INTERNATIONAL ISO
STANDARD 2394
Second edition
1998-06-01
General principles on reliability for structures
Principes généraux de la fiabilité des constructions
A
Reference number
ISO 2394:1998(E)

---------------------- Page: 1 ----------------------
ISO 2394:1998(E)
Contents Page
1 Scope. 1
2 Definitions . 1
3 Symbols. 5
4 Requirements and concepts . 6
4.1  Fundamental requirements. 6
4.2  Reliability differentiation of structures. 7
4.3  Structural design. 8
4.4  Compliance. 9
4.5  Durability and maintenance . 10
5 Principles of limit states design. 11
5.1  Limit states . 11
5.2  Design . 12
6 Basic variables. 13
6.1  General. 13
6.2  Actions. 14
6.3  Environmental influences . 15
6.4  Properties of materials . 16
6.5  Geometrical quantities . 16
7 Models . 16
7.1  General. 16
7.2  Types of models. 17
7.3  Model uncertainties . 20
7.4  Design based on experimental models . 21
©  ISO 1998
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced
or utilized in any form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from the publisher.
International Organization for Standardization
Case postale 56 • CH-1211 Genève 20 • Switzerland
Internet central@iso.ch
X.400 c=ch; a=400net; p=iso; o=isocs; s=central
Printed in Switzerland
ii

---------------------- Page: 2 ----------------------
©
ISO ISO 2394:1998(E)
8 Principles of probability-based design . 21
8.1  General. 21
8.2  Systems reliability versus element reliability . 22
8.3  Specified degrees of required reliability . 23
8.4  Calculation of failure probabilities. 23
8.5  Implementation of probability-based design. 24
9 Partial factors format . 24
9.1  Design conditions and design values . 24
9.2  Representative values of actions. 26
9.3  Characteristic values of properties of materials
including soils . 26
9.4  Characteristic values of geometrical quantities. 27
9.5  Load cases and load combinations. 27
9.6  Action effects and resistances. 27
9.7  Verification for fatigue. 28
9.8  Calibration . 28
10 Assessment of existing structures . 28
10.1  Relevant cases. 28
10.2  Principles of assessment. 28
10.3  Basic variables. 29
10.4  Investigation. 29
10.5  Assessment in the case of damage. 30
Annex A: Quality management and quality assurance. 31
Annex B: Examples of permanent, variable and accidental actions 35
Annex C: Models for fatigue . 37
Annex D: Design based on experimental models. 40
Annex E: Principles of reliability-based design. 50
Annex F: Combination of actions and estimation of action values 62
Annex G: Example of a method of combination of actions. 71
Annex H: Index of definitions . 73
iii

---------------------- Page: 3 ----------------------
©
ISO 2394:1998(E) ISO
Foreword
ISO (the International Organization for Standardization) is a worldwide
federation of national standards bodies (ISO member bodies). The work of
preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which
a technical committee has been established has the right to be represented
on that committee. International organizations, governmental and non-
governmental, in liaison with ISO, also take part in the work. ISO
collaborates closely with the International Electrotechnical Commission
(IEC) on all matters of electrotechnical standardization.
Draft International Standards adopted by the technical committees are
circulated to the member bodies for voting. Publication as an International
Standard requires approval by at least 75 % of the member bodies casting
a vote.
International Standard ISO 2394 was prepared by Technical Committee
ISO/TC 98, Bases for design of structures, Subcommittee SC 2, Reliability
of structures.
This second edition cancels and replaces the first edition (ISO 2394:1986),
which has been technically revised.
Annexes A to F of this International Standard are for information only.
iv

---------------------- Page: 4 ----------------------
©
ISO ISO 2394:1998(E)
Introduction
This International Standard constitutes a common basis for defining design
rules relevant to the construction and use of the wide majority of buildings
and civil engineering works, whatever the nature or combination of the
materials used. However, their application to each type of material
(concrete, steel, timber, masonry, etc.) will require specific adaptation to
ensure a degree of reliability which, as far as possible, is consistent with
the objectives of the code drafting committees for each material.
This International Standard is intended to serve as a basis for those
committees responsible for the task of preparing national standards or
codes of practice in accordance with the technical and economic conditions
in a particular country, and which take into account the nature, type and
conditions of use of the structure and the properties of the materials during
its design working life. It will also provide a common basis for other
International Standards (e.g. ENV 1991-1 EC1) dealing with load-bearing
structures. Thus it has a conceptual character and it is of a fairly general
nature.
It is important to recognize that structural reliability is an overall concept
comprising models for describing actions, design rules, reliability elements,
structural response and resistance, workmanship, quality control
procedures and national requirements, all of which are mutually dependent.
The modification of one factor in isolation could therefore disturb the
balance of reliability inherent in the overall concept.
It is therefore important that the modification of any one factor should be
accompanied by a study of the implications relating to the overall reliability
concept.
v

---------------------- Page: 5 ----------------------
©
INTERNATIONAL STANDARD  ISO ISO 2394:1998(E)
General principles on reliability for structures
1  Scope
This International Standard specifies general principles for the verification of the reliability of structures subjected to
known or foreseeable types of action. Reliability is considered in relation to the performance of the structure
throughout its design working life.
The general principles are applicable to the design of complete structures (buildings, bridges, industrial structures,
etc.), the structural elements making up the structure and the foundations.
This International Standard is also applicable to the successive stages in construction, namely the fabrication of
structural elements, the transport and handling of the structural elements, their erection and all work on site, as well
as the use of the structure during its design working life, including maintenance and repair.
To allow for the differences in design practice between different countries, the national standards or codes of
practice may be simpler or more detailed in comparison with this International Standard.
Generally the principles are also applicable to the structural appraisal of existing constructions or assessing
changes of use. However in some respects this is associated with special aspects of the basic variables and
calculation models. Such aspects are considered in clause 10.
NOTE —  When this International Standard is applied in a particular country for the development of its standards, it is
admissible not to use those clauses which are not in accordance with the regulations of that particular country.
2  Definitions
For the purposes of this International Standard, the following definitions apply.
NOTE —  An alphabetical index of the definitions is given in annex H.
2.1  General terms
2.1.1  structure: Organized combination of connected parts designed to provide some measure of rigidity.
2.1.2  structural element: Physically distinguishable part of a structure.
EXAMPLES: Column, beam, plate.
2.1.3  structural system: Load-bearing elements of a building or civil engineering works and the way in which
these elements function together.
2.1.4  compliance: Fulfilment of specified requirements.
1

---------------------- Page: 6 ----------------------
©
ISO
ISO 2394:1998(E)
2.1.5  life cycle: Total period of time during which the planning, execution and use of a construction works takes
place. The life cycle begins with identification of needs and ends with demolition.
2.2  Terms relating to design in general
2.2.1  design situation: Set of physical conditions representing a certain time interval for which the design
demonstrates that relevant limit states are not exceeded.
2.2.2  persistent situation: Normal condition of use for the structure, generally related to its design working life.
NOTE —  "Normal use" includes possible extreme loading conditions due to wind, snow, imposed loads, earthquakes in areas of
high seismicity, etc.
2.2.3  transient situation: Provisional condition of use or exposure for the structure.
EXAMPLE: During its construction or repair, which represents a time period much shorter than the design working life.
2.2.4  accidental situation: Exceptional condition of use or exposure for the structure.
EXAMPLES: Flood, land slip, fire, explosion, impact or local failure, which represent in most cases a very short time period
(apart from situations where a local failure may remain undetected during a longer period).
2.2.5  serviceability: Ability of a structure or structural element to perform adequately for normal use under all
expected actions.
2.2.6  failure: Insufficient load-bearing capacity or inadequate serviceability of a structure or structural element.
2.2.7  reliability: Ability of a structure or structural element to fulfil the specified requirements, including the working
life, for which it has been designed.
2.2.8  reference period: A chosen period of time which is used as a basis for assessing values of variable actions,
time-dependent material properties, etc.
2.2.9  limit state: A state beyond which the structure no longer satisfies the design performance requirements.
NOTE —  Limit states separate desired states (no failure) from undesired states (failure).
2.2.10  ultimate limit state: A state associated with collapse, or with other similar forms of structural failure.
NOTE —  This generally corresponds to the maximum load-carrying resistance of a structure or structural element but in some
cases to the maximum applicable strain or deformation.
2.2.11  serviceability limit state: A state which corresponds to conditions beyond which specified service
requirements for a structure or structural element are no longer met.
2.2.12  irreversible limit state: A limit state which will remain permanently exceeded when the actions which
caused the excess are removed.
2.2.13  reversible limit state: A limit state which will not be exceeded when the actions which caused the excess
are removed.
2.2.14  structural integrity (structural robustness) : Ability of a structure not to be damaged by events like fire,
explosions, impact or consequences of human errors, to an extent disproportionate to the original cause.
2.2.15  design working life: Assumed period for which a structure or a structural element is to be used for its
intended purpose without major repair being necessary.
2.2.16  maintenance: Total set of activities performed during the design working life of a structure to enable it to
fulfil the requirements for reliability.
2

---------------------- Page: 7 ----------------------
©
ISO
ISO 2394:1998(E)
2.2.17  reliability class of structures: Class of structures or structural elements for which a particular specified
degree of reliability is required.
2.2.18  basic variable: Part of a specified set of variables representing physical quantities which characterize
actions and environmental influences, material properties including soil properties, and geometrical quantities.
2.2.19  primary basic variable: Variable whose value is of primary importance to the design results.
2.2.20  limit state function: A function g of the basic variables, which characterizes a limit state when
g(X , X ,., X ) = 0: g > 0 identifies with the desired state and g < 0 with the undesired state.
1 2 n
-1 -1
2.2.21  reliability index, b: A substitute for the failure probability p , defined by b = - F (p ), where F is the
f f
inverse standardized normal distribution.
2.2.22  partial factors format: Calculation format in which allowance is made for the uncertainties and variabilities
assigned to the basic variables by means of representative values, partial factors and, if relevant, additive
quantities.
2.2.23  reliability element: Numerical quantity used in the partial factors format, by which the specified degree of
reliability is assumed to be reached.
2.2.24  element reliability: Reliability of a single structural element which has one single dominating failure mode.
2.2.25  system reliability: Reliability of a structural element which has more than one relevant failure mode or the
reliability of a system of more than one relevant structural element.
2.2.26  model: Simplified mathematical description or experimental set-up simulating actions, material properties,
the behaviour of a structure, etc.
NOTE —  Models should generally take account of decisive factors and neglect the less important ones.
2.2.27  model uncertainty: Related to the accuracy of models, physical or statistical.
NOTE —  Further information is given in annexes D and E.
2.2.28  statistical uncertainty: Uncertainty related to the accuracy of the distribution and estimation of
parameters.
2.2.29  assessment: Total set of activities performed in order to find out if the reliability of a structure is acceptable
or not.
2.3  Terms relating to actions, action effects and environmental influences
2.3.1  action
1) An assembly of concentrated or distributed mechanical forces acting on a structure (direct actions).
2) The cause of deformations imposed on the structure or constrained in it (indirect action).
2.3.2  permanent action:
1) Action which is likely to act continuously throughout a given reference period and for which variations in
magnitude with time are small compared with the mean value.
2) Action whose variation is only in one sense and can lead to some limiting value.
2.3.3  variable action: Action for which the variation in magnitude with time is neither negligible in relation to the
mean value nor monotonic.
3

---------------------- Page: 8 ----------------------
©
ISO
ISO 2394:1998(E)
2.3.4  accidental action: Action that is unlikely to occur with a significant value on a given structure over a given
reference period.
NOTE —  Accidental actions are in most cases of short duration.
2.3.5  fixed action: Action which has a fixed distribution on a structure, such as its magnitude and direction are
determined unambiguously for the whole structure when determined at one point on the structure.
2.3.6  free action: Action which may have an arbitrary spatial distribution over the structure within given limits.
2.3.7  static action: Action which will not cause significant acceleration of the structure or structural elements.
2.3.8  dynamic action: Action which may cause significant acceleration of the structure or structural elements.
2.3.9  bounded action: Action which has a limiting value which cannot be exceeded and which is exactly or
approximately known.
2.3.10  unbounded action: Action which has no known limiting values.
2.3.11  representative value of an action: A value used for the verification of a limit state.
NOTE —  Representative values consist of characteristic values, combination values, frequent values and quasi-permanent
values, but may also consist of other values.
2.3.12  characteristic value of an action: Principal representative value.
NOTE —  It is chosen either on a statistical basis, so that it can be considered to have a specified probability of not being
exceeded towards unfavourable values during a reference period, or on acquired experience, or on physical constraints.
2.3.13  combination value: Value chosen, in so far as it can be fixed on statistical bases, so that the probability
that the action effect values caused by the combination will be exceeded is approximately the same as when a
single action is considered.
2.3.14  frequent value: Value determined, in so far as it can be fixed on statistical bases, so that:
— the total time, within a chosen period of time, during which it is exceeded is only a small given part of the
chosen period of time; or
— the frequency of its exceedance is limited to a given value.
2.3.15  quasi-permanent value: Value determined, in so far as it can be fixed on statistical bases, so that the total
time, within a chosen period of time, during which it is exceeded is of the magnitude of half the period.
2.3.16  design value of an action, F : Value obtained by multiplying the representative value by the partial
d
factor g .
F
2.3.17  load arrangement: Identification of the position, magnitude and direction of a free action.
2.3.18  load case: Compatible load arrangements, set of deformations and imperfections considered for a
particular verification.
2.3.19  load combination: Set of design values used for the verification of the structural reliability for a limit state
under the simultaneous influence of different actions.
2.3.20  environmental influence: Mechanical, physical, chemical or biological influence which may cause
deterioration of the materials constituting a structure, which in turn may affect its serviceability and safety in an
unfavourable way.
4

---------------------- Page: 9 ----------------------
©
ISO
ISO 2394:1998(E)
2.4  Terms relating to structural response, resistance, material properties and geometrical
quantities
2.4.1  characteristic value of a material property: An a priori specified fractile of the statistical distribution of the
material property in the supply produced within the scope of the relevant material standard.
2.4.2  characteristic value of a geometrical quantity: A quantity usually corresponding to dimensions specified
by the designer.
2.4.3  design value of a material property: Value obtained by dividing the characteristic value by a partial factor
g or, in special circumstances, by direct assessment.
M
2.4.4  design value of a geometrical quantity: Characteristic value plus or minus an additive geometrical
quantity.
2.4.5  conversion factor: Factor which converts properties obtained from test specimens to properties
corresponding to the assumptions made in calculation models.
2.4.6  conversion function: Function which converts properties obtained from test specimens to properties
corresponding to the assumptions made in calculation models.
3  Symbols
NOTE —  The symbols used generally are listed below. Those which are not general and which are used only in one clause
(and are explained there) are not listed.
3.1  Main letters
A Accidental action
C Serviceability constraint
F Action in general
F Basic action variable
0
F Representative value of an action
r
G Permanent action
Q Variable action
R Resistance
S Action effect
W Action model variable
X Basic variable
Y Model output variable
a Geometrical quantity
Additive geometrical quantity
Da
f Material property
5

---------------------- Page: 10 ----------------------
©
ISO
ISO 2394:1998(E)
p Probability of failure
f
p Specified value of p
fs f
Time
t
b Reliability index
g Partial factor
g Partial factor for actions
f
g Generalized partial factor for actions taking account of model and geometric uncertainties
F
g Partial factor for permanent actions
G
g Partial factor for variable actions
Q
g Partial factor for material properties
m
g Generalized partial factor for resistance properties taking account of material, model and geometric
M
uncertainties
g Partial factor for model uncertainties
D
g Factor by which the importance of the structure and the consequences of failure are taken into account
n
q Parameter which contains model uncertainties
q Value for action effects
s
q Value for resistance
R
j Function of action variables
Y Factor for determining combination values of actions
0
Y Factor for determining frequent values of actions
1
Y Factor for determining quasi-permanent values of actions
2
g(X,t) Limit state function
3.2  Subscripts
i Basic variable (mainly action) number i
j Action number j
k Characteristic value
d Design value
4  Requirements and concepts
4.1  Fundamental requirements
Structures and structural elements shall be designed, constructed and maintained in such a way that they are suited
for their use during the design working life and in an economic way.
6

---------------------- Page: 11 ----------------------
©
ISO
ISO 2394:1998(E)
In particular they shall, with appropriate degrees of reliability, fulfil the following requirements:
— they shall perform adequately under all expected actions (serviceability limit state requirement);
— they shall withstand extreme and/or frequently repeated actions occurring during their construction and
anticipated use (ultimate limit state requirement);
— they shall not be damaged by events like flood, land slip, fire, explosions, impact or consequences of human
errors, to an extent disproportionate to the original cause (structural integrity requirement).
The appropriate degree of reliability should be judged with due regard to the possible consequences of failure and
the expense, level of effort and procedures necessary to reduce the risk of failure (see 4.2).
The measures that can be taken to achieve the appropriate degree of reliability include:
— choice of structural system, proper design and analysis;
— implementation of a quality policy;
— design for durability and maintenance;
— protective measures.
These items will be treated in 4.3 to 4.5.
4.2  Reliability differentiation of structures
The expression "with appropriate degrees of reliability" used in 4.1 means that the degree of reliability should be
adopted taking account of:
— the cause and mode of failure implying that a structure or structural element which would be likely to collapse
suddenly without warning should be designed for a higher degree of reliability than one for which a collapse is
preceded by some kind of warning in such a way that measures can be taken to limit the consequences;
— the possible consequences of failure in terms of risk to life, injury, potential economic losses and the level of
social inconvenience;
— the expense, level of effort and procedures necessary to reduce the risk of failure;
— the social and environmental conditions in a particular location.
Differentiation of the required degrees of reliability may be obtained by the classification of whole structures or by
the classification of structural elements. Thus, as an example, degrees of reliability may be selected according to
the consequences of failure as follows:
a) risk to life low, economic, social and environmental consequences small or negligible;
b) risk to life medium, economic, social or environmental consequences considerable;
c) risk to life high, economic, social or environmental consequences very great.
The required reliability related to structural safety or serviceability may be achieved by suitable combinations of the
following measures.
a) Measures relating to design:
— serviceability requirements;
— the choice of the values of action variables;
7

---------------------- Page: 12 ----------------------
©
ISO
ISO 2394:1998(E)
— the choice of the degree of reliability for the design calculations;
— consideration of durability;
— consideration of the degree of structural integrity (robustness), see 4.3;
— the amount and quality of preliminary investigations of soils and possible environmental influences;
— the accuracy of the mechanical models used;
— the stringency of the detailing rules.
b) Measures relating to quality assurance to reduce the risk of hazards in:
— gross human errors;
— design;
— execution.
4.3  Structural design
A failure of a structure or part of it may occur due to:
— an extremely unfavourable combination of actions, material properties, geometrical quantities, etc., all of which
are associated with ordinary use and other ordinary circumstances;
— effects of exceptional but foreseeable actions or environmental influences, for example, collision or extreme
climatic influences;
— consequences of an error, such as lack of information, omission, misunderstanding and lack of communication,
negligence, misuse, etc.;
— influences that are not foreseen.
NOTE —  The term "exceptional" refers to circumstances and/or actions that are present only during a small portion of the life
and/or with a low probability. Depending on the type of structure, these actions may or may not be considered explicitly in
design.
No structure can be expected to function adequately in all cases if exceptional actions or exceptionally low
resistance occur, but the foreseeable scope of damage should be limited to an extent not disproportionate to the
original cause. Thus measures should be taken to counter such events. The measures would basically consist of
one or more of the following.
a) Designing and maintaining the structure according to the rules given in the following clauses for conditions
associated with ordinary use and other ordinary circumstances.
b) Design of the essential load-bearing members of a structure for specified exceptional actions which may be
caused by accidents or similar occurrences.
NOTE —  The intention of such design criteria is that they should also cover the effect of the majority of unforeseen
events.
The structural layout should be checked to identify "key" structural elements, whose failure would cause the
collapse of more than a limited portion of the structure close to the element in question. Where such structural
elements are identified and the structural layout cannot be revised to avoid them, the design should take their
importance into account.
c) Protection against foreseeable actions and elimination of errors.
A careful check should be made and appropriate action taken to ensure that there is no inherent weakness in
the structural layout and that adequate means exist to transmit all loads safely to the foundations.
8

---------------------- Page: 13 ----------------------
©
ISO
ISO 2394:1998(E)
Protective measures should be introduced, for example, safeguarding against vehicular impact by the provision
of additional protection such as bollards.
The probability of gross design and construction errors should be reduced by appropriate quality assurance
and/or quality control measures, as described in 4.4.
d) Design of the structure in such a way that local damage does not lead to immediate collapse of the whole structure
or a significant part of it.
As a design assumption, the following may be chosen to represent local damage. The structure shall be
designed and detailed so that any load-bearing elements other than the "key" structural elements can be
removed without causing the collapse of more than a limited portion close to the element in question. In the
event of the removal of a non-key structural element, a less than normal reliability for the remaining structure
will be considered acceptable provided that the structure is repaired to normal reliability standard within a
reasonably short period of time after damag
...