Acoustics — Hearing protectors — Part 2: Estimation of effective A-weighted sound pressure levels when hearing protectors are worn

This document specifies three methods (the octave-band, HML and SNR methods) of estimating the A-weighted sound pressure levels effective when hearing protectors are worn. The methods are applicable to either the sound pressure level or the equivalent continuous sound pressure level of the noise. Although primarily intended for steady noise exposures, the methods are also applicable to noises containing impulsive components. It is possible that these methods could not be suitable for use with peak sound pressure level measurements. The octave-band, H, M, L or SNR values are suitable for establishing sound attenuation criteria for selecting or comparing hearing protectors, and/or setting minimum acceptable sound attenuation requirements.

Acoustique — Protecteurs individuels contre le bruit — Partie 2: Estimation des niveaux de pression acoustique pondérés A en cas d'utilisation de protecteurs individuels contre le bruit

Le présent document spécifie trois méthodes (la méthode par bande d'octave, la méthode HML et la méthode SNR) pour estimer les niveaux de pression acoustique effectifs pondérés A en cas d'utilisation de protecteurs individuels contre le bruit. Ces méthodes s'appliquent soit au niveau de pression acoustique, soit au niveau de pression acoustique continu équivalent du bruit. Bien que ces méthodes soient essentiellement prévues pour des expositions à un bruit continu, elles s'appliquent également à des bruits comportant des composantes impulsives. Il est possible que ces méthodes ne soint pas appropriées pour des mesures de niveau de pression acoustique de crête. Les valeurs par bandes d'octave, H, M, L ou SNR conviennent pour établir des critères d'affaiblissement acoustique qui serviront à sélectionner ou à comparer les protecteurs individuels contre le bruit et/ou à établir des exigences minimales acceptables pour l'affaiblissement acoustique.

General Information

Status
Published
Publication Date
03-Oct-2018
Current Stage
9060 - Close of review
Start Date
04-Jun-2029
Ref Project

Relations

Buy Standard

Standard
ISO 4869-2:2018 - Acoustics -- Hearing protectors
English language
18 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 4869-2:2018 - Acoustique -- Protecteurs individuels contre le bruit
French language
18 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

INTERNATIONAL ISO
STANDARD 4869-2
Second edition
2018-10
Acoustics — Hearing protectors —
Part 2:
Estimation of effective A-weighted
sound pressure levels when hearing
protectors are worn
Acoustique — Protecteurs individuels contre le bruit —
Partie 2: Estimation des niveaux de pression acoustique pondérés A en
cas d'utilisation de protecteurs individuels contre le bruit
Reference number
ISO 4869-2:2018(E)
©
ISO 2018

---------------------- Page: 1 ----------------------
ISO 4869-2:2018(E)

COPYRIGHT PROTECTED DOCUMENT
© ISO 2018
All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may
be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting
on the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address
below or ISO’s member body in the country of the requester.
ISO copyright office
CP 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Fax: +41 22 749 09 47
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland
ii © ISO 2018 – All rights reserved

---------------------- Page: 2 ----------------------
ISO 4869-2:2018(E)

Contents Page
Foreword .iv
Introduction .v
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 Measurement of sound attenuation of hearing protectors . 2
5 Calculation of the assumed protection value, APV , of a hearing protector for a
fx
selected protection performance . 2
6 Octave-band method. 3
7 HML method . 4
7.1 General . 4
7.2 Calculation of H, M and L values . 4
7.3 Application of HML method for estimation of the effective A-weighted sound
pressure level . 6
8 SNR method . 6
8.1 General . 6
8.2 Calculation of SNR values . 6
8.3 Application of SNR method for estimation of the effective A-weighted sound
pressure level . 7
Annex A (informative) Example of the calculation of the assumed protection values, APV .
...

NORME ISO
INTERNATIONALE 4869-2
Deuxième édition
2018-10
Acoustique — Protecteurs individuels
contre le bruit —
Partie 2:
Estimation des niveaux de
pression acoustique pondérés A
en cas d'utilisation de protecteurs
individuels contre le bruit
Acoustics — Hearing protectors —
Part 2: Estimation of effective A-weighted sound pressure levels when
hearing protectors are worn
Numéro de référence
ISO 4869-2:2018(F)
©
ISO 2018

---------------------- Page: 1 ----------------------
ISO 4869-2:2018(F)

DOCUMENT PROTÉGÉ PAR COPYRIGHT
© ISO 2018
Tous droits réservés. Sauf prescription différente ou nécessité dans le contexte de sa mise en œuvre, aucune partie de cette
publication ne peut être reproduite ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique,
y compris la photocopie, ou la diffusion sur l’internet ou sur un intranet, sans autorisation écrite préalable. Une autorisation peut
être demandée à l’ISO à l’adresse ci-après ou au comité membre de l’ISO dans le pays du demandeur.
ISO copyright office
Case postale 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Genève
Tél.: +41 22 749 01 11
Fax: +41 22 749 09 47
E-mail: copyright@iso.org
Web: www.iso.org
Publié en Suisse
ii © ISO 2018 – Tous droits réservés

---------------------- Page: 2 ----------------------
ISO 4869-2:2018(F)

Sommaire Page
Avant-propos .iv
Introduction .v
1 Domaine d'application . 1
2 Références normatives . 1
3 Termes et définitions . 1
4 Mesurage de l'affaiblissement acoustique des protecteurs individuels contre le bruit .3
5 Calcul de la valeur de protection estimée, APV , d’un protecteur individuel contre le
fx
bruit pour une efficacité de protection choisie . 3
6 Méthode par bande d'octave . 3
7 Méthode HML . 4
7.1 Généralités . 4
7.2 Calcul des valeurs H, M et L .4
7.3 Application de la méthode HML pour l'estimation du niveau de pression
acoustique effectif pondéré A . 6
8 Méthode SNR . 7
8.1 Généralités . 7
8.2 Calcul des valeurs de SNR .7
8.3 Application de la méthode SNR pour l'estimation du niveau de pression
acoustique effectif pondéré A . 8
Annexe A (informative) Exemple de calcul des valeurs de protection estimées, APV .9
fx
Annexe B (informative) Exemple de calcul de L′ selon la méthode par bande d'octave .
...

Questions, Comments and Discussion