The present document specifies technical characteristics and methods of measurements for TV White Space Devices
(TVWSDs) controlled by a TV White Space Database (TVWSDB) and which operate in the TV broadcast band
470 MHz to 694 MHz.
The present document applies to the following radio equipment categories:
1) Primary TV white space device.
2) Secondary TV white space device.
The present document applies to TVWSDs with integral, dedicated or external antennas, where TVWSDs using external
antennas is covered only in the case of fixed use.
NOTE: The relationship between the present document and essential requirements of article 3.2 of Directive
2014/53/EU [i.3] is given in annex A.

  • Standard
    82 pages
    English language
    sale 15% off
  • Standard
    82 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    82 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61643-352:2018 covers the application of surge isolation transformers (SITs) that are used in telecommunication transformer applications with signal levels up to 400 V peak to peak. These transformers have a high rated impulse voltage with or without screen between the input and output windings. SITs are components for surge protection and are used to mitigate the onward propagation of common-mode voltage surges. This document describes SITs' selection, application principles and related information. This document does not cover power line communication transformers. Keywords: surge isolation transformers (SITs), telecommunication transformer applications

  • Standard
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61643-351:2016 defines test circuits and test methods for determining and verifying the SIT surge parameters. Preferred performance values for key parameters are given. Surge isolation transformers (SITs) are used for signal transformer applications with signal levels up to 400 V peak to peak. SITs are transformers, with or without an internal-winding screen, with a rated impulse withstand voltage greater than the peak voltage of the expected common-mode surge environment. SITs are applicable to components for surge protection against indirect and direct effects of lightning or other transient overvoltage. SITs are used to mitigate the onward propagation of common-mode voltage surges. This part of IEC 61643 does not cover SIT operation under differential-mode lightning surge conditions. Keywords: Surge isolation transformers (SITs)

  • Standard
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 61643 covers the application of surge isolation transformers (SITs) that are
used in telecommunication transformer applications with signal levels up to 400 V peak to
peak. These transformers have a high rated impulse voltage with or without screen between
the input and output windings. SITs are components for surge protection and are used to
mitigate the onward propagation of common-mode voltage surges. This document describes
SITs' selection, application principles and related information. This document does not cover
power line communication transformers.

  • Standard
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

The present document specifies technical characteristics and methods of measurements for TV white space devices
(TVWSDs) controlled by a TV white space database (TVWSDB) and which operate in the TV broadcast band
470 MHz to 790 MHz.
The present document applies to the following radio equipment types:
1) Master TV white space device (TVWSD)
2) Slave TV white space device (TVWSD)
The present document applies to TVWSDs with integral, dedicated or external antennas, where TVWSDs using external
antennas are intended only for fixed use.
The present document covers the essential requirements of article 3.2 of Directive 2014/53/EU [i.3] under the
conditions identified in annex A.

  • Standard
    77 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    77 pages
    English language
    sale 15% off
  • Standard
    77 pages
    English language
    sale 15% off
  • Standard
    77 pages
    English language
    sale 15% off

IEC 61643-352:2018 covers the application of surge isolation transformers (SITs) that are used in telecommunication transformer applications with signal levels up to 400 V peak to peak. These transformers have a high rated impulse voltage with or without screen between the input and output windings. SITs are components for surge protection and are used to mitigate the onward propagation of common-mode voltage surges. This document describes SITs' selection, application principles and related information. This document does not cover power line communication transformers.

  • Standard
    43 pages
    English and French language
    sale 15% off

Surge isolation transformers (SITs) are used for signal transformer applications with signal
levels up to 400 V peak to peak. SITs are transformers, with or without an internal-winding
screen, with a rated impulse withstand voltage greater than the peak voltage of the expected
common-mode surge environment. SITs are applicable to components for surge protection
against indirect and direct effects of lightning or other transient overvoltage. SITs are used to
mitigate the onward propagation of common-mode voltage surges. This part of IEC 61643
defines test circuits and test methods for determining and verifying the SIT surge parameters.
Preferred performance values for key parameters are given.
This part of IEC 61643 does not cover SIT operation under differential-mode lightning surge
conditions.

  • Standard
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61643-351:2016 defines test circuits and test methods for determining and verifying the SIT surge parameters. Preferred performance values for key parameters are given. Surge isolation transformers (SITs) are used for signal transformer applications with signal levels up to 400 V peak to peak. SITs are transformers, with or without an internal-winding screen, with a rated impulse withstand voltage greater than the peak voltage of the expected common-mode surge environment. SITs are applicable to components for surge protection against indirect and direct effects of lightning or other transient overvoltage. SITs are used to mitigate the onward propagation of common-mode voltage surges. This part of IEC 61643 does not cover SIT operation under differential-mode lightning surge conditions. Keywords: Surge isolation transformers (SITs)

  • Standard
    54 pages
    English and French language
    sale 15% off

IEC 61643-312:2013 is applicable to gas discharge tubes (GDT) used for overvoltage protection in telecommunications, signalling and low-voltage power distribution networks with nominal system voltages up to 1 000 V (r.m.s.) a.c. and 1 500 V d.c. They are defined as a gap, or several gaps with two or three metal electrodes hermetically sealed so that gas mixture and pressure are under control. They are designed to protect apparatus or personnel, or both, from high transient voltages. This standard provides information about the characteristics and circuit applications of GDTs having two or three electrodes. This standard does not specify requirements applicable to complete surge protective devices, nor does it specify total requirements for GDTs employed within electronic devices, where precise coordination between GDT performance and surge protective device withstand capability is highly critical. Keywords: gas discharge tubes (GDT), overvoltage protection in telecommunications, signalling and low-voltage power distribution networks, nominal system voltages up to 1 000 V (r.m.s.) a.c. and 1 500 V d.c.

  • Standard
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61643-311:2013 is applicable to gas discharge tubes (GDT) used for overvoltage protection in telecommunications, signalling and low-voltage power distribution networks with nominal system voltages up to 1 000 V (r.m.s.) a.c. and 1 500 V d.c..They are defined as a gap, or several gaps with two or three metal electrodes hermetically sealed so that gas mixture and pressure are under control. They are designed to protect apparatus or personnel, or both, from high transient voltages. This standard contains a series of test criteria, test methods and test circuits for determining the electrical characteristics of GDTs having two or three electrodes. This standard does not specify requirements applicable to complete surge protective devices, nor does it specify total requirements for GDTs employed within electronic devices, where precise coordination between GDT performance and surge protective device withstand capability is highly critical. This second edition of IEC 61643-311 cancels and replaces the first edition published in 2001. It constitutes a technical revision. Specific changes with respect to the previous edition are: Addition of performance values. Key words: gas discharge tubes (GDT), overvoltage protection in telecommunications, signalling and low-voltage power distribution networks, nominal system voltages up to 1 000 V (r.m.s.) a.c. and 1 500 V d.c.

  • Standard
    30 pages
    English language
    sale 10% off
    e-Library read for
    1 day

The present document applies to TV white space devices (TVWSDs) controlled by a TV white space database (TVWSDB) and which operate in the TV broadcast band 470 MHz to 790 MHz. The present document applies to the following radio equipment types:
1) Master TV white space device (TVWSD)
2) Slave TV white space device (TVWSD)
The present document applies to TVWSDs with integral, dedicated or external antennas, where TVWSDs using external antennas are intended only for fixed use. The present document is intended to cover the provisions of Directive
1999/5/EC [i.3] (R&TTE Directive), Article 3.2, which states that "….. radio equipment shall be so constructed that it effectively uses the spectrum allocated to terrestrial/space radio communications and orbital resources so as to avoid harmful interference". In addition to the present document, other ENs that specify technical requirements in respect of essential requirements under other parts of article 3 of the R&TTE Directive may apply to equipment within the scope of the present document.
NOTE: A list of such ENs is included on the web site http://www.newapproach.org.

  • Standard
    72 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    72 pages
    English language
    sale 15% off
  • Standard
    72 pages
    English language
    sale 15% off
  • Standard
    71 pages
    English language
    sale 15% off
  • Draft
    71 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61643-312:2013 is applicable to gas discharge tubes (GDT) used for overvoltage protection in telecommunications, signalling and low-voltage power distribution networks with nominal system voltages up to 1 000 V (r.m.s.) a.c. and 1 500 V d.c. They are defined as a gap, or several gaps with two or three metal electrodes hermetically sealed so that gas mixture and pressure are under control. They are designed to protect apparatus or personnel, or both, from high transient voltages. This standard provides information about the characteristics and circuit applications of GDTs having two or three electrodes. This standard does not specify requirements applicable to complete surge protective devices, nor does it specify total requirements for GDTs employed within electronic devices, where precise coordination between GDT performance and surge protective device withstand capability is highly critical. Keywords: gas discharge tubes (GDT), overvoltage protection in telecommunications, signalling and low-voltage power distribution networks, nominal system voltages up to 1 000 V (r.m.s.) a.c. and 1 500 V d.c. The contents of the corrigendum of July 2013 have been included in this copy.

  • Standard
    43 pages
    English and French language
    sale 15% off

IEC 61643-311:2013 is applicable to gas discharge tubes (GDT) used for overvoltage protection in telecommunications, signalling and low-voltage power distribution networks with nominal system voltages up to 1 000 V (r.m.s.) a.c. and 1 500 V d.c..They are defined as a gap, or several gaps with two or three metal electrodes hermetically sealed so that gas mixture and pressure are under control. They are designed to protect apparatus or personnel, or both, from high transient voltages. This standard contains a series of test criteria, test methods and test circuits for determining the electrical characteristics of GDTs having two or three electrodes. This standard does not specify requirements applicable to complete surge protective devices, nor does it specify total requirements for GDTs employed within electronic devices, where precise coordination between GDT performance and surge protective device withstand capability is highly critical. This second edition of IEC 61643-311 cancels and replaces the first edition published in 2001. It constitutes a technical revision. Specific changes with respect to the previous edition are: Addition of performance values. Key words: gas discharge tubes (GDT), overvoltage protection in telecommunications, signalling and low-voltage power distribution networks, nominal system voltages up to 1 000 V (r.m.s.) a.c. and 1 500 V d.c.

  • Standard
    53 pages
    English and French language
    sale 15% off

This European Standard specifies the environmental conditions encountered within Europe. It can also be applied elsewhere by agreement between the supplier and the customer.
The scope of this European Standard covers the design and the use of equipment and any portable equipment for signalling and telecommunications systems (including test, measure, monitoring equipment, etc.).
The portable equipment must comply with the sections of this European Standard relevant to their use.
This European Standard does not specify the test requirements for equipment.
In particular the standard intends to define
–   interface conditions between the equipment and its environment,
–   parameters to be used by designers when calculating R.A.M.S. and life time with respect to environmental condition effects.
In this respect it gives general guidance in order to allow consistent assessments of contract documentation for European projects.
The defined environmental conditions are considered as normal in service.
Microclimates surrounding components may need special requirements to be defined by the product standard.
The effects of any signalling and telecommunications equipment (in either or failure mode of operation) on the overall signalling system safety are not within the scope of this European Standard. This European Standard does not provide the designer with information to enable him to determine the safety risk associated with environmental conditions. The safety of persons in the vicinity of (or working on) the signalling and telecommunications equipment is also out of the scope of this European Standard. The effects of vandalism on the equipment are not considered in this European Standard.
This European Standard applies to all signalling and telecommunications systems except those used for cranes, mining vehicles and cable cars. It does not define the specifications for train-borne signalling and telecommunications systems.
The train-borne signalling and telecommunications systems must comply with rolling stock environmental conditions specifications (EN 50125-1).

  • Standard
    28 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Objective is to limit the number of possible primary failures occurring in the optical fibre cable in a specified installation to within values which are lower than or equal to the limit value, defined as the tolerable frequency of primary failures. Gives the method for calculating the possible number of primary failures, choosing the feasible protective measures and indicating the tolerable frequency of primary failures. Secondary failures are not considered. The tests described in annex G are convenient only for the risk evaluation associated with lightning in fibre optic installations. Tests for the qualification of a cable design are outside the scope of this standard.

  • Standard
    36 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Gas discharge tubes (GDTs) are used for applications up to 1 000 V a.c. or 1 500 V d.c. in communication or signalling circuits. They are defined as a gap, or series of gaps, in an enclosed discharge medium other than air. They are designed to protect apparatus or personnel, or both, from high transient voltages. This standard does not specify requirements applicable to complete surge protective devices, nor does it specify total requirements for GDTs employed within electronic devices, where precise coordination between GDT performance and surge protective device withstand capability is highly critical.

  • Standard
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Objective is to limit the number of possible primary failures occurring in the optical fibre cable in a specified installation to within values which are lower than or equal to the limit value, defined as the tolerable frequency of primary failures. Gives the method for calculating the possible number of primary failures, choosing the feasible protective measures and indicating the tolerable frequency of primary failures. Secondary failures are not considered. The tests described in annex G are convenient only for the risk evaluation associated with lightning in fibre optic installations. Tests for the qualification of a cable design are outside the scope of this standard.

  • Standard
    36 pages
    English language
    sale 10% off
    e-Library read for
    1 day