ISO general purpose metric screw threads — Tolerances — Part 4: Limits of sizes for hot-dip galvanized external screw threads to mate with internal screw threads tapped with tolerance position H or G after galvanizing

This part of ISO 965 specifies deviations and limits of sizes for pitch and crest diameters for ISO general purpose metric external screw threads conforming to ISO 262 having a basic profile according to ISO 68-1. External screw threads according to this part of ISO 965 are intended to mate with internal screw threads tapped with tolerance position H or G after hot dip galvanizing. The limits of sizes for the tolerance quality specified are derived from tolerances specified in ISO 965-1 and the fundamental deviations according to the following formula: esaz = 2(300 + 20P) where es is expressed in micrometers; P is expressed in millimeters. Products made with thread tolerances in accordance with this part of ISO 965 may show failure at lower ultimate tensile loads than those specified in ISO 898-1 due to reduction of the stress area. External screw threads with thread tolerances according to this part of ISO 965 must not be mated with internal screw threads with thread tolerances according to ISO 965-5 because such combinations will create severe risk for thread stripping. NOTE If the tolerance class 6az is not specified the external screw threads are to mate with internal screw threads with tolerance position 6AZ if the products are centrifuged and with hot-dip galvanized internal screw threads with tolerance position 6AX if the products are not centrifuged.

Filetages métriques ISO pour usages généraux — Tolérances — Partie 4: Dimensions limites pour filetages extérieurs galvanisés à chaud pour assemblages avec des filetages intérieurs de position de tolérance H ou G après galvanisation

La présente partie de l'ISO 965 spécifie les écarts et les dimensions limites des diamètres sur flancs et au sommet des filetages extérieurs métriques ISO d'usages généraux, conformément à l'ISO 262, de profil de base conforme à l'ISO 68-1. Les filetages extérieurs conformes à la présente partie de l'ISO 965 sont prévus pour s'assembler avec des filetages intérieurs de position de tolérance H ou G après galvanisation à chaud. Les dimensions limites, spécifiées pour la classe de qualité adoptée, sont dérivées des tolérances spécifiées dans l'ISO 965-1, et leurs écarts fondamentaux de la formule suivante : esaz = - (300 + 20P) où es est exprimé en micromètres; P est exprimé en millimètres. Les produits réalisés avec des tolérances de filetage conformes à la présente partie de l'ISO 965 peuvent présenter des défaillances à des charges de rupture plus faibles que celles spécifiées dans l'ISO 898-1, du fait de la réduction de la zone de contraintes. Il ne faut pas assembler des filetages extérieurs réalisés avec des tolérances de filetage conformes à la présente partie de l'ISO 965 avec des filetages intérieurs de tolérances de filetage conformes à l'ISO 965-5, car une telle combinaison crée des risques importants d'arrachement de filetage. NOTE Si la classe de tolérance 6az n'est pas spécifiée, les filetages extérieurs sont à assembler avec des filetages intérieurs de tolérance 6AZ si les produits sont centrifugés, et avec des filetages intérieurs galvanisés à chaud de position de tolérance 6AX si les produits ne sont pas centrifugés.

General Information

Status
Withdrawn
Publication Date
19-Dec-1998
Withdrawal Date
19-Dec-1998
Technical Committee
Drafting Committee
Current Stage
9599 - Withdrawal of International Standard
Completion Date
06-Jul-2021
Ref Project

Relations

Buy Standard

Standard
ISO 965-4:1998 - ISO general purpose metric screw threads -- Tolerances
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 965-4:1998 - Filetages métriques ISO pour usages généraux -- Tolérances
French language
4 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

INTERNATIONAL ISO
STANDARD 965-4
First edition
1998-12-15
ISO general purpose metric screw
threads — Tolerances —
Part 4:
Limits of sizes for hot-dip galvanized external
screw threads to mate with internal screw
threads tapped with tolerance position H or G
after galvanizing
Filetages métriques ISO pour usages généraux — Tolérances —
Partie 4: Dimensions limites pour filetages extérieurs galvanisés à chaud
pour assemblages avec des filetages intérieurs de position de tolérance H
ou G après galvanisation
A
Reference number
ISO 965-4:1998(E)

---------------------- Page: 1 ----------------------
ISO 965-4:1998(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO
member bodies). The work of preparing International Standards is normally carried out through ISO technical
committees. Each member body interested in a subject for which a technical committee has been established has
the right to be represented on that committee. International organizations, governmental and non-governmental, in
liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical
Commission (IEC) on all matters of electrotechnical standardization.
Draft International Standards adopted by the technical committees are circulated to the member bodies for voting.
Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote.
International Standard ISO 965-4 was prepared by Technical Committee ISO/TC 1, Screw threads, Subcommittee
SC 2, Tolerances.
ISO 965 consists of the following parts, under the general title ISO general purpose metric screw threads –
Tolerances
— Part 1: Principles and basic data
— Part 2: Limits of sizes for general purpose bolt and nut threads – Medium quality
— Part 3: Deviations for constructional screw threads
— Part 4: Limits of sizes for hot-dip galvanized external threads to mate with internal threads tapped with
tolerance position H or G after galvanizing
— Part 5: Limits of sizes for internal screw threads to mate with hot-dip galvanized external screw threads with
maximum size of tolerance position h before galvanizing
©  ISO 1998
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic
or mechanical, including photocopying and microfilm, without permission in writing from the publisher.
International Organization for Standardization
Case postale 56 • CH-1211 Genève 20 • Switzerland
Internet iso@iso.ch
Printed in Switzerland
ii

---------------------- Page: 2 ----------------------
INTERNATIONAL STANDARD  © ISO ISO 965-4:1998(E)
ISO general purpose metric screw threads — Tolerances —
Part 4:
Limits of sizes for hot-dip galvanized external screw threads to mate
with internal screw threads tapped with tolerance position H or G after
galvanizing
1 Scope
This part of ISO 965 specifies deviations and limits of sizes for pitch and crest diameters for ISO general purpose
metric external screw threads conforming to ISO 262 having a basic profile according to ISO 68-1.
External screw threads according to this part of ISO 965 are intended to mate with internal screw threads tapped
with tolerance position H or G after hot dip galvanizing.
The limits of sizes for the tolerance quality specified are derived from tolerances specified in ISO 965-1 and the
fundamental deviations according to the following formula:
es = 2(300 + 20P)
az
where
es is expressed in micrometres;
P is expressed in millimetres.
Products made with thread tolerances in accordance with this part of ISO 965 may show failure at lower ultimate
tensile loads than those specified in ISO 898-1 due to reduction of the stress area.
External screw threads with thread tolerances according to this part of ISO 965 must not be mated with internal
screw threads with thread tolerances according to ISO 965-5 because such combinations will create severe risk for
thread stripping.
NOTE If the tolerance class 6az is not specified the external screw threads are to mate with internal screw threads with
tolerance position 6AZ if the products are centrifuged and with hot-dip galvanized internal screw threads with tolerance position
6AX if the products are not centrifuged.
2 Normative references
The following standards contain provisions which, through reference in this text, constitute provisions of this part of
ISO 965. At the time of publication, the editions indicated were valid. All standards are subject to revision, and
parties to agreements based on
...

NORME ISO
INTERNATIONALE 965-4
Première édition
1998-12-15
Filetages métriques ISO pour usages
généraux — Tolérances —
Partie 4:
Dimensions limites pour filetages extérieurs
galvanisés à chaud pour assemblages avec
des filetages intérieurs de position de
tolérance H ou G après galvanisation
ISO general purpose metric screw threads — Tolerances —
Part 4: Limits of sizes for hot-dip galvanized external screw threads to mate
with internal screw threads tapped with tolerance position H or G after
galvanizing
A
Numéro de référence
ISO 965-4:1998(F)

---------------------- Page: 1 ----------------------
ISO 965-4:1998(F)
Avant-propos
L'ISO (Organisation internationale de normalisation) est une fédération mondiale d'organismes nationaux de
normalisation (comités membres de l'ISO). L'élaboration des Normes internationales est en général confiée aux
comités techniques de l'ISO. Chaque comité membre intéressé par une étude a le droit de faire partie du comité
technique créé à cet effet. Les organisations internationales, gouvernementales et non gouvernementales, en
liaison avec l'ISO, participent également aux travaux. L'ISO collabore étroitement avec la Commission
électrotechnique internationale (CEI) en ce qui concerne la normalisation électrotechnique.
Les projets de Normes internationales adoptés par les comités techniques sont soumis aux comités membres pour
vote. Leur publication comme Normes internationales requiert l'approbation de 75 % au moins des comités
membres votants.
La Norme internationale ISO 965-4 a été élaborée par le comité technique ISO/TC 1, Filetages, sous-comité SC 2,
Tolérances.
L’ISO 965 comprend les parties suivantes, présentées sous le titre général Filetages métriques ISO pour usages
généraux — Tolérances:
 Partie 1: Principes et données fondamentales
 Partie 2: Dimensions limites pour filetages intérieurs et extérieurs d'usages généraux — Qualité moyenne
 Partie 3: Écarts pour filetages de construction
 Partie 4: Dimensions limites pour filetages extérieurs galvanisés à chaud pour assemblages avec des filetages
intérieurs de position de tolérance H ou G après galvanisation
 Partie 5: Dimensions limites pour filetages intérieurs pour assemblages avec des filetages extérieurs
galvanisés à chaud de position de tolérance maximale h avant galvanisation
©  ISO 1998
Droits de reproduction réservés. Sauf prescription différente, aucune partie de cette publication ne peut être reproduite ni utilisée sous quelque
forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie et les microfilms, sans l'accord écrit de l'éditeur.
Organisation internationale de normalisation
Case postale 56 • CH-1211 Genève 20 • Suisse
Internet iso@iso.ch
Imprimé en Suisse
ii

---------------------- Page: 2 ----------------------
©
NORME INTERNATIONALE  ISO ISO 965-4:1998(F)
Filetages métriques ISO pour usages généraux — Tolérances —
Partie 4:
Dimensions limites pour filetages extérieurs galvanisés à chaud pour
assemblages avec des filetages intérieurs de position de tolérance H
ou G après galvanisation
1 Domaine d’application
La présente partie de l'ISO 965 spécifie les écarts et les dimensions limites des diamètres sur flancs et au sommet
des filetages extérieurs métriques ISO d'usages généraux, conformément à l'ISO 262, de profil de base conforme à
l'ISO 68-1.
Les filetages extérieurs conformes à la présente partie de l'ISO 965 sont prévus pour s'assembler avec des
filetages intérieurs de position de tolérance H ou G après galvanisation à chaud.
Les dimensions limites, spécifiées pour la classe de qualité adoptée, sont dérivées des tolérances spécifiées dans
l'ISO 965-1, et leurs écarts fondamentaux de la formule suivante:
es = - (300 + 20P)
az

es est exprimé en micromètres;
P est exprimé en millimètres.
Les produits réalisés avec des tolérances de filetage conformes à la présente partie de l'ISO 965 peuvent présenter
des défaillances à des charges de rupture plus faibles que celles spécifiées dans l'ISO 898-1, du fait de la réduction
de la zone de contraintes.
Il ne faut pas assembler des filetages extérieurs réalisés avec des tolérances de filetage conformes à la présente
partie de l'ISO 965 avec des filetages intérieurs de tolérances de filetage conformes à l'ISO 965-5, car une telle
combinaison crée des risques importants d'arrachement de filetage.
NOTE Si la classe de tolérance 6az n'est pas spécifiée, les filetages extérieurs sont à assembler avec des filetages
intérieurs de tolérance 6AZ si les produits sont centrifugés, et avec des filetages intérieurs galvanisés à chaud de position de
tolérance 6AX si les produits ne sont pas centrifugés.
1

---------------------- Page: 3 ----------------------
© ISO
ISO 965-4:1998(F)
2 Références normatives
Les normes suivantes contiennent des dispositions qui, par suite de la référence qui en est faite, constituent des
dispositions valables pour la présente parti
...

Questions, Comments and Discussion