Medical electrical equipment - Part 2-46: Particular requirements for the basic safety and essential performance of operating tables

IEC 60601-2-46:2010 specifies safety requirements for operating tables, whether or not having electrical parts, including transporters, used for the transportation of the table top to or from the base or pedestal of an operating table with detachable table top. This second edition cancels and replaces the first edition published in 1998 and constitutes a technical revision. This edition of IEC 60601-2-46 was revised to align structurally with the 2005 edition of IEC 60601-1.

Medizinische elektrische Geräte - Teil 2-46: Besondere Festlegungen für die Sicherheit einschließlich der wesentlichen Leistungsmerkmale von Operationstischen

Appareils électromédicaux - Partie 2-46: Exigences particulières pour la sécurité de base et les performances essentielles des tables d'opération

La CEI 60601-2-46:2010 spécifie les exigences de sécurité applicables aux tables d'opération, que celles-ci comportent ou non des parties électriques, y compris les chariots de transfert, utilisés pour le transport du plateau vers ou depuis la base ou le socle d'une table d'opération à plateau mobile. Cette deuxième édition annule et remplace la première édition parue en 1998, et constitue une révision technique. La présente édition de la CEI 60601-2-46 a été mise à jour de façon à correspondre structurellement à l'édition 2005 de la CEI 60601-1.

Medicinska električna oprema - 2-46. del: Posebne zahteve za osnovno varnost in bistvene lastnosti operacijskih miz

Ta določeni standard opredeljuje varnostne zahteve za operacijske mize, ki imajo ali nimajo električnih delov, vključno s transporterji, ki se uporabljajo za prenos zgornje površine mize na bazo ali z nje ali podstavka operacijske mize z odstranljivo površino mize.

General Information

Status
Withdrawn
Publication Date
18-Aug-2011
Withdrawal Date
19-Jan-2014
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
15-Nov-2022
Completion Date
15-Nov-2022

Relations

Buy Standard

Standard
EN 60601-2-46:2011
English language
24 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 60601-2-46:2011
01-oktober-2011
0HGLFLQVNDHOHNWULþQDRSUHPDGHO3RVHEQH]DKWHYH]DRVQRYQRYDUQRVWLQ
ELVWYHQHODVWQRVWLRSHUDFLMVNLKPL]
Medical electrical equipment - Part 2-46: Particular requirements for the basic safety and
essential performance of operating tables
Appareils électromédicaux - Partie 2-46: Exigences particulières pour la sécurité de base
et les performances essentielles des tables d'opération
Ta slovenski standard je istoveten z: EN 60601-2-46:2011
ICS:
11.140 Oprema bolnišnic Hospital equipment
SIST EN 60601-2-46:2011 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 60601-2-46:2011

---------------------- Page: 2 ----------------------

SIST EN 60601-2-46:2011

EUROPEAN STANDARD
EN 60601-2-46

NORME EUROPÉENNE
August 2011
EUROPÄISCHE NORM

ICS 11.140 Supersedes EN 60601-2-46:1998


English version


Medical electrical equipment -
Part 2-46: Particular requirements for the basic safety and essential
performance of operating tables
(IEC 60601-2-46:2010)


Appareils électromédicaux -  Medizinische elektrische Geräte -
Partie 2-46: Exigences particulières pour Teil 2-46: Besondere Festlegungen für die
la sécurité de base et les performances Sicherheit einschließlich der wesentlichen
essentielles des tables d'opération Leistungsmerkmale von
(CEI 60601-2-46:2010) Operationstischen
(IEC 60601-2-46:2010)





This European Standard was approved by CENELEC on 2011-01-20. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Management Centre: Avenue Marnix 17, B - 1000 Brussels


© 2011 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 60601-2-46:2011 E

---------------------- Page: 3 ----------------------

SIST EN 60601-2-46:2011
EN 60601-2-46:2011 - 2 -
Foreword
The text of document 62D/870/FDIS, future edition 2 of IEC 60601-2-46, prepared by SC 62D,
Electromedical equipment, of IEC TC 62, Electrical equipment in medical practice, was submitted to the
IEC-CENELEC parallel vote and was approved by CENELEC as EN 60601-2-46 on 2011-01-20.
This European Standard supersedes EN 60601-2-46:1998.
EN 60601-2-46:1998 was revised to align structurally with EN 60601-1:2006.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent
rights.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2012-02-20
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2014-01-20
In this standard, the following print types are used:
– Requirements and definitions: roman type.
– Test specifications: italic type.
– Informative material appearing outside of tables, such as notes, examples and references: in smaller type. Normative text of
tables is also in a smaller type.
– TERMS DEFINED IN CLAUSE 3 OF THE GENERAL STANDARD, IN THIS PARTICULAR STANDARD
OR AS NOTED: SMALL CAPITALS.
In referring to the structure of this standard, the term
– “clause” means one of the seventeen numbered divisions within the table of contents, inclusive of all
subdivisions (e.g. Clause 7 includes subclauses 7.1, 7.2, etc.);
– “subclause” means a numbered subdivision of a clause (e.g. 7.1, 7.2 and 7.2.1 are all subclauses of
Clause 7).
References to clauses within this standard are preceded by the term “Clause” followed by the clause
number. References to subclauses wi
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.