Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 6: Wedge meters (ISO 5167-6:2022)

This document specifies the geometry and method of use (installation and operating conditions) of wedge meters when they are inserted in a conduit running full to determine the flow rate of the fluid flowing in the conduit.
NOTE 1    As the uncertainty of an uncalibrated wedge meter can be too large for a particular application, it could be deemed essential to calibrate the flow meter according to Clause 7.
This document gives requirements for calibration which, if applied, are for use over the calibrated Reynolds number range. Clause 7 could also be useful guidance for calibration of meters of similar design but which fall outside the scope of this document.
It also provides background information for calculating the flow rate and is applicable in conjunction with the requirements given in ISO 5167‑1.
This document is applicable only to wedge meters in which the flow remains subsonic throughout the measuring section and where the fluid can be considered as single-phase. Uncalibrated wedge meters can only be used within specified limits of pipe size, roughness, β (or wedge ratio) and Reynolds number. It is not applicable to the measurement of pulsating flow. It does not cover the use of uncalibrated wedge meters in pipes whose internal diameter is less than 50 mm or more than 600 mm, or where the pipe Reynolds numbers are below 1 × 104.
NOTE 2    A wedge meter has a primary element which consists of a wedge-shaped restriction of a specific geometry. Alternative designs of wedge meters are available; however, at the time of writing there is insufficient data to fully characterize these devices, and therefore these meters are calibrated in accordance with Clause 7.

Durchflussmessung von Fluiden mit Drosselgeräten in voll durchströmten Leitungen mit Kreisquerschnitt - Teil 6: Keil-Durchflussmesser (ISO 5167-6:2022)

Dieses Dokument legt die geometrischen Formen und Maße sowie die Anwendung (Einbau- und Betriebsbe
dingungen) von Keil-Durchflussmessern fest, die in voll durchströmte Leitungen eingebaut werden, um den Durchfluss des in der Leitung strömenden Fluids zu bestimmen.
ANMERKUNG1 Da die Messunsicherheit eines unkalibrierten Keil-Durchflussmessers für bestimmte Anwendungsfälle zu groß sein kann, könnte eine Kalibrierung des Durchflussmessers nach Abschnitt7 erforderlich sein.
Dieses Dokument enthält Anforderungen an die Kalibrierung, die, wenn sie angewendet werden, für den kali
brierten Bereich der Reynolds-Zahlen gelten. Abschnitt7 könnte auch ein nützlicher Leitfaden für die Kali
brierung von Durchflussmessern ähnlicher Ausführung sein, die jedoch nicht in den Anwendungsbereich des vorliegenden Dokuments fallen.
Dieses Dokument ist anwendbar in Verbindung mit den in ISO5167-1 festgelegten Anforderungen und enthält auch Hintergrundinformationen für die Berechnung des Durchflusses.
Dieses Dokument ist ausschließlich für Keil-Durchflussmesser anwendbar, in denen die Strömung in allen Messquerschnitten im Unterschallbereich liegt und das Fluid als einphasig betrachtet werden kann. Unkali
brierte Keil-Durchflussmesser können lediglich innerhalb festgelegter Grenzen von Rohrdurchmesser,
heit, β-Wert (oder Keilverhältnis) und Reynolds-Zahl angewendet werden. Dieses Dokument ist nicht für
sungen von pulsierenden Strömungen anwendbar. Es behandelt nicht die Anwendung von unkalibrierten Keil- Durchflussmessern in Rohrleitungen, deren Innendurchmesser geringer als 50mm oder größer als 600mm ist, oder wenn die auf den Rohrdurchmesser bezogene Reynolds-Zahl unter 1×104 liegt.
ANMERKUNG2 Ein Keil-Durchflussmesser verfügt über ein Primärelement, das aus einer keilförmigen Verengung mit spezifischen geometrischen Formen und Maßen besteht. Es stehen alternative Ausführungen von Keil-Durchflussmessern zur Verfügung; zum Zeitpunkt der Erstellung der Norm gibt es jedoch nicht genügend Daten, um diese Drosselgeräte voll
ständig zu beschreiben, weshalb diese Durchflussmesser nach Abschnitt7 kalibriert werden.

Mesurage de débit des fluides au moyen d'appareils déprimogènes insérés dans des conduites en charge de section circulaire - Partie 6: Débitmètres à coin (ISO 5167-6:2022)

Le présent document spécifie la géométrie et le mode d’emploi (conditions d’installation et d’utilisation) de débitmètres à coin insérés dans une conduite en charge dans le but de déterminer le débit du fluide s’écoulant dans cette conduite.
NOTE 1    Étant donné que l’incertitude d’un débitmètre à coin non étalonné risque d’être trop grande pour une application particulière, l’étalonnage du débitmètre conformément à l’Article 7 peut être considéré comme essentiel.
Le présent document fournit des exigences relatives à l’étalonnage qui, si elles sont appliquées, sont destinées à être utilisées sur la plage des nombres de Reynolds qui a été étalonnée. L’Article 7 peut également fournir des recommandations utiles relatives à l’étalonnage des appareils de mesure de conception similaire, mais qui n’entrent pas dans le domaine d’application du présent document.
Il fournit également des informations de fond nécessaires au calcul du débit et il est applicable conjointement avec les exigences stipulées dans l’ISO 5167‑1.
Le présent document est applicable uniquement aux débitmètres à coin pour lesquels l’écoulement reste subsonique dans tout le tronçon de mesure et où le fluide peut être considéré comme monophasique. Les débitmètres à coin non étalonnés ne peuvent être utilisés que dans des limites spécifiées de diamètre de conduite, de rugosité, de valeur de β (ou rapport du coin) et de nombre de Reynolds. Ce document n’est pas applicable au mesurage d’un écoulement pulsé. Il ne couvre pas l’utilisation de débitmètres à coin non étalonnés dans des conduites dont le diamètre intérieur est inférieur à 50 mm ou supérieur à 600 mm, ni les cas où les nombres de Reynolds associés à la tuyauterie sont inférieurs à 1 × 104.
NOTE 2    Un débitmètre à coin comporte un élément primaire composé d’une restriction en forme de coin de géométrie spécifique. D’autres conceptions de débitmètres à coin sont possibles; cependant, au moment de la rédaction du présent document, les données permettant de caractériser complètement ces appareils étaient insuffisantes et ces derniers sont donc étalonnés conformément à l’Article 7.

Merjenje pretoka fluida na osnovi tlačne razlike, povzročene z napravo, vstavljeno v polno zapolnjen vod s krožnim prerezom - 6. del: Merilniki klinov (ISO 5167-6:2022)

General Information

Status
Published
Publication Date
01-Nov-2022
Current Stage
6060 - Definitive text made available (DAV) - Publishing
Start Date
02-Nov-2022
Completion Date
02-Nov-2022

Relations

Buy Standard

Standard
EN ISO 5167-6:2022
English language
21 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN ISO 5167-6:2022
01-december-2022
Nadomešča:
SIST EN ISO 5167-6:2019
Merjenje pretoka fluida na osnovi tlačne razlike, povzročene z napravo, vstavljeno
v polno zapolnjen vod s krožnim prerezom - 6. del: Merilniki klinov (ISO 5167-
6:2022)
Measurement of fluid flow by means of pressure differential devices inserted in circular
cross-section conduits running full - Part 6: Wedge meters (ISO 5167-6:2022)
Durchflussmessung von Fluiden mit Drosselgeräten in voll durchströmten Leitungen mit
Kreisquerschnitt - Teil 6: Keil-Durchflussmesser (ISO 5167-6:2022)
Mesurage de débit des fluides au moyen d'appareils déprimogènes insérés dans des
conduites en charge de section circulaire - Partie 6: Débitmètres à coin (ISO 5167-
6:2022)
Ta slovenski standard je istoveten z: EN ISO 5167-6:2022
ICS:
17.120.10 Pretok v zaprtih vodih Flow in closed conduits
SIST EN ISO 5167-6:2022 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
SIST EN ISO 5167-6:2022

---------------------- Page: 2 ----------------------
SIST EN ISO 5167-6:2022


EN ISO 5167-6
EUROPEAN STANDARD

NORME EUROPÉENNE

November 2022
EUROPÄISCHE NORM
ICS 17.120.10 Supersedes EN ISO 5167-6:2019
English Version

Measurement of fluid flow by means of pressure
differential devices inserted in circular cross-section
conduits running full - Part 6: Wedge meters (ISO 5167-
6:2022)
Mesurage de débit des fluides au moyen d'appareils Durchflussmessung von Fluiden mit Drosselgeräten in
déprimogènes insérés dans des conduites en charge de voll durchströmten Leitungen mit Kreisquerschnitt -
section circulaire - Partie 6: Débitmètres à coin (ISO Teil 6: Keil-Durchflussmesser (ISO 5167-6:2022)
5167-6:2022)
This European Standard was approved by CEN on 25 September 2022.

CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.

This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and
United Kingdom.





EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2022 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN ISO 5167-6:2022 E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------
SIST EN ISO 5167-6:2022
EN ISO 5167-6:2022 (E)
Contents Page
European foreword . 3

2

---------------------- Page: 4 ----------------------
SIST EN ISO 5167-6:2022
EN ISO 5167-6:2022 (E)
European foreword
This document (EN ISO 5167-6:2022) has been prepared by Technical Committee ISO/TC 30
"Measurement of fluid flow in closed conduits" in collaboration with CCMC.
This European Standard shall be given the status of a national standard, either by publication of an
identical text or by endorsement, at the latest by May 2023, and conflicting national standards shall be
withdrawn at the latest by May 2023.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN shall not be held responsible for identifying any or all such patent rights.
This document supersedes EN ISO 5167-6:2019.
Any feedback and questions on this document should be directed to the users’ national standards
body/national committee. A complete listing of these bodies can be found on the CEN website.
According to the CEN-CENELEC Internal Regulations, the national standards organizations of the
following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria,
Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland,
Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Republic of
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.