Gas-fired domestic appliances producing hot water - Part 5: Assessment of energy consumption of gas fired appliances combined with electrical heat pump

This European Standard is applicable to gas-fired appliances producing domestic hot water. It applies to both
instantaneous and storage gas-fired appliances combined with electrical heat pump.
It applies to a package marketed as single unit or fully specified by a manufacturer that have:
- a gas heat input not exceeding 70 kW;
- a hot water storage capacity not exceeding 500 litres.
Standard EN 13203-1 sets out in qualitative and quantitative terms the performance in delivery of domestic
hot water for a selected variety of uses. It also gives a system for presenting the information to the user. This
Part 5 sets out a method for assessing the energy performance of gas fired appliances combined with heat
pump with electrically driven compressor according to EN 16147.
This European standard does not apply for gas boilers with recovery systems using combustion products as
heat source for the electrical heat pump.
When the electrical heat pump does not work for domestic hot water production in the summer period, the
present standard is not applicable for energy performances assessing, EN 13203-2 must be used.

Gasbeheizte Geräte für die sanitäre Warmwasserbereitung für den Hausgebrauch - Teil 5: Bewertung des Energieverbrauchs von Gasgeräten mit elektrischer Wärmepumpe

Appareils domestiques produisant de l'eau chaude sanitaire utilisant les combustibles gazeux - Partie 5 : Evaluation de la consommation énergétique des appareils à gaz combinés à une pompe à chaleur électrique

La présente Norme européenne est applicable aux appareils de production d’eau chaude sanitaire utilisant les combustibles gazeux. Elle s’applique à la fois aux appareils instantanés et à accumulation utilisant les combustibles gazeux, combinés à une pompe à chaleur électrique.
Elle s’applique à un ensemble commercialisé comme une seule unité ou entièrement spécifié par le fabricant, qui a :
- un débit calorifique inférieur ou égal à 400 kW ; et
- une capacité du ballon d’eau chaude (le cas échéant) inférieure ou égale à 2 000 l.
L’EN 13203-1 définit, en termes qualitatifs et quantitatifs, la performance en puisage d’eau chaude sanitaire pour une variété d’usages sélectionnée. Elle mentionne également un système pour présenter les informations à l’utilisateur. Le présent document définit une méthode pour évaluer les performances énergétiques des appareils utilisant les combustibles gazeux, combinés à une pompe à
chaleur équipée d’un compresseur entrainé par moteur électrique conformément à l’EN 16147. Elle définit différents profils de soutirage journaliers pour chaque utilisation d’eau chaude sanitaire, pour la cuisine, la douche, le bain et une combinaison de ces utilisations, ainsi que les modes opératoires d’essai correspondants, ce qui permet de comparer les performances énergétiques des différents appareils utilisant les combustibles gazeux et de les adapter aux besoins de l’utilisateur. Des parties spécifiques de l’EN 13203 s’appliquent lorsque d’autres technologies sont associées à une chaudière ou un chauffe-eau utilisant les combustibles gazeux pour produire de l’eau chaude sanitaire.
Le présent document ne s’applique pas aux chaudières à gaz équipées de systèmes de récupération utilisant les produits de combustion comme source thermique pour la pompe à chaleur électrique.
Lorsque la pompe à chaleur électrique ne fonctionne pas pour produire de l’eau chaude sanitaire en régime été, la présente norme n’est pas applicable pour l’évaluation des performances énergétiques et il convient alors d’utiliser l’EN 13203-2.

Plinske gospodinjske naprave za pripravo tople sanitarne vode - 5. del: Ocenjevanje rabe energije plinskih aparatov, kombiniranih z električno toplotno črpalko

Ta evropski standard se uporablja za plinske gospodinjske naprave za pripravo tople sanitarne vode. Uporablja se za pretočne ali shranjevalne plinske gospodinjske naprave v kombinaciji z električno toplotno črpalko. To velja za vse naprave, ki so na trgu na voljo kot samostojna enota ali kot paket in pri katerih po navedbah proizvajalca: – vhodna toplota plina ne presega 70 kW; – zmogljivost skladiščenja tople vode ne presega 500 litrov. Standard EN 13203-1 v kakovostnem in količinskem smislu določa zmogljivost za pripravo tople sanitarne vode za različne izbrane namene. Zajema tudi sistem za predstavitev informacij uporabniku. Ta 5. del določa metodo za ocenjevanje energetske učinkovitosti plinskih naprav, kombiniranih s toplotno črpalko z električnim kompresorjem v skladu s standardom EN 16147. Ta evropski standard se ne uporablja za plinske kotle z rekuperacijskimi sistemi, ki kot vir toplote za električno toplotno črpalko uporabljajo produkte zgorevanja. Kadar električna toplotna črpalka ne deluje za pripravo tople sanitarne vode v poletnem obdobju, se za ocenjevanje energetskih lastnosti ne uporablja ta standard; uporabiti je treba standard EN 13203-2.

General Information

Status
Withdrawn
Public Enquiry End Date
04-Apr-2018
Publication Date
12-Mar-2019
Withdrawal Date
13-Nov-2022
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
08-Nov-2022
Due Date
01-Dec-2022
Completion Date
14-Nov-2022

Relations

Buy Standard

Standard
EN 13203-5:2019 - BARVE
English language
51 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day
Draft
k FprEN 13203-5:2015
English language
49 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day
Draft
k FprEN 13203-5:2018
English language
52 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 13203-5:2019
01-april-2019
3OLQVNHJRVSRGLQMVNHQDSUDYH]DSULSUDYRWRSOHVDQLWDUQHYRGHGHO
2FHQMHYDQMH]PRJOMLYRVWLUDEHHQHUJLMHSOLQVNLKDSDUDWRYNRPELQLUDQLK]
HOHNWULþQRWRSORWQRþUSDONR
Gas-fired domestic appliances producing hot water - Part 5: Assessment of energy
consumption of gas fired appliances combined with electrical heat pump
Gasbeheizte Geräte für die sanitäre Warmwasserbereitung für den Hausgebrauch - Teil
5: Bewertung des Energieverbrauchs von Gasgeräten mit elektrischer Wärmepumpe
Appareils domestiques produisant de l'eau chaude sanitaire utilisant les combustibles
gazeux - Partie 5 : Evaluation de la consommation énergétique des appareils à gaz
combinés à une pompe à chaleur électrique
Ta slovenski standard je istoveten z: EN 13203-5:2018
ICS:
27.080 7RSORWQHþUSDONH Heat pumps
91.140.65 Oprema za ogrevanje vode Water heating equipment
SIST EN 13203-5:2019 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 13203-5:2019

---------------------- Page: 2 ----------------------

SIST EN 13203-5:2019


EN 13203-5
EUROPEAN STANDARD

NORME EUROPÉENNE

December 2018
EUROPÄISCHE NORM
ICS 91.140.65
English Version

Gas-fired domestic appliances producing hot water - Part
5: Assessment of energy consumption of gas fired
appliances combined with electrical heat pump
Appareils domestiques produisant de l'eau chaude Gasbeheizte Geräte für die sanitäre
sanitaire utilisant les combustibles gazeux - Partie 5 : Warmwasserbereitung für den Hausgebrauch - Teil 5:
Évaluation de la consommation énergétique des Bewertung des Energieverbrauchs von Gasgeräten mit
appareils utilisant les combustibles gazeux combinés à elektrischer Wärmepumpe
une pompe à chaleur électrique
This European Standard was approved by CEN on 27 May 2018.

CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.

This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and United Kingdom.





EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2018 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 13203-5:2018 E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------

SIST EN 13203-5:2019
EN 13203-5:2018 (E)
Contents Page
European foreword . 4
Introduction . 5
1 Scope . 6
2 Normative references . 6
3 Terms and definitions . 6
4 General test conditions . 9
4.1 Reference conditions . 9
4.2 Specific heat source temperature conditions . 9
4.3 Measurement uncertainties . 10
4.3.1 General . 10
4.3.2 Steady-state conditions . 11
4.4 Test conditions . 11
4.4.1 General . 11
4.4.2 Test room . 11
4.4.3 Water supply . 12
4.4.4 Initial adjustment of the appliance . 12
4.4.5 Conditions for the determination of the maximum load profile . 13
4.4.6 Electrical supply . 13
5 Determination of the energy consumption of the appliance . 13
5.1 General . 13
5.2 Load profiles . 13
5.3 Determination of the energy recovered by the useful water . 21
5.4 Calculation of gas energy . 22
5.4.1 Calculation of daily gas energy consumption in summer mode . 22
5.5 Calculation of electrical energy . 22
5.5.1 Calculation of daily electrical energy consumption . 22
5.6 Corrections to apply for fans and liquid pumps . 23
5.6.1 Power absorbed by the fans of connected heat pumps . 23
5.6.2 Power absorbed by liquid pumps . 24
5.7 Measurement of energy consumption in standby mode . 24
5.7.1 General . 24
5.7.2 Calculation of daily gas energy consumption in standby mode . 25
5.7.3 Calculation of daily auxiliary electrical energy consumption in standby mode . 25
5.8 Determination of daily auxiliary electrical energy consumption in off mode . 26
6 Determination of the ratio of wasted water to total water . 26
7 Eco design Related Products Data . 27
7.1 Water heating energy efficiency . 27
7.2 Annual fuel consumption (AFC) . 28
7.3 Annual electricity consumption (AEC) . 28
7.4 Mixed water at 40°C (V40) for storage water heaters . 29
Annex A (informative)  Test conditions . 30
Annex B (informative) Test rig and measurement devices . 34
2

---------------------- Page: 4 ----------------------

SIST EN 13203-5:2019
EN 13203-5:2018 (E)
B.1 General. 34
B.2 Pressure measurement. 34
B.3 Temperature measurement . 35
Annex C (informative) Declaration of the Maximum Load Profile . 38
Annex D (informative)  Packages covered by the present document . 39
Annex E (informative) Additional performance data . 44
E.1 Heating time. 44
E.2 Standby power input . 44
E.3 Coefficient of primary energy performance or primary energy yield (PER) . 45
E.4 Total consumption of primary energy . 45
Annex ZA (informative) Relationship between this European Standard and the ecodesign
requirements of Commission Regulation (EU) n° 814/2013 [OJEU L239 of 6 September
2013] aimed to be covered . 47
Annex ZB (informative) Relationship between this European Standard and the energy labelling
requirements of Commission Delegated Regulation (EU) No 812/2013 [OJEU L239 of 6
September 2013] aimed to be covered . 48
Annex ZC (informative) Relationship between this European Standard and the ecodesign
requirements of Commission Regulation (EU) n° 813/2013 [OJEU L239 of 6 September
2013] aimed to be covered . 49
Annex ZD (informative) Relationship between this European Standard and the energy labelling
requirements of Commission Delegated Regulation (EU) No 811/2013 [OJEU L239 of 6
September 2013] aimed to be covered . 50
Bibliography . 51

3

---------------------- Page: 5 ----------------------

SIST EN 13203-5:2019
EN 13203-5:2018 (E)
European foreword
This document (EN 13203-5:2018) has been prepared by Technical Committee CEN/TC 109 “Central heating
boilers using gaseous fuels”, the secretariat of which is held by NEN.
This European Standard shall be given the status of a national standard, either by publication of an identical
text or by endorsement, at the latest by June 2019, and conflicting national standards shall be withdrawn at
the latest by June 2019.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. CEN shall not be held responsible for identifying any or all such patent rights.
This document has been prepared under a mandate given to CEN by the European Commission and the
European Free Trade Association, and supports essential requirements of EU Directive(s).
For relationship with EU Directive(s), see informative Annex ZA, ZB, ZC or ZD, which are integral parts of this
document.
The main purpose of this revision is to provide a means of conforming to requirements of Commission
Delegated Regulation (EC) n° 813/2013, (EC) n° 811/2013, (EC) n° 812/2013 and (EC) n° 814/2013.
According to the CEN-CENELEC Internal Regulations, the national standards organisations of the following
countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech
Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece,
Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,
Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.
4

---------------------- Page: 6 ----------------------

SIST EN 13203-5:2019
EN 13203-5:2018 (E)
Introduction
The safety operation of the boiler or water heater is not covered by this standard. Safety should be proved by
means of the essential safety requirements of the Gas Appliances Directive 2009/142/EC. This may be
achieved by compliance with the appropriate existing harmonized standards.
NOTE 1 Useful standards are EN 26, EN 89 and series EN 15502.
NOTE 2 The Gas Appliances Directive 2009/142/EC has been replaced by the Gas Appliances Regulation
426/2016/EU.
5

---------------------- Page: 7 ----------------------

SIST EN 13203-5:2019
EN 13203-5:2018 (E)
1 Scope
This European Standard is applicable to gas-fired appliances producing domestic hot water. It applies to both
instantaneous and storage gas-fired combined with electrical heat pump.
It applies to a package marketed as single unit or fully specified by the manufacturer that have:
— a heat input not exceeding 400 kW; and
— a hot water storage tank capacity (if any) not exceeding 2000 l.
EN 13203-1 sets out in qualitative and quantitative terms the performance in delivery of domestic hot water
for a selected variety of uses. It also gives a system for presenting the information to the user. The present
document sets out a method for assessing the energy performance of gas fired appliances combined with heat
pump with electrically driven compressor according to EN 16147. It defines a number of daily load profiles
for each domestic hot water use, kitchen, shower, bath and a combination of these, together with
corresponding test procedures, enabling the energy performances of different gas-fired appliances to be
compared and matched to the needs of the user. Where other technologies are combined with a gas-fired
boiler or a water heater to produce domestic hot water, specific parts of EN 13203 apply.
The present document does not apply for gas boilers with recovery systems using combustion products as
heat source for the electrical heat pump.
When the electrical heat pump does not work for domestic hot water production in the summer period, the
present standard is not applicable for energy performances assessing, EN 13203-2 should be used.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes
requirements of this document. For dated references, only the edition cited applies. For undated references,
the latest edition of the referenced document (including any amendments) applies.
EN 14511-3:2018, Air conditioners, liquid chilling packages and heat pumps with electrically driven
compressors for space heating and cooling - Part 3: Test methods
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
• IEC Electropedia: available at http://www.electropedia.org/
• ISO Online browsing platform: available at http://www.iso.org/obp
3.1
storage tank
reservoir for domestic hot water
3.2
nominal domestic hot water heat input of the boiler (Q )
nw
value of the heat input of the boiler for the production of domestic hot water stated in the instructions, the
symbol of which is Q and the unit of which is kilowatt (kW)
nw
6

---------------------- Page: 8 ----------------------

SIST EN 13203-5:2019
EN 13203-5:2018 (E)
3.3
summer mode
conditions during which the appliance supplies energy only for the production of domestic hot water
3.4
winter mode
conditions during which the combination boiler supplies energy for the production of domestic hot water and
space heating
3.5
domestic water test temperature
temperature of the delivered water at which the tests are conducted
3.6
control cycle
the time cycle for keeping components and/or the storage tank (if any) of the domestic hot water circuit at
predetermined temperature level, consists of an «ON» duration time during which the heating of the domestic
hot water (by gas energy and/or auxiliary energy) is operating, and an «OFF» duration time during which no
heating occurs
3.7
useful water
quantity of water delivered at the tap for which the temperature increase is in accordance with the
requirement fixed for each individual delivery of the load profiles
3.8
wasted water
quantity of water delivered at the tap for which the temperature increase is not in accordance with the
requirement fixed for each individual delivery of the load profiles
3.9
standby mode
operating state in which the appliance can provide domestic hot water at any time
Note 1 to entry: In the case of an appliance with a control cycle for keeping components and/or the storage tank (if
any) of the domestic hot water circuit at predetermined temperature level no draw-off is made.
3.10
off mode
state of an appliance, selected by the user, in which domestic hot water cannot be provided
3.11
useful water flow rate
D
useful
quantity of water delivered by unit time at the tap for which the temperature increase is in accordance with
the requirement fixed for each individual draw-off of the load profiles
3.12
useful water temperature
water temperature, expressed in degrees Celsius, delivered at the tap
3.13
appliance flow rate
quantity of water delivered by the appliance by unit time before the mixing device, if applicable
7

---------------------- Page: 9 ----------------------

SIST EN 13203-5:2019
EN 13203-5:2018 (E)
3.14
appliance water temperature
T
d
water temperature, expressed in degrees Celsius, delivered by the appliance before the mixing device
3.15
water temperature rise in K
∆T
m
difference between the useful water temperature and the cold water temperature, at which hot water is
contributing to the reference energy as specified in the load profiles
3.16
water temperature rise for basin draw-off types in K
∆T
p
difference between the useful water temperature and the cold water temperature, to be achieved during the
water draw-offs, with a minimum value as specified in the load profiles
Note 1 to entry: The minimum temperature difference for basin draw-offs as specified in the load profiles shall be
achieved at least during the water draw-offs.
3.17
rapid response temperature sensor
measuring instrument with a response time such that 90 % of the final temperature rise, from 15 °C to 100 °C,
is obtained within about 1 s, when the sensor is plunged into still water.
3.18
indoor air
heat source for a heat pump which absorbs heat by a heat exchanger in direct contact with the air inside a
building
3.19
brine
heat transfer medium which has a freezing point depressed relative to water
3.20
gas-fired appliance combined with electrical heat pump air/water
appliance which is either placed on the market or specified as a complete package to deliver domestic hot
water or domestic hot water and heating, comprising as relevant:
— electrical heat pump;
— gas-fired appliance;
— ducts if appropriate;
— thermal store.
3.21
exhaust air
air from the air conditioned space entering the outdoor heat exchanger
[EN 14511-1:2018, 3.22]
8

---------------------- Page: 10 ----------------------

SIST EN 13203-5:2019
EN 13203-5:2018 (E)
3.22
external static pressure difference
Δp
ext
positive pressure difference measured between the air (or water) outlet section and the air (or water) inlet
section of the unit, which is available for overcoming the pressure drop of any additional ducted air (or water)
circuit
3.23
internal static pressure difference
Δp
int
negative pressure difference measured between the air (or water) outlet section and the air (or water) inlet
section of the unit, which corresponds to the total pressure drop of all components on the air (or water) side
of the unit
4 General test conditions
4.1 Reference conditions
Unless otherwise stated, the general test conditions shall be as follows:
— cold water temperature: 10 °C;
— maximum average variation over the test period: ± 2 K;
— cold water pressure: (2 ± 0,1) bar;
— ambient air temperature: 20 °C;
— maximum average variation over the test period ± 2 K;
— maximum variation during the tests ± 2 K;
— electrical supply voltage: (230 ± 2) V (single phase) or (410 ± 4) V (three phase).
4.2 Specific heat source temperature conditions
The tests shall be carried out at the test conditions specified in Table 1 as appropriate.
9

---------------------- Page: 11 ----------------------

SIST EN 13203-5:2019
EN 13203-5:2018 (E)
Table 1 — Test conditions for particular types of systems
Type of heat source Heat source Range of ambient Ambient temperature
temperature (°C) temperature for heat of storage tank (°C)
pump
(°C)
Outside air (heat pump
7 ± 0,2 20 ± 3 20 ± 3
indoor) with air duct
 (6 ± 0,3)
Outside air (heat pump
a)
7 ± 0,2 20 ± 3
7 ± 3
outdoor)
 (6 ± 0,3)
a) a)
Exhaust air 20 ± 0,2
20 ± 3 20 ± 3
 (12 ± 0,3)
Water (inlet) 10 ± 0,15 20 ± 3 20 ± 3
Brine (inlet) 0 ± 0,15 20 ± 3 20 ± 3
Direct evaporation 4 ± 0,5 20 ± 3 20 ± 3
a)
In this case, the ambient temperature of the heat pump is the same as the temperature of the heat source. The
difference with EN 16147 is justified because of the possible installation of the appliance into a living room.
NOTE 1 All heat source temperatures are inlet temperatures in °C.
NOTE 2 All air temperatures in (brackets) are wet bulb temperatures in °C.
NOTE 3 Permissible external pressure difference or associated internal pressure difference at the outdoor heat
exchanger as stated in the installation and/or operation manual in Pascal (Pa) for appliances with duct
connection.
4.3 Measurement uncertainties
4.3.1 General
Except where otherwise stated in the clauses describing the tests, the uncertainties of measurements carried
out shall not be greater than the maximum uncertainties indicated below.
The standard deviations shall be evaluated taking into account the various sources of uncertainty:
contribution from the instrument, repeatability, calibration, ambient conditions, etc.
— water flow rate: ± 1 %;
— gas flow rate: ± 1 %;
— time: ± 0,2 s;
— temperatures:
— ambient: ± 1 K;
— air as heat source dry bulb temperature: ± 0,2 °C;
— air as heat source wet bulb temperature: ± 0,3 °C;
10

---------------------- Page: 12 ----------------------

SIST EN 13203-5:2019
EN 13203-5:2018 (E)
— water/brine as heat source: ± 0,15 K;
— water: ± 0,5 K;
— gas: ± 0,5 K;
— gas pressure: ± 1 %;
— gas calorific value: ± 1 %;
— gas density: ± 0,5 %;
— electrical energy: ± 2 %.
The stated measurement uncertainties relate to individual measurements. For measurements that combine a
number of individual measurements, smaller uncertainties on the individual measurements may be necessary
to ensure a total uncertainty within ± 2 % under the steady-state conditions as defined by 4.3.2.
These uncertainties correspond to two standard deviations (2σ).
4.3.2 Steady-state conditions
Steady-state operating conditions are regarded as established when the appliance operates for sufficient time
to reach thermal stabilization.
To reach the steady-state the water temperature at the outlet of the appliance shall not vary by more
than ± 0,5 K.
NOTE This condition can be reached with a gas which is different from the reference gas, provided that the
appliance is supplied with the reference gas for at least 5 min before the requirements are verified.
4.4 Test conditions
4.4.1 General
Except where otherwise stated, the appliance is tested under the following conditions.
The tests shall be carried out only in summer mode as defined in 3.3, and the appliance shall be set in summer
mode.
If liquid heat transfer media other than water are used, the specific heat capacity and density of such heat
transfer media shall be determined and taken into consideration in the evaluation.
For all tests defined by this standard, the same adjustment of the appliance shall be maintained.
The load profile used for the measurement shall be the one declared according to the technical instruction of
the appliance (see also Annex C).
The test shall be performed in the setting in which the appliance is delivered, and which is documented as
such in the technical instructions.
If there are temporary user's settings (automatically self-resetting within 24 h), these shall not be active.
4.4.2 Test room
The package shall be installed in a well-ventilated, draught-free room (air speed less than 0,5 m/s).
The package shall be protected from direct solar radiation and radiation from heat generators.
If the package incorporates an air source outdoor heat exchanger a further test room is needed. The size of
this test room shall be designed to avoid any resistance to air flow at the air inlet and air outlet orifices of the
11

---------------------- Page: 13 ----------------------

SIST EN 13203-5:2019
EN 13203-5:2018 (E)
test object. The air flow through this room shall not cause any short circuit between the two orifices, and
therefore the velocity of air flow at these two locations shall not exceed 1,5 m/s when the test object is
switched off. The air velocity in the room shall also not be greater than the mean velocity through the unit
inlet.
Unless otherwise stated in the technical documentation, the air inlet and air outlet orifices shall not be less
than 1m from the surfaces of the test room; this also applies to any measuring ducts.
The setting of the external static pressure difference on the air side for heat pumps with duct connection is
described by 4.4.1.4 of EN 14511-3:2018.
For heat pumps separated from the tank, the liquid flow rate has to be set on the liquid outlet side of the heat
pump to the nominal flow rate specified in the technical documentation.
The package shall be installed and connected for the test as specified in the installation instructions.
Temperature and pressure measuring points shall be situated in order to obtain significant mean values.
Set points for internal control equipment of the unit such as thermostats, pressure switches or mixing valves
shall be set to the values stated in the technical documentation.
Air and entrained gases shall be removed from all water and other heat transfer liquid systems
In the case of package incorporating a single split heat pump, the following installation conditions shall be
complied with for the tests:
a) each refrigerant pipe shall be installed in accordance with the installation instructions;
b) the connecting pipes shall be installed so that the difference in elevation does not exceed 2,5 m. The
length of each connecting pipe shall be between 5 m and 7,5 m;
c) thermal insulation shall be applied to the pipes in accordance with the installation instructions;
d) unless constrained by the design at least half of the interconnecting pipes shall be exposed to the outdoor
conditions with the rest of the pipes exposed to the indoor conditions.
For indirect systems each water pipe shall be installed in accordance with the installation instructions to the
maximum stated length or 5 m whichever is shorter. Thermal insulation shall be applied to the pipes in
accordance with the installation instructions.
4.4.3 Water supply
For the tests
...

SLOVENSKI STANDARD
kSIST FprEN 13203-5:2015
01-junij-2015
3OLQVNHJRVSRGLQMVNHNXULOQHQDSUDYH]DSULSUDYRWRSOHVDQLWDUQHYRGHGHO
2FHQMHYDQMHSRUDEHHQHUJLMHSOLQVNLKDSDUDWRYNRPELQLUDQLK]HOHNWULþQRWRSORWQR
þUSDONR
Gas-fired domestic appliances producing hot water - Part 5: Assessment of energy
consumption of gas fired appliances combined with electrical heat pump
Gasbeheizte Geräte für die sanitäre Warmwasserbereitung für den Hausgebrauch - Teil
5: Bewertung des Energieverbrauchs von Gasgeräten mit elektrischer Wärmepumpe
Appareils domestiques produisant de l'eau chaude sanitaire utilisant les combustibles
gazeux - Partie 5 : Evaluation de la consommation énergétique des appareils à gaz
combinés à une pompe à chaleur électrique
Ta slovenski standard je istoveten z: FprEN 13203-5
ICS:
91.140.65 Oprema za ogrevanje vode Water heating equipment
kSIST FprEN 13203-5:2015 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
kSIST FprEN 13203-5:2015

---------------------- Page: 2 ----------------------
kSIST FprEN 13203-5:2015

EUROPEAN STANDARD
FINAL DRAFT
FprEN 13203-5
NORME EUROPÉENNE

EUROPÄISCHE NORM

April 2015
ICS 91.140.65
English Version
Gas-fired domestic appliances producing hot water - Part 5:
Assessment of energy consumption of gas fired appliances
combined with electrical heat pump
Appareils domestiques produisant de l'eau chaude sanitaire
utilisant les combustibles gazeux - Partie 5 : Evaluation de
la consommation énergétique des appareils à gaz
combinés à une pompe à chaleur électrique
This draft European Standard is submitted to CEN members for unique acceptance procedure. It has been drawn up by the Technical
Committee CEN/TC 109.

If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations which
stipulate the conditions for giving this European Standard the status of a national standard without any alteration.

This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other language
made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United
Kingdom.

Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are aware and to
provide supporting documentation.

Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without notice and
shall not be referred to as a European Standard.


EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2015 CEN All rights of exploitation in any form and by any means reserved Ref. No. FprEN 13203-5:2015 E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------
kSIST FprEN 13203-5:2015
FprEN 13203-5:2015 (E)
Contents Page
Foreword .4
1 Scope .5
2 Normative references .5
3 Terms and definitions .5
4 General test conditions .7
4.1 Reference conditions .7
4.2 Specific heat source conditions .7
4.3 Measurement uncertainties .8
4.4 Test conditions .9
4.4.1 General .9
4.4.2 Test room .9
4.4.3 Water supply . 10
4.4.4 Steady-state . 10
4.4.5 Initial adjustment of the appliance . 10
4.4.6 Electrical supply . 11
5 Determination of the energy consumption of the appliance . 11
5.1 General . 11
5.2 Tapping cycles . 11
5.3 Measurement of the energy recovered by the useful water . 20
5.4 Calculation of gas energy . 20
5.4.1 Calculation of daily gas energy consumption . 20
5.4.2 Calculation of total gas energy consumption . 21
5.5 Calculation of electrical energy . 22
5.5.1 Calculation of daily electrical energy consumption. 22
5.5.2 Calculation of total electrical energy consumption . 22
5.6 Corrections to apply for fans and liquid pumps . 23
5.6.1 Power absorbed by the fans of connected heat pumps . 23
5.6.2 Power absorbed by liquid pumps . 24
6 Determination of the wasted water . 25
7 Eco design Related Products Data . 25
7.1 Water heating energy efficiency . 25
7.2 Annual fuel consumption (AFC) . 26
7.3 Annual electricity consumption (AEC) . 27
Annex A (informative)  Test conditions . 28
Annex B (informative)  Test rig and measurement devices . 32
B.1 General . 32
B.2 Pressure measurement . 33
B.3 Temperature measurement . 33
Annex C (informative) Packages covered by the present document . 37
Annex D (informative)  Additional performance data . 42
D.1 Heating time . 42
D.2 Standby power input . 43
D.3 Coefficient of primary energy performance or primary energy yield (PER) . 43
2

---------------------- Page: 4 ----------------------
kSIST FprEN 13203-5:2015
FprEN 13203-5:2015 (E)
D.4 Total consumption of primary energy . 44
Annex ZA (informative) Relationship between this European Standard and the requirements of

Commission Regulation (EC) n° 814/2013 . 45
Annex ZB (informative) Relationship between this European Standard and the requirements of

Commission Regulation n° 812/2013. 46
Annex ZC (informative) Relationship between this European Standard and the requirements of

Commission Regulation (EU) n° 813/2013 . 47
Annex ZD (informative) Relationship between this European Standard and the requirements of

Commission Delegated Regulation (EU) n° 811/2013 . 48
Bibliography . 49


3

---------------------- Page: 5 ----------------------
kSIST FprEN 13203-5:2015
FprEN 13203-5:2015 (E)
Foreword
This document (FprEN 13203-5:2015) has been prepared by Technical Committee CEN/TC 109 “Central
heating boilers using gaseous fuels”, the secretariat of which is held by NEN.
This document is currently submitted to the Unique Acceptance Procedure.
This document has been prepared under a mandate given to CEN by the European Commission and the
European Free Trade Association, and supports essential requirements of EU Directive(s).
For relationship with EU Directive(s), see informative Annex ZA, B, C or D, which are integral parts of this
document.
The safety operation of the boiler is not covered by this standard. Safety should be proved by means of the
essential safety requirements of the Gas Appliances Directive 2009/142/EC. This way be achieved by
compliance with the appropriate existing harmonized standards.
NOTE Useful standards are EN 26, EN 89, EN 15502–1, EN 15502–2-1 and EN 15502–2-2.
4

---------------------- Page: 6 ----------------------
kSIST FprEN 13203-5:2015
FprEN 13203-5:2015 (E)
1 Scope
This European Standard is applicable to gas-fired appliances producing domestic hot water. It applies to both
instantaneous and storage gas-fired appliances combined with electrical heat pump.
It applies to a package marketed as single unit or fully specified by a manufacturer that have:
— a gas heat input not exceeding 70 kW;
— a hot water storage capacity not exceeding 500 l.
Standard EN 13203-1 sets out in qualitative and quantitative terms the performance in delivery of domestic
hot water for a selected variety of uses. It also gives a system for presenting the information to the user. This
Part 5 sets out a method for assessing the energy performance of gas fired appliances combined with heat
pump with electrically driven compressor according to EN 16147.
This European standard does not apply for gas boilers with recovery systems using combustion products as
heat source for the electrical heat pump.
When the electrical heat pump does not work for domestic hot water production in the summer period, the
present standard is not applicable for energy performances assessing, EN 13203-2 should be used.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated references,
the latest edition of the referenced document (including any amendments) applies.
EN 13203-1, Gas-fired domestic appliances producing hot water - Appliances not exceding 70 kW heat input
and 300 l water storage capacity - Part 1: Assessment of performance of hot water deliveries
EN 13203-2, Gas-fired domestic appliances producing hot water - Appliances not exceeding 70 kW heat input
and 300 l water storage capacity - Part 2: Assessment of energy consumption
EN 14511-3:2013, Air conditioners, liquid chilling packages and heat pumps with electrically driven
compressors for space heating and cooling - Part 3: Test methods
EN 16147, Heat pumps with electrically driven compressors – Testing and requirements for marking for
domestic hot water units
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1
control cycle
time cycle for keeping components and/or the tank (if any) of the domestic hot water circuit at predetermined
temperature level, consists of an «ON» duration time during which the heating of the domestic hot water (by
gas energy and/or auxiliary energy) is operating, and an «OFF» duration time during which no heating occurs
3.2
domestic water test temperature
temperature of the delivered water at which the tests are conducted
5

---------------------- Page: 7 ----------------------
kSIST FprEN 13203-5:2015
FprEN 13203-5:2015 (E)
3.3
nominal domestic hot water heat input
Q
nw
value of the heat input as stated by the technical instructions for the production of domestic hot water
Note 1 to entry: Q is expressed in kilowatt (kW)
nw
3.4
off mode
state of an appliance, selected by the user, in which domestic hot water can not be provided
3.5
stand-by mode
operating state in which the appliance can provide domestic hot water at any time
Note 1 to entry: In the case of an appliance with a control cycle for keeping components and/or the tank (if any) of the
domestic hot water circuit at predetermined temperature level, no tapping is made
3.6
summer mode
conditions during which the appliance supplies energy only for the production of domestic hot water
3.7
storage tank
reservoir for domestic hot water
3.8
useful water
quantity of water delivered at the tap for which the temperature increase is in accordance with the requirement
fixed for each individual delivery of the tapping cycles
3.9
wasted water
quantity of water delivered at the tap for which the temperature increase is not in accordance with the
requirement fixed for each individual delivery of the tapping cycles
3.10
winter mode
conditions during which the appliance supplies energy for the production of domestic hot water and/or space
heating
3.11
indoor ambient air
heat source for a heat pump which absorbs heat by a heat exchanger in direct contact with the air inside a
building without any dedicated duct
3.12
brine
heat transfer medium which has a freezing point depressed relative to water
6

---------------------- Page: 8 ----------------------
kSIST FprEN 13203-5:2015
FprEN 13203-5:2015 (E)
3.13
gas-fired appliance combined with electrical heat pump
appliance which is either placed on the market or specified as a complete package to deliver safely and
effectively domestic hot water or domestic hot water and heating, comprising as relevant:
— electrical heat pump;
— gas-fired appliance;
— ducts if appropriate;
— thermal store
3.14
useful water flow rate
flow rate of water delivered at the tap for which the temperature increase is in accordance with the
requirement fixed for each individual delivery of the tapping cycles
3.15
useful water temperature
water temperature, expressed in degrees Celsius, delivered at the tap
3.16
appliance flow rate
flow rate delivered by the appliance before the mixing device, if applicable
3.17
appliance water temperature
(T )
d
water temperature, expressed in degrees Celsius, delivered by the appliance before the mixing device
4 General test conditions
4.1 Reference conditions
Unless otherwise stated, the general test conditions shall be as follows:
— cold water temperature: 10°C
— maximum average variation over the test period: ± 2 K
— cold water pressure: (2 ± 0,1) bar
— ambient air temperature: 20°C
— maximum average variation over the test period ± 1 K
— maximum variation during the tests ± 2 K
— electrical supply voltage: (230 ± 2) V (single phase).
4.2 Specific heat source conditions
The tests shall be carried out at the test conditions specified in Table 1 as appropriate.
7

---------------------- Page: 9 ----------------------
kSIST FprEN 13203-5:2015
FprEN 13203-5:2015 (E)
Table 1 - Test conditions for particular types of systems
Type of heat source Heat source Range of ambient Ambient temperature of
temperature (°C) temperature for heat storage tank (°C)
pump
(°C)
7 ± 0,2
Outside air (heat pump
20 ± 3 20 ± 3
indoor) with air duct
(6 ± 0,3)
7 ± 0,2
Outside air (heat pump
a
7 ± 3 20 ± 3
outdoor)
(6 ± 0,3)
20 ± 0,2
a a
Exhaust air 20 ± 3 20 ± 3
(12 ± 0,3)
Water (inlet) 10 ± 0,15 20 ± 3 20 ± 3
Brine (inlet) 0 ± 0,15 20 ± 3 20 ± 3
Direct evaporation 4 ± 0,5 20 ± 3 20 ± 3
a
In this case the ambient temperature of the heat pump is the same as the temperature of the heat source (the difference
with EN 16147 is justified because of the possible installation of the appliance into a living room).
NOTE 1 All heat source temperatures are inlet temperatures in °C.
NOTE 2 All air temperatures in (brackets) are wet bulb temperatures in °C.
NOTE 3 Permissible external pressure difference and associated internal pressure difference at the outdoor heat
exchanger as stated in the installation and/or operation manual in Pascal (Pa) for appliances with duct connection.
4.3 Measurement uncertainties
Except where otherwise stated in the clauses describing the tests, the uncertainties of measurements carried
out shall be not greater than the maximum uncertainties indicated below.
The standard deviations shall be evaluated taking account of the various sources of uncertainty: contribution
from the instrument, repeatability, calibration, ambient conditions:
— water rate: ± 1 %;
— gas rate: ± 1 %;
— time: ± 0,2 s;
— temperatures:
— ambient air: ± 1 K;
— air as heat source dry bulb temperature: ± 0,2 °C;
— air as heat source wet bulb temperature: ± 0,3 °C;
— water/brine as heat source: ± 0,15 K
— water: ± 0,5 K;
— gas: ± 0,5 K;
— mass: ± 0,5 %;
8

---------------------- Page: 10 ----------------------
kSIST FprEN 13203-5:2015
FprEN 13203-5:2015 (E)
— gas pressure: ± 1 %;
— gas calorific value: ± 1 %;
— gas density: ± 0,5 %;
— electrical energy: ± 2 %.
The stated measurement uncertainties relate to individual measurements. For measurements that combine a
number of individual measurements, smaller uncertainties on the individual measurements may be necessary
to ensure a total uncertainty within ± 2 % under the steady-state conditions.
These uncertainties correspond to two standard deviations (2σ).
4.4 Test conditions
4.4.1 General
Except where otherwise stated, the appliance is tested under the following conditions.
The tests are carried out only in summer mode.
The test conditions are given in Table 1.
If liquid heat transfer media other than water are used, the specific heat capacity and density of such heat
transfer media shall be determined and taken into consideration in the evaluation.
When the electric heat pump combined with a gas-fired appliance does not operate in heat pump mode for
domestic hot water production according to data in Table 1, the test shall be performed according to
EN 13203-2 instead.
For all tests defined by this standard, the same adjustment of the appliance shall be maintained.
4.4.2 Test room
The package shall be installed in a well-ventilated, draught-free room (air speed less than 0,5 m/s).
The package shall be protected from direct solar radiation and radiation from heat generators.
If the package incorporates an air source outdoor heat exchanger a further test room is needed. The size of
this test room shall be designed to avoid any resistance to air flow at the air inlet and air outlet orifices of the
test object. The air flow through this room shall not cause any short circuit between the two orifices, and
therefore the velocity of air flow at these two locations shall not exceed 1,5 m/s when the test object is
switched off. The air velocity in the room shall also not be greater than the mean velocity through the unit inlet.
Unless otherwise stated in the technical documentation, the air inlet and air outlet orifices shall not be less
than 1m from the surfaces of the test room; this also applies to any measuring ducts.
The setting of the external static pressure difference on the air side for heat pumps with duct connection is
described by 4.4.1.4 of EN 14511-3:2013.
For heat pumps separated from the tank, the liquid flow rate has to be set on the liquid outlet side of the heat
pump to the nominal flow rate specified in the technical documentation.
The package shall be installed and connected for the test as specified in the installation instructions.
Temperature and pressure measuring points shall be situated in order to obtain significant mean values.
9

---------------------- Page: 11 ----------------------
kSIST FprEN 13203-5:2015
FprEN 13203-5:2015 (E)
Set points for internal control equipment of the unit such as thermostats, pressure switches or mixing valves
shall be set to the values stated in the technical documentation.
Air and entrained gases shall be removed from all water and other heat transfer liquid systems
In the case of package incorporating a single split heat pump, the following installation conditions shall be
complied with for the tests:
a) each refrigerant pipe shall be installed in accordance with the installation instructions;
b) the connecting pipes shall be installed so that the difference in elevation does not exceed 1 m. The length
of each connecting pipe shall be between 5 m and 7,5 m;
c) thermal insulation shall be applied to the pipes in accordance with the installation instructions;
d) unless constrained by the design at least half of the interconnecting pipes shall be exposed to the outdoor
conditions with the rest of the pipes exposed to the indoor conditions.
For indirect systems each water pipe shall be installed in accordance with the installation instructions to the
maximum stated length or 5 m whichever is shorter. Thermal insulation shall be applied to the pipes in
accordance with the installation instructions.
4.4.3 Water supply
For the tests:
— the domestic water pressure is the static inlet pressure under dynamic conditions measured as close as
possible to the appliance;
— the inlet and outlet temperatures of the domestic water shall be measured in the centre of the flow and as
close as possible to the appliance.
The inlet temperatures shall be measured immediately upstream of the water inlet connection. Except where
otherwise stated, the outlet temperatures shall be measured immediately downstream of the outlet connection
or, in the case of an appliance with spout delivery, by means of an immersed temperature measuring device,
e.g. a u-tube fitted at the outlet of a tube of the same length as the minimum length of the spout normally
supplied together with the appliance.
The hot water temperature shall be measured with a rapid response thermometer.
“Rapid response thermometer” means a measuring instrument with a response time such that 90 % of the
final temperature rise, from 15 °C to 100 °C, is obtained within about 1 s, when the sensor is plunged into still
water.
4.4.4 Steady-state
Steady-state operating conditions shall be regarded as established when the appliance operates for sufficient
time to reach thermal stabilization. The steady-state is reached when the water temperature at the outlet does
not vary by more than ± 0,5 K.
NOTE This condition can be reached with a gas which is different from the specified test gas, provided that the
appliance is supplied with the specified test gas for at least 5 min before the requirements are verified.
4.4.5 Initial adjustment of the appliance
The appliance shall be installed in accordance with the installation instructions.
10

---------------------- Page: 12 ----------------------
kSIST FprEN 13203-5:2015
FprEN 13203-5:2015 (E)
The heat input shall be adjusted to within ± 2 % of the nominal domestic hot water heat input under the
conditions prevailing at the time of the test.
The delivered water temperature at the appliance outlet shall be as follows (see Figures A.1 and A.2):
a) appliances with an adjustable temperature: the tests are carried out at a temperature not greater than
65 °C, with a minimum temperature increase equal to or greater than 45 K above water inlet temperature;
b) appliances with a fixed temperature: the tests are carried out at the temperature specified by the
manufacturer, with a minimum temperature increase equal to or greater than 45 K.
The same conditions of initial adjustment stated in the appliance documentation shall be used for all the tests.
These conditions shall be included in the test report.
4.4.6 Electrical supply
The appliance shall be supplied with the nominal voltage or a voltage included within the range of nominal
voltages stated in the installation instructions.
5 Determination of the energy consumption of the appliance
5.1 General
This clause defines the test methods to be employed in determining the energy consumption of appliances.
5.2 Tapping cycles
All patterns define a 24 h measurement cycle and within that cycle the starting times and the total energy
content (in kWh equivalent of hot water tapped) of each draw-off are defined.
Furthermore, the draw-off can be characterized in two ways, either “basin” type draw-off versus “continuous
flow” draw-off.
The aim of the “basin” type is to arrive at an average temperature of the tub, so all supplied energy can be
considered useful from the very beginning of the draw-off (minimum useful temperature increase is 0 K). The
average temperature rising (ΔT desired) to be achieved during tapping, shall be for floor cleaning and bath
30 K and for the dish washes 45 K.
The aim of the “continuous flow” type is to use only the water with a minimum temperature. For the shower,
household cleaning and large draw-offs a temperature rise of 30 K shall be reached before counting the useful
energy. For the small draw-offs a temperature rise of 15 K shall be reached.
NOTE 1 The temperature rises (in K) stated above are equivalent to the temperatures (in °C) given by the load profiles
tables in Regulations n° 811/2013, n° 812/2013, n° 813/2013 and n° 814/2013 based on 10 °C inlet water temperature.
The tapping flow rates used to perform the different types of tapping of each of the seven tapping cycles
defined by Tables 2 to 8.
When these tapping rates result in a tapping period of less than 15 s the flow rate should be decreased such
that the tapping period is (16 ± 1) s.
In the tapping cycles, the requirements for flow and temperatures are based on the delivery on the taps in a
mix of hot and cold water. Under the conditions of the initial adjustment, the appliance itself produces hot
water with a minimum temperature rise of 45 K.
11

---------------------- Page: 13 ----------------------
kSIST FprEN 13203-5:2015
FprEN 13203-5:2015 (E)
To fulfil the requirements stated in Tables 2 to 8 mixing hot water from the appliance with cold water of 10°C
at the tap is allowed either by using a mixing device (see Figure B.5) or by recalculating the minimum
appliance flow rate (see 3.16) according to the following formula:
DT
useful
D = D ⋅
(1)
min useful(ΔT )
DT
d
Where:
D is the minimum test rig setting for the appliance flow rate of each individual tapping at
min
temperature rise corresponding to ΔT , in l/min;
d
D is the useful water flow rate according to Tables 2 to 8, in l/min;
useful (ΔT)
ΔT is the appliance delivered water temperature rise with a m
...

SLOVENSKI STANDARD
kSIST FprEN 13203-5:2018
01-marec-2018
3OLQVNHJRVSRGLQMVNHQDSUDYH]DSULSUDYRWRSOHVDQLWDUQHYRGHGHO
2FHQMHYDQMHSRUDEHHQHUJLMHSOLQVNLKDSDUDWRYNRPELQLUDQLK]HOHNWULþQRWRSORWQR
þUSDONR
Gas-fired domestic appliances producing hot water - Part 5: Assessment of energy
consumption of gas fired appliances combined with electrical heat pump
Gasbeheizte Geräte für die sanitäre Warmwasserbereitung für den Hausgebrauch - Teil
5: Bewertung des Energieverbrauchs von Gasgeräten mit elektrischer Wärmepumpe
Appareils domestiques produisant de l'eau chaude sanitaire utilisant les combustibles
gazeux - Partie 5 : Evaluation de la consommation énergétique des appareils à gaz
combinés à une pompe à chaleur électrique
Ta slovenski standard je istoveten z: FprEN 13203-5
ICS:
27.080 7RSORWQHþUSDONH Heat pumps
91.140.65 Oprema za ogrevanje vode Water heating equipment
kSIST FprEN 13203-5:2018 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
kSIST FprEN 13203-5:2018

---------------------- Page: 2 ----------------------
kSIST FprEN 13203-5:2018


FINAL DRAFT
EUROPEAN STANDARD
FprEN 13203-5
NORME EUROPÉENNE

EUROPÄISCHE NORM

February 2018
ICS 91.140.65
English Version

Gas-fired domestic appliances producing hot water - Part
5: Assessment of energy consumption of gas fired
appliances combined with electrical heat pump
Appareils domestiques produisant de l'eau chaude Gasbeheizte Geräte für die sanitäre
sanitaire utilisant les combustibles gazeux - Partie 5 : Warmwasserbereitung für den Hausgebrauch - Teil 5:
Évaluation de la consommation énergétique des Bewertung des Energieverbrauchs von Gasgeräten mit
appareils utilisant les combustibles gazeux combinés à elektrischer Wärmepumpe
une pompe à chaleur électrique
This draft European Standard is submitted to CEN members for second unique acceptance procedure. It has been drawn up by
the Technical Committee CEN/TC 109.

If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations
which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.

This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and United Kingdom.

Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.

Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a European Standard.


EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2018 CEN All rights of exploitation in any form and by any means reserved Ref. No. FprEN 13203-5:2018 E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------
kSIST FprEN 13203-5:2018
FprEN 13203-5:2018 (E)
Contents Page
European foreword . 4
Introduction . 5
1 Scope . 6
2 Normative references . 6
3 Terms and definitions . 6
4 General test conditions . 9
4.1 Reference conditions . 9
4.2 Specific heat source temperature conditions . 9
4.3 Measurement uncertainties . 10
4.3.1 General . 10
4.3.2 Steady-state conditions . 11
4.4 Test conditions . 11
4.4.1 General . 11
4.4.2 Test room . 11
4.4.3 Water supply . 12
4.4.4 Initial adjustment of the appliance . 12
4.4.5 Conditions for the determination of the maximum load profile . 13
4.4.6 Electrical supply . 13
5 Determination of the energy consumption of the appliance . 13
5.1 General . 13
5.2 Load profiles . 13
5.3 Determination of the energy recovered by the useful water . 21
5.4 Calculation of gas energy . 22
5.4.1 Calculation of daily gas energy consumption in summer mode . 22
5.5 Calculation of electrical energy . 22
5.5.1 Calculation of daily electrical energy consumption . 22
5.6 Corrections to apply for fans and liquid pumps . 23
5.6.1 Power absorbed by the fans of connected heat pumps . 23
5.6.2 Power absorbed by liquid pumps . 24
5.7 Measurement of energy consumption in standby mode . 24
5.7.1 General . 24
5.7.2 Calculation of daily gas energy consumption in standby mode . 25
5.7.3 Calculation of daily auxiliary electrical energy consumption in standby mode . 25
5.8 Determination of daily auxiliary electrical energy consumption in off mode . 26
6 Determination of the ratio of wasted water to total water . 26
7 Eco design Related Products Data . 27
7.1 Water heating energy efficiency . 27
7.2 Annual fuel consumption (AFC) . 28
7.3 Annual electricity consumption (AEC) . 28
7.4 Mixed water at 40°C (V40) for storage water heaters . 29
Annex A (informative)  Test conditions . 31
Annex B (informative) Test rig and measurement devices . 35
2

---------------------- Page: 4 ----------------------
kSIST FprEN 13203-5:2018
FprEN 13203-5:2018 (E)
B.1 General. 35
B.2 Pressure measurement. 36
B.3 Temperature measurement . 36
Annex C (informative) Declaration of the Maximum Load Profile . 40
Annex D (informative)  Packages covered by the present document . 41
Annex E (informative) Additional performance data . 46
E.1 Heating time. 46
E.2 Standby power input . 46
E.3 Coefficient of primary energy performance or primary energy yield (PER) . 47
E.4 Total consumption of primary energy . 47
Annex ZA (informative) Relationship between this European Standard and the ecodesign
requirements of Commission Regulation (EU) n° 814/2013 [OJEU L239 of 6 September
2013] aimed to be covered . 49
Annex ZB (informative) Relationship between this European Standard and the energy labelling
requirements of Commission Delegated Regulation (EU) No 812/2013 [OJEU L239 of 6
September 2013] aimed to be covered . 50
Annex ZC (informative) Relationship between this European Standard and the ecodesign
requirements of Commission Regulation (EU) n° 813/2013 [OJEU L239 of 6 September
2013] aimed to be covered . 51
Annex ZD (informative) Relationship between this European Standard and the energy labelling
requirements of Commission Delegated Regulation (EU) No 811/2013 [OJEU L239 of 6
September 2013] aimed to be covered . 52

3

---------------------- Page: 5 ----------------------
kSIST FprEN 13203-5:2018
FprEN 13203-5:2018 (E)
European foreword
This document (FprEN 13203-5:2018) has been prepared by Technical Committee CEN/TC 109 “Central
heating boilers using gaseous fuels”, the secretariat of which is held by NEN.
This document is currently submitted to the Unique Acceptance Procedure.
This document has been prepared under a mandate given to CEN by the European Commission and the
European Free Trade Association, and supports essential requirements of EU Directive(s).
For relationship with EU Directive(s), see informative Annex ZA, ZB, ZC or ZD, which are integral parts of this
document.
The main purpose of this revision is to provide a means of conforming to requirements of Commission
Delegated Regulation (EC) n° 813/2013, (EC) n° 811/2013, (EC) n° 812/2013 and (EC) n° 814/2013.
4

---------------------- Page: 6 ----------------------
kSIST FprEN 13203-5:2018
FprEN 13203-5:2018 (E)
Introduction
The safety operation of the boiler or water heater is not covered by this standard. Safety should be proved by
means of the essential safety requirements of the Gas Appliances Directive 2009/142/EC. This may be
achieved by compliance with the appropriate existing harmonized standards.
NOTE Useful standards are EN 26, EN 89 and series EN 15502.
5

---------------------- Page: 7 ----------------------
kSIST FprEN 13203-5:2018
FprEN 13203-5:2018 (E)
1 Scope
This European Standard is applicable to gas-fired appliances producing domestic hot water. It applies to both
instantaneous and storage gas-fired combined with electrical heat pump.
It applies to a package marketed as single unit or fully specified by the manufacturer that have:
— a heat input not exceeding 400 kW; and
— a hot water storage tank capacity (if any) not exceeding 2000 l.
EN 13203-1 sets out in qualitative and quantitative terms the performance in delivery of domestic hot water
for a selected variety of uses. It also gives a system for presenting the information to the user. The present
document sets out a method for assessing the energy performance of gas fired appliances combined with heat
pump with electrically driven compressor according to EN 16147. It defines a number of daily load profiles
for each domestic hot water use, kitchen, shower, bath and a combination of these, together with
corresponding test procedures, enabling the energy performances of different gas-fired appliances to be
compared and matched to the needs of the user. Where other technologies are combined with a gas-fired
boiler or a water heater to produce domestic hot water, specific parts of EN 13203 apply.
The present document does not apply for gas boilers with recovery systems using combustion products as
heat source for the electrical heat pump.
When the electrical heat pump does not work for domestic hot water production in the summer period, the
present standard is not applicable for energy performances assessing, EN 13203-2 should be used.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes
requirements of this document. For dated references, only the edition cited applies. For undated references,
the latest edition of the referenced document (including any amendments) applies.
EN 14511-3:2013, Air conditioners, liquid chilling packages and heat pumps with electrically driven
compressors for space heating and cooling - Part 3: Test methods
EN 16147:2017, Heat pumps with electrically driven compressors - Testing and requirements for marking of
domestic hot water units
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
• IEC Electropedia: available at http://www.electropedia.org/
• ISO Online browsing platform: available at http://www.iso.org/obp
3.1
storage tank
reservoir for domestic hot water
3.2
nominal domestic hot water heat input of the boiler (Q )
nw
value of the heat input of the boiler for the production of domestic hot water stated in the instructions, the
symbol of which is Q and the unit of which is kilowatt (kW)
nw
6

---------------------- Page: 8 ----------------------
kSIST FprEN 13203-5:2018
FprEN 13203-5:2018 (E)
3.3
summer mode
conditions during which the appliance supplies energy only for the production of domestic hot water
3.4
winter mode
conditions during which the combination boiler supplies energy for the production of domestic hot water and
space heating
3.5
domestic water test temperature
temperature of the delivered water at which the tests are conducted
3.6
control cycle
the time cycle for keeping components and/or the storage tank (if any) of the domestic hot water circuit at
predetermined temperature level, consists of an «ON» duration time during which the heating of the domestic
hot water (by gas energy and/or auxiliary energy) is operating, and an «OFF» duration time during which no
heating occurs
3.7
useful water
quantity of water delivered at the tap for which the temperature increase is in accordance with the
requirement fixed for each individual delivery of the load profiles
3.8
wasted water
quantity of water delivered at the tap for which the temperature increase is not in accordance with the
requirement fixed for each individual delivery of the load profiles
3.9
stand by mode
operating state in which the appliance can provide domestic hot water at any time
Note 1 to entry: In the case of an appliance with a control cycle for keeping components and/or the storage tank (if
any) of the domestic hot water circuit at predetermined temperature level no draw-off is made.
3.10
off mode
state of an appliance, selected by the user, in which domestic hot water cannot be provided
3.11
useful water flow rate
D
useful
quantity of water delivered by unit time at the tap for which the temperature increase is in accordance with
the requirement fixed for each individual draw-off of the load profiles
3.12
useful water temperature
water temperature, expressed in degrees Celsius, delivered at the tap
3.13
appliance flow rate
quantity of water delivered by the appliance by unit time before the mixing device, if applicable
7

---------------------- Page: 9 ----------------------
kSIST FprEN 13203-5:2018
FprEN 13203-5:2018 (E)
3.14
appliance water temperature
T
d
water temperature, expressed in degrees Celsius, delivered by the appliance before the mixing device
3.15
water temperature rise in K
∆T
m
difference between the useful water temperature and the cold water temperature, at which hot water is
contributing to the reference energy as specified in the load profiles
3.16
water temperature rise for basin draw-off types in K
∆T
p
difference between the useful water temperature and the cold water temperature, to be achieved during the
water draw-offs, with a minimum value as specified in the load profiles
Note 1 to entry: to entry The minimum temperature difference for basin draw-offs as specified in the load profiles
shall be achieved at least during the water draw-offs.
3.17
rapid response temperature sensor
measuring instrument with a response time such that 90 % of the final temperature rise, from 15 °C to 100 °C,
is obtained within about 1 s, when the sensor is plunged into still water.
3.18
indoor air
heat source for a heat pump which absorbs heat by a heat exchanger in direct contact with the air inside a
building
3.19
brine
heat transfer medium which has a freezing point depressed relative to water
3.20
gas-fired appliance combined with electrical heat pump air/water
appliance which is either placed on the market or specified as a complete package to deliver domestic hot
water or domestic hot water and heating, comprising as relevant:
— electrical heat pump;
— gas-fired appliance;
— ducts if appropriate;
— thermal store.
3.21
exhaust air
air from the air conditioned space entering the outdoor heat exchanger
[EN 14511-1:2013, 2.17]
8

---------------------- Page: 10 ----------------------
kSIST FprEN 13203-5:2018
FprEN 13203-5:2018 (E)
3.22
external static pressure difference
Δp
ext
positive pressure difference measured between the air (or water) outlet section and the air (or water) inlet
section of the unit, which is available for overcoming the pressure drop of any additional ducted air (or water)
circuit
3.23
internal static pressure difference
Δp
int
negative pressure difference measured between the air (or water) outlet section and the air (or water) inlet
section of the unit, which corresponds to the total pressure drop of all components on the air (or water) side
of the unit
4 General test conditions
4.1 Reference conditions
Unless otherwise stated, the general test conditions shall be as follows:
— cold water temperature: 10 °C;
— maximum average variation over the test period: ± 2 K;
— cold water pressure: (2 ± 0,1) bar;
— ambient air temperature: 20 °C;
— maximum average variation over the test period ± 2 K;
— maximum variation during the tests ± 2 K;
— electrical supply voltage: (230 ± 2) V (single phase) or (410 ± 4) V (three phase).
4.2 Specific heat source temperature conditions
The tests shall be carried out at the test conditions specified in Table 1 as appropriate.
9

---------------------- Page: 11 ----------------------
kSIST FprEN 13203-5:2018
FprEN 13203-5:2018 (E)
Table 1 — Test conditions for particular types of systems
Type of heat source Heat source Range of ambient Ambient temperature
temperature (°C) temperature for heat of storage tank (°C)
pump
(°C)
Outside air (heat pump
7 ± 0,2 20 ± 3 20 ± 3
indoor) with air duct
 (6 ± 0,3)
Outside air (heat pump
a)
7 ± 0,2 20 ± 3
7 ± 3
outdoor)
 (6 ± 0,3)
a) a)
Exhaust air 20 ± 0,2
20 ± 3 20 ± 3
 (12 ± 0,3)
Water (inlet) 10 ± 0,15 20 ± 3 20 ± 3
Brine (inlet) 0 ± 0,15 20 ± 3 20 ± 3
Direct evaporation 4 ± 0,5 20 ± 3 20 ± 3
a)
In this case the ambient temperature of the heat pump is the same as the temperature of the heat source (the
difference with EN 16147 is justified because of the possible installation of the appliance into a living room).
NOTE 1 All heat source temperatures are inlet temperatures in °C.
NOTE 2 All air temperatures in (brackets) are wet bulb temperatures in °C.
NOTE 3 Permissible external pressure difference and associated internal pressure difference at the outdoor heat
exchanger as stated in the installation and/or operation manual in Pascal (Pa) for appliances with duct
connection.
4.3 Measurement uncertainties
4.3.1 General
Except where otherwise stated in the clauses describing the tests, the uncertainties of measurements carried
out shall not be greater than the maximum uncertainties indicated below.
The standard deviations shall be evaluated taking into account the various sources of uncertainty:
contribution from the instrument, repeatability, calibration, ambient conditions, etc.
— water flow rate: ± 1 %;
— gas flow rate: ± 1 %;
— time: ± 0,2 s;
— temperatures:
— ambient: ± 1 K;
— air as heat source dry bulb temperature: ± 0,2 °C;
— air as heat source wet bulb temperature: ± 0,3 °C;
10

---------------------- Page: 12 ----------------------
kSIST FprEN 13203-5:2018
FprEN 13203-5:2018 (E)
— water/brine as heat source: ± 0,15 K;
— water: ± 0,5 K;
— gas: ± 0,5 K;
— gas pressure: ± 1 %;
— gas calorific value: ± 1 %;
— gas density: ± 0,5 %;
— electrical energy: ± 2 %.
The stated measurement uncertainties relate to individual measurements. For measurements that combine a
number of individual measurements, smaller uncertainties on the individual measurements may be necessary
to ensure a total uncertainty within ± 2 % under the steady-state conditions as defined by 4.3.2.
These uncertainties correspond to two standard deviations (2σ).
4.3.2 Steady-state conditions
Steady-state operating conditions are regarded as established when the appliance operates for sufficient time
to reach thermal stabilization.
To reach the steady-state the water temperature at the outlet of the appliance shall not vary by more
than ± 0,5 K.
NOTE This condition can be reached with a gas which is different from the reference gas, provided that the
appliance is supplied with the reference gas for at least 5 min before the requirements are verified.
4.4 Test conditions
4.4.1 General
Except where otherwise stated, the appliance is tested under the following conditions.
The tests shall be carried out only in summer mode as defined in 3.3, and the appliance shall be set in summer
mode.
If liquid heat transfer media other than water are used, the specific heat capacity and density of such heat
transfer media shall be determined and taken into consideration in the evaluation.
For all tests defined by this standard, the same adjustment of the appliance shall be maintained.
The load profile used for the measurement shall be the one declared according to the technical instruction of
the appliance (see also Annex C).
The test shall be performed in the setting in which the appliance is delivered, and which is documented as
such in the technical instructions.
If there are temporary user's settings (automatically self-resetting within 24 h), these shall not be active.
4.4.2 Test room
The package shall be installed in a well-ventilated, draught-free room (air speed less than 0,5 m/s).
The package shall be protected from direct solar radiation and radiation from heat generators.
If the package incorporates an air source outdoor heat exchanger a further test room is needed. The size of
this test room shall be designed to avoid any resistance to air flow at the air inlet and air outlet orifices of the
11

---------------------- Page: 13 ----------------------
kSIST FprEN 13203-5:2018
FprEN 13203-5:2018 (E)
test object. The air flow through this room shall not cause any short circuit between the two orifices, and
therefore the velocity of air flow at these two locations shall not exceed 1,5 m/s when the test object is
switched off. The air velocity in the room shall also not be greater than the mean velocity through the unit
inlet.
Unless otherwise stated in the technical documentation, the air inlet and air outlet orifices shall not be less
than 1m from the surfaces of the test room; this also applies to any measuring ducts.
The setting of the external static pressure difference on the air side for heat pumps with duct connection is
described by 4.4.1.4 of EN 14511-3:2013.
For heat pumps separated from the tank, the liquid flow rate has to be set on the liquid outlet side of the heat
pump to the nominal flow rate specified in the technical documentation.
The package shall be installed and connected for the test as specified in the installation instructions.
Temperature and pressure measuring points shall be situated in order to obtain significant mean values.
Set points for internal control equipment of the unit such as thermostats, pressure switches or mixing valves
shall be set to the values stated in the technical documentation.
Air and entrained gases shall be removed from all water and other heat transfer liquid systems
In the case of package incorporating a single split heat pump, the following installation conditions shall be
complied with for the tests:
a) each refrigerant pipe shall be installed in accordance with the installation instructions;
b) the connecting pipes shall be installed so that the difference in elevation does not exceed 2,5 m. The
length of each connecting pipe shall be between 5 m and 7,5 m;
c) thermal insulation shall be applied to the pipes in accordance with the installation instructions;
d) unless constrained by the design at least half of the interconnecting pipes shall be exposed to the outdoor
conditions with the rest of the pipes exposed to the indoor conditions.
For indirect systems each water pipe shall be installed in accordance with the installation instructions to the
maximum stated length or 5 m whichever is shorter. Thermal insulation shall be applied to the pipes in
accordance with the installation instructions.
4.4.3 Water supply
For the tests:
— the domestic water pressure is the static inlet pressure under dynamic conditions measured as close as
possible to the appliance (see Figure B.2);
— the inlet and outlet temperatures of the domestic water shall be measured in the centre of the flow and as
close as possible to the appliance (see Figure B.3) or at the tap.
The inlet temperatures shall be measured immediately upstream of the water inlet connection. Except where
otherwise stated, the outlet temperatures shall be measured immediately downstream of the outlet
connection or, in the case of an appliance with spout delivery, by means of an immers
...