Safety in electroheating installations - Part 4: Particular requirements for arc furnace installations

IEC 60519-4:2013 provides particular safety requirements for electric arc furnace installations and its operating and maintenance personnel. These safety provisions concern the protection of persons and the environment against dangers of electrical origin and also against certain dangers of non-electrical origin. This fourth edition cancels and replaces the third edition published in 2006. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - The structure has been amended and adjusted to IEC 60519-1:2010; - The classification (Clause 4) has been adapted to details with respect to secondary voltage in electric arc furnace installations; - All provisions have been redrafted and the text is more concise with respect to EAF; - Annexes AA, BB and CC have been restructured, with respect to details concerning high voltage designs and non-electrical issues, however to be aware of in those installations.

Sicherheit in Elektrowärmeanlagen - Teil 4: Besondere Bestimmungen für Lichtbogenofenanlagen

Sécurité dans les installations électrothermiques - Partie 4: Exigences particulières pour les installations de fours à arc

La CEI 60519-4:2013 fournit des exigences de sécurité particulières pour les installations de fours à arc électriques et pour le personnel de service et de maintenance. Ces dispositions de sécurité concernent la protection du personnel et de l'environnement contre les dangers d'origine électrique et certains dangers d'origine non électrique. Cette quatrième édition annule et remplace la troisième édition parue en 2006. Cette édition constitue une révision technique. Cette édition inclut les modifications techniques majeures suivantes par rapport à l'édition précédente: - La structure a été amendée et alignée sur celle de la CEI 60519-1:2010; - La classification (Article 4) a été adaptée aux détails par rapport à la tension secondaire d'un four à arc électrique; - Toutes les dispositions ont été reformulées et le texte relatif aux fours à arc électriques est plus concis; - Dans les Annexes AA, BB et CC, les parties relatives aux points suivants ont été restructurées: détails relatifs aux conceptions haute tension et aux problèmes non électriques, mais dont il faut tenir compte dans le cadre de ces installations.

Varnost pri električnih grelnih inštalacijah - 4. del: Posebne zahteve za inštalacije obločnih peči (IEC 60519-4:2013)

General Information

Status
Published
Publication Date
29-Aug-2013
Withdrawal Date
23-Jul-2016
Current Stage
6060 - Document made available - Publishing
Start Date
30-Aug-2013
Completion Date
30-Aug-2013

Relations

Buy Standard

Standard
EN 60519-4:2014
English language
27 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 60519-4:2014
01-februar-2014
1DGRPHãþD
SIST EN 60519-4:2007
9DUQRVWSULHOHNWULþQLKJUHOQLKLQãWDODFLMDKGHO3RVHEQH]DKWHYH]DLQãWDODFLMH
REORþQLKSHþL ,(&
Safety in electroheating installations - Part 4: Particular requirements for arc furnace
installations
Sicherheit in Elektrowärmeanlagen - Teil 4: Besondere Bestimmungen für
Lichtbogenofenanlagen
Sécurité dans les installations électrothermiques - Partie 4: Exigences particulières pour
les installations de fours à arc
Ta slovenski standard je istoveten z: EN 60519-4:2013
ICS:
25.180.10 (OHNWULþQHSHþL Electric furnaces
SIST EN 60519-4:2014 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 60519-4:2014

---------------------- Page: 2 ----------------------

SIST EN 60519-4:2014

EUROPEAN STANDARD
EN 60519-4

NORME EUROPÉENNE
August 2013
EUROPÄISCHE NORM

ICS 25.180.10 Supersedes EN 60519-4:2006


English version


Safety in electroheating installations -
Part 4: Particular requirements for arc furnace installations
(IEC 60519-4:2013)


Sécurité dans les installations Sicherheit in Elektrowärmeanlagen -
électrothermiques - Teil 4: Besondere Bestimmungen für
Partie 4: Exigences particulières pour les Lichtbogenofenanlagen
installations de fours à arc (IEC 60519-4:2013)
(CEI 60519-4:2013)




This European Standard was approved by CENELEC on 2013-07-24. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the CEN-CENELEC Management Centre or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the CEN-CENELEC Management Centre has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany,
Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland,
Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

CEN-CENELEC Management Centre: Avenue Marnix 17, B - 1000 Brussels


© 2013 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 60519-4:2013 E

---------------------- Page: 3 ----------------------

SIST EN 60519-4:2014
EN 60519-4:2013 - 2 -
Foreword
The text of document 27/904/FDIS, future edition 4 of IEC 60519-4, prepared by IEC/TC 27 "Industrial
electroheating and electromagnetic processing" was submitted to the IEC-CENELEC parallel vote and
approved by CENELEC as EN 60519-4:2013.
The following dates are fixed:
(dop) 2014-04-24
• latest date by which the document has
to be implemented at national level by
publication of an identical national
standard or by endorsement
(dow) 2016-07-24
• latest date by which the national
standards conflicting with the
document have to be withdrawn

The clauses of parts of the EN 60519 series (hereinafter called Particular requirements) supplement or
modify the corresponding clauses of EN 60519-1:2011 (General requirements hereinafter called
Part 1).

This part of EN 60519 is to be read in conjunction with Part 1. It supplements or modifies the
corresponding clauses of Part 1. Where the text indicates an "addition" to or a "replacement" of the
relevant provision of Part 1, these changes are made to the relevant text of Part 1. Where no change
is necessary, the words "This clause of Part 1 is applicable" are used. When a particular subclause of
Part 1 is not mentioned in this part, that subclause applies as far as is reasonable.

Additional specific provisions to those in Part 1, given as individual clauses or subclauses, are
numbered starting from 101.

NOTE The following numbering system is used:
– subclauses, tables and figures that are numbered starting from 101 are additional to those in Part 1;
– unless notes are in a new subclause or involve notes in Part 1, they are numbered starting from 101, including those in a
replaced clause or subclause;
– additional annexes are lettered AA, BB, etc.

This document supersedes EN 60519-4:2006.
EN 60519-4:2013 includes the followi
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.