Glass in building - Painted glass for internal use - Part 2: Evaluation of conformity/Product standard

This European Standard covers the evaluation of conformity and the factory production control of painted glass for internal use in buildings.
Note   For glass products with electrical wiring or connections for, e.g. alarm or heating purposes, other directives, e.g. Low Voltage Directive, may apply.

Glas im Bauwesen - Farbiges Glas für den Innenbereich - Teil 2: Konformitätsbewertung/Produktnorm

Diese Europäische Norm behandelt die Konformitätsbewertung und die werkseigene Produktionskontrolle von farbigem Flachglas für den Innenbereich von Gebäuden.
Anmerkung   Für Glaserzeugnisse mit elektrischer/-n Verkabelung oder Anschlüssen, z. B. für Alarm- oder Heizungsanlagen, können andere Richtlinien, z. B. die Niederspannungsrichtlinie, gelten.

Verre dans la construction - Verre peint pour usage interieur - Partie 2 : Evaluation de la conformité/Norme de produit

La présente Norme européenne spécifie l’évaluation de la conformité et le contrôle de la production en usine du verre laqué destiné à un usage à l’intérieur des bâtiments.
NOTE   Pour les produits verriers équipés d’un câblage ou de branchements électriques, par exemple pour les alarmes ou le chauffage, d’autres directives, notamment la Directive Basse tension, peuvent s’appliquer.

Steklo v gradbeništvu - Poslikano steklo za interno uporabo - 2. del: Vrednotenje skladnosti/Standard za proizvod TC: Steklo v gradbeništvu - Barvano/Pobarvano steklo...

General Information

Status
Not Published
Public Enquiry End Date
08-Sep-2016
Current Stage
5520 - Unique Acceptance Procedure (UAP) (Adopted Project)
Start Date
20-Jun-2016
Due Date
07-Nov-2016
Completion Date
25-Oct-2016

Buy Standard

Draft
k FprEN 16477-2:2016
English language
30 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Steklo v gradbeništvu - Poslikano steklo za interno uporabo - 2. del: Vrednotenje skladnosti/Standard za proizvodGlas im Bauwesen - Teil 2: Konformitätsbewertung/ProduktnormVerre dans la construction - Verre peint pour usage interieur - Partie 2 : Evaluation de la conformité/Norme de produitGlass in building - Painted glass for internal use - Part 2: Evaluation of conformity/Product standard81.040.20Steklo v gradbeništvuGlass in buildingICS:Ta slovenski standard je istoveten z:FprEN 16477-2kSIST FprEN 16477-2:2016en,fr,de01-september-2016kSIST FprEN 16477-2:2016SLOVENSKI
STANDARD



kSIST FprEN 16477-2:2016



EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
FINAL DRAFT
FprEN 16477-2
June
t r s x ICS
z sä r v rä t r English Version
Glass in building æ Painted glass for internal use æ Part
tã Verre dans la construction æ Verre peint pour usage interieur æ Partie
t ã Evaluation de la
Glas im Bauwesen æ Teil
tã This draft European Standard is submitted to CEN members for unique acceptance procedureä It has been drawn up by the
If this draft becomes a European Standardá CEN members are bounwhich stipulate the conditions for giving this European Standard the status of a national standard without any alterationä
This draft European Standard was established by CEN in three ofer language made by translation under the responsibility of a CEN member into its own language and notified to the CENæCENELEC Management Centre has the same status as the official versionsä
CEN members are the national standards bodies of Austriaá Belgiumá Bulgariaá Croatiaá Cyprusá Czech Republicá Denmarká Estoniaá Finlandá Former Yugoslav Republic of Macedoniaá Franceá Germanyá Greeceá Hungaryá Icelandá Irelandá Italyá Latviaá Lithuaniaá Luxembourgá Maltaá Netherlandsá Norwayá Polandá Portugalá Romaniaá Slovakiaá Sloveniaá Spainá Swedená Switzerlandá Turkey andUnited Kingdomä
Recipients of this draft are invited to submitá with their commentsá notification of any relevant patent rights of which they are aware and to provide supporting documentationä
Warning ã This document is not a European Standardä It is distributed for review and commentsä It is subject to change without notice and shall not be referred to as a European Standardä
EUROPEAN COMMITTEE FOR STANDARDIZATION COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre:
Avenue Marnix 17,
B-1000 Brussels
9
t r s x CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Membersä Refä Noä FprEN
s x v y yæ tã t r s x EkSIST FprEN 16477-2:2016



FprEN 16477-2:2016 (E) 2 Contents Page European foreword .4 1 Scope .5 2 Normative references .5 3 Terms and definitions .6 4 Requirements .7 4.1 Product description .7 4.2 Determination of the characteristic’s performances .8 4.2.1 Characteristics of painted glass .8 4.2.2 Determination of characteristics of painted glass .8 4.3 Characteristics other than listed in 4.2 . 12 4.4 Dangerous substances . 12 5 Assessment and verification of constancy of performance – AVCP . 12 5.1 General . 12 5.2 Determination of the product type (see 5.1, 1) . 12 5.2.1 General . 12 5.2.2 Type testing of characteristic’s performances . 13 5.2.3 Test report . 13 5.2.4 Multiple lines/sites . 14 5.3 Factory production control (FPC) . 14 5.3.1 General . 14 5.3.2 Inspection of samples in accordance with the prescribed test plan (see 5.1, 2a) . 14 5.4 Initial inspection of factory and of factory production control (see 5.1, 2b) . 15 5.5 Continuous surveillance and assessment of the factory production control (see 5.1, 2c) . 16 5.6 Procedure for modifications . 17 5.7 Pre-production products (e.g. prototypes) . 17 6 Marking and/or labelling . 18 6.1 General . 18 6.2 Product marking . 18 Annex A (normative)
Factory production control . 19 A.1 Factory Production Control Requirements. 19 A.1.1 General . 19 A.1.2 Organization . 19 A.1.2.1 Responsibility and authority . 19 A.1.2.2 Management representative for factory production control . 19 A.1.2.3 Management review . 19 A.1.3 Control system. 19 A.1.3.1 General . 19 kSIST FprEN 16477-2:2016



FprEN 16477-2:2016 (E) 3 A.1.3.2 Personnel . 19 A.1.3.3 Documentation . 20 A.1.4 Equipment. 20 A.1.4.1 Testing . 20 A.1.4.2 Manufacturing . 20 A.1.5 Inspection and testing . 20 A.1.6 Non-complying materials/products . 20 A.2 Inspection and testing tables of painted glass product production . 21 A.2.1 Information on Table A.1 . 21 A.2.2 Use of proxy testing . 21 Annex B (informative)
Tests for factory production control . 24 Annex C (informative)
Provisions for voluntary involvement of third party(ies) . 25 C.1 General . 25 C.2 Voluntary tasks for third parties . 25 C.3 Marking and labelling . 25 Annex ZA (informative) Relationship of this European Standard with Regulation (EU) No.305/2011 . 26 ZA.1 Scope and relevant characteristics . 26 ZA.2 System of Assessment and Verification of Constancy of Performance (AVCP) . 27 ZA.3 Assignment of AVCP tasks . 27 Bibliography . 30
kSIST FprEN 16477-2:2016



FprEN 16477-2:2016 (E) 4 European foreword This document (FprEN 16477-2:2016) has been prepared by Technical Committee CEN/TC 129 “Glass in building”, the secretariat of which is held by NBN. This document is currently submitted to the Unique Acceptance Procedure. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s). For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of this document. This Part of the European Standard does not stand alone, it is a part of one standard: — EN 16477-1: Glass in building – Painted glass for internal use – Part 1: Definitions, requirements and tests methods — EN 16477-2: Glass in building – Painted glass for internal use – Part 2: Evaluation of conformity/Product standard This European Standard contains other aspects of importance of trade. kSIST FprEN 16477-2:2016



FprEN 16477-2:2016 (E) 5 1 Scope This European Standard covers the evaluation of conformity and the factory production control of painted glass for internal use in buildings. NOTE For glass products with electrical wiring or connections for, e.g. alarm or heating purposes, other directives, e.g. Low Voltage Directive, may apply. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 356, Glass in building - Security glazing - Testing and classification of resistance against manual attack EN 410, Glass in building - Determination of luminous and solar characteristics of glazing EN 673, Glass in building - Determination of thermal transmittance (U value) - Calculation method EN 1063, Glass in building - Security glazing - Testing and classification of resistance against bullet attack EN 12600, Glass in building - Pendulum test - Impact test method and classification for flat glass EN 12758, Glass in building - Glazing and airborne sound insulation - Product descriptions and determination of properties EN 12898, Glass in building - Determination of the emissivity EN 13501-1, Fire classification of construction products and building elements – Part 1: Classification using data from reaction to fire tests EN 13501-2, Fire classification of construction products and building elements – Part 2: Classification using data from resistance to fire tests excluding ventilation services EN 13501-5, Fire classification of construction products and building elements – Part 5: Classification using data from fire exposure roof tests EN 13541, Glass in building - Security glazing - Testing and classification of resistance against explosion pressure EN 15998, Glass in building - Safety in case of fire, fire resistance - Glass testing methodology for the purpose of classification FprEN 16477-1:2016, Glass in building – Painted glass for internal use – Part 1: Definitions, requirements and tests methods prEN 16612, Glass in building - Determination of the load resistance of glass panes by calculation and testing kSIST FprEN 16477-2:2016



FprEN 16477-2:2016 (E) 6 3 Terms and definitions For the purposes of this document, the terms and definitions in FprEN 16477-1:2016 and the following apply. 3.1 factory production control FPC documented, permanent and internal control of production in a factory, in accordance with this standard Note 1 to entry: See also Annexes A and B. 3.2 product-type set of representative performance levels or classes of a construction product, in relation to its essential characteristics, produced using a given combination of raw materials or other elements in a specific production process 3.3 essential characteristic characteristic of the construction product which relate to the basic requirements for construction works Note 1 to entry: Basic requirements for construction work are given in the regulation (EU) No 305/2011, Annex I. 3.4 performance of a construction product performance related to the relevant essential characteristics, expressed by level or class, or in a description 3.5 level result of the assessment of the performance of a construction product in relation to its essential characteristics, expressed as a numerical value 3.6 class range of levels, delimited by a minimum and a maximum value, of performance of a construction product 3.7 type testing TT determination of the performance of a product (characteristic, durability), on the basis of either actual tests or other procedures (such as conventional, standardised, tabulated or general accepted values, standardised or recognised calculation methods, test reports when made available, …), in accordance with this document and that demonstrates compliance with this European standard kSIST FprEN 16477-2:2016



FprEN 16477-2:2016 (E) 7 3.8 test report document that covers the results of tests undertaken on a representative sample of the product from production or on a prototype design of the product 3.9 product description document that details the relevant parameters, e.g. process conditions, structure, type and subtype of interlayer, type of glasses etc., for defining a product that complies with the standard and that includes specific reference(s) to characteristics that are modified by the production process 3.10 product family group of products determined by the manufacturer, which is made with similar components and which is tested for TT/FPC using the same test method 3.11 significant change variation in performance beyond the permitted tolerance for the characteristic which is not covered by substitution rules 4 Requirements 4.1 Product description For conformity purposes the painted glass manufacturer is responsible for the preparation and maintenance of the product description. This description shall describe the product and/or product families. Disclosure of the product description shall be at the discretion of the painted glass manufacturer or his agent except in the case of regulatory requirements. The product description shall contain at least the following: — reference to EN 16477 Parts 1 and 2 and all other standards with which the manufacturer claims compliance. — materials making up the layers of the painted glass. — glass substrates The layers may be listed either in full, i.e. chemical composition, or by manufacturers’ code. The definition of product families shall be consistent with the product description. The substitution of materials shall maintain the conformity with the product description. The substituting material can be added to the product description when compliance has been demonstrated. kSIST FprEN 16477-2:2016



FprEN 16477-2:2016 (E) 8 4.2 Determination of the characteristic’s performances 4.2.1 Characteristics of painted glass 4.2.1.1 General The characteristics of painted glass, listed in Table 1, are those of the glass substrate (see 4.2.1.2). Since they are not changed significantly by the painting process, they shall be used for painted glass. For glass substrates covered by Harmonized European specifications, generally accepted values, declared values, or calculated values of the characteristics listed in Table 1 shall be used. if glass panes are used which are not covered by Harmonized European Specifications (as defined in regulation EU 305/2011), it shall be demonstrated that those glasses have a chemical composition and a mechanical stability over time equivalent to the requirements of the relevant standard listed. Table 1 — Characteristics of glass components Characteristic Symbol Unit Density
kg/m3 Hardness (Knoop hardness in accordance with ISO 9385) HK0,1/20 Dimensionless Young's modulus E GPa Poisson's ratio
Dimensionless Characteristic bending strength ƒg, k MPa Resistance against sudden temperature changes and temperature differentials
K Specific heat capacity c J/(kg.K) Coefficient of linear expansion l K «1 Thermal conductivity
W/(m.K) Mean refractive index to visible radiation n Dimensionless 4.2.1.2 Glass panes used as components for the production of laminated and laminated safety glass The glass substrate listed in FprEN 16477-1:2016, Clause 4 may be used for the production of painted glass. 4.2.2 Determination of characteristics of painted glass 4.2.2.1 General If the painted glass manufacturer wishes to claim that any performance characteristic is independent of the production equipment used then the factory production control system shall be in accordance with this standard including his specific process control conditions. kSIST FprEN 16477-2:2016



FprEN 16477-2:2016 (E) 9 4.2.2.2 Safety in the case of fire - Resistance to fire Fire resistance shall be determined and classified in accordance with EN 13501-2. EN 15998 specifies the testing methodology to be used for glass products that are claiming fire resistance. 4.2.2.3 Safety in the case of fire - Reaction to fire Reaction to fire shall be determined and classified in accordance with EN 13501-1. CEN/TS 15117:2005, 6.3, specifies that if the painted glass is applied on a non-combustible substrate (e.g. wall) the paint is considered as an internal non substantial component and A1 criteria may be applied. When the PCS of the paint component of the painted glass does not exceed 1,4 MJ/m2, Painted glass are products/materials that may be classified A1 following EN 13501-1. When the PCS of the paint component of the painted glass does not exceed 4 MJ/m2, Painted glass are products/materials that may be classified A2 following EN 13501-1. NOTE 1 PCS (gross calorific potential, MJ/kg or MJ/m2) is evaluated following EN ISO 1716. NOTE 2 The undertaking of PCS determination can be unnecessary if test report according to EN ISO 1716 are supplied by paint supplier If the application is not against a non-combustible substrate (e.g; wall) the paint is considered as an external non substantial component and a general classification according to EN 13501-1 applies. An increase of glass thickness will not adversely affect the classification with respect to reaction to fire and do not require a new type test. 4.2.2.4 Safety in the case of fire - External fire behaviour (for roof coverings only) Where the manufacturer wishes to declare external fire performance (e.g. when subject to regulatory requirements), the product shall be tested in accordance with EN 13501-5. 4.2.2.5 Safety in use - Bullet resistance: shatter properties and resistance to attack Bullet resistance shall be determined and classified in accordance with EN 1063. 4.2.2.6 Safety in use - Explosion resistance: impact behaviour and resistance to impact Explosion resistance shall be determined and classified in accordance with EN 13541. 4.2.2.7 Safety in use - Burglar resistance: shatter properties and resistance to attack Burglar resistance shall be determined and classified in accordance with EN 356. 4.2.2.8 Safety in use - Pendulum body impact resistance: shatter properties (safe breakability) and resistance to impact Pendulum body impact resistance shall be determined and classified in accordance with EN 12600. kSIST FprEN 16477-2:2016



FprEN 16477-2:2016 (E) 10 4.2.2.9 Safety in use - Mechanical resistance: Resistance against sudden temperature changes and temperature differentials The resistance against sudden temperature changes and temperature differentials is a generally accepted value that is given in the relevant glass substrate standard and shall be ensured by compliance with this standard. 4.2.2.10 Safety in use - Mechanical resistance: Resistance against wind, snow, permanent load and/or imposed loads of the glass unit The mechanical resistance of painted glass is a characteristic value that shall be ensured by compliance with this standard. The value to be declared is the characteristic bending strength as defined in the relevant product standard of the glass substrate. As long as on the concerned construction or building site prEN 16612 is not applicable for the design then the current method of determining mechanical resistance in the country of destination shall be applied. 4.2.2.11 Protection against noise - Direct airborne sound reduction The sound reduction indexes shall be determined in accordance with EN 12758. However, the information supplied with the incoming glass can be used as the painted glass production process does not alter the values. 4.2.2.12 Energy conservation and heat retention - Thermal properties The thermal transmittance value (U-value) shall be determined by calculation in accordance with EN 673 with: — Normal available, the emissivity shall be determined in accordance with EN 12898. — nominal thickness of the glass panes 4.2.2.13 Energy conservation and heat retention - Radiation properties: Light transmittance and reflectance The light transmittance and reflectance shall be determined in accordance with EN 410. 4.2.2.14 Energy conservation and heat retention - Radiation properties: Solar energy characteristics The solar direct transmittance, the solar direct reflectance and the total solar energy transmittance (solar factor or g-value) shall be determined in accordance with EN 410. 4.2.2.15 Durability / Type of painted glass Products shall conform to the definition, to the manufacturer’s product description and fulfil the requirements of painted glass. The type testing concerns the product aspects as listed in Table 2. kSIST FprEN 16477-2:2016



FprEN 16477-2:2016 (E) 11 Table 2 — Durability tests of painted glass Product type Tests Clause of FprEN 16477-1:2016 Designation Painted glass Class A - High humidity - High temperature - radiation -adhesion - 8.1.3.4.1 - 8.1.4.3.1 - 8.1.5.4.1 - 8.2 A Painted glass class B - High humidity - High temperature - radiation -adhesion - 8.1.3.4.2 - 8.1.4.3.2 - 8.1.5.4.2 - 8.2 B When products conform to the definition of painted glass then the characteristics’ performances in 4.2 are ensured during an economically reasonable working life. The durability/conformity of glass products, including their characteristics, is ensured by the following: — Compliance with this standard — Compliance with instructions from the glass product manufacturer or supplier The manufacturer shall supply specific installation instructions or make reference to appropriate technical specifications. NOTE
Also the durability of glass products depends on: — building and construction movements due to various actions; — building and construction vibrations due to various actions; — deflection and racking of the glass support due to various actions; — glass support design (e.g. drainage of infiltrated water in the rebate, prevention of direct contact between glass support members and glass); — accuracy of glass support and glass support member dimensions; — quality of the assembling of glass support members up to a glass support; — quality of installation of the glass support into or onto the buildings or constructions; — glass support expansion due to adsorbed moisture from the air or other sources; — the quality of installation of the glass product into or onto its support. kSIST FprEN 16477-2:2016



FprEN 16477-2:2016 (E) 12 4.3 Characteristics other than listed in 4.2 Visual characteristics shall comply with FprEN 16477-1:2016. Dimensional tolerances shall comply with FprEN 16477-1:2016. 4.4 Dangerous substances National regulations on dangerous substances may require verification and declaration on release, and sometimes content, when construction products covered by this standard are placed on those markets. In the absence of European harmonized test methods, verification and declaration on release/content should be done taking into account national provisions in the place of use. NOTE An informative database covering European and national provisions on dangerous substances is available at the Construction website on EUROPA accessed through: http://ec.europa.eu/enterprise/construction/cpd-ds/ 5 Assessment and verification of constancy of performance – AVCP 5.1 General The compliance of painted glass with the requirements of this standard and with the performances declared by the manufacturer in the declaration of performances shall be demonstrated by: 1) Determination of the product type 2) Factory production control by the manufacturer, including product assessment; This shall include the following: a) inspection of samples taken at the factory in accordance with a prescribed test plan; b) initial inspection of the factory and of factory production control; c) continuous surveillance and assessment of the factory production control. The manufacturer shall always retain the overall control and shall have the necessary means to take responsibility for the conformity of the product with its declared performance(s). NOTE The assignment of tasks to the notified body(ies) and the manufacturer is shown in Annex ZA, Table ZA.3. 5.2 Determination of the product type (see 5.1, 1) 5.2.1 General All performances related to characteristics included in this standard shall be determined when the manufacturer intends to declare the respective performances. In addition instead of performing any actual testing, type testing may make use of: — generally accepted and/or conventional and/or standardised values, in the Clause 2 referenced standards, or in publications that are referred to in these standards; kSIST FprEN 16477-2:2016



FprEN 16477-2:2016 (E) 13 — standardised calculation methods and recognized calculation methods in the Clause 2 referenced standards, or in publications that are referred to in these standards; — assessment previously performed in accordance with the provisions of this standard (i.e. historic data) may be taken into account provided that they were made to the same or a more rigorous test method, under the same AVCP system (see NOTE 1) on the same product or products of similar design, construction and functionality, such that the results are applicable to the product in question; — where components are used whose characteristics have already been determined, by the component manufacturer, on the basis of conformity with other product standards, these characteristics need not be reassessed providing they remain unchanged by the manufacturing process (see note 2); — release of dangerous substances may be assessed indirectly by controlling the amount of the substance concerned; — durability / conformity may be assessed indirectly by controlling the production processes according to this document. NOTE 1 AVCP systems were called Attestation of Conformity (AoC) systems under the EU Construction Products Directive (89/106/EEC). NOTE 2 Products CE marked in accordance with appropriate harmonized European s
...