Building hardware - Hardware for windows and door height windows - Requirements and test methods - Part 5: Devices that restrict the opening of windows and door height windows

This Part of EN 13126 specifies requirements and test methods for durability, strength, security and functionality of devices that restrict the opening of windows and door height windows.
On devices that restrict the opening of
-   Tilt&Turn, Tilt-First, Turn-Only, or Tilt-Only windows and door-height windows
-   horizontal and vertical pivot windows and door height windows
-   side-hung Casements and top-hung windows and door height windows (opening outwards)
this part of EN 13126 only applies, if a restriction of the opening occurs within the specification in Annex A, E or G of EN 1191:2012 in accordance with the intended use specified by the manufacturer

Baubeschläge - Beschläge für Fenster und Fenstertüren - Anforderungen und Prüfverfahren - Teil 5: Vorrichtungen zur Begrenzung des Öffnungswinkels von Fenstern

Der vorliegende Teil von EN 13126 legt die Anforderungen an und Prüfverfahren für die Dauerfunktions¬tüchtigkeit, Festigkeit, Schutzwirkung und Funktionsweise von Vorrichtungen zur Begrenzung des Öffnungs¬winkels von Fenstern und Fenstertüren fest.
Bei Begrenzern für
-   Drehkipp-Fenster, Kippdreh-Fenster oder Kipp-Fenster und Fenstertüren;
-   Schwingflügel- und Wendeflügel-Fenster und Fenstertüren;
-   auskragende Schwenkflügel- und Klappflügel-Fenster und Fenstertüren (nach außen öffnend)
gilt der vorliegende Teil von EN 13126 nur, wenn es in Übereinstimmung mit der vom Hersteller festgelegten bestimmungsgemäßen Verwendung zu einer Öffnungsbegrenzung innerhalb der Festlegung in Anhang A, E oder G von EN 1191:2012 kommt.
ANMERKUNG 1   Begrenzer und Rückstellbegrenzer können sowohl ein einzelnes Beschlagselement als auch ein integraler Teil der Beschläge, wie z. B. ein Teil der Betätigungsvorrichtung oder ein eingebauter Teil eines Türbands sein.
ANMERKUNG 2   Fenster können mit mehr als einem Begrenzer ausgerüstet sein.
ANMERKUNG 3   Die in der vorliegenden Norm enthaltenen Anforderungen berücksichtigen die Erfordernisse der Sicher¬heit von Kindern; für den Einbau durch den Endverbraucher vorgesehene Öffnungsbegrenzer für Fenster, die dem Kinderschutz dienen, sind in der vorliegenden Norm nicht enthalten. Für die Angebote von Baumärkten wird auf PC398 und EN 16281 verwiesen.

Quincaillerie pour le bâtiment - Exigences et méthodes d'essai des ferrures de fenêtres et portes-fenêtres - Partie 5: Dispositifs limiteurs d’ouverture des fenêtres et portes-fenêtres

La présente partie de l’EN 13126 spécifie les exigences et les méthodes d’essai relatives à l’endurance, à la résistance, à la sécurité des biens et aux fonctionnalités des dispositifs limiteurs d’ouverture des fenêtres et des portes-fenêtres.
seuls les dispositifs limiteurs d’ouverture des
-   fenêtres et portes-fenêtres pivotantes et basculantes, oscillo-battantes, pivotantes seulement et basculantes seulement
-   fenêtres et portes-fenêtres à pivotement horizontal et vertical
-   fenêtre à la française et fenêtres soufflet et portes-fenêtres (portes ouvrant vers l’extérieur)
sont concernés par la présente partie de l’EN 13126, si une limitation de l’ouverture existe dans la spécification de l’Annexe A, E ou G de l’EN 1191:2012 conformément à l’utilisation attendue spécifiée par le fabricant.
NOTE 1   Les limiteurs et les limiteurs réversibles peuvent soit être des éléments individuels de quincaillerie, soit faire partie intégrante de la quincaillerie, par exemple une partie du mécanisme de manoeuvre ou une partie intégrante de la paumelle.
NOTE 2   Les fenêtres peuvent être munies de plusieurs limiteurs.
NOTE 3   Les exigences incluses dans la présente norme tiennent compte des besoins liés à la sécurité des enfants ; les limiteurs de fenêtre de sécurité pour enfant destinés à être installés par le consommateur final sont en dehors du domaine d’application de la présente norme. Par conséquent, pour le marché DIY faire référence au PC 398 et à l’EN 16281.

Stavbno okovje - Okovje za okna in zastekljena vrata - Zahteve in preskusne metode - 5. del: Naprave, ki preprečujejo odpiranje oken in zastekljenih vrat

Ta del standarda EN 13126 določa zahteve in preskusne metode za trajnost, trdnost, varnost ter funkcionalnost naprav, ki preprečujejo odpiranje oken in zastekljenih vrat.
Na napravah, ki preprečujejo odpiranje
– oken na nagib in rotacijo, oken, ki zahtevajo najprej nagib, oken, ki omogočajo samo rotacijo oziroma samo nagib, ter zastekljenih vrat,
– horizontalnih in vertikalnih vrtljivih oken ter zastekljenih vrat,
– stransko vpetih krilnih oken in zgoraj vpetih oken ter zastekljenih vrat (odpiranje navzven),
se ta del standarda EN 13126 uporablja le, če se odpiranje preprečuje v okviru specifikacije v dodatku A, E ali G standarda EN 1191:2012 v skladu s predvideno uporabo, kot jo določa proizvajalec.

General Information

Status
Published
Publication Date
18-Jan-2015
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
18-Dec-2014
Due Date
22-Feb-2015
Completion Date
19-Jan-2015

Relations

Buy Standard

Standard
EN 13126-5:2012+A1:2015
English language
22 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Baubeschläge - Beschläge für Fenster und Fenstertüren - Anforderungen und Prüfverfahren - Teil 5: Vorrichtungen zur Begrenzung des Öffnungswinkels von FensternQuincaillerie pour le bâtiment - Exigences et méthodes d'essai des ferrures de fenêtres et portes-fenêtres - Partie 5: Dispositifs limiteurs d’ouverture des fenêtres et portes-fenêtresBuilding hardware - Hardware for windows and door height windows - Requirements and test methods - Part 5: Devices that restrict the opening of windows and door height windows91.190Stavbna opremaBuilding accessoriesICS:Ta slovenski standard je istoveten z:EN 13126-5:2011+A1:2014SIST EN 13126-5:2012+A1:2015en,fr,de01-februar-2015SIST EN 13126-5:2012+A1:2015SLOVENSKI
STANDARD



SIST EN 13126-5:2012+A1:2015



EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 13126-5:2011+A1
November 2014 ICS 91.190 Supersedes EN 13126-5:2011English Version
Building hardware - Hardware for windows and door height windows - Requirements and test methods - Part 5: Devices that restrict the opening of windows and door height windows
Quincaillerie pour le bâtiment - Exigences et méthodes d'essai des ferrures de fenêtres et portes-fenêtres - Partie 5: Dispositifs limiteurs d'ouverture des fenêtres et portes-fenêtres
Baubeschläge - Beschläge für Fenster und Fenstertüren - Anforderungen und Prüfverfahren - Teil 5: Vorrichtungen zur Begrenzung des Öffnungswinkels von Fenstern This European Standard was approved by CEN on
and includes Amendment 1 approved by CEN on 22 September 2014.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2014 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 13126-5:2011+A1:2014 ESIST EN 13126-5:2012+A1:2015



EN 13126-5:2011+A1:2014 (E) 2 Contents Page Foreword .3 1 Scope .4 2 Normative references .4 3 Terms and definitions .4 4 Classification .5 4.1 General .5 4.2 Category of use (1 – first digit) .5 4.3 Durability (2 – second digit) .5 4.4 Mass (3 – third digit) .5 4.5 Fire resistance (4 – fourth digit) .5 4.6 Safety in use (5 – fifth digit) .5 4.7 Corrosion resistance (6 – sixth digit) .6 4.8 Security (7 – seventh digit) .6 4.9 Application (8 – eighth digit) .6 4.10 Test sizes – Size limitations (9 – ninth digit) .7 4.11 Example of classification for devices that restrict the opening of windows .8 5 Requirements .8 5.1 General .8 5.2 Initial opening test .9 5.3 Durability test .9 5.4 Mechanical strength test . 10 5.5 Static load test . 10 5.6 Percussion test . 11 5.7 Impact test . 11 5.8 Cutting test . 11 6 Test equipment . 12 7 Test methods . 12 7.1 Samples . 12 7.2 Initial Opening test procedure . 12 7.3 Durability test . 13 7.4 Mechanical Strength test . 14 7.5 Static Load test procedure . 15 7.6 Percussion test procedure . 15 7.7 Impact test procedure . 15 7.8 Cutting test procedure . 15 7.9 Corrosion resistance . 16 Annex A (informative)
Test equipment . 17 Annex B (normative)
Test flow chart . 21 Bibliography . 22
SIST EN 13126-5:2012+A1:2015



EN 13126-5:2011+A1:2014 (E) 3 Foreword This document (EN 13126-5:2011+A1:2014) has been prepared by Technical Committee CEN/TC 33 “Doors, windows, shutters, building hardware and curtain walling”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by May 2015, and conflicting national standards shall be withdrawn at the latest by May 2015. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights. This document supersedes !EN 13126-5:2011". This document includes Amendment 1 approved by CEN on 2014-09-22. The start and finish of text introduced or altered by amendment is indicated in the text by tags !". A full contribution to the preparation of this European Standard has been made by the European manufacturers’ organization "ARGE" and national standards bodies. This European Standard is one of a series of European Standards dedicated to building hardware products. It is divided into many parts, the first part being common to all the other parts of this standards series, incorporating all types of hardware for windows and door height windows. Annex A (informative) of EN 13126-1 lists the titles of all parts of this European Standard and refers to their different window opening-type applications. Annex B (informative) of EN 13126-1 provides a list of the elements of components used on the various types of window opening functions. The performance tests incorporated in this standard are considered to be reproducible and as such will provide a consistent and objective assessment of the performance of these products. !deleted text" According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. SIST EN 13126-5:2012+A1:2015



EN 13126-5:2011+A1:2014 (E) 4 1 Scope !This Part of EN 13126 specifies requirements and test methods for durability, strength, security and functionality of devices that restrict the opening of windows and door height windows. On devices that restrict the opening of • Tilt&Turn, Tilt-First, Turn-Only, or Tilt-Only windows and door-height windows • horizontal and vertical pivot windows and door height windows • side-hung Casements and top–hung windows and door height windows (opening outwards) this part of EN 13126 only applies, if a restriction of the opening occurs within the specification in Annex A, E or G of EN 1191:2012 in accordance with the intended use specified by the manufacturer." NOTE 1 Restrictors and reverse restrictors can be either a separate item of hardware or an integral part of hardware, for example a part of the operating gear or an integral part of a hinge. NOTE 2 Windows may be fitted with more than one restrictor. NOTE 3 The requirements included within this standard take the needs for child safety into consideration, child protective window restrictors intended to be installed by the end consumers are beyond the scope of this standard. Therefore, for the DIY market refer to PC398 and !EN 16281". 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 1670, Building hardware - Corrosion resistance - Requirements and test methods EN 12519, Windows and pedestrian doors - Terminology EN 13049, Windows - Soft and heavy body impact - Test method, safety requirements and classification EN 13126-1, Building hardware - Hardware for windows and door height windows - Requirements and test methods - Part 1: Requirements common to all types of hardware !CEN/TR 13387, Child use and care articles - Safety guidelines" ISO 8317, Child-resistant packaging — Requirements and testing procedures for reclosable packages 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 13126-1 and EN 12519 and the following apply. 3.1 limiting restrictor (including maximum opening stops) device intended to limit the movement of an active sash to a predetermined position SIST EN 13126-5:2012+A1:2015



EN 13126-5:2011+A1:2014 (E) 5 3.2 holding restrictor (including peg type casement stays) mechanical device which is intended to hold the active sash in a predetermined position 3.3 reverse restrictor mechanical device which holds a reversed active sash securely for cleaning 3.4 safety restrictor robust mechanical device intended to limit the initial movement of an active sash in a predetermined position, maximum 100 mm, to prevent accidental passage through the window 3.5 child safety restrictor !robust mechanical device intended to limit the initial movement of an active sash in a predetermined position, maximum 89 mm, to prevent the passage of small children (passage of small children aged from 9 to 12 months in accordance with CEN/TR 13387)" 4 Classification 4.1 General The classification for devices that restrict the opening of windows shall be in accordance with the requirements of EN 13126-1. 4.2 Category of use (1 – first digit) No marking is required for the category of use in accordance with EN 13126-1. 4.3 Durability (2 – second digit) Grades shall be in accordance with EN 13126-1. 4.4 Mass (3 – third digit) Grades shall be in accordance with EN 13126-1. 4.5 Fire resistance (4 – fourth digit) Grades shall be in accordance with EN 13126-1. 4.6 Safety in use (5 – fifth digit) One grade shall be identified in accordance with EN 13126-1. Hardware with safety requirements shall show a grade as generated from Table 1. The grade shall consist of two digits separated by a slash. The first of the digits shall represent the testing performed to conform to the selected safety requirements as shown in Table 2. The second of the digits shall represent the impact test drop height as shown in 5.7. SIST EN 13126-5:2012+A1:2015



EN 13126-5:2011+A1:2014 (E) 6 Table 1 — Safety in use grades Safety requirement grade Impact test drop height grade 1 : No requirements 0 : No requirements 2 : Safety requirements 1 : 200 mm 3 : Child safety requirements 2 : 300 mm
3 : 450 mm
4 : 700 mm
5 : 950 mm EXAMPLE Grade 3/2 – Child safety requirements. 300mm drop height for impact test. 4.7 Corrosion resistance (6 – sixth digit) Grades shall be in accordance with EN 13126-1. 4.8 Security (7 – seventh digit) No marking is required for the category of security in accordance with EN 13126-1. 4.9 Application (8 – eighth digit) The eighth digit shows a grade as indicated in Table 2 indicating the part of the standard which was used for testing the devices that restrict the opening of windows in accordance with EN 13126-1. Seven grades are identified. SIST EN 13126-5:2012+A1:2015



EN 13126-5:2011+A1:2014 (E) 7 Table 2 — Application grade
Safety in use grade (5th digit) 1
2
3
Application Grade (8th digit) 5/1 5/2 5/3
5/4 5/5
5/6 5/7 Clause Description Limiting restrictor Holding restrictor Reverse restrictor
Safety limiting restrictor Safety holding restrictor
Child safety limiting restrictor Child safety holding restrictor 5.2.2 Safety initial opening (max. 100 mm)
X X
5.2.3 Child safety initial opening (max. 89 mm)
X X 5.3.2 Restrictor operation cycle X X
X X
X X 5.3.3 Restrictor engage and release cycle X X X
X X
X X 5.4.2 Hold open strength 200 N
X
X
X 5.4.3 Restrictor strength 350 N X X X
X X
5.4.4 Child safety restrictor strength 500 N
X X 5.5 Static load
X X
X X 5.6 Percussion
X X 5.7 Impact
X X
X X 5.8 Cutting
X X
X X 4.10 Test sizes – Size limitations (9 – ninth digit) The ninth digit shows the test sizes in accordance with EN 13126-1 as follows: S.W. (sash width) in mm / S.H. (sash height) in mm EXAMPLE 600 S.W. x 1 200 S.H. NOTE The specified sizes are a test sizes only. It does not relate to the maximum sizes to which a window may be fabricated. The window test size shall be determined by reference to the relevant part of the standards series for that hardware type or in accordance with Table 3. SIST EN 13126-5:2012+A1:2015



EN 13126-5:2011+A1:2014 (E) 8 Table 3 — Test window size (S.W. x S.H.)
Test size A Test size B Test size C Test size D Test size E Side Hung / Vertical Pivot 600 x 1 200 900 x 1 200 1 200 x 1 200 1 800 x 1 200 2 300 x 1 200 Top Hung / Horizontal Pivot 1 200 x
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.