC 60065) and fluorescent lamp and motor capacitors are also excluded.

  • Standard
    40 pages
    English language
    sale 10% off
    e-Library read for
    1 day

EN-IEC 60384-11 is applicable to fixed direct current capacitors, for rated voltages not exceeding 6 300 V, using as dielectric a polyethylene-terephthalate film and electrodes of thin metal foils. For capacitors with rated voltages exceeding 1 000 V, additional tests and requirements may be specified in the detail specification. The capacitors covered by this document are intended for use in electronic equipment. Capacitors for electromagnetic interference suppression are not included, but are covered by IEC 60384-14. The object of this document is to prescribe preferred ratings and characteristics and to select from IEC 60384-1:2016 the appropriate quality assessment procedures, tests and measuring methods and to give general performance requirements for this type of capacitor. Test severities and requirements prescribed in detail specifications referring to this sectional specification are of an equal or higher performance level. Lower performance levels are not permitted.

  • Standard
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60384-16:2019 applies to fixed capacitors with metallized electrodes and poly­propylene dielectric for use in electronic equipment. These capacitors can have "self-healing properties" depending on conditions of use. They are mainly intended for use with direct voltage.
Capacitors for alternating voltage and pulse applications are not included, but are covered by IEC 60384-17. Capacitors for electromagnetic interference suppression are not included, but are covered by IEC 60384-14. Capacitors for electrical shock hazard protection (covered by IEC 60065) and fluorescent lamp and motor capacitors are also excluded.
The contents of the corrigendum of December 2020 have been included in this copy.

  • Standard
    73 pages
    English and French language
    sale 15% off

IEC 60384-11:2019 is applicable to fixed direct current capacitors, for rated voltages not exceeding 6 300 V, using as dielectric a polyethylene-terephthalate film and electrodes of thin metal foils. For capacitors with rated voltages exceeding 1 000 V, additional tests and requirements may be specified in the detail specification. The capacitors covered by this document are intended for use in electronic equipment. Capacitors for electromagnetic interference suppression are not included, but are covered by IEC 60384‑14. The object of this document is to prescribe preferred ratings and characteristics and to select from IEC 60384-1:2016 the appropriate quality assessment procedures, tests and measuring methods and to give general performance requirements for this type of capacitor. Test severities and requirements prescribed in detail specifications referring to this sectional specification are of an equal or higher performance level. Lower performance levels are not permitted.
This edition includes the following significant technical changes with respect to the previous edition:
a) revision of all parts of the document based on the ISO/IEC Directives, Part 2:2018, and harmonization with other similar kinds of documents;
b) the document structure has been organized to follow new sectional specification structure decided in TC 40;
c) revised tables and Clause 5 so as to prevent duplications and contradictions.
The contents of the corrigendum of April 2020 have been included in this copy.

  • Standard
    65 pages
    English and French language
    sale 15% off

IEC 60384-3:2006 applies to surface mount tantalum solid electrolyte capacitors. These capacitors are primarily intended to be mounted directly onto substrates for hybrid circuits or onto printed boards. The following two styles are considered: Style 1 - protected capacitors; Style 2 - unprotected capacitors. This third edition cancels and replaces the second edition published in 1989 and constitutes a minor revision related to tables, figures and references This bilingual version, published in 2008-06, corresponds to the English version.

  • Standard
    33 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60384-17:2019 is available as IEC 60384-17:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60384-17:2019 applies to fixed capacitors with metallized electrodes and polypropylene dielectric for use in electronic equipment. Capacitors that have mixed film and metallized electrodes are also within the scope of this standard. These capacitors may have "self-healing" properties depending on conditions of use. Capacitors covered by this specification are mainly intended for use with alternating voltage and/or for pulse applications. The maximum reactive power applicable is 10 000 var and the maximum peak voltage is 3 000 V. This edition includes the following significant technical changes with respect to the previous edition:
a) all parts of the document have been revised based on the ISO/IEC Directives, Part 2:2016 (seventh edition) and harmonization between other similar kinds of documents;
b) tables and Clause 4 have been revised so as to prevent duplications and contradictions;
c) new damp heat steady-state robustness classes with test conditions have been added in text, in Clause 4 and in Annex A.
The contents of the corrigendum of December 2020 have been included in this copy.

  • Standard
    90 pages
    English and French language
    sale 15% off

IEC 60384-19:2015 is applicable to fixed surface mount capacitors for direct current, with metallized electrodes and polyethylene-terephthalate dielectric for use in electronic equipment. These capacitors have metallized connecting pads or soldering strips and are intended to be mounted directly onto substrates for hybrid circuits or onto printed boards. These capacitors may have "self-healing properties" depending on conditions of use. They are primarily intended for applications where the a.c. component is small with respect to the rated voltage. Capacitors for electromagnetic interference suppression are not included, but are covered by IEC 60384 14. This edition includes the following significant technical changes with respect to the previous edition: a) Revised all parts of the document based on the IEC Directives Part 2:2011 (sixth edition) to the extent practicable, and harmonization between other similar kind of documents. b) Revised tables and Clause 4 so as to prevent duplications and contradictions.

  • Standard
    33 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Ta del IEC 60252 velja za zaganjalne kondenzatorje, namenjene povezavi z navitji asinhronih motorjev, napajanih iz enofaznega sistema, ki imajo frekvenco javnega omrežja. Ta standard zajema zaganjalne kondenzatorje motorjev, ki so ali niso impregnirani in ki imajo dielektrik iz papirja ali plastičnega filma ali kombinacije obeh, ter elektrolitske zaganjalne kondenzatorje, ki nimajo trdnih elektrolitov, z ocenjeno napetostjo do in vključno 660 V.

  • Amendment
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60252 applies to motor capacitors intended for connection to windings of asynchronous motors supplied from a single-phase system having a frequency up to and including 100 Hz, and to capacitors to be connected to three-phase asynchronous motors so that these motors may be supplied from a single-phase system. This standard covers impregnated or unimpregnated capacitors having a dielectric of paper, plastic film, or a combination of both, either metallized or with metal-foil electrodes, with rated voltages up to and including 660 V. Motor start capacitors are covered by IEC 60252-2. The object of this standard is a) to formulate uniform rules regarding performance, testing and rating; b) to formulate specific safety rules; c) to provide a guidance for installation and operation.

  • Amendment
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60384-3:2016 applies to fixed tantalum electrolytic surface mount capacitors with solid (MnO2) electrolyte primarily intended for d.c. applications for use in electronic equipment. The following two styles are considered:
- Style 1 - Capacitors protected with external materials;
- Style 2 - Capacitors unprotected with external materials. This edition includes the following significant technical changes with respect to the previous edition:
a) Revision of the structure in accordance with ISO/IEC Directives, Part 2:2011 (sixth edition) to the extent practicable, and harmonization between other similar kinds of documents.
b) In addition, Clause 4 and all the tables have been reviewed in order to prevent duplications and contradictions.

  • Standard
    60 pages
    English and French language
    sale 15% off

IEC 60384-19:2015 is applicable to fixed surface mount capacitors for direct current, with metallized electrodes and polyethylene-terephthalate dielectric for use in electronic equipment. These capacitors have metallized connecting pads or soldering strips and are intended to be mounted directly onto substrates for hybrid circuits or onto printed boards. These capacitors may have "self-healing properties" depending on conditions of use. They are primarily intended for applications where the a.c. component is small with respect to the rated voltage. Capacitors for electromagnetic interference suppression are not included, but are covered by IEC 60384 14. This edition includes the following significant technical changes with respect to the previous edition:
a) Revised all parts of the document based on the IEC Directives Part 2:2011 (sixth edition) to the extent practicable, and harmonization between other similar kind of documents.
b) Revised tables and Clause 4 so as to prevent duplications and contradictions.

  • Standard
    61 pages
    English and French language
    sale 15% off

IEC 60384-2:2011 applies to fixed capacitors for direct current, with metallized electrodes and polyethylene-terephthalate dielectric for use in electronic equipment. These capacitors may have 'self-healing properties' depending on conditions of use. They are primarily intended for applications where the a.c. component is small with respect to the rated voltage. Two performance grades of capacitors are covered, Grade 1 for long-life application and Grade 2 for general application. Capacitors for electromagnetic interference suppression and surface mount fixed metallized polyethylene-terephthalate film dielectric d.c. capacitors are not included, but are covered by IEC 60384-14 and IEC 60384-19 respectively. This fourth edition cancels and replaces the third edition published in 2005 and contains the following significant technical changes with respect to the previous edition.
- Table 1, Sampling plan together with numbers of permissible non-conformance for qualification approval test, has been adjusted.
- Table 3, Lot-by-lot inspection, has been changed, highlighting assessment level EZ only.
- Table 4, Periodic inspection, has been changed, highlighting assessment level EZ only.
- The preferred values of rated voltages have been updated in conformance with the basic series of preferred values R5 and R10 given in ISO 3.

  • Standard
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60384-13:2011 applies to fixed direct current capacitors, using as dielectric a polypropylene film with electrodes of thin metal foils. The capacitors covered by this standard are intended for use in electronic equipment. Capacitors for electromagnetic interference suppression are not included, but are covered by IEC 60384-14. This fourth edition cancels and replaces the third edition published in 2006 and contains the following significant technical changes with respect to the previous edition. - Table 3, Sampling plan together with numbers of permissible non-conformance for qualification approval test, has been adjusted. - Table 5, Lot-by-lot inspection, has been changed, highlighting assessment level EZ only. - Table 6, Periodic inspection, has been changed, highlighting assessment level EZ only.

  • Standard
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60252-2:2010 applies to motor start capacitors intended for connection to windings of asynchronous motors supplied from a single-phase system having the frequency of the mains. Covers impregnated or unimpregnated metallized motor start capacitors having a dielectric of paper or plastic film, or a combination of both and electrolytic motor start capacitors with non-solid electrolyte, with rated voltages up to and including 660 V. The main changes with respect to the previous edition are: - definition of segmented film capacitors; - clearer definition of the purpose of d.c. conditioning in destruction test.

  • Standard
    46 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60252-1:2010 applies to motor capacitors intended for connection to windings of asynchronous motors supplied from a single-phase system having a frequency up to and including 100 Hz, and to capacitors to be connected to three-phase asynchronous motors so that these motors may be supplied from a single-phase system. This standard covers impregnated or unimpregnated capacitors having a dielectric of paper, plastic film, or a combination of both, either metallized or with metal-foil electrodes, with rated voltages up to and including 660 V. This edition includes the following significant technical changes with respect to the previous edition: - the definition of 'segmented capacitors' has been added in 3.6; - the definition of 'classes of operation' has been clarified, with the addition of the concept of 'probable life' with reference to statistics, in 3.9; - the following wording 'Operation above the rated voltage will reduce the life expectancy of the capacitor' has been introduced in 6.1. - some clarifications have been added to Clause 8, Marking, mainly for small capacitors.

  • Standard
    33 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This International Standard defines the conditions of utilization of the recycling symbol of the International Organization for Standardization (ISO) associated with the chemical symbols indicating the electrochemical system of the battery. This standard applies to lead-acid batteries (Pb) and nicke-cadmium batteries (Ni-Cd).

  • Standard
    16 pages
    English and French language
    sale 15% off

This is an informative document covering the broadest aspects of automatic monitor systems as they apply to traction battery applications. The subject of the guide covers those monitor characteristics and features which need to be controlled, though not necessarily currently available. In addition it accommodates those characteristics which are measurable and provides interpretations of accuracy and reliability of the information generated.[
]This publication has the status of a Technical Report - type 3.

  • Standard
    17 pages
    English and French language
    sale 15% off

IEC 60384-2:2011 applies to fixed capacitors for direct current, with metallized electrodes and polyethylene-terephthalate dielectric for use in electronic equipment. These capacitors may have "self-healing properties" depending on conditions of use. They are primarily intended for applications where the a.c. component is small with respect to the rated voltage. Two performance grades of capacitors are covered, Grade 1 for long-life application and Grade 2 for general application. Capacitors for electromagnetic interference suppression and surface mount fixed metallized polyethylene-terephthalate film dielectric d.c. capacitors are not included, but are covered by IEC 60384-14 and IEC 60384-19 respectively. This fourth edition cancels and replaces the third edition published in 2005 and contains the following significant technical changes with respect to the previous edition.
- Table 1, Sampling plan together with numbers of permissible non-conformance for qualification approval test, has been adjusted.
- Table 3, Lot-by-lot inspection, has been changed, highlighting assessment level EZ only.
- Table 4, Periodic inspection, has been changed, highlighting assessment level EZ only.
- The preferred values of rated voltages have been updated in conformance with the basic series of preferred values R5 and R10 given in ISO 3.

  • Standard
    56 pages
    English and French language
    sale 15% off

IEC 60384-13:2011 applies to fixed direct current capacitors, using as dielectric a polypropylene film with electrodes of thin metal foils. The capacitors covered by this standard are intended for use in electronic equipment. Capacitors for electromagnetic interference suppression are not included, but are covered by IEC 60384-14. This fourth edition cancels and replaces the third edition published in 2006 and contains the following significant technical changes with respect to the previous edition.
- Table 3, Sampling plan together with numbers of permissible non-conformance for qualification approval test, has been adjusted.
- Table 5, Lot-by-lot inspection, has been changed, highlighting assessment level EZ only.
- Table 6, Periodic inspection, has been changed, highlighting assessment level EZ only.

  • Standard
    53 pages
    English and French language
    sale 15% off

It is a supplementary document to the sectional specification and contains requirements for style and layout and minimum content of detail specifications. Detail specifications not complying with these requirements may not be considered as being in accordance with IEC specifications nor shall they so be described. In the preparation of detail specifications, the content of 1.4 of the sectional specification shall be taken into account. It constitutes a minor revision related to tables, figures and references.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60252-2:2010 applies to motor start capacitors intended for connection to windings of asynchronous motors supplied from a single-phase system having the frequency of the mains. Covers impregnated or unimpregnated metallized motor start capacitors having a dielectric of paper or plastic film, or a combination of both and electrolytic motor start capacitors with non-solid electrolyte, with rated voltages up to and including 660 V. The main changes with respect to the previous edition are:
- definition of segmented film capacitors;
- clearer definition of the purpose of d.c. conditioning in destruction test.

  • Standard
    87 pages
    English and French language
    sale 15% off

IEC 60252-1:2010 applies to motor capacitors intended for connection to windings of asynchronous motors supplied from a single-phase system having a frequency up to and including 100 Hz, and to capacitors to be connected to three-phase asynchronous motors so that these motors may be supplied from a single-phase system. This standard covers impregnated or unimpregnated capacitors having a dielectric of paper, plastic film, or a combination of both, either metallized or with metal-foil electrodes, with rated voltages up to and including 660 V. This edition includes the following significant technical changes with respect to the previous edition:
- the definition of "segmented capacitors" has been added in 3.6;
- the definition of "classes of operation" has been clarified, with the addition of the concept of "probable life" with reference to statistics, in 3.9;
- the following wording "Operation above the rated voltage will reduce the life expectancy of the capacitor" has been introduced in 6.1.
- some clarifications have been added to Clause 8, Marking, mainly for small capacitors.

  • Standard
    61 pages
    English and French language
    sale 15% off

IEC 60384-3-1:2006 is a bilingual version and corresponds to the English version. It is a supplementary document to the sectional specification and contains requirements for style, layout and minimum content of detail specifications. Detail specifications not complying with these requirements may not be considered as being in accordance with IEC specifications nor shall they so be described. It cancels and replaces the first edition published in 1989 and constitutes a minor revision related to tables, figures and references.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60384-13-1:2006(E) is a supplementary document to the sectional specification and contains requirements for style and layout and minimum content of detail specifications. Detail specifications not complying with these requirements may not be considered as being in accordance with IEC specifications nor shall they so be described. The contents of the corrigendum of March 2009 have been included in this copy.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

blank detail specification is a supplementary document to the sectional specification and contains requirements for style and layout and minimum content of details specifications. Detail specifications not complying with these requirements may not be considered as being in accordance with IEC specifications nor shall they be so described.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

blank detail specification is a supplementary document to the sectional specification and contains requirements for style and layout and minimum content of details specifications. Detail specifications not complying with these requirements may not be considered as being in accordance with IEC specifications nor shall they be so described.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

blank detail specification is a supplementary document to the sectional specification and contains requirements for style and layout and minimum content of details specifications. Detail specifications not complying with these requirements may not be considered as being in accordance with IEC specifications nor shall they be so described.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

It is a supplementary document to the sectional specification and contains requirements for style and layout and minimum content of detail specifications. Detail specifications not complying with these requirements may not be considered as being in accordance with IEC specifications nor shall they so be described. In the preparation of detail specifications, the content of 1.4 of the sectional specification shall be taken into account. It constitutes a minor revision related to tables, figures and references.

  • Standard
    13 pages
    English language
    sale 15% off

IEC 60384-3-1:2006 is a bilingual version and corresponds to the English version. It is a supplementary document to the sectional specification and contains requirements for style, layout and minimum content of detail specifications. Detail specifications not complying with these requirements may not be considered as being in accordance with IEC specifications nor shall they so be described. It cancels and replaces the first edition published in 1989 and constitutes a minor revision related to tables, figures and references.

  • Standard
    29 pages
    English and French language
    sale 15% off

IEC 60384-13-1:2006(E) is a supplementary document to the sectional specification and contains requirements for style and layout and minimum content of detail specifications. Detail specifications not complying with these requirements may not be considered as being in accordance with IEC specifications nor shall they so be described. The contents of the corrigendum of March 2009 have been included in this copy.

  • Standard
    13 pages
    English language
    sale 15% off

blank detail specification is a supplementary document to the sectional specification and contains requirements for style and layout and minimum content of details specifications. Detail specifications not complying with these requirements may not be considered as being in accordance with IEC specifications nor shall they be so described.

  • Standard
    13 pages
    English language
    sale 15% off

blank detail specification is a supplementary document to the sectional specification and contains requirements for style and layout and minimum content of details specifications. Detail specifications not complying with these requirements may not be considered as being in accordance with IEC specifications nor shall they be so described.

  • Standard
    13 pages
    English language
    sale 15% off

blank detail specification is a supplementary document to the sectional specification and contains requirements for style and layout and minimum content of details specifications. Detail specifications not complying with these requirements may not be considered as being in accordance with IEC specifications nor shall they be so described.

  • Standard
    16 pages
    English language
    sale 15% off