This Part of (pr/Fpr)EN 15269, which should be read in conjunction with FprEN 15269-1, covers hinged and pivoted steel doorsets, hinged and pivoted timber doorsets (including timber framed glazed doorsets) and hinged and pivoted metal framed glazed doorsets of single or double-leaf construction.
The document prescribes the methodology for extending the application of test results obtained from test(s) conducted in accordance with EN 1634-3.
NOTE    It is anticipated that the above scope will be...
view more

    • sale 10% off
    • Standard
      193 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      183 pages
      English language
    • e-Library read for
      1 day

This document specifies the test method for determining the force required when engaging or releasing the hardware of a window and when commencing the movement of a casement or sash, in both opening and closing directions.
This document is applicable to windows where the movement of the casement or sash is a manual operation.
This document is applicable to products of any frame material.

    • sale 10% off
    • Standard
      11 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      11 pages
      English language
    • e-Library read for
      1 day

This Part of EN 1366 specifies a method for determining the fire resistance of vertical and horizontal ventilation ducts including those access panels, which are integral part of the tested ducts. The test examines the behaviour of ducts exposed to fire from the outside (duct A) and fire inside the duct (duct B). This Standard is used in conjunction with EN1363-1.
Annex A provides general guidance and gives background information.
This European Standard is not applicable to:
a)   ducts whos...
view more

    • sale 10% off
    • Standard
      50 pages
      English language
    • e-Library read for
      1 day

This document provides a means of classifying the performance of opening windows according to their strength in resisting, where appropriate, racking load, static torsion and their operating forces. Special aspects such as those of burglar resistance are not covered.

    • sale 10% off
    • Standard
      6 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      6 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies requirements and test methods for rain caps that are used as components, subject to flue gas, in order to prevent rain entry into the chimneys. Rain caps already tested together with system chimney products or other chimney components, e.g. terminals, are not covered by this standard. Rain caps incorporating a bird guard are also included. It also specifies the requirements for marking, manufacturers’ instruction, product information and evaluation of conformity.

    • sale 10% off
    • Standard
      28 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies the classifications, requirements and test methods for non-coated unplasticized poly(vinyl chloride) (PVC-U) profiles with light coloured surfaces intended to be used for the fabrication of windows and doors.
It is applicable to PVC-U profiles with the colorimetric co-ordinates measured on the visible surfaces, as follows:
-   L* ≥ 82 (chromaticity co-ordinate Y ≥ 60),
-   -2,5 ≤ a* ≤ 5,
-   -5 ≤ b* ≤ 15.
NOTE 1   For editorial reasons in this document the term "win...
view more

    • sale 10% off
    • Standard
      26 pages
      English language
    • e-Library read for
      1 day

This document specifies procedures to determine the impact sound insulation using sound pressure measurements with an impact source operating on a floor or stairs in a building. These procedures are intended for room volumes in the range from 10 m3 to 250 m3 in the frequency range from 50 Hz to 5 000 Hz. The test results can be used to quantify, assess and compare the impact sound insulation in unfurnished or furnished rooms where the sound field may or may not approximate to a diffuse field.

    • sale 15% off
    • Standard
      44 pages
      English language
    • sale 15% off
    • Standard
      45 pages
      French language
    • sale 15% off
    • Draft
      44 pages
      English language

This European Standard specifies a method of test for determining the reaction to fire performance of construction products excluding floorings, and excluding products which are indicated in Table 1 of EC Decision 2000/147/EC, when exposed to thermal attack by a single burning item (SBI). The calculation procedures are given in Annex A. Information on the precision of the test method is given in Annex B. The calibration procedures are given in Annexes C and D, of which C is a normative annex.
N...
view more

    • sale 10% off
    • Standard
      104 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      121 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies requirements of curtain walling kit intended to be used as a building envelope to provide weather resistance, safety in use and energy economy and heat retention and provides test/assessments/calculation methods and compliance criteria of the related performances.
The curtain walling kit covered by this standard should fulfil its own integrity and mechanical stability but does not contribute to the load bearing or stability of the main building structure, and co...
view more

    • sale 10% off
    • Standard
      90 pages
      English language
    • e-Library read for
      1 day

This European standard specifies the requirements and test methods for flue dampers that are used as
components, carrying flue gas, in order to limit the flow in a chimney.
Flue dampers may be manually adjusted, sited in connecting flue pipes or chimneys, in order to reduce the burning rate (solid fuel stoves/fireplaces) or to work as a shut-off slide preventing back flow of soot during cleaning of the chimney, or mechanically driven for reducing/closing the flue, in order to reduce the Stand-...
view more

    • sale 10% off
    • Standard
      42 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      46 pages
      English language
    • e-Library read for
      1 day

This document sets out the general principles for the extended application of test results obtained on fire resisting and smoke control doorsets, e.g. the types of pedestrian and industrial doors, operable fabric curtains and openable windows listed in the Introduction above when tested in accordance with EN 1634-1 and/or EN 1634-3.
This document provides the general principles which are intended to be used in conjunction with the relevant part of EN 15269 depending upon the specific product ty...
view more

    • sale 10% off
    • Corrigendum
      2 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies the requirements and test methods for access components comprising a frame and a door or doors which provide access to the flue of a chimney for the purpose of inspection or cleaning.
Access components for higher nominal working temperature than 450 °C, positive pressure and wet applications are not covered by this standard.
The standard is limited to access components with a door opening area up to 0,27 m2.
Products not freely ventilated are excluded from thi...
view more

    • sale 10% off
    • Standard
      33 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      35 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies requirements and test methods for flue gas silencers made of metal that are used as accessories in order to reduce the noise level of combustions appliances.
The standard covers silencers in the connecting flue pipes and on top of chimneys.
This standard does not cover silencers installed as chimney sections. This standard excludes active silencers.

    • sale 10% off
    • Standard
      29 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      29 pages
      English language
    • e-Library read for
      1 day

This document specifies the characteristics and test methods for flue dampers that are used as components, carrying flue gas, in order to limit the flow in a chimney or to prevent back flow of soot during cleaning of the chimney or to prevent the backflow of the flue gas e.g. in case of multi-served chimneys.
This document covers only flue dampers incorporated in a housing and installed inside a building.
This document covers only flue dampers with sealings made of elastomeric materials for te...
view more

    • sale 10% off
    • Standard
      42 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      46 pages
      English language
    • e-Library read for
      1 day

This document sets out the general principles for the extended application of test results obtained on fire resisting and smoke control doorsets, e.g. the types of pedestrian and industrial doors, operable fabric curtains and openable windows listed in the Introduction above when tested in accordance with EN 1634-1 and/or EN 1634-3.
This document provides the general principles which are intended to be used in conjunction with the relevant part of EN 15269 depending upon the specific product ty...
view more

    • sale 10% off
    • Corrigendum
      2 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies requirements and test methods for flue gas silencers made of metal that are used as accessories in order to reduce the noise level of combustions appliances.
The standard covers silencers in the connecting flue pipes and on top of chimneys.
This standard does not cover silencers installed as chimney sections. This standard excludes active silencers.

    • sale 10% off
    • Standard
      29 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      29 pages
      English language
    • e-Library read for
      1 day

This document specifies the requirements and test methods for access components comprising a frame and a door or doors which provide access to the flue of a chimney for the purpose of inspection or cleaning.
Access components for higher nominal working temperature than 450 °C, positive pressure and wet applications are not covered by this standard.
The document is limited to access components with door opening dimensions with a maximum width of 450 mm and a maximum height of 600 mm.
Products ...
view more

    • sale 10% off
    • Standard
      33 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      35 pages
      English language
    • e-Library read for
      1 day

This European Standard provides product category rules (PCR) for Type III environmental declarations for windows and pedestrian doorsets as defined in EN 14351 1, prEN 14351 2. Windows and pedestrian doorsets with fire resistance and/or smoke control characteristics according to EN 16034 are also covered by this standard.
NOTE   Windows that incorporate shutters and/or shutter boxes and/or blinds are in scope of this PCR. For any connected electrical devices (e.g. motors, sensors) - see 6.3.4.2
...
view more

    • sale 10% off
    • Standard
      26 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      24 pages
      English language
    • e-Library read for
      1 day

This document provides product category rules (PCR) for Type III environmental declarations for windows and pedestrian doorsets as defined in EN 14351-1 and EN 14351-2. Windows and pedestrian doorsets additionally providing fire resistance and/or smoke control characteristics according to EN 16034 are also covered by this document.
NOTE 1   Windows that incorporate shutters and/or shutter boxes and/or blinds are in scope of this PCR. For any connected electrical devices (e.g. motors, sensors) -se...
view more

    • sale 10% off
    • Standard
      26 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      24 pages
      English language
    • e-Library read for
      1 day

This document specifies the characteristics of individual hardwood boards and pre-assembled hardwood boards with grooves and/or tongues for internal use as flooring. This document covers hardwood boards with or without surface coating.
This document does not cover solid parquet elements. (See Annex C).

    • sale 10% off
    • Standard
      25 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      25 pages
      English language
    • e-Library read for
      1 day