Information technology - Data centre facilities and infrastructures - Part 99-1: Recommended practices for energy management

This document is a compilation of recommended Practices for improving the energy management (i.e. reduction of energy consumption and/or increases in energy efficiency) of data centres. It is historically aligned with the EU Code of Conduct for Data Centre Energy Efficiency (CoC) scheme operated by the Directorate-General Joint Research Centre (DG JRC) of the European Commission (EC). It is recognized that the Practices included might not be universally applicable to all scales and business models of data centres or be undertaken by all parties involved in data centre operation, ownership or use.

Informationstechnik - Einrichtungen und Infrastrukturen von Rechenzentren - Teil 99-1: Empfohlene Praktiken für das Energiemanagement

Dieses Dokument ist eine Zusammenstellung empfohlener Praktiken zur Verbesserung des Energiemanagements (d. h. Reduzierung des Energieverbrauchs und/oder Steigerung der Energieeffizienz) von Rechenzentren. Es steht traditionell in Einklang mit dem von der Generaldirektion Gemeinsame Forschungsstelle (DG JRC) der Europäischen Kommission (EK) unterhaltenen System des EU Code of Conduct for Data Centre Energy Efficiency (CoC). Es sei ausdrücklich erwähnt, dass sich die aufgenommenen Praktiken nicht notwendigerweise in allgemeiner Weise auf alle Größen und Geschäftsmodelle von Rechenzentren anwenden lassen, oder dass sie möglicherweise nicht von allen am Betrieb, der Eigentümerschaft oder der Nutzung eines Rechenzentrums beteiligten Parteien ausgeführt werden.

Technologies de l'information - Installations et infrastructures de centres de traitement de données - Partie 99-1 : Pratiques recommandées relatives à la gestion énergétique

Informacijska tehnologija - Naprave in infrastruktura podatkovnega centra - 99-1. del: Priporočene prakse za upravljanje z energijo

Ta dokument je zbirka priporočenih praks za izboljšanje upravljanja z energijo (tj. zmanjšanje porabe energije in/ali povečanje energetske učinkovitosti) podatkovnih centrov. Zgodovinsko skladen je s kodeksom ravnanja EU za energetsko učinkovitost podatkovnih centrov (CoC), ki ga upravlja Generalni direktorat Skupno raziskovalno središče (DG JRC) Evropske komisije (EK).
Ugotovljeno je, da vključene prakse morda niso univerzalno veljavne za vse obsege in poslovne modele podatkovnih centrov ali jih izvajajo vse stranke, ki so vključene v delovanje, lastništvo ali uporabo podatkovnih centrov.

General Information

Status
Withdrawn
Publication Date
11-Jul-2019
Current Stage
9960 - Withdrawal effective - Withdrawal
Completion Date
13-Aug-2021

Relations

Buy Standard

Technical report
TP CLC/TR 50600-99-1:2019
English language
47 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST-TP CLC/TR 50600-99-1:2019
01-september-2019
Nadomešča:
SIST-TP CLC/TR 50600-99-1:2018
Informacijska tehnologija - Naprave in infrastruktura podatkovnega centra - 99-1.
del: Priporočene prakse za upravljanje z energijo
Information technology - Data centre facilities and infrastructures - Part 99-1:
Recommended practices for energy management
Informationstechnik - Einrichtungen und Infrastrukturen von Rechenzentren - Teil 99-1:
Empfohlene Praktiken für das Energiemanagement
Technologies de l'information - Installations et infrastructures de centres de traitement de
données - Partie 99-1 : Pratiques recommandées relatives à la gestion énergétique
Ta slovenski standard je istoveten z: CLC/TR 50600-99-1:2019
ICS:
27.015 Energijska učinkovitost. Energy efficiency. Energy
Ohranjanje energije na conservation in general
splošno
35.110 Omreževanje Networking
SIST-TP CLC/TR 50600-99-1:2019 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST-TP CLC/TR 50600-99-1:2019

---------------------- Page: 2 ----------------------

SIST-TP CLC/TR 50600-99-1:2019


TECHNICAL REPORT
CLC/TR 50600-99-1

RAPPORT TECHNIQUE

TECHNISCHER BERICHT
July 2019
ICS 35.020; 35.110; 35.160 Supersedes CLC/TR 50600-99-1:2018
English Version
Information technology - Data centre facilities and infrastructures
- Part 99-1: Recommended practices for energy management
Technologies de l'information - Installations et Informationstechnik - Einrichtungen und Infrastrukturen von
infrastructures de centres de traitement de données - Partie Rechenzentren - Teil 99-1: Empfohlene Praktiken für das
99-1 : Pratiques recommandées relatives à la gestion Energiemanagement
énergétique


This Technical Report was approved by CENELEC on 2019-07-01.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.


European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2019 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
 Ref. No. CLC/TR 50600-99-1:2019 E

---------------------- Page: 3 ----------------------

SIST-TP CLC/TR 50600-99-1:2019
CLC/TR 50600-99-1:2019 (E)
Contents Page
European foreword . 3
Introduction . 4
1 Scope . 7
2 Normative references . 7
3 Terms, definitions and abbreviations . 7
3.1 Terms and definitions . 7
3.2 Abbreviations . 10
4 Principles . 11
4.1 General . 11
4.2 Data centre utilization, management and planning . 12
4.3 Data centre ICT equipment and services . 12
4.4 Data centre cooling equipment . 13
4.5 Data centre power equipment . 14
4.6 Other data centre equipment . 14
4.7 Data centre building . 14
4.8 Data centre monitoring . 15
5 Expected Practices . 16
5.1 Existing data centres .
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.