Copper, lead, zinc and nickel sulfide concentrates — Determination of arsenic — Part 2: Acid digestion and inductively coupled plasma atomic emission spectrometric method

ISO 13547-2:2014 specifies an acid digestion and inductively coupled plasma atomic emission spectrometric (ICP-AES) method for the determination of the mass fraction of arsenic in copper, lead, zinc, and nickel sulfide concentrates as follows: for copper sulfide concentrates, the method is applicable to the determination of mass fractions of arsenic from 0,05 % to 2,0 %; for lead sulfide concentrates, the method is applicable to the determination of mass fractions of arsenic from 0,05 % to 1,0 %; for zinc sulfide concentrates, the method is applicable to the determination of mass fractions of arsenic from 0,05 % to 0,6 %; for nickel sulfide concentrates, the method is applicable to the determination of mass fraction of arsenic from 0,05 % to 1,0 %.

Concentrés sulfurés de cuivre, de plomb et de zinc — Dosage de l'arsenic — Partie 2: Méthode par digestion acide et plasma induit par haute fréquence

General Information

Status
Published
Publication Date
09-Nov-2014
Current Stage
9093 - International Standard confirmed
Completion Date
21-May-2020
Ref Project

Buy Standard

Standard
ISO 13547-2:2014 - Copper, lead, zinc and nickel sulfide concentrates -- Determination of arsenic
English language
13 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

INTERNATIONAL ISO
STANDARD 13547-2
First edition
2014-11-15
Copper, lead, zinc and nickel sulfide
concentrates — Determination of
arsenic —
Part 2:
Acid digestion and inductively coupled
plasma atomic emission spectrometric
method
Concentrés sulfurés de cuivre, de plomb et de zinc — Dosage de
l’arsenic —
Partie 2: Méthode par digestion acide et plasma induit par haute
fréquence
Reference number
ISO 13547-2:2014(E)
©
ISO 2014

---------------------- Page: 1 ----------------------
ISO 13547-2:2014(E)

COPYRIGHT PROTECTED DOCUMENT
© ISO 2014
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form
or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, without prior
written permission. Permission can be requested from either ISO at the address below or ISO’s member body in the country of
the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii © ISO 2014 – All rights reserved

---------------------- Page: 2 ----------------------
ISO 13547-2:2014(E)

Contents Page
Foreword .iv
1 Scope . 1
2 Normative references . 1
3 Principle . 2
4 Reagents . 2
5 Apparatus . 4
6 Sampling and sample preparation . 4
6.1 Laboratory sample . 4
6.2 Test sample . 4
6.3 Test portion . 4
7 Procedure. 5
7.1 Number of determinations . 5
7.2 Blank test . 5
7.3 Dissolution of the test portion . 5
7.4 Removal of lead sulfate . 5
7.5 Dissolution of the insoluble residue . 5
7.6 Preparation of test solutions . 6
7.7 Preparation of calibration solutions . 6
7.8 Preparation of arsenic calibration curve . 6
7.9 Determination of arsenic content in test solutions . 7
8 Expression of results . 7
9 Precision . 7
9.1 Expression of precision . 7
9.2 Method for obtaining the final result . 8
9.3 Between-laboratories precision . 8
9.4 Check of trueness . 9
10 Test report .10
Annex A (normative) Procedure for the preparation and determination of the mass of a pre-dried
test portion .11
Annex B (normative) Flowsheet of the procedure for the acceptance of analytical values for
test samples .13
© ISO 2014 – All rights reserved iii

---------------------- Page: 3 ----------------------
ISO 13547-2:2014(E)

Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the
different types of ISO documents should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of any
patent rights identified during the development of the document will be in the Introduction and/or on
the ISO list of patent declarations received (see www.iso.org/patents).
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation on the meaning of ISO specific terms and expressions related to conformity
assessment, as well as information about ISO’s adherence to the WTO principles in the Technical Barriers
to Trade (TBT) see the following URL: Foreword - Supplementary information
ISO 13547 consists of the following parts, under the general title Copper, lead, zinc and nickel sulfide
concentrates — Determination of arsenic:
— Part 1: Iron hydroxide concentration and inductively coupled plasma atomic emission spectrometric
— Part 2: Acid digestion and inductively coupled plasma atomic emission spectrometric method
iv © ISO 2014 – All rights reserved

---------------------- Page: 4 ----------------------
INTERNATIONAL STANDARD ISO 13547-2:2014(E)
Copper, lead, zinc and nickel sulfide concentrates —
Determination of arsenic —
Part 2:
Acid digestion and inductively coupled plasma atomic
emission spectrometric method
WARNING — This International Standard may involve hazardous materials, operations,
and equipment. It is the responsibility of the user of this International Standard to establish
appropriate health and safety practices and determine the applicability of regulatory limitations
prior to use.
1 Scope
This International Standard specifies an acid digestion and inductively coupled plasma atomic emission
spectrometric (ICP-AES) method for the determination of the mass fraction of arsenic in copper, lead,
zinc, and nickel sulfide concentrates as follows:
a) for copper sulfide concentrates, the method is applicable to the determination of mass fractions of
arsenic from 0,05 % to 2,0 %;
b) for lead sulfide concentrates, the method is applicable to the determination of mass fractions of
arsenic from 0,05 % to 1,0 %;
c) for zinc sulfide concentrates, the method is applicable to the determination of mass fractions of
arsenic from 0,05 % to 0,6 %;
d) for nickel sulfide concentrates, the method is applicable to the determination of mass fraction of
arsenic from 0,05 % to 1,0 %.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
ISO 648, Laboratory glassware — Single-volume pipettes
ISO 1042, Laboratory glassware — One-mark volumetric flasks
ISO 4787, Laboratory glassware — Volumetric instruments — Methods for testing of capacity and for use
ISO 8466-2, Water quality — Calibration and evaluation of analytical methods and estimation of performance
characteristics — Part 2: Calibration strategy for non-linear second-order calibration functions
ISO 9599, Copper, lead and zinc sulfide concentrates — Determination of hygroscopic moisture in the
analysis sample — Gravimetric method
ISO 12743:2006, Copper, lead, zinc and nickel concentrates — Sampling procedures for determination of
metal and moisture content
© ISO 2014 – All rights reserved 1

---------------------- Page: 5 ----------------------
ISO 13547-2:2014(E)

3 Principle
The test portion is decomposed in nitric and sulphuric acids and arsenic is determined by comparison
against matrix-matched standards using ICP-AES.
4 Reagents
During the analysis, use only reagents of recognized analytical grade and distilled water or water of
equivalent purity.
4.1 Sodium hydroxide (NaOH), AR grade.
4.2 Arsenic trioxide (As O ), AR grade.
2 3
4.3 Iron(III) chloride hexahydrate (FeCl •6H O), AR grade (<0,000 05 % Arsenic).
3 2
4.4 Copper metal (≥99,99 %).
4.5 Zinc metal (≥99,99 %).
4.6 Lead metal (≥99,99 %).
4.7 Nickel metal (≥99,99 %).
4.8 Ammonium acetate, AR grade.
4.9 Nitric acid (ρ 1,42 g/ml).
20
4.10 Nitric acid, dilute (1 + 1).
Slowly add 50 ml of nitric acid (4.9) to 50 ml of water while stirring.
4.11 Hydrochloric acid (ρ 1,16 g/ml).
20
4.12 Hydrochloric acid, dilute (1 + 1).
Slowly add 50 ml of hydrochloric acid (4.11) to 50 ml of water while stirring.
4.13 Sulphuric acid (ρ 1,84 g/ml).
20
4.14 Sulphuric acid, dilute (1 + 1).
Slowly add 50 ml of sulphuric acid (4.12) to 50 ml of water while stirring.
The addition of sulphuric acid to water generates heat and shall be performed with adequate precautions.
4.15 Sulphuric acid, dilute (1 + 50).
Slowly and with stirring, add 20 ml of sulphuric acid (4.12) to 1 000 ml of water.
4.16 Hydrofluoric acid (ρ 1,13 g/ml).
20
2 © ISO 2014 – All rights reserved

---------------------- Page: 6 ----------------------
ISO 13547-2:2014(E)

4.17 Sodium hydroxide solution (20 % w/v).
Weigh 20,0 g of sodium hydroxide (4.1) in a polytetrafluoroethylene beaker (5.5). Add 50 ml of water and
allow the solid to dissolve. Dilute the solution to 100 ml and store in a labelled polyethylene container.
4.18 Saturated solution of potassium chlorate in nitric acid.
Superfluous potassium chlorate is added into the nitric acid and then the deposited solution is allowed
to form the saturated solution.
4.19 Ammonium acetate (25 % w/v).
Dissolve 25,0 g of ammonium acetate (4.8) into 100 ml water.
4.20 Arsenic standard, 1 ml contains 1 mg of As.
Weigh 1 320,3 g of arsenic trioxide (4.2) into a 400 ml beaker and add 5 ml of sodium hydroxide solution
(4.17). Warm slightly to dissolve. When dissolution is complete, cool and add 40 ml of nitric acid (4.9).
Transfer to a 1 000 ml volumetric flask containing 60 ml of nitric acid (4.9). Fill up nearly to the mark
with water, mix, and equilibrate at room temperature, then fill up exactly to the mark and mix again.
Store in a labelled container.
Alternatively, purchase a suitable high quality prepared standard.
Before use, compare this International Standard against a traceable National Standard to ensure
suitability for use.
4.21 Arsenic standard, 1 ml contains 0,2 mg of As.
Pipette 40 ml of arsenic standard (4.20) into a 200 ml volumetric flask containing 2 ml hydrochloric
acid (4.11). Fill up nearly to the mark with water, mix, and equilibrate at room temperature, then fill up
exactly to the mark and mix again. Store in a labelled glass container.
4.22 Copper matrix/interference standard (25,0 mg/ml).
Dissolve 2,5 g of copper metal (4.4) with 50 ml of warm dilute nitric acid (4.10). Evaporate to approximately
25 ml in order to remove nitrogen oxides. Transfer to a 100 ml volumetric flask, add 5 ml concentrated
hydrochloric acid, then fill up with water nearly to the mark. Mix and cool to room temperature, then fill
up exactly to the mark and mix again.
4.23 Zinc matrix/interference standard (32,5 mg/ml).
Dissolve 3,25 g of zinc metal (4.5) with 50 ml of warm dilute hydrochloric acid (1+1). Transfer to a 100 ml
volumetric flask, fill up with water nearly to the mark, mix, and cool to room temperature, then fill up
exactly to the mark and mix again.
4.24 Iron matrix/interference standard (10 mg/ml).
Dissolve 48,4 g iron (III) chloride hexahydrate (4.3) in 200 ml of water. Add 10 ml of hydrochloric acid
(4.11) and make up to 1 000 ml with water and mix.
4.25 Lead matrix/interference standard (37,5 mg/ml).
Dissolve 3,75 g of lead metal (4.6) by adding 40 ml of water and 20 ml of nitric acid (4.9) and heat to
dissolve. Transfer to a 100 ml volumetric flask, fill up with water nearly to the mark, mix, and cool to
room temperature, then fill up exactly to the mark and mix again.
© ISO 2014 – All rights reserved 3

---------------------- Page: 7 ----------------------
ISO 13547-2:2014(E)

4.26 Nickel matrix/interference standard (10 mg/ml).
Dissolve 1,0 g of nickel metal (4.7) in 50 ml of dilute nitric acid (4.10) and heat until all nitrogen oxides
are expelled. The volume will be about 25 ml. Transfer to a 100 ml volumetric flask. Add 25 ml of
hydrochloric acid (4.11) and fill up with water nearly to the mark, mix, and cool to room temperature,
then fill up exactly to the mark and mix again.
5 Apparatus
All laboratory glassware and equipment shall be shown to be free of arsenic contamination.
5.1 Balance, sensitive to ±0,1 mg.
5.2 Normal laboratory glassware, complying with ISO 648 and ISO 1042 and used in accordance with
ISO 4787.
5.3 Inductively coupled plasma atomic emission spectrometer (ICP-AES).
The emission wavelength should be set to 193,696 nm or 197,197 nm.
1)
5.4 Insolubles filter paper, Whatman® No. 40 or equivalent.
5.5 Polytetrafluoroethylene beaker, 200 ml capacity.
6 Sampling and sample preparation
6.1 Laboratory sample
Laboratory samples shall be taken and prepared in accordance with the procedures described in
ISO 12743.
As arsenic can evaporate from samples at elevated temperatures, consideration should be given to
preparing a separate chemical analysis
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.