Surface active agents and soaps — Determination of water content — Azeotropic distillation method

Agents de surface et savons — Détermination de la teneur en eau — Méthode par entraînement azéotropique

General Information

Status
Withdrawn
Publication Date
31-Jan-1978
Withdrawal Date
31-Jan-1978
Current Stage
9599 - Withdrawal of International Standard
Completion Date
01-Jun-1989
Ref Project

Relations

Buy Standard

Standard
ISO 4318:1978 - Surface active agents and soaps -- Determination of water content -- Azeotropic distillation method
English language
2 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 4318:1978 - Surface active agents and soaps — Determination of water content — Azeotropic distillation method Released:2/1/1978
French language
2 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

INTERNATIONAL STANDARD ;-B 4318
‘*I&
INTERNATIONAL ORGANIZATION FOR STANDAROIZATION *MEELlYHAPOAHAR OPîAHM3AUHR no CTAHnAPTM3AUHH .ORGANISATION INTERNATIONALE DE NORMALISATION
0
Surface active agents and soaps - Determination of water
content - Azeotropic distillation method
Agents de surface et savons - Détermination de la teneur en eau - Méthode par entraînement azéotropique
i
UDC 661.185 : 543.812 Ref. No. IS0 4318-1978 (E)
Descriptors : surfactants, soaps, chemical analysis, determination of content, water, azeotropic method.

---------------------- Page: 1 ----------------------
INTERNATIONAL STAN DARD IS0 4318-1978 (E)
Surface active agents and soaps - Determination of water
content - Azeotropic distillation method
1 SCOPE
6 APPARATUS
This International Standard specifies an azeotropic distil-
Ordinary laboratory apparatus and
lation method for the determination of the water content
of surface active agents and soaps. Volatile matter soluble
6.1 Distillation apparatus, comprising the following
in water but insoluble in xylene will be included in the
items :
resuit.
2 FIELD OF APPLICATION
6.1.1 Flask, of minimum capacity 500ml, fitted with
a ground glass joint, complying with IS0 383.
This method is applicable to products in the form of
powders having water contents greater than 5 % (m/m),
and in the form of pastes and solutions. It is not applicable
6.1.2 Graduated collecting cylinders, of capacity 2 or
to samples containing water-soluble volatile compounds,
10 ml (Dean-Stark receiver).
for example ethanol.
The graduation interval and its tolerance for the 2 ml
With regard to soaps, as the results cannot be obtained
graduated collecting cylinders shall be
with an accuracy greater than 0,3 %, this method should
be use
...

INTERNATIONAL ORGANIZATION FOR STANDARDIZATION MEXLlYHAF'OLIHAR OPrAHM3AUMR I70 CTAHLIAPTM3AUMM.ORGANlSATlON INTERNATIONALE DE NORMALISATION
' 0 Agents de surface et savons - Détermination de la teneur en
eau - Méthode par entraînement azéotropique
Surface active agents and soaps - Determination of water content - Azeotropic distillation method
Première édition - 1978-02-01
CDU 661.185 : 543.812 Réf. no : IS0 4318-1978 (FI
Descripteurs : agent de surface, savon, analyse chimique, dosage, eau, méthode par entraînement azéotropique.
Prix basé sur 2 pages

---------------------- Page: 1 ----------------------
NORME INTERNATIONALE IS0 4318-1978 (F)
Agents de surface et savons - Détermination de la teneur en
eau - Méthode par entraînement azéotropique
5 RÉACTIF
1 OBJET
5.1 Xylène (n'importe lequel des isomères ou un mélange
La présente Norme internationale spécifie une méthode de
de ces isomères en n'importe quelle proportion), point
détermination de la teneur en eau des agents de surface et
d'ébullition compris entre 130 et 140 OC.
des savons, par entraînement azéotropique. Les matières
volatiles solubles dans l'eau, mais insolubles dans le xylène,
NOTE - Le xylene étant un solvant toxique, il convient de se
seront comprises dans le résultat.
conformer aux consignes de sécurité relatives à la manipulation
1)
des solvants toxiques.
2 DOMAINE D'APPLICATION
6 APPAREILLAGE
Cette méthode par entraînement azéotropique est appli-
à l'état pulvérulent dont la teneur en eau
cable aux produits
Matériel courant de laboratoire, et notamment :
est supérieure à 5 % (rn/m), et à ceux en pâte et en soiu-
tion. Elle n'est pas applicable aux échantillons contenant
6.1 Appareil d'entraînement, comprenant les éléments
des composés volatils solubles dans l'eau (par exemple
suivants :
étha
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.