General practices for the repair of water-leakage cracks in concrete structures

This document provides a guideline for the selection of a proper grout material to repair water leakage through cracks and other deformities in concrete structures. The factors relevant to the quality control of maintenance and repair of water-leakage cracks are as the following; a) conditions of water-leakage cracks; b) performance requirements for repair materials; c) different types of repair materials (grouts); d) procedures followed to select the appropriate repair materials; e) execution of different types of repair methods; f) performance assessments of applied materials and methods; g) data collection. This document does not include any details on the repair of dry cracks and the causes of cracks. The details on dry crack repair are covered in ISO 16311-4. A flow chart for maintenance of water-leakage cracks is shown in Figure 1.

Pratiques générales pour la répartition des fissures dues à l'eau dans les structures en béton

General Information

Status
Published
Publication Date
19-Mar-2020
Current Stage
6060 - International Standard published
Start Date
20-Mar-2020
Completion Date
20-Mar-2020
Ref Project

Relations

Buy Standard

Technical report
ISO/TR 16475:2020 - General practices for the repair of water-leakage cracks in concrete structures
English language
15 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

TECHNICAL ISO/TR
REPORT 16475
Second edition
2020-03
General practices for the repair of
water-leakage cracks in concrete
structures
Pratiques générales pour la répartition des fissures dues à l'eau dans
les structures en béton
Reference number
ISO/TR 16475:2020(E)
©
ISO 2020

---------------------- Page: 1 ----------------------
ISO/TR 16475:2020(E)

COPYRIGHT PROTECTED DOCUMENT
© ISO 2020
All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may
be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting
on the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address
below or ISO’s member body in the country of the requester.
ISO copyright office
CP 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Fax: +41 22 749 09 47
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland
ii © ISO 2020 – All rights reserved

---------------------- Page: 2 ----------------------
ISO/TR 16475:2020(E)

Contents Page
Foreword .iv
Introduction .v
1 Scope . 1
2 Normative references . 2
3 Terms and definitions . 2
4 Conditions of water-leakage cracks . 2
4.1 Types of water-leakage cracks . 2
4.2 Environmental degradation factors that cause water-leakage cracks . 3
4.2.1 General. 3
4.2.2 Chemical conditions . 4
4.2.3 Physical (mechanical) conditions. 4
5 Expected performance for repair materials . 5
5.1 General . 5
5.2 Expected performance for chemical conditions . 5
5.2.1 Thermal stability. 5
5.2.2 Chemical resistance . 5
5.3 Expected performance for physical (mechanical) conditions . 5
5.3.1 Water (wash out) resistance . 5
5.3.2 Adhesion on wet substrate surface . 5
5.3.3 Watertightness . 6
5.3.4 Response to the substrate movement . 6
6 Grout materials for repair . 6
6.1 General . 6
6.2 Acrylic grouts (water-based acrylic gel grout) . 7
6.3 Cementitious grouts (water-based mixture of cement grout) . 7
6.4 Epoxy resin grout . 8
6.5 Polyurethane grouts . 8
6.6 Synthetic rubber polymer gel grout. 8
6.7 Other materials . 8
7 Appropriate repair material selection procedure . 9
7.1 Selection process of repair materials (injection grouts) . 9
7.2 Test for performance requirements. 9
7.2.1 General. 9
7.2.2 Test for thermal stability .10
7.2.3 Test for chemical resistance .10
7.2.4 Test for water flow (wash out) resistance .10
7.2.5 Test for adhesion on wet substrate surface .10
7.2.6 Test for watertightness .11
7.2.7 Test for response to the substrate movement .11
8 Execution of different types of repair methods .11
8.1 General .11
8.2 Grouting injection methods .11
8.3 Injection method for reforming a waterproofing layer .12
9 Performance assessments of repaired structures .13
9.1 Inspection of repairs .13
9.2 Evaluation of repairs .13
10 Data collection (reference material) .14
Bibliography .15
© ISO 2020 – All rights reserved iii

---------------------- Page: 3 ----------------------
ISO/TR 16475:2020(E)

Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular, the different approval criteria needed for the
different types of ISO documents should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2 (see www .iso .org/ directives).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of
any patent rights identified during the development of the document will be in the Introduction and/or
on the ISO list of patent declarations received (see www .iso .org/ patents).
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation of the voluntary nature of standards, the meaning of ISO specific terms and
expressions related to conformity assessment, as well as information about ISO's adherence to the
World Trade Organization (WTO) principles in the Technical Barriers to Trade (TBT) see www .iso .org/
iso/ foreword .html.
This document was prepared by Technical Committee ISO/TC 71, Concrete, reinforced concrete and pre-
stressed concrete, Subcommittee SC 7, Maintenance and repair of concrete structures.
Any feedback or questions on this document should be directed to the user’s national standards body. A
complete listing of these bodies can be found at www .iso .org/ members .html.
iv © ISO 2020 – All rights reserved

---------------------- Page: 4 ----------------------
ISO/TR 16475:2020(E)

Introduction
This document is intended to provide an informative outline of practice for the repair of water-leakage
cracks of concrete structures. There are two types of cracks that can form in a concrete structure; dry
cracks and water-leakage (wet) cracks. Cracks normally form when the structural element is subject
to phenomena such as dry-shrinkage and formation of joints. In the typical above grade sections of the
concrete structure, dry cracks are more easily controlled and repaired with a well-defined maintenance
method. When cracks are formed by the effect of hydrostatic pressure and the interface of the crack
is subject to constant wetness, these cracks are designated as water-leakage cracks. The ingress of
water through cracks often leads to increase of humidity in the building interior and this can result
in a drastically accelerated degradation of durability for the concrete structure. In extreme cases, the
presence of water can generate harmful effects that cause health problems to the users, rendering the
building completely uninhabitable.
In the current state, it is difficult to secure a proper repair method of water-leakage cracks because of
insufficient knowledge and understanding of the degradation factors (i.e. environmental conditions,
the influences of various human activities, etc.), at an institutional level. There are already a number
of repair techniques and application methods that are commonly used in application, but the required
conditions for properly repairing and sealing the water-leakage cracks have often been proven to be
difficult. Even in some cases where the repair procedures have been followed through properly with
skilled workmanship, the performance level of the repair method may be insufficient and lead to
reopening of the leakage crack. This can in turn lead to increase in maintenance and labour costs and
decrease in the property value of the building structures.
Past records of remedial actions for cracks and damage in concrete structures have shown varying
degrees of results; some have shown failure, some have had minor success and, in some cases,
an adequate solution was implemented. However, the cases of successful repair methods cannot
serve as a universal model for all cases of cracks and leakage due to the diversity of environmental
degradation factors existing in the construction field. In this regard, a standardized practice for
selecting appropriate leakage repair materials and methods in construction sites can be used. It is
highly anticipated that a newly proposed awareness and understanding of these issues will prevent
further unnecessary increase in maintenance costs, expenditures and results in improved durability
performance of concrete structures.
© ISO 2020 – All rights reserved v

---------------------- Page: 5 ----------------------
TECHNICAL REPORT ISO/TR 16475:2020(E)
General practices for the repair of water-leakage cracks in
concrete structures
1 Scope
This document provides a guideline for the selection of a proper grout material to repair water leakage
through cracks and other deformities in concrete structures. The factors relevant to the quality control
of maintenance and repair of water-leakage cracks are as the following;
a) conditions of water-leakage cracks;
b) performance requirements for repair materials;
c) different types of repair materials (grouts);
d) procedures followed to select the appropriate repair materials;
e) execution of different types of repair methods;
f) performance assessments of applied materials and methods;
g) data collection.
This document does not include any details on the repair of dry cracks and the causes of cracks. The
details on dry crack repair are covered in ISO 16311-4.
A flow chart for maintenance of water-leakage cracks is shown in Figure 1.
Figure 1 — Flow chart for maintenance of water-leakage chart
© ISO 2020 – All rights reserved 1

---------------------- Page: 6 ----------------------
ISO/TR 16475:2020(E)

2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
ISO 16311-2, Maintenance and repair of concrete structures — Part 2: Assessment of existing concrete
structures
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 16311-2 and the following apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https:// www .iso .org/ obp
— IEC Electropedia: available at http:// www .electropedia .org/
3.1
water-leakage crack
gap or split in a concrete substrate accompanied by intermittent or continuous contact of water present
across the interface of the gap/split surface
3.2
leakage
amount or flowing state of liquid(water) that is entering into the interior of the concrete structure by
means of a crack, hole, joint or other structural fault
3.3
thermal stability
ability to withstand long time exposure to elevated temperature
[SOURCE: IEC 60050:2010, 212-12-32]
3.4
washout resistance
property of the water-leakage crack (3.1) repair material related to the ability to withstand quantitative
and qualitative loss of materials produced by the pressure and flow velocity of water
3.5
watertightness
repair material’s waterproofing performance in consideration to its impermeability, adhesion strength
to the concrete substrate surface and cohesive strength, while being subject to the influence of
hydrostatic pressure
4 Conditions of water-leakage cracks
4.1 Types of water-leakage cracks
Leakage type and degree, and crack size (width) classification can be difficult as there are variances
in leakage crack control methods with different repair material and methods. Leakage types can be
classified as damp, seepage and flow, but specific amount of water leakage for the corresponding
leakage types also varies. Optimal grout injection method and material selection through evaluation
and testing can be applied for the respective classification of cracks (fine, medium and large cracks) in
relation to different leakage types and degrees (damp, seepage and flow). In this document, a leakage
type and degree classification system from ICRI 340.1-2006 is provided. The reference also provides
an information on the possible crack size classification (crack width) that corresponds to the leakage
types and degrees. This information is provided in Table 1.
2 © ISO 2020 – All rights reserved

---------------------- Page: 7 ----------------------
ISO/TR 16475:2020(E)

Table 1 — Classification of cracks in relation to repair of water-leakage (example)
Type of crack Patterns of leakage
Non-moving crack —
Damp surface
Light seepage
<1 l/min (<1/4 gal/min)
Medium seepage
Fine cracks
>1 l/min to 5 l/min (>1/4 gal/min to 1 1/4 gal/min)
≤2 mm (≤1/13 in)
Heavy seepage
Medium cracks
>5 l/min to 10 l/min (>1 1/4 gal/min to 2 1/2 gal/min)
>2 mm to 6 mm (>1/13 in to 1/4 in)
Light flow
Large cracks
>10 l/min to 15 l/min (>2 1/2 gal/min to 4 gal/min)
>6 mm to 20 mm (>1/4 in to 10/13 in)
Medium flow
>15 l/mm to 25 l/min (>4 gal/min to 6 1/2 gal/min)
Heavy flow
>25 l/min (>6 1/2 gal/min)
NOTE 1  Each and every crack width in the left column corresponds to the leakage amount conditions specified in the right-
side column.
NOTE 2  Leakage types and degrees, and crack sizes (width) can differ in national standards.
4.2 Environmental degradation factors that cause water-leakage cracks
4.2.1 General
Unlike dry cracks, water-leakage cracks are often caused by exposure to certain environmental-related
(chemical and physical) degradation factors that are caused by nature. These factors are: temperature
and humidity in the atmosphere and concrete surface, water pressure, flow velocity, chemical reactions
of the water and various forms of mechanical loads (e.g. vibration caused by passing vehicles). When in
the presence of one or more these environmental factors in a concrete structure, structural degradation
accelerates and negatively affects performance level of repair (see Figure 2).
© ISO 2020 – All rights reserved 3

---------------------- Page: 8 ----------------------
ISO/TR 16475:2020(E)

Figure 2 — Environmental conditions and required performance for water-leakage crack repairs
Water-leakage cracks are constantly subject to a variety of environmental degradation factors. In order
to establish a proper response to degradation factors that exist in the surrounding environment, it is
important to select the appropriate repair materials and methods.
Based on the types of environmental factors found in the concrete structure surroundings, the types
of possible defects such as material adhesion failure, waterproofing layer delamination or material
cracking can be estimated. Potential sources of degradation can be clearly identified and repair
materials with the required performance level that can respond to these degradation factors is selected
accordingly. Finally, the installation process can be observed and evaluated to determine that the repair
material can maintain a long-term quality performance while subject to constant exposure to the given
environmental degradation condition.
Figure 2 categorizes the environmental degradation factors into the relevant categories and outlines
the required material properties.
4.2.2 Chemical conditions
Chemical factors that affect the performance of repair materials in water-leakage cracks include
temperature changes and ambient conditions of the water-leakage cracks and the chemical composition
of the water (e.g. underground water, salt water, sewage water and acid rain). These factors affect
thermal stability, resistance to chemical attack, watertightness and the adhesion performance of repair
material on the concrete substrate surface.
4.2.3 Physical (mechanical) conditions
The physical (mechanical) factors that affect the performance of repair materials in water-leakage
cracks include the movement of the concrete substrate joints or cracks, shrinkage and expansion of
concrete due to temperature change, structural settlement, surrounding loads caused by passing of
vehicles and hydrostatic pressure.
4 © ISO 2020 – All rights reserved

---------------------- Page: 9 ----------------------
ISO/TR 16475:2020(E)

These factors affect the repair material adhesion on the concrete substrate surface, the watertightness
and the elongation of the repair materials.
5 Expected performance for repair materials
5.1 General
Materials used for repairing water-leakage cracks prevent water leakage by maintaining an adequate
response performance to the environmental conditions. To this end, a thorough understanding of the
expected performance of the repair materials can assist in selecting the appropriate material. The
expected performance can be divided into the categories outlined in 5.2 and 5.3.
5.2 Expected performance for chemical conditions
5.2.1 Thermal stability
Under a high degree of temperature change, the concrete substrate is subject to direct or indirect
effects of dry-shrinkage, structural movement and joint movement of the concrete substrate. Repair
materials can seem to maintain a cohesive bond when installed in concrete substrate surface based on
the results of empirical data of standard testing. However, it is advised that a qualitative delamination
resistance property testing be conducted to conclusively ensure that the selected water leakage repair
material can maintain an integral structure while subject to a variety of degradation factors.
5.2.2 Chemical resistance
Concrete structures are constructed under various chemical environmental conditions. Waterproofing
membranes are often exposed to contact to water or soil in underground structures. In cases where
the concrete structures are located near industrial areas or seashores, corrosion caused by chemical
substances (e.g. acid, alkali, salt water or calcium hydroxide and carbon dioxide) can occur more
frequently. In addition, chemical corrosion decreases the performance of the injected repair materials
by hindering normal chemical reactions caused by mixing different admixtures.
5.3 Expected performance for physical (mechanical) conditions
5.3.1 Water (wash out) resistance
Water-leakage cracks are subject to intermittent or continuous hydrostatic pressure. For non-grout
injection type repair materials that require curing period (liquid/semiliquid state) and have low
concentration gradient, the material can be discharged or washed out of the crack due to water flow
before the material reaction can fully form a waterproof layer. For some types of materials, this can
lead to environmental pollution. For grout type and cementitious repair materials, long-term exposure
to water flow can also lead to material erosion, with some materials remaining whole inside the crack
longer than others.
Manufacturers and architects/engineers can be consulted to find out all the information pertaining to
the specific properties and limitations of the repair material when concerning the washout resistance
performance of the repair materials.
5.3.2 Adhesion on wet substrate surface
In most cases, repair materials are injected into water-leakage cracks while moisture is still present
at the interface of the crack surface. By conducting proper surface treatment prior to injection, elected
repair material can secure a sufficiently strong adhesive bond to surfaces with moisture. Necessary
information on the injection amount and speed is to be obtained from manufacturer instructions.
An evenly distributed application of the repair material can ensure a more durable and stable
waterproofing membrane structure within the water-leakage crack.
© ISO 2020 – All rights reserved 5

---------------------- Page: 10 ----------------------
ISO/TR 16475:2020(E)

Manufacturers and architects/engineers can be consulted to find out all the information pertaining
to the specific properties and limitations of the repair material when concerning the adhesion
performance on wet substrate surface of the repair materials.
5.3.3 Watertightness
Watertightness refers to the integral waterproofing performance of the repair material system
installed in the concrete structure. Under the parameters of this document, watertightness is defined
with the following criteria:
1) impermeability of the repair material to hydrostatic pressure;
2) the adhesive bond of the repair material to the concrete substrate surface to prevent ingress of
water through leakage paths formed in the interface of material adhesion failure; and
3) the cohesive bond of the repair material to prevent delamination or breakage due to structural
movement.
When repairing water-leakage cracks, repair materials with the correct performance properties
can satisfy the required watertight performance standard. The installation procedure is conducted
correctly in accordance to manufacturer instructions to ensure that the repair material can secure
a proper adhesion onto the wet concrete surface. Lastly, it is to select repair materials that will not
delaminate or permanently deform under hydrostatic pressure and repeated structural movement.
5.3.4 Response to the substrate movement
Water-leakage cracks or construction joints are subject to constant micro movements caused by drying
shrinkage and expansion due to changes in the capillary water amount, temperature, hydrostatic
pressure, structural settlement and various types of loads from surrounding sources. Repair material
membranes bonded onto the interface of the water-leakage crack surface are subject to strain which
can results in cohesive and/or adhesive failure. Regarding substrate movement resistance performance
of repair materials, it is important to ensure that the selected injected repair material has sufficient
elasticity and substrate movement response performance.
Manufacturers and architects/engineers can be consulted to find out all the information pertaining
to the specific properties and limitations of the repair material when concerning the performance
response to the substrate movement of the repair materials.
6 Grout materials for repair
6.1 General
Injection type grout repair materials are commonly used in today’s market for repair water-leakage
cracks. Among these, some of the most common types include acrylics grout, water-based cementitious
grout, hydrophilic epoxy resin grout, polyurethane foam grout, synthetic rubberized gel grout and
others. For most repair material products, details on the ingredient components, optimal mixture
ratios and empirical data on physical properties are available in manufacturer guidelines.
However, in construction sites there are numerous factors that can differ from manufacturer directions
for proper installation. The ambient condition and duration of storage, mixture time and degree of
different components, quality of workmanship and environmental conditions are all factors that
can influence the quality of the repair work. In cases where conditions outlined in the manufacturer
guidelines cannot be met, repair materials can be designed to satisfy certain basic requirements to
compensate for the possibilities of early failure and re-opening of cracks due to improper installation.
There have been numerous attempt
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.