This document a) defines single-number quantities for airborne sound insulation in buildings and of building elements such as walls, floors, doors, and windows, b) takes into consideration the different sound level spectra of various noise sources such as noise sources inside a building and traffic outside a building, and c) gives rules for determining these quantities from the results of measurements carried out in one-third-octave or octave bands for example in accordance with ISO 10140-2 and ...view more

    • sale 15% off
    • Standard
      28 pages
      French language
    • sale 15% off
    • Draft
      28 pages
      French language
    • sale 15% off
    • Standard
      26 pages
      English language
    • sale 15% off
    • Draft
      26 pages
      English language
    • sale 15% off
    • Draft
      27 pages
      French language
    • sale 15% off
    • Draft
      23 pages
      English language

This document a) defines single-number quantities for impact sound insulation in buildings and of floors, b) gives rules for determining these quantities from the results of measurements carried out in one-third-octave bands in accordance with ISO 10140-3 and ISO 16283-2, and in octave bands in accordance with that option in ISO 16283-2 for field measurements only, c) defines single-number quantities for the impact sound reduction of floor coverings and floating floors calculated from the result...view more

    • sale 15% off
    • Standard
      23 pages
      English language
    • sale 15% off
    • Standard
      23 pages
      French language
    • sale 15% off
    • Draft
      23 pages
      French language
    • sale 15% off
    • Draft
      23 pages
      English language
    • sale 15% off
    • Draft
      21 pages
      English language
    • sale 15% off
    • Draft
      24 pages
      French language

ISO 10848 (all parts) specifies measurement methods to characterize the flanking transmission of one
or several building components. This document considers only laboratory measurements.
This part of ISO 10848 specifies measurement methods to be performed in a laboratory to characterize
the acoustic radiation of a building element when mechanically or acoustically excited. The measured
quantities can be used to compare products, or to express a requirement, or as input data for prediction
m...
view more

    • sale 10% off
    • Standard
      18 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      15 pages
      English language
    • e-Library read for
      1 day

EN-ISO 5135 establishes general rules for the acoustic testing of air-terminal devices, air-terminal units, dampers and valves used in air diffusion and air distribution systems in order to determine sound power levels as defined in ISO 3741.

    • sale 10% off
    • Standard
      22 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      20 pages
      English language
    • e-Library read for
      1 day

This document specifies how to calculate:
— the uncertainty of sound absorption coefficients and equivalent sound absorption areas measured
according to ISO 354;
— the uncertainty of the practical and weighted sound absorption coefficients determined according
to ISO 11654;
— the uncertainty of the object sound absorption coefficient according to ISO 20189; and
— the uncertainty of the single number rating determined according to EN 1793-1.
Furthermore, the use of uncertainties in reporti...
view more

    • sale 10% off
    • Standard
      16 pages
      English language
    • e-Library read for
      1 day

EN-ISO 16283-2 specifies procedures to determine the impact sound insulation using sound pressure measurements with an impact source operating on a floor or stairs in a building. These procedures are intended for room volumes in the range from 10 m3 to 250 m3 in the frequency range from 50 Hz to 5 000 Hz. The test results can be used to quantify, assess and compare the impact sound insulation in unfurnished or furnished rooms where the sound field may or may not approximate to a diffuse field.

    • sale 10% off
    • Standard
      53 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      50 pages
      English language
    • e-Library read for
      1 day

This document specifies measurement methods to characterize in the laboratory the acoustic radiation of a building element when it is directly excited by an airborne or structure-borne source. It is applicable to single-leaf and double-leaf elements (see ISO 12354-1:2017 Annex F, F2). The measured quantity can be used as input data for prediction methods, such as ISO 12354-1 and ISO 12354-2, to compare products, or to express a requirement.

    • sale 15% off
    • Standard
      10 pages
      French language
    • sale 15% off
    • Standard
      10 pages
      English language
    • sale 15% off
    • Standard
      10 pages
      French language
    • sale 15% off
    • Draft
      10 pages
      English language

This document specifies procedures to determine the impact sound insulation using sound pressure measurements with an impact source operating on a floor or stairs in a building. These procedures are intended for room volumes in the range from 10 m3 to 250 m3 in the frequency range from 50 Hz to 5 000 Hz. The test results can be used to quantify, assess and compare the impact sound insulation in unfurnished or furnished rooms where the sound field may or may not approximate to a diffuse field.

    • sale 15% off
    • Standard
      44 pages
      English language
    • sale 15% off
    • Standard
      45 pages
      French language
    • sale 15% off
    • Draft
      44 pages
      English language

This document specifies a laboratory substitution method to determine the insertion loss without flow of ducted, mainly absorbent, circular and rectangular silencers, as well as other duct elements for use in ventilating and air-conditioning systems. NOTE Laboratory measurement procedures for ducted silencers with superimposed flow are described in ISO 7235[5]. This document is applicable to silencers where the design velocity does not exceed 15 m/s. As the method does not include self-generated...view more

    • sale 15% off
    • Standard
      9 pages
      French language
    • sale 15% off
    • Standard
      8 pages
      English language

This document specifies a laboratory method to facilitate the comparison of furniture ensembles and enclosures with respect to their ability to reduce the speech level of the occupant speaking inside the product. In this method, the sound power level is measured in two scenarios: 1) without the product, and 2) with the product. During scenario 1), the test signal is produced by the sound source in an empty room while the product is absent. During scenario 2), the test signal is produced by the s...view more

    • sale 15% off
    • Standard
      14 pages
      English language
    • sale 15% off
    • Standard
      15 pages
      French language
    • sale 15% off
    • Draft
      14 pages
      English language

This document specifies how to calculate: — the uncertainty of sound absorption coefficients and equivalent sound absorption areas measured according to ISO 354; — the uncertainty of the practical and weighted sound absorption coefficients determined according to ISO 11654; — the uncertainty of the object sound absorption coefficient according to ISO 20189; and — the uncertainty of the single number rating determined according to EN 1793‑1. Furthermore, the use of uncertainties in reporting meas...view more

    • sale 15% off
    • Standard
      8 pages
      English language
    • sale 15% off
    • Standard
      8 pages
      French language
    • sale 15% off
    • Draft
      8 pages
      English language

This document specifies procedures for assessing the measurement uncertainty of sound insulation in building acoustics. It provides for — a detailed uncertainty assessment; — a determination of uncertainties by inter-laboratory tests; — an application of uncertainties. Furthermore, typical uncertainties are given for quantities determined according to ISO 10140 (all parts), ISO 16283 (all parts) and ISO 717 (all parts).

    • sale 15% off
    • Standard
      21 pages
      English language
    • sale 15% off
    • Standard
      21 pages
      French language

This European Standard assigns sound insulation values to all transparent, translucent and opaque glass products, described in the European Standards for basic, special basic or processed glass products, when intended to be used in glazed assemblies in buildings, and which exhibit properties of acoustic protection, either as a prime intention or as a supplementary characteristic.
This document outlines the procedure, by which glass products may be rated, according to their acoustic performance ...
view more

    • sale 10% off
    • Standard
      16 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      15 pages
      English language
    • e-Library read for
      1 day

This European Standard assigns sound insulation values to all transparent, translucent and opaque glass products, described in the European Standards for basic, special basic or processed glass products, when intended to be used in glazed assemblies in buildings, and which exhibit properties of acoustic protection, either as a prime intention or as a supplementary characteristic.
This document outlines the procedure, by which glass products may be rated, according to their acoustic performance ...
view more

    • sale 10% off
    • Standard
      16 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      15 pages
      English language
    • e-Library read for
      1 day

This document specifies how screens, furniture and single objects intended for interior use are assessed with regard to sound absorption and specifies the evaluation of sound attenuation for floor screens. It also specifies under which circumstances various interior products for offices, schools and other public spaces are considered as plane absorbers or as discrete single objects. A product considered as a single object and intended for interior use is measured according to ISO 354 and evaluat...view more

    • sale 15% off
    • Standard
      28 pages
      English language

The goal of this document is to indicate how to present the uncertainty data determined by EN ISO 12999-1 in a test report of the Sound reduction index R of a building product or a building system complying with EN ISO 717-1 and EN ISO 10140-2:2010, Figure B1.

    • sale 10% off
    • Technical report
      6 pages
      English language
    • e-Library read for
      1 day

The purpose of this document is to indicate how to present the uncertainty data determined by EN ISO 12999-1 in a laboratory test report of the Sound reduction index R of a building product or a building system, determined in accordance with EN ISO 717-1 and EN ISO 10140-2:2010, Figure B.1. It is planned to include this information in EN ISO 10140-2.

    • sale 10% off
    • Technical report
      6 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies a laboratory measurement method to determine noise radiated from a floor covering on a standard concrete floor when excited by a standard tapping machine.

    • sale 10% off
    • Standard
      18 pages
      English language
    • e-Library read for
      1 day

ISO 10848 (all parts) specifies measurement methods to characterize the flanking transmission of one
or several building components.
This document specifies laboratory and field measurements of buildings for Type B elements (defined
in ISO 10848-1) when the junction has a substantial influence.
Laboratory measurements are used to quantify the performance of the junction with suppressed
flanking transmission from the laboratory structure. Field measurements are used to characterize
the in s...
view more

    • sale 10% off
    • Standard
      15 pages
      English language
    • e-Library read for
      1 day

ISO 10848 (all parts) specifies measurement methods to characterize the flanking transmission of one
or several building components. These measurements are performed in a laboratory test facility or in
the field.
The performance of the building components is expressed either as an overall quantity for the
combination of elements and junction (such as the normalized flanking level difference and/or
normalized flanking impact sound pressure level) or as the vibration reduction index of a junc...
view more

    • sale 10% off
    • Standard
      43 pages
      English language
    • e-Library read for