IEC 60352-7:2020 is available as IEC 60352-7:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60352-7:2020 is applicable to spring clamp connections made with stripped wire without further preparation: - solid conductors of 0,32 mm to 3,7 mm nominal diameter (0,08 mm2 to 10 mm2 cross‑section), or - stranded conductors of 0,08 mm2 to 10 mm2 cross-section, or - flexible conductors of 0,08 m...view more

    • sale 10% off
    • Standard
      34 pages
      English language
    • e-Library read for
      1 day

IEC 60352-7:2020 is available as IEC 60352-7:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60352-7:2020 is applicable to spring clamp connections made with stripped wire without further preparation:
- solid conductors of 0,32 mm to 3,7 mm nominal diameter (0,08 mm2 to 10 mm2 cross‑section), or
- stranded conductors of 0,08 mm2 to 10 mm2 cross-section, or
- flexible conductors of...
view more

    • sale 15% off
    • Standard
      30 pages
      English language

This part of IEC 60603-7 covers 8-way, unshielded, free and fixed connectors and is intended
to specify the common dimensions (interface dimensions), mechanical, electrical and
environmental characteristics and tests for the family of IEC 60603-7-x connectors.
These connectors are intermateable (according to IEC 61076-1 level 2) and interoperable with
other IEC 60603-7 series connectors.

    • sale 10% off
    • Standard
      58 pages
      English language
    • e-Library read for
      1 day

This part of IEC 61076 describes circular connectors with M8 screw locking typically used for
data and power transmissions in industrial applications. These connectors consist of fixed and
free connectors that are either rewireable or non-rewireable. Data transmission performance
is for Category 5 up to 100 MHz.
Two coded versions, identified as D-coded and P-coded, are provided that differ by their pin
size and optionally by number of poles, hence by the function provided for field applica...
view more

    • sale 10% off
    • Standard
      51 pages
      English language
    • e-Library read for
      1 day

IEC 61076-2-114:2020 describes circular connectors with M8 screw locking typically used for data and power transmissions in industrial applications. These connectors consist of fixed and free connectors that are either rewireable or non-rewireable. Data transmission performance is for Category 5 up to 100 MHz.
Two coded versions, identified as D-coded and P-coded, are provided that differ by their pin size and optionally by number of poles, hence by the function provided for field applications....
view more

    • sale 15% off
    • Standard
      93 pages
      English and French language

This part of IEC 61076 specifies circular connectors with an inner push‑pull locking
mechanism of a size derived from and thus being compatible with M12 screw‑locking
connectors and with mating interfaces according to IEC 61076‑2‑101, IEC 61076‑2‑109,
IEC 61076‑2‑111 and IEC 61076‑2‑113.
A female fixed connector with inner push-pull locking according to this document is
intermateable with a correspondingly coded male free connector with M12 screw-locking
according to IEC 61076-2-101, IEC 6...
view more

    • sale 10% off
    • Standard
      65 pages
      English language
    • e-Library read for
      1 day

This part of IEC 60352 is applicable to solderless press-in connections for use in electrical
and electronic equipment and components.
The press-in connection consists of a termination having a suitable press-in zone which is
inserted into a hole of a board.
Information on materials and data from industrial experience is included in addition to the test
procedures to provide electrically stable connections under specified environmental conditions.
The object of this document is to determin...
view more

    • sale 10% off
    • Standard
      38 pages
      English language
    • e-Library read for
      1 day

This part of IEC 60512, when required by the detail product specification, is used for testing
connectors or solderless connections within the scope of technical committee 48. It may also be
used for similar devices when specified in a detail product specification.
The object of this document is to detail a standard method for subjecting solderless
connections to thermal stress conditioning by cyclic current loading.

    • sale 10% off
    • Standard
      14 pages
      English language
    • e-Library read for
      1 day

IEC 61076-2-012:2020 specifies circular connectors with an inner push‑pull locking mechanism of a size derived from and thus being compatible with M12 screw‑locking connectors and with mating interfaces according to IEC 61076‑2‑101, IEC 61076‑2‑109, IEC 61076‑2‑111 and IEC 61076‑2‑113.
A female fixed connector with inner push-pull locking according to this document is intermateable with a correspondingly coded male free connector with M12 screw-locking according to IEC 61076-2-101, IEC 61076-2-...
view more

    • sale 15% off
    • Standard
      121 pages
      English and French language

IEC 60352-5:2020 is applicable to solderless press-in connections for use in electrical and electronic equipment and components.
The press-in connection consists of a termination having a suitable press-in zone which is inserted into a hole of a board.
Information on materials and data from industrial experience is included in addition to the test procedures to provide electrically stable connections under specified environmental conditions.
The object of this document is to determine the sui...
view more

    • sale 15% off
    • Standard
      69 pages
      English and French language
    • sale 15% off
    • Standard
      34 pages
      English language

IEC PAS 61076-2-010:2020 specifies circular connectors with a push-pull locking mechanism of a size derived from and thus being compatible with M12 screw-locking connectors (free connectors with screw-locking according to IEC 61076-2-101, IEC 61076-2-109, IEC 61076­2­111 or IEC 61076-2-113 are compatible to push-pull fixed interfaces according to this document) and with mating interfaces according to IEC 61076-2-101, IEC 61076-2-109, IEC 61076-2-111 or IEC 61076-2-113.

    • sale 15% off
    • Technical specification
      41 pages
      English language

This part of IEC 61076 describes 2-pole or 3-pole power plus 2-pole signal shielded and
sealed connectors with plastic housing (hereinafter referred to as a connector) for electrical
and electronic equipment, including overall dimensions, interface dimensions, technical
characteristics, performance requirements and test methods.
This document is applicable to electrical connectors with sealing and shielding requirements
meeting this document, with a rated voltage up to and including 750 V a...
view more

    • sale 10% off
    • Standard
      44 pages
      English language
    • e-Library read for
      1 day

This part of IEC 63171 covers two-way, shielded or unshielded, free and fixed connectors for
data transmission with frequencies up to 600 MHz and with current carrying capacity up
to 2,0 A at 60 °C. It is intended to specify the common dimensions, mechanical, electrical,
signal integrity, environmental characteristics, reliability specifications and corresponding
tests for these connectors.

    • sale 10% off
    • Standard
      35 pages
      English language
    • e-Library read for
      1 day

This part of IEC 61076 describes 2-pole or 3-pole power plus 2-pole signal shielded and
sealed connectors with plastic housing (hereinafter referred to as a connector) for electrical
and electronic equipment, including overall dimensions, interface dimensions, technical
characteristics, performance requirements and test methods.
This document is applicable to electrical connectors with sealing and shielding requirements
meeting this document, with a rated voltage up to and including 750 V a...
view more

    • sale 10% off
    • Standard
      45 pages
      English language
    • e-Library read for
      1 day

This part of IEC 61076 describes 2-pole or 3-pole power plus 2-pole signal shielded and
sealed connectors with plastic housing (hereinafter referred to as a connector) for electrical
and electronic equipment, including overall dimensions, interface dimensions, technical
characteristics, performance requirements and test methods.
This document is applicable to electrical connectors with sealing and shielding requirements
meeting this document, with a rated voltage up to and including 750 V a...
view more

    • sale 10% off
    • Standard
      45 pages
      English language
    • e-Library read for
      1 day

IEC 63171-6:2020, covers 2-way and 4-way (data/power) shielded free and fixed connectors for data transmission with frequencies up to 600 MHz and specifies the common dimensions, mechanical, electrical and transmission characteristics and environmental requirements as well as test specifications respectively. This document specifies several properties overlapping with specifications in the IEC 63171 series which have been drafted later. In case of conflict the specifications within this document...view more

    • sale 10% off
    • Standard
      54 pages
      English language
    • e-Library read for
      1 day

NEXT ACTION: PUBLICATION EXPECTED BY 2020-05-15

    • sale 10% off
    • Amendment
      12 pages
      English language
    • e-Library read for
      1 day

IEC 61076-8-102:2020 describes 2-pole or 3-pole power plus 2-pole signal shielded and sealed connectors with plastic housing (hereinafter referred to as a connector) for electrical and electronic equipment, including overall dimensions, interface dimensions, technical characteristics, performance requirements and test methods.
This document is applicable to electrical connectors with sealing and shielding requirements meeting this document, with a rated voltage up to and including 750 V a.c. or...
view more

    • sale 15% off
    • Standard
      80 pages
      English and French language

IEC 63171-1:2020 covers two-way, shielded or unshielded, free and fixed connectors for data transmission with frequencies up to 600 MHz and with current carrying capacity up to 2,0 A at 60 °C. It is intended to specify the common dimensions, mechanical, electrical, signal integrity, environmental characteristics, reliability specifications and corresponding tests for these connectors.

    • sale 15% off
    • Standard
      63 pages
      English and French language

IEC 61076-8-101:2020 describes 2-pole or 3-pole power plus 2-pole signal shielded and sealed connectors with plastic housing (hereinafter referred to as a connector) for electrical and electronic equipment, including overall dimensions, interface dimensions, technical characteristics, performance requirements and test methods.
This document is applicable to electrical connectors with sealing and shielding requirements meeting this document, with a rated voltage up to and including 750 V a.c. or...
view more

    • sale 15% off
    • Standard
      80 pages
      English and French language

IEC 61076-8-100:2020 describes 2-pole or 3-pole power plus 2-pole signal shielded and sealed connectors with plastic housing (hereinafter referred to as a connector) for electrical and electronic equipment, including overall dimensions, interface dimensions, technical characteristics, performance requirements and test methods.
This document is applicable to electrical connectors with sealing and shielding requirements meeting this document, with a rated voltage up to and including 750 V a.c. or...
view more

    • sale 15% off
    • Standard
      80 pages
      English and French language

IEC 63171-6:2020, covers 2-way and 4-way (data/power) shielded free and fixed connectors for data transmission with frequencies up to 600 MHz and specifies the common dimensions, mechanical, electrical and transmission characteristics and environmental requirements as well as test specifications respectively. This document specifies several properties overlapping with specifications in the IEC 63171 series which have been drafted later. In case of conflict the specifications within this document...view more

    • sale 10% off
    • Standard
      54 pages
      English language
    • e-Library read for
      1 day

IEC 63171-6:2020, covers 2-way and 4-way (data/power) shielded free and fixed connectors for data transmission with frequencies up to 600 MHz and specifies the common dimensions, mechanical, electrical and transmission characteristics and environmental requirements as well as test specifications respectively.
This document specifies several properties overlapping with specifications in the IEC 63171 series which have been drafted later. In case of conflict the specifications within this documen...
view more

    • sale 15% off
    • Standard
      98 pages
      English and French language

This document specifies the test methods for signal integrity and transmission performance for connectors specified in respective parts of IEC 60603-7, IEC 61076-1, IEC 61076-2, and IEC 61076-3 standards for connecting hardware applications up to 2 000 MHz. It is also suitable for testing lower frequency connectors, however, the test methodology specified in the detail specification for any given connector remains the reference conformance test for that connector. The above list of connector ser...view more

    • sale 10% off
    • Standard
      50 pages
      English language
    • e-Library read for
      1 day

IEC 60512-28-100:2019 is available as IEC 60512-28-100:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60512-28-100:2019 specifies the test methods for signal integrity and transmission performance for connectors specified in respective parts of IEC 60603-7, IEC 61076-1, IEC 61076-2, and IEC 61076-3 standards for connecting hardware applications up to 2 000 MHz. It is also suitable for t...view more

    • sale 10% off
    • Standard
      50 pages
      English language
    • e-Library read for
      1 day

This document specifies the characteristics of dummy receptacles in the family of circular electrical connectors coupled by threaded ring. It applies to the class defined in Table 3. For plugs associated with these dummy receptacles, see EN 2997-008.

    • sale 10% off
    • Standard
      9 pages
      English language
    • e-Library read for
      1 day

EN-IEC 61076-3-123 covers hybrid rectangular connectors with a 3 poles 16 A electric portion for power supply and a duplex fibre optic connector type LC portion for data transmission. These connectors consist of fixed and free connectors, either rewirable or non-rewirable (for both portions) and use the rectangular push-pull housing described in IEC 61076-3-117 with IP65/IP67 degree of protection, for harsh applications. The mating dimensions of such housings allow fulfilling the performance cla...view more

    • sale 10% off
    • Standard
      51 pages
      English language
    • e-Library read for
      1 day

This document defines a banding band, style Z, for terminating individual and/or overall cable screens to cable outlets. The bands delivered in flat condition F (see Clause 6) which need to be double wrapped prior to their installation. The bands delivered in condition C (see Clause 6) are factory pre-double wrapped and ready for installation.

    • sale 10% off
    • Standard
      13 pages
      English language
    • e-Library read for
      1 day

This document defines the insertion/extraction tool for removal of modules used in the family of rectangular electrical connectors.

    • sale 10% off
    • Standard
      7 pages
      English language
    • e-Library read for
      1 day

IEC 60512-28-100:2019 is available as IEC 60512-28-100:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60512-28-100:2019 specifies the test methods for signal integrity and transmission performance for connectors specified in respective parts of IEC 60603-7, IEC 61076-1, IEC 61076-2, and IEC 61076-3 standards for connecting hardware applications up to 2 000 MHz. It is also suitable fo...
view more

    • sale 15% off
    • Standard
      90 pages
      English and French language

IEC 61076-3-123:2019. covers hybrid rectangular connectors with a 3 poles 16 A electric portion for power supply and a duplex fibre optic connector type LC portion for data transmission. These connectors consist of fixed and free connectors, either rewirable or non-rewirable (for both portions) and use the rectangular push-pull housing described in IEC 61076-3-117 with IP65/IP67 degree of protection, for harsh applications. The mating dimensions of such housings allow fulfilling the performance ...view more

    • sale 10% off
    • Standard
      51 pages
      English language
    • e-Library read for
      1 day

IEC 61169-24:2019 is available as IEC 61169-24:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61169-24:2019, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for RF coaxial connectors with screw coupling, typically for use in 75 W cable networks (type F). It describes the interface dimensions with gauging informati...view more

    • sale 10% off
    • Standard
      29 pages
      English language
    • e-Library read for
      1 day

IEC 61076-3-123:2019. covers hybrid rectangular connectors with a 3 poles 16 A electric portion for power supply and a duplex fibre optic connector type LC portion for data transmission.
These connectors consist of fixed and free connectors, either rewirable or non-rewirable (for both portions) and use the rectangular push-pull housing described in IEC 61076-3-117 with IP65/IP67 degree of protection, for harsh applications.
The mating dimensions of such housings allow fulfilling the performanc...
view more

    • sale 15% off
    • Standard
      89 pages
      English and French language

This document specifies the general characteristics, the conditions for qualification, acceptance and quality assurance, as well as the test programs and groups for threaded ring coupling circular connectors, fire resistant, intended for use in a temperature range from − 65 °C to 175 °C continuous or 200 °C continuous according to the classes.

    • sale 10% off
    • Standard
      104 pages
      English language
    • e-Library read for
      1 day

IEC 61169-24:2019 is available as IEC 61169-24:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61169-24:2019, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for RF coaxial connectors with screw coupling, typically for use in 75 W cable networks (type F). It describes the interface dimensions with gauging inform...
view more

    • sale 15% off
    • Standard
      52 pages
      English and French language

This European Standard specifies the characteristics of dummy receptacles in the family of circular,
electrical connectors, with triple start threaded coupling.
It applies to models in Table 3.
For plugs and protective covers, see EN 3645-006, EN 3645-008, EN 3645-011 and EN 3645-012
respectively.
These receptacles are derived from those in specification MIL-DTL-38999/22.

    • sale 10% off
    • Standard
      9 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies the characteristics of round flange hermetic receptacles, mounted by
soldering, in the family of circular electrical connectors with triple start threaded coupling.
It applies to models in Table 3.
The contacts are unremovable and soldered termination.
For plugs and protective covers, see EN 3645-006, EN 3645-008, EN 3645-011, and EN 3645-012
respectively.
These connectors are derived from and interchangeable with model Y in specification
MIL-DTL-38999/25.

    • sale 10% off
    • Standard
      8 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies the characteristics of hermetic receptacles with jam nut mounting in
the family of circular, electrical connectors, with triple start threaded coupling.
It applies to models in Table 3.
For plugs and protective covers, see EN 3645-006, EN 3645-008, EN 3645-011 and EN 3645-012 respectively.
The contacts are unremovable and soldered termination.
These connectors are derived from and interchangeable with model Y in specification MIL-DTL-38999/23.

    • sale 10% off
    • Standard
      10 pages
      English language
    • e-Library read for
      1 day

This part of IEC 60512 is used for testing connectors within the scope of SC 48B that are used
in twisted pair communication cabling with remote power, such as ISO/IEC 11801 Class D (or
better), balanced cabling in support of IEEE Std 802.3bt™, (PoE Plus – Power over Ethernet
Plus).
The object of this document is to detail a test schedule to determine the ability of pairs of
connectors to withstand a sequence of tests with a total of 100 engagements and separations.
The electrical current ...
view more

    • sale 10% off
    • Standard
      16 pages
      English language
    • e-Library read for
      1 day

This part of IEC 61076 covers 10-way, shielded, free and fixed rectangular connectors for data transmission with frequencies up to 500 MHz and specifies the common dimensions, mechanical, electrical and transmission characteristics and environmental requirements as well as test specifications respectively. Connectors covered in this document are provided in three codings that differ only for the position of the polarization key and keyway, in view of their differently intended use:
• Connectors...
view more

    • sale 10% off
    • Standard
      48 pages
      English language
    • e-Library read for
      1 day

This European Standard defines a range of cable outlets, style A, 90°, unsealed with clamp strain relief for use under the following conditions:
Associated electrical connector(s)   :   EN 3660-002
Temperature range,   Class N   :   - 65 °C to 200 °C
   Class W   :   - 65 °C to 175 °C
   Class K   :   -65 °C to 260 °C
   Class A   :   - 65 °C to 260 °C
   Class T   :   - 65 °C to 175 °C
   Class Z   :   - 65 °C to 175 °C

    • sale 10% off
    • Standard
      12 pages
      English language
    • e-Library read for
      1 day

This document defines a range of cable outlets, style A, straight, unsealed with clamp strain relief for use under the following conditions:
Associated electrical connector(s)   :   EN 3660-002
Temperature range,   Class N   :   - 65 °C to 200 °C
Class W   :   - 65 °C to 175 °C
Class K   :   - 65 °C to 260 °C
Class A   :   - 65 °C to 200 °C
Class T   :   - 65 °C to 175 °C (Nickel PTFE plating)
Class Z   :   - 65 °C to 175 °C (Black zinc nickel plating)

    • sale 10% off
    • Standard
      12 pages
      English language
    • e-Library read for
      1 day

This part of IEC 61076 covers 10-way, shielded, free and fixed rectangular connectors for data transmission with frequencies up to 500 MHz and specifies the common dimensions, mechanical, electrical and transmission characteristics and environmental requirements as well as test specifications respectively. Connectors covered in this document are provided in three codings that differ only for the position of the polarization key and keyway, in view of their differently intended use: - Connectors ...view more

    • sale 10% off
    • Standard
      48 pages
      English language
    • e-Library read for
      1 day

This part of IEC 60512 is used for testing connectors within the scope of SC 48B that are used in twisted pair communication cabling with remote power, such as ISO/IEC 11801 Class D (or better), balanced cabling in support of IEEE Std 802.3bt, (PoE Plus - Power over Ethernet Plus). The object of this document is to detail a test schedule to determine the ability of pairs of connectors to withstand a sequence of tests with a total of 100 engagements and separations. The electrical current is pass...view more

    • sale 10% off
    • Standard
      16 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies the characteristics of jam nut mounting receptacles in the family of
circular, electrical connectors, with triple start threaded coupling.
It applies to models in Table 3.
For plugs and protective covers, see EN 3645-006, EN 3645-008, EN 3645-011 and EN 3645-012 respectively.
For sealing plugs and cable outlet accessories associated with this receptacle, see EN 3645-002.
These connectors are derived from and interchangeable with models W, F, J, M, Z, T and K...
view more

    • sale 10% off
    • Standard
      10 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies the characteristics of square flange hermetic receptacles in the family
of circular electrical connectors with triple start threaded coupling.
It applies to models in Table 3.
The contacts are unremovable and soldered termination.
For plugs and protective covers, see EN 3645-008, EN 3645-011, EN 3645-012 and EN 3645-006
respectively.
These connectors are derived from and interchangeable with model Y in specification
MIL-DTL-38999/21.

    • sale 10% off
    • Standard
      8 pages
      English language
    • e-Library read for
      1 day

This part of IEC 60512 defines a standard test method for measuring the shielding
effectiveness SE of a shielded connector, or of a connector not provided with integral shield
once fitted with a shielding accessory and terminated with a screened cable.
The complete assembly has a continuous 360° shielding capability throughout its length.
NOTE 1 Practically, continuous 360° shielding is not always achievable based on the geometry of the connector.
NOTE 2 Shielding” is used in this document ...
view more

    • sale 10% off
    • Standard
      18 pages
      English language
    • e-Library read for
      1 day