Double-capped fluorescent lamps - Performance specifications

2016-01-19: If the vote is accepted update directive information in mother standard.
Common modifications intended for merge with PR=60123 & then transformed to homegrown AMD, as mother EN published as IEC identical

Zweiseitig gesockelte Leuchtstofflampen - Anforderungen an die Arbeitsweise

Lampes à fluorescence à deux culots - Prescriptions de performance

Fluorescenčne sijalke z dvema vznožkoma - Zahteve glede tehničnih lastnosti - Dopolnilo A11

General Information

Status
Published
Publication Date
10-May-2018
Current Stage
6060 - Document made available
Due Date
11-May-2018
Completion Date
11-May-2018

RELATIONS

Buy Standard

Amendment
EN 60081:1999/FprA6:2015/oprAA:2017
English language
9 pages
sale 10% off
Preview
sale 10% off
Preview

e-Library read for
1 day
Amendment
EN 60081:1999/A11:2018
English language
8 pages
sale 10% off
Preview
sale 10% off
Preview

e-Library read for
1 day

Standards Content (sample)

SLOVENSKI STANDARD
SIST EN 60081:1999/FprA6:2015/oprAA:2017
01-marec-2017
)OXRUHVFHQþQHVLMDONH]GYHPDY]QRåNRPD=DKWHYHJOHGHWHKQLþQLKODVWQRVWL
Double-capped fluorescent lamps - Performance specifications
Lampes à fluorescence à deux culots - Spécifications de performance
Ta slovenski standard je istoveten z: EN 60081:1998/FprA6:2015/prAA:2017
ICS:
29.140.30 )OXRUHVFHQþQHVLMDONH6LMDONH Fluorescent lamps.
Discharge lamps
SIST EN en
60081:1999/FprA6:2015/oprAA:2017

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
SIST EN 60081:1999/FprA6:2015/oprAA:2017
---------------------- Page: 2 ----------------------
SIST EN 60081:1999/FprA6:2015/oprAA:2017
EUROPEAN STANDARD DRAFT
EN 60081:1998/
NORME EUROPÉENNE
FprA6:2015
EUROPÄISCHE NORM
FprAA
January 2017
ICS 29.140.30
English Version
Double-capped fluorescent lamps - Performance specifications
Lampes à fluorescence à deux culots - Spécifications de To be completed
performance

This draft amendment FprAA, if approved, will modify the European Standard ; it is submitted to CENELEC members for enquiry.

Deadline for CENELEC: 2017-03-31.
It has been drawn up by CLC/TC 34A.

If this draft becomes an amendment, CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which

stipulate the conditions for giving this amendment the status of a national standard without any alteration.

This draft amendment was established by CENELEC in three official versions (English, French, German).

A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to

the CEN-CENELEC Management Centre has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,

Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,

Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden,

Switzerland, Turkey and the United Kingdom.

Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are aware and to

provide supporting documentation.

Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without notice and

shall not be referred to as a European Standard.
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels

© 2017 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.

Project: 61095 Ref. No. EN 60081:1998/FprA6:2015/prAA:2017 E
---------------------- Page: 3 ----------------------
SIST EN 60081:1999/FprA6:2015/oprAA:2017
EN 60081:1998/FprA6:2015/prAA:2017
1 European foreword

2 This draft amendment to the draft European Standard EN 60081:1998/FprA6:2015 was prepared by

3 CLC/TC 34A, Lamps. It contains common modifications to 34A/1835/CDV (future
4 IEC 60081:1997/A6:201X) and is submitted to the Enquiry.

5 If approved, this draft amendment will be merged together with EN 60081:1998/FprA6:2015 and both

6 drafts will be published as one single document, i.e. EN 60081:1998/A6:201X (based on

7 IEC 60081:1997/A6:201X, modified), with the implementation dates of this prAA.
8 The following dates are proposed:

– latest date by which the existence of this document has to be (doa) dor + 6 months

announced at national level

– latest date by which this document has to be implemented at (dop) dor + 12 months

national level by publication of an identical
national standard or by endorsement

– latest date by which the national standards conflicting with this (dow) dor + 36 months

document have to be withdrawn (to be confirmed or
modified when voting)

9 Clauses, subclauses, notes, tables, figures and annexes which are additional to those in

10 IEC 60081:1997/A6:201X are prefixed “Z”.

11 For the relationship with EU Directive(s) see informative Annexes ZZ, which is an integral part of this

12 document.

13 This standard provides test methods related to parameters as prescribed by EC Regulation 245/2009,

14 and EU Regulation 874/2012 while conformity assessment (sampling, conformity procedures as well

15 as limits) for market surveillance are specified in the text of the above Regulations.

---------------------- Page: 4 ----------------------
SIST EN 60081:1999/FprA6:2015/oprAA:2017
EN 60081:1998/FprA6:2015/prAA:2017
17 Text of prAA to draft EN 60081:1998/FprA6:2015
18 CONTENTS Add the following annexes:
19 Annex ZA (normative) Normative references to international publications with
20 their corresponding European publications
21 Annex ZZA (informative) Relationship between this European Standard and the
22 requirements of Commission Regulation (EC) No 245/2009
23 Annex ZZB (informative) Relationship between this European Standard and the
24 requirements of Commission Regulation (EU) No 874/2012
26 1.Z1 Add the following clause before clause 1.3
27 1.Z1 Overall statement

28 Where a Commission Regulation specifies limits for parameters these limits shall be

29 used instead of the limits specified in this standard.
30 1.4.Z1 After 1.4.11 add new definitions 1.4.Z1 up to 1.4..Z3:
31 1.4.Z1
32 efficacy

33 ‘luminous efficacy of a source’, ‘light source efficacy’ or ‘lamp efficacy’ (η )

source
34 quotient of the luminous flux emitted (Ф) by the power consumed by the source
35 (P ). η = Ф / P . Unit: lm/W.
source source source

36 Note 1 to entry: The power dissipated by auxiliary equipment such as ballasts is not included in the

37 power consumed by the source.
38 [SOURCE: Regulation 245/2009 Annex II, 1.a)]
39 1.4.Z2
40 lamp lumen maintenance factor (LLMF)

41 ratio of the luminous flux emitted by the lamp at a given time in its life to the initial

42 luminous flux
43 [SOURCE: Regulation 245/2009 Annex II, 1.b)]
44 1.4.Z3
45 lamp survival factor (LSF)

46 fraction of the total number of lamps which continue to operate at a given time under

47 defined conditions and switching frequency
48 [SOURCE: Regulation 245/2009 Annex II, 1.c)]
49 1.5.6 Before the text in 1.5.6, add a new header 1.5.6.Z1
50 1.5.6.Z1 General
51 After 1.5.6.Z1 add new 1.5.6.Z2 and 1.5.6.Z3
52 1.5.6.Z2 Chromaticity, colour temperature and colour rendering index

53 The chromaticity coordinates and correlated colour temperature of an individual lamp

54 shall be calculated according to CIE 15 from a measurement made under the
55 conditions of Annex B.

56 The colour rendering index of an individual lamp shall be calculated according to

57 CIE 13.3 from a measurement made under the conditions of Annex B.
58 1.5.6.Z3 Efficacy

59 The efficacy of an individual lamp shall be calculated from a measurement of luminous

60 flux and power according to the conditions of Annex B.
---------------------- Page: 5 ----------------------
SIST EN 60081:1999/FprA6:2015/oprAA:2017
EN 60081:1998/FprA6:2015/prAA:2017
61 1.5.7 Replace text of 1.5.7 with new 1.5.7.Z1 and 1.5.7. Z2
62 1.5.7.Z1 Lamp lumen maintenance factor

63 The lamp lumen maintenance factor of an individual lamp shall be calculated from

64 measurements of its luminous flux made at appropriate times according to the
65 conditions of Annex B. Lamp operation between these measurements shall be as
66 prescribed in Annex C.
67 1.5.7.Z2 Lamp survival

68 The survival of an individual lamp shall be determined by operating lamps under the

69 conditions prescribed in Annex C until the lamp fails to remain alight or delivers low

70 light output (in case of doubt, low light output refers to noticeably less than 50 % of

71 rated light output).
72 1.5.Z1 After 1.5.8 add new 1.5.Z1
73 1.5.Z1 Mercury content
74 The average mercury content shall be measured in accordance with the CV AAS

75 method as described in EN 62321-4. Lamp sample preparation shall be in accordance

76 with EN 62554.
77 B.1.3.Z.1 Before the text in B.1.3, add a new header B.1.3.Z1
78 B.1.3.Z1 General
79 After B.1.3.Z1 add new B.1.3.Z.2
80 B.1.3.Z.2 Measurement ballast

81 For lamps that are specified for operation on both a.c. mains frequencies and high

82 frequency, the information given on the data sheet for “HF measurement ballast

83 characteristics” defines the reference ballast for HF operation.
84 Bibliography After 1.7 Add
85 Bibliography
86 COMMISSION REGULATION (EC) No 245/2009 of 18 March 2009 implementing

87 Directive 2005/32/EC of the European Parliament and of the Council with regard to

88 ecodesign requirements for fluorescent lamps without integrated ballast, for high

89 in
...

SLOVENSKI STANDARD
SIST EN 60081:1999/A11:2018
01-julij-2018
)OXRUHVFHQþQHVLMDONH]GYHPDY]QRåNRPD=DKWHYHJOHGHWHKQLþQLKODVWQRVWL
'RSROQLOR$
Double-capped fluorescent lamps - Performance specifications
Lampes à fluorescence à deux culots - Spécifications de performance
Ta slovenski standard je istoveten z: EN 60081:1998/A11:2018
ICS:
29.140.30 )OXRUHVFHQþQHVLMDONH6LMDONH Fluorescent lamps.
Discharge lamps
SIST EN 60081:1999/A11:2018 en

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
SIST EN 60081:1999/A11:2018
---------------------- Page: 2 ----------------------
SIST EN 60081:1999/A11:2018
EUROPEAN STANDARD EN 60081:1998/A11
NORME EUROPÉENNE
EUROPÄISCHE NORM
May 2018
ICS 29.140.30
English Version
Double-capped fluorescent lamps - Performance specifications

Lampes à fluorescence à deux culots - Prescriptions de Zweiseitig gesockelte Leuchtstofflampen - Anforderungen

performance an die Arbeitsweise

This amendment A11 modifies the European Standard EN 60081:1998; it was approved by CENELEC on 2018-02-26. CENELEC members

are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this amendment the status of a

national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC

Management Centre or to any CENELEC member.

This amendment exists in three official versions (English, French, German). A version in any other language made by translation under the

responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as

the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,

Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,

Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden,

Switzerland, Turkey and the United Kingdom.
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels

© 2018 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.

Ref. No. EN 60081:1998/A11:2018 E
---------------------- Page: 3 ----------------------
SIST EN 60081:1999/A11:2018
EN 60081:1998/A11:2018 (E)
European foreword

This document (EN 60081:1998/A11:2018) has been prepared by CLC/TC 34 "Lamps and related

equipment".
The following dates are fixed:
– latest date by which this document has to be (dop) 2019-02-26
implemented at national level
by publication of an identical
national standard or by endorsement
– latest date by which the national standards conflicting (dow) 2021-02-26
with this document have to be withdrawn

Clauses, subclauses, notes, tables, figures and annexes which are additional to those in

IEC 60081:1997 and its amendments are prefixed “Z”.

This document has been prepared under a mandate given to CENELEC by the European Commission

and the European Free Trade Association, and supports essential requirements of EU Regulation(s).

For the relationship with EU Regulations see informative Annex ZZA and Annexe ZZB, which are

integral part of this document.

This standard provides test methods related to parameters as prescribed by EC Regulation 245/2009,

and EU Regulation 874/2012 while conformity assessment (sampling, conformity procedures as well

as limits) for market surveillance are specified in the text of the above Regulations.

---------------------- Page: 4 ----------------------
SIST EN 60081:1999/A11:2018
EN 60081:1998/A11:2018 (E)
CONTENTS Replacement of Annex ZA of EN 60081:1998:
Annex ZA (normative) Normative references to international publications with
their corresponding European publications
Add the following annexes:
Annex ZZA (informative) Relationship between this European Standard and the
requirements of Commission Regulation (EC) No 245/2009
Annex ZZB (informative) Relationship between this European Standard and the
requirements of Commission Regulation (EU) No 874/2012
1.Z1 Add the following clause before Subclause 1.3
1.Z1 Overall statement

Where a Commission Regulation specifies limits for parameters these limits shall be

used instead of the limits specified in this standard.
1.4.Z1 After 1.4.11 add new definitions 1.4.Z1 up to 1.4.Z3:
1.4.Z1
efficacy
‘luminous efficacy of a source’, ‘light source efficacy’ or ‘lamp efficacy’ (η )
source
quotient of the luminous flux emitted (Ф) by the power consumed by the source
(Psource). ηsource = Ф / Psource. Unit: lm/W

Note 1 to entry: The power dissipated by auxiliary equipment such as ballasts is not included in the

power consumed by the source.
[SOURCE: Regulation 245/2009 Annex II, 1.a)]
1.4.Z2
lamp lumen maintenance factor (LLMF)

ratio of the luminous flux emitted by the lamp at a given time in its life to the initial

luminous flux
[SOURCE: Regulation 245/2009 Annex II, 1.b)]
1.4.Z3
lamp survival factor (LSF)

fraction of the total number of lamps which continue to operate at a given time under

defined conditions and switching frequency
[SOURCE: Regulation 245/2009 Annex II, 1.c)]
1.5.6 Before the text in 1.5.6, add a new Subclause 1.5.6.Z1
1.5.6.Z1 General
After 1.5.6.Z1 add new Subclauses 1.5.6.Z2 and 1.5.6.Z3 as follows:
1.5.6.Z2 Chromaticity, correlated colour temperature and colour rendering
index

The chromaticity coordinates and correlated colour temperature of an individual lamp

shall be calculated according to CIE 15 from a measurement made under the
conditions of Annex B.

The colour rendering index of an individual lamp shall be calculated according to

CIE 13.3 from a measurement made under the conditions of Annex B.
---------------------- Page: 5 ----------------------
SIST EN 60081:1999/A11:2018
EN 60081:1998/A11:2018 (E)
1.5.6.Z3 Efficacy

The efficacy of an individual lamp shall be calculated from a measurement of luminous

flux and power according to the conditions of Annex B.

1.5.7 Replace text of 1.5.7 with new Subclauses 1.5.7.Z1 and 1.5.7.Z2 as follows:

1.5.7.Z1 Lamp lumen maintenance factor

The lamp lumen maintenance factor of an individual lamp shall be calculated from

measurements of its luminous flux made at appropriate times according to the
conditions of Annex B. Lamp operation between these measurements shall be as
prescribed in Annex C.
1.5.7.Z2 Lamp survival

The survival of an individual lamp shall be determined by operating lamps under the

conditions prescribed in Annex C until the lamp fails to remain alight or delivers low

light output (in case of doubt, low light output refers to noticeably less than 50 % of

rated light output).
1.5.Z1 After 1.5.8 add new Subclause 1.5.Z1
1.5.Z1 Mercury content
The average mercury content shall be measured in accordance with the CV AAS

method as described in EN 62321-4. Lamp sample preparation shall be in accordance

with EN 62554.
B.1.3.Z.1 Before the text in B.1.3, add a new Subclause B.1.3.Z1
B.1.3.Z1 General
After B.1.3.Z1 add new Subclause B.1.3.Z.2
B.1.3.Z.2 Measurement ballast

For lamps that are specified for operation on both a.c. mains frequencies and high

frequency, the information given on the data sheet for “HF measurement ballast
characteristics” defines the reference ballast for HF operation.
Bibliography After 1.7 Add:
Bibliography
COMMISSION REGULATION (EC) No 245/2009 of 18 March 2009 implementing

Directive 2005/32/EC of the European Parliament and of the Council with regard to

ecodesign requirements for fluorescent lamps without integrated ballast, for high

intensity discharge lamps, and for ballasts and luminaires able to operate such lamps,

and repealing Directive 2000/55/EC of the European Parliament and of the Council
COMMISSION REGULATION (EU) No 874/2012 of 12 July 2012 supplementing

Directive 2010/30/EU of the European Parliament and of the Council with regard to

energy la
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.