Small wastewater treatment systems for up to 50 PT - Part 7: Prefabricated tertiary treatment units

This European Standard specifies requirements, test methods, the marking and evaluation of conformity for a packaged and/or on-site assembled tertiary treatment unit for installation either separately or in a pre existing container (see 3.9). It applies for tertiary treatment units that are placed on the market as complete units used for the tertiary treatment of wastewater by biological, physical, chemical or electrical processes and coming from: a) products in accordance with EN 12566-3 or EN 12566-6; b) installations designed and constructed in accordance with CEN/TR 12566-5. Package and/or site assembled tertiary treatment units according to this standard consist of one or more watertight tanks without any direct infiltration into the ground, made of concrete, corrosion resistant or coated steel, un-plasticised poly-vinyl chloride (PVC-U), Polyethylene (PE), Glass Reinforced Thermosetting Plastics (GRP) based on polyester resin (UP) (GRP-UP) and Polypropylene (PP). This standard applies to tertiary treatment units for use above ground (outside the building) or buried in the ground where no vehicle loads are applied to the product. This standard does not apply to tertiary treatment systems forming part of products covered by EN 12566-3 and EN 12566-6. This standard does not cover the systems for micro-organism reduction.

Kleinkläranlagen für bis zu 50 EW - Teil 7: Im Werk vorgefertigte Einheiten für eine dritte Reinigungsstufe

Diese Europäische Norm legt Anforderungen, Prüfverfahren, die Kennzeichnung und die Konformitätsbewertung
für vorgefertigte und/oder vor Ort montierte Einheiten für eine dritte Reinigungsstufe fest, die
entweder für den separaten Einbau oder den Einbau in einen bestehenden Behälter (siehe 3.9) vorgesehen
sind.
Sie gilt für als vollständige Produkte auf den Markt gebrachte Einheiten für eine dritte Reinigungsstufe von
Schmutzwasser folgender Herkunft durch biologische, physikalische. chemische oder elektrische Verfahren:
a) Anlagen nach EN 12566-3 oder EN 12566-6;
b) Anlagen, die nach CEN/TR 12566-5 ausgelegt und gebaut wurden.
Vorgefertigte und/oder vor Ort montierte Einheiten für eine dritte Reinigungsstufe nach dieser Norm bestehen
aus einem oder mehreren wasserdichten Behälter(n) ohne direkte Bodeninfiltration, hergestellt aus Beton,
nichtrostendem oder beschichtetem Stahl, weichmacherfreiem Polyvinylchlorid (PVC-U), Polyethylen (PE),
glasfaserverstärktem duroplastischem Kunststoff (GFK) auf der Basis von Polyesterharz (UP) (GFK-UP) und
Polypropylen (PP).
Die vorliegende Norm gilt für Einheiten für eine dritte Reinigungsstufe, die für den Einsatz oberhalb des
Bodens (außerhalb von Gebäuden) oder dafür vorgesehen sind, an Stellen in den Boden eingebaut zu
werden, an denen das Produkt keinen Fahrzeuglasten ausgesetzt ist.
Diese Norm gilt nicht für Anlagen für eine dritte Reinigungsstufe, die Teil von Produkten nach EN 12566-3 und
EN 12566-6 sind.

Petites installations de traitement des eaux usées jusqu'à 50 PTE - Partie 7: Unités de traitement tertiaire préfabriquées

La présente Norme européenne spécifie les exigences, les méthodes d'essai, le marquage et l'évaluation de la conformité d'une unité de traitement tertiaire prête à l'emploi et/ou assemblée sur site pour une installation séparée ou dans un réservoir pré-existant (voir 3.9).
Elle s'applique aux unités de traitement tertiaire introduites sur le marché en tant qu'unités complètes pour le traitement tertiaire des eaux usées par processus biologique, physique, chimique ou électrique provenant de :
a)   produits conformes à l'EN 12566-3 ou à l'EN 12566-6 ;
b)   d'installations conçues et construites conformément au CEN/TR 12566-5.
Conformément à la présente norme, les unités de traitement tertiaire prêtes à l'emploi ou assemblées sur site comprennent un ou plusieurs réservoirs étanches sans aucune infiltration directe dans le sol, fabriqués en béton, en acier anticorrosif ou revêtu, en polychlorure de vinyle non plastifié (PVC-U), en polyéthylène (PE), en plastique renforcé à la fibre de verre (GRP) basé sur de la résine polyester (UP) (GRP-UP) et en polypropylène (PP).
La présente norme s'applique aux unités de traitement tertiaire pour une utilisation au-dessus du niveau du sol (à l'extérieur du bâtiment) ou enterrées à un emplacement où l’unité n’est pas soumise à des charges dues aux véhicules.
La présente norme ne s'applique pas aux systèmes de traitement tertiaire faisant partie des produits couverts par l'EN 12566-3 et l'EN 12566-6.

Male čistilne naprave do 50 PE - 7. del: Predizdelane terciarne čistilne enote

Ta evropski standard podaja zahteve, preskusne metode, označevanje in ocenjevanje skladnosti za pakirane in/ali na kraju samem sestavljene terciarne čistilne enote za namestitev posebej ali v obstoječe rezervoarje (glej 3.9). Uporablja se za terciarne čistilne enote, ki so na trgu na voljo kot celotne enote za terciarno čiščenje odpadne vode z biološkimi, fizičnimi, kemičnimi in električnimi postopki in izhajajo iz: a) izdelkov, ki so v skladu s standardom EN 12566-3 ali EN 12566-6; b) naprav, ki so načrtovane in izdelane v skladu s standardom CEN/TR 12566-5. Embalaža in/ali na kraju samem sestavljene terciarne čistilne enote, ki so v skladu s tem standardom, so sestavljene iz enega ali več vodotesnih rezervoarjev brez infiltracije v zemljo in so izdelane iz betona, prevlečenega ali proti koroziji odpornega jekla, neplastificiranega polivinilklorida (PVC-U), polietilena (PE), s steklenimi vlakni ojačanih duromernih materialov (GRP) na osnovi nenasičene poliestrske smole (UP) (GRP-UP) in polipropilena (PP). Ta standard se uporablja za terciarne čistilne enote, ki se uporabljajo nad zemljo (pred stavbo) ali so zakopane pod zemljo, kjer ni vozil, ki obremenjujejo izdelek. Ta standard se ne uporablja za sestavne dele terciarnih čistilnih sistemov, ki so obravnavani v standardih EN 12566-3 in EN 12566-6. Ta standard ne obravnava sistemov za znižanje števila mikroorganizmov.

General Information

Status
Withdrawn
Publication Date
13-May-2013
Withdrawal Date
27-Feb-2017
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
10-Jan-2017
Due Date
02-Feb-2017
Completion Date
28-Feb-2017

Relations

Buy Standard

Standard
EN 12566-7:2013
English language
40 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day
Standard – translation
EN 12566-7:2013
Slovenian language
39 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Kleinkläranlagen für bis zu 50 EW - Teil 7: Im Werk vorgefertigte Einheiten für eine dritte ReinigungsstufePetites installations de traitement des eaux usées jusqu'à 50 PTE - Partie 7: Unités de traitement tertiaire préfabriquéesSmall wastewater treatment systems for up to 50 PT - Part 7: Prefabricated tertiary treatment units13.060.30Odpadna vodaSewage waterICS:Ta slovenski standard je istoveten z:EN 12566-7:2013SIST EN 12566-7:2013en,de01-julij-2013SIST EN 12566-7:2013SLOVENSKI
STANDARD



SIST EN 12566-7:2013



EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 12566-7
April 2013 ICS 13.060.30 English Version
Small wastewater treatment systems for up to 50 PT - Part 7: Prefabricated tertiary treatment units
Petites installations de traitement des eaux usées jusqu'à 50 PTE - Partie 7: Unités de traitement tertiaire préfabriquées
Kleinkläranlagen für bis zu 50 EW - Teil 7: Vorgefertigte Anlagen für eine dritte Reinigungsstufe This European Standard was approved by CEN on 1 March 2013.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2013 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 12566-7:2013: ESIST EN 12566-7:2013



EN 12566-7:2013 (E) 2 Contents Page Foreword . 5 1 Scope . 7 2 Normative references . 7 3 Terms and definitions . 8 4 Symbols and abbreviations . 9 5 Nominal designation . 9 6 Requirements . 9 6.1 Design . 9 6.1.1 General . 9 6.1.2 Overall dimensions . 9 6.1.3 Inlets, outlets, internal pipework and connections . 9 6.1.4 Access . 10 6.2 Load bearing capacity . 10 6.2.1 General . 10 6.2.2 Load bearing capacity determined by calculation . 11 6.2.3 Load bearing capacity determined by testing . 11 6.3 Tertiary treatment efficiency . 13 6.3.1 General . 13 6.3.2 Tertiary treatment efficiency ratio . 13 6.4 Watertightness . 14 6.5 Power consumption . 14 6.6 Durability . 14 6.6.1 General . 14 6.6.2 Concrete, steel, PVC-U, PE, GRP . 14 6.6.3 PDCPD . 14 6.6.4 Flexible sheets . 15 6.7 Reaction to fire . 15 6.7.1 General . 15 6.7.2 Units classified as Class A1 without the need for testing . 15 6.7.3 Units classified according to the test results . 16 6.8 Dangerous substances . 16 7 Marking . 16 7.1 Marking of the unit . 16 7.2 Technical information accompanying the unit . 17 8 Evaluation of conformity. 18 8.1 General . 18 8.2 Initial type testing – Type testing . 18 8.2.1 General . 18 8.2.2 Sampling, testing and compliance criteria. 20 8.2.3 Test reports . 20 8.3 Factory production control (FPC) . 20 8.3.1 General . 20 8.3.2 Requirements . 20 8.3.3 Procedure for modifications . 22 8.3.4 Initial inspection of factory and of FPC . 23 8.3.5 Continuous surveillance of FPC . 23 9 Installation instructions . 23 10 Operation manual . 23 Annex A (normative)
Tertiary treatment efficiency test procedure . 24 SIST EN 12566-7:2013



EN 12566-7:2013 (E) 3 A.1 Preliminary requirements. 24 A.1.1 General . 24 A.1.2 Installation and commissioning. 24 A.1.3 Operation procedures during testing . 24 A.1.4 Data to be monitored . 24 A.2 Test procedure . 25 A.2.1 Time for establishment . 25 A.2.2 Influent characteristics . 25 A.2.3 Daily flow pattern for testing. 25 A.2.4 Test procedure . 26 A.2.5 Influent and effluent sampling . 27 A.3 Sample analysis . 27 A.4 Test report . 27 Annex B (normative)
Definition of processes . 29 Annex C (informative)
Analysis method . 30 Annex ZA (informative)
Clauses of this European Standard addressing the provisions of the EU Construction Products Directive . 31 ZA.1 Scope and relevant characteristics . 31 ZA.2 Procedure of attestation of conformity of units . 33 ZA.2.1 System of attestation of conformity . 33 ZA.2.2 EC declaration of conformity . 35 ZA.3 CE marking . 36 Bibliography . 39
Figures Figure 1 — Scheme related to the arrangement of the parts of EN 12566 . 6 Figure 2 — Pit test for open unit . 13 Figure ZA.1 — Example CE marking information on the prefabricated tertiary treatment unit . 36 Figure ZA.2 — Example CE marking given in the commercial documents accompanying the prefabricated tertiary treatment unit when phosphorus removal . 38
Tables Table 1 — Characteristics of flexible sheets . 15 Table 2 — Requirements for initial type tests of the tertiary treatment units . 19 Table 3 — Minimum frequency of FPC testing for the tertiary treatment units . 22 Table A.1 — Daily flow pattern . 25 Table A.2 — Time test procedures . 26 Table A.3 — Definitions of overloads. 27 Table C.1 — Analysis methods . 30 Table ZA.1 — Scope and relevant characteristics . 32 Table ZA.2 — Attestation of conformity system . 33 Table ZA.3.1 — Assignment of evaluation of conformity tasks for prefabricated tertiary treatment units under system 3 +1 a . 34 SIST EN 12566-7:2013



EN 12566-7:2013 (E) 4 Table ZA.3.2 — Assignment of evaluation of conformity tasks for prefabricated tertiary treatment units under system 3 + 3 a. 34 Table ZA.3.3 — Assignment of evaluation of conformity tasks for prefabricated tertiary treatment units under system 3 and 4a . 35
SIST EN 12566-7:2013



EN 12566-7:2013 (E) 5 Foreword This document (EN 12566-7:2013) has been prepared by Technical Committee CEN/TC 165 “Waste water engineering”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by October 2013, and conflicting national standards shall be withdrawn at the latest by October 2013. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s). For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of this document. The series EN 12566, Small wastewater treatment systems for up to 50 PT, contains the following parts (see Figure 1):  Part 1: Prefabricated septic tanks;  Part 3: Packaged and/or site assembled domestic wastewater treatment plants;  Part 4: Septic tanks assembled in situ from prefabricated kits;  Part 6: Prefabricated treatment unit used for septic tank effluent;  Part 7: Prefabricated tertiary treatment unit (this document). For filtration and infiltration systems, CEN/TC 165 decided to publish the following CEN Technical Reports, which are considered as code of practices and do not specify treatment requirements:  CEN/TR 12566-2, Small wastewater treatment systems for up to 50 PT — Part 2: Soil infiltration systems  CEN/TR 12566-5, Small wastewater treatment systems for up to 50 PT — Part 5: Pre-treated Effluent Filtration systems This European Standard provides the general requirements for tertiary packaged and/or site assembled treatment units used for the treatment of secondary effluent. According to the CEN-CENELEC Internal Regulations, the national standards organisations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.
SIST EN 12566-7:2013



EN 12566-7:2013 (E) 6
Key A raw domestic wastewater 1 prefabricated septic tank B septic tank effluent 2 soil infiltration system C treated infiltrated effluent 3 packaged and/or site assembled domestic wastewater treatment plant D treated wastewater 4 septic tank assembled in situ from prefabricated kit E tertiary treated wastewater 5 pre-treated effluent filtration system
6 prefabricated treatment unit used for septic tank effluent
7 prefabricated tertiary treatment unit National regulations may specify different arrangements between the products described in the standard series EN 12566. Figure 1 — Scheme related to the arrangement of the parts of EN 12566 SIST EN 12566-7:2013



EN 12566-7:2013 (E) 7 1 Scope This European Standard specifies requirements, test methods, the marking and evaluation of conformity for a packaged and/or site assembled tertiary treatment unit for installation either separately or in a pre-existing unit (see 3.9). It applies for tertiary treatment units that are placed on the market as complete units used for the tertiary treatment of domestic wastewater by biological, physical, chemical, electrical processes and coming from: a) units in accordance with EN 12566-3 or EN 12566-6; b) installations designed and constructed in accordance with CEN/TR 12566-5. Equivalent secondary treated effluent may come from existing systems. Package and/or site assembled tertiary treatment units according to this standard consist of one or more watertight tanks without any direct infiltration into the ground, made of concrete, corrosion resistant or coated steel, un-plasticised poly-vinyl chloride (PVC-U), polyethylene (PE), glass reinforced thermosetting plastics (GRP) based on polyester resin (UP) (GRP-UP), polypropylene (PP), polydicyclopentadiene (PDCPD) and flexible sheets (PEHD, PP, PVE and EPDM). NOTE Some product covered by this standard sold without a tank could be introduced in an existing tank. This standard applies to tertiary treatment units for use above ground (outside the building) or buried in the ground where no vehicle loads are applied to the unit. This standard does not apply to tertiary treatment systems forming part of units covered by EN 12566-3 and EN 12566-6. This standard does not cover the systems for micro-organism reduction. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 1085:2007, Wastewater treatment — Vocabulary EN 12311-2, Flexible sheets for waterproofing — Determination of tensile properties — Part 2: Plastic and rubber sheets for roof waterproofing EN 12566-3:2005+A1:2009, Small wastewater treatment systems for up to 50 PT — Part 3: Packaged and/or site assembled domestic wastewater treatment plants EN 12566-6:2013, Small wastewater treatment systems for up to 50 PT — Part 6: Prefabricated treatment units for septic tank effluent EN 13501-1, Fire classification of construction products and building elements — Part 1: Classification using data from reaction to fire tests EN 14150, Geosynthetic barriers — Determination of permeability to liquids EN ISO 527 (all parts), Plastics — Determination of tensile properties (ISO 527) EN ISO 2555, Plastics — Resins in the liquid state or as emulsions or dispersions — Determination of apparent viscosity by the Brookfield Test method (ISO 2555) SIST EN 12566-7:2013



EN 12566-7:2013 (E) 8 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 12566-3:2005+A1:2009,
EN 12566-6:2013, EN 1085:2007 and the following apply. 3.1 tertiary treatment additional treatment process which results in further purification than that obtained by applying primary and secondary treatment Note 1 to entry: It is recommended that the expression for the treatment, e.g. nitrogen removal, phosphorus removal, polishing effects, suspended solid removal, is used since in some case the tertiary treatment can also be integrated in the secondary treatment. 3.2 packaged unit prefabricated factory-built unit 3.3 site assembled unit unit composed of prefabricated components assembled on site coming from one manufacturer 3.4 biological processes processes in which the treatment is mainly carried out by micro-organism activity 3.5 physical processes processes in which the treatment is mainly carried out by using the physical properties of a media 3.6 chemical processes processes in which the treatment is mainly carried out by the addition of chemical agents 3.7 electrical processes processes in which the treatment is mainly carried out by the use of electricity 3.8 unit family group of units produced by one manufacturer for which the test results for one or more characteristics from any one unit within the family are valid for all other units within this family Note 1 to entry: The definition of family could take into account at least similar shape, equipment, materials and conditions of end use. Note 2 to entry: The minimum level of performance is given by the test carried out on one unit of the family. 3.9 tertiary treatment retrofit unit tertiary treatment unit installed within an existing package and/or site assembled domestic wastewater treatment plant in accordance with EN 12566-3, or a secondary treatment unit in accordance with EN 12566-6 or a pre-treated effluent filtration system in accordance with CEN/TR 12566-5 Note 1 to entry: Where such a retrofit unit affects the declared performance of EN 12566-3 or EN 12566-6 unit in which it is installed, then the overall unit should be tested for its conformity with the relevant standard. 3.10
nominal designation appropriate values for parameters that represent the conditions for which the unit is designed by the manufacturer SIST EN 12566-7:2013



EN 12566-7:2013 (E) 9 4 Symbols and abbreviations BOD5 (or BOD7) Biochemical oxygen demand at 5 d (or 7 d) COD Chemical oxygen demand SS Suspended solids Total N Total nitrogen Total P Total phosphorus 5 Nominal designation The nominal designation of the tertiary treatment unit shall be declared as:  the hydraulic daily flow QN (m3/d) in nominal conditions;  and, for the parameters that are intended to be treated, the daily load of the unit in the nominal conditions for the declared parameters i.e. BOD5 and/or BOD7, and/or COD, and/or SS, and/or total phosphorus, and/or total nitrogen expressed in kg/d. EXAMPLE 1,4 m3/d and 0,02 kg/d of total phosphorus. 6 Requirements 6.1 Design 6.1.1 General Tertiary treatment units shall be designed to be structurally stable with the expected loads for the intended use. In addition, the units shall be durable, watertight and corrosion resistant. Where electrical, mechanical or hydraulic malfunction of the unit could lead to any failure, it shall be provided with an alarm to indicate such failure. The functionality of the alarm shall be verified as referenced in Table A.2. 6.1.2 Overall dimensions The overall dimensions of the prefabricated tertiary treatment unit (i.e. height, width, length, diameters, etc.) shall be measured and declared together with a tolerance. Assessment of overall dimensions shall be done by measurement with accuracy of ± 0,5 % of the dimension. 6.1.3 Inlets, outlets, internal pipework and connections The nominal diameters for inlet and outlet pipework of the prefabricated tertiary treatment unit shall be declared in the technical documentation. The hydraulic design of the unit, the internal pipework and the connections shall ensure that no accidental back-flows, blockage or surcharging occur during normal operation of the plant. Inlet and outlet pipes shall be compatible with standardised pipe systems. Assessment of inlets, outlets, internal pipework and connections shall be done by measurement with accuracy of ± 0,5 % of the dimension. SIST EN 12566-7:2013



EN 12566-7:2013 (E) 10 6.1.4 Access The prefabricated tertiary treatment unit shall be designed to restrict unauthorised access (e.g. locking mechanism). The design of the unit shall provide access to allow routine maintenance sampling, removal of sludge (where applicable), cleaning and maintenance. An opening with a dimension (i.e. length for rectangular section or diameter for circular section) of a minimum 400 mm shall be required. For open unit, access is not required. For installation purposes of open units, there may be local regulations for maintenance access.
The requirements to provide facility for the access of a person into the prefabricated tertiary treatment unit may depend on applicable regulations, valid in the member state for the intended end use conditions. For example, the minimum dimension of the opening for the access of a person in EN 476 is 600 mm. Extension shafts, where applicable, and access covers of the prefabricated tertiary treatment unit shall be designed to be fit for purpose.
The access dimensions shall be declared. Assessment of access dimension shall be done by measurement with accuracy of 0,5 % of the dimension. 6.2 Load bearing capacity 6.2.1 General For units not including a tank, load bearing capacity assessment is not required. Test methods and values for mechanical characteristics of the materials of the tank, used for calculation of the load bearing capacity of the tank, shall be in accordance with EN 12566-3:2005+A1:2009, Annex C. The prefabricated tertiary treatment units shall resist the loads resulting from handling, installation and use including desludging and maintenance, for their design life. For buried installation, the load bearing capacity of the prefabricated tertiary treatment unit (i.e. of the tank of this unit) shall be established:  either by calculation with the knowledge of basic data for material and loads (see 6.2.2);  or by test directly on the tank of the unit (see 6.2.3). Where the prefabricated tertiary treatment unit includes watertight extension shaft, and/or the unit is installed in a water table, the relevant loads at the maximum installed depth of the unit shall be taken into account and appropriate tests or calculations made to prove the load bearing capacity of the unit. The load bearing capacity is declared as:  maximum allowed height of backfill (m);  possibility to install the unit in water table or not, expressed as WET with the indication of the maximum height of watertable measured from the base of the unit or DRY. The load bearing capacity of prefabricated tertiary treatment units that are intended to be used only in non buried conditions shall be assessed only by calculation. For a unit with the container made of flexible sheets, the pit test only shall be used. SIST EN 12566-7:2013



EN 12566-7:2013 (E) 11 6.2.2 Load bearing capacity determined by calculation 6.2.2.1 General One of the following two methods may apply: a) Method 1: Indirect method usable for all materials by declaring the following parameters: 1) geometrical data of the unit: e.g. wall thickness, distance of ribs, shape…, 2) properties of the materials and components: all parameters given in chapter durability (6.6). The manufacturer shall provide in the installation instructions the height of backfill and the maximum height of water table for installation. b) Method 2: Directly declaring the performance using the applicable Eurocode: 1) Eurocode 2 for concrete (where applicable), 2) Eurocode 3 for steel (where applicable). The manufacturer shall provide the calculation results according to the relevant Eurocode in terms of height of backfill and possibility to install the plant in a wet or dry site with the indication of the he
...

SLOVENSKI SIST EN 12566-7

STANDARD
julij 2013












Male čistilne naprave do 50 PE –

7. del: Predizdelane terciarne čistilne enote


Small wastewater treatment systems for up to 50 PT –

Part 7: Prefabricated tertiary treatment units


Petites installations de traitement des eaux usées jusqu'à 50 PTE –

Partie 7: Unités de traitement tertiaire préfabriquées


Kleinkläranlagen für bis zu 50 EW –

Teil 7: Im Werk vorgefertigte Einheiten für eine dritte Reinigungsstufe





















Referenčna oznaka

ICS 13.060.30 SIST EN 12566-7:2013 (sl)


Nadaljevanje na straneh II in III ter od 1 do 37



© 2016-05. Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 12566-7 : 2013
NACIONALNI UVOD

Standard SIST EN 12566-7 (sl), Male čistilne naprave do 50 PE – 7. del: Predizdelane terciarne čistilne
enote, 2013, ima status slovenskega standarda in je istoveten evropskemu standardu EN 12566-7 (en,
de, fr), Small wastewater treatment systems for up to 50 PT – Part 7: Prefabricated tertiary treatment
units, 2013.

NACIONALNI PREDGOVOR

Evropski standard EN 12566-7:2013 je pripravil tehnični odbor Evropskega komiteja za standardizacijo
CEN/TC 165 Odvajanje in čiščenje odpadne vode. Slovenski standard SIST EN 12566-7:2013 je prevod
evropskega standarda EN 12566-7:2013. V primeru spora glede besedila slovenskega prevoda v tem
standardu je odločilen izvirni evropski standard v enem izmed treh uradnih jezikov CEN. Slovensko
izdajo standarda je potrdil Strokovni svet SIST za splošno področje.

Odločitev za izdajo tega standarda je oktobra 2012 sprejel Strokovni svet SIST za splošno področje.

ZVEZA S STANDARDI

S privzemom tega evropskega standarda veljajo za omejeni namen referenčnih standardov vsi
standardi, navedeni v izvirniku, razen tistih, ki so že sprejeti v nacionalno standardizacijo:
SIST EN 1085:2007 Čiščenje odpadne vode – Slovar
SIST EN 12311-2 Hidroizolacijski trakovi – Ugotavljanje nateznih lastnosti – 2. del: Polimerni
in elastomerni trakovi za tesnjenje streh
SIST EN 12566-3:2005+A1:2009  Male čistilne naprave do 50 PE – 3. del: Predizdelane in/ali na mestu
postavitve sestavljene čistilne naprave za gospodinjske odplake
SIST EN 12566-6:2013 Male čistilne naprave do 50 PE – 6. del: Predizdelane enote za obdelavo
grezničnih odplak
SIST EN 13501-1 Požarna klasifikacija gradbenih proizvodov in elementov stavb – 1. del:
Klasifikacija po podatkih iz preskusov odziva na ogenj
SIST EN 14150 Geosintetične ovire – Ugotavljanje prepustnosti za tekočine
SIST EN ISO 527 (vsi deli) Polimerni materiali – Določanje nateznih lastnosti (ISO 527)
SIST EN ISO 2555 Polimerni materiali – Tekoče smole, emulzije ali disperzije – Preskusna
metoda za določanje navidezne viskoznosti po Brookfieldu (ISO 2555)

OSNOVA ZA IZDAJO STANDARDA

– privzem standarda EN 12566-7:2013

OPOMBE

– Povsod, kjer se v besedilu standarda uporablja izraz “evropski standard”, v SIST EN 12566-7:2013
to pomeni “slovenski standard”.
– Uvod in nacionalni predgovor nista sestavni del standarda.

II

---------------------- Page: 2 ----------------------

SIST EN 12566-7 : 2013
– Ta nacionalni dokument je istoveten EN 12566-7:2013 in je objavljen z dovoljenjem
CEN
Upravni center
Avenue Marnix 17
B-1000 Bruselj

This national document is identical with EN 12566-7:2013 and is published with the permission of
CEN
Management Centre
Avenue Marnix 17
B-1000 Brussels



III

---------------------- Page: 3 ----------------------

EVROPSKI STANDARD EN ISO 12566-7
EUROPEAN STANDARD
NORME EUROPÉENNE
EUROPÄISCHE NORM april 2013


ICS 13.060.30




Slovenska izdaja

Male čistilne naprave do 50 PE –
7. del: Predizdelane terciarne čistilne enote

Small wastewater treatment Petites installations de traitement des Kleinkläranlagen für bis zu 50 EW
systems for up to 50 PT – eaux usées jusqu'à 50 PTE – – Teil 7: Im Werk vorgefertigte
Part 7: Prefabricated tertiary Partie 7: Unités de traitement tertiaire Einheiten für eine dritte
treatment units préfabriquées Reinigungsstufe




Ta evropski standard je CEN sprejel dne 1. marca 2013.

Člani CEN morajo izpolnjevati določila notranjih predpisov CEN/CENELEC, s katerimi je predpisano, da
mora biti ta evropski standard brez kakršnih koli sprememb sprejet kot nacionalni standard. Seznami
najnovejših izdaj teh nacionalnih standardov in njihovi bibliografski podatki so na voljo pri Upravnem
centru CEN-CENELEC ali članih CEN.

Ta evropski standard obstaja v treh uradnih izdajah (angleški, francoski in nemški). Izdaje v drugih
jezikih, ki jih člani CEN na lastno odgovornost prevedejo in izdajo ter prijavijo pri upravnem centru
CEN-CENELEC, veljajo kot uradne izdaje.

Člani CEN so nacionalni organi za standarde Avstrije, Belgije, Bolgarije, Cipra, Češke republike,
Danske, Estonije, Finske, Francije, Grčije, Hrvaške, Irske, Islandije, Italije, Latvije, Litve, Luksemburga,
Madžarske, Malte, Nekdanje jugoslovanske republike Makedonije, Nemčije, Nizozemske, Norveške,
Poljske, Portugalske, Romunije, Slovaške, Slovenije, Španije, Švedske, Švice, Turčije in Združenega
kraljestva.









CEN
Evropski komite za standardizacijo
European Committee for Standardization
Comité Européen de Normalisation
Europäisches Komitee für Normung

Upravni center: Avenue Marnix, 17, B-1050 Brussels


© 2013 CEN. Lastnice avtorskih pravic so vse države članice CEN Ref. oznaka: EN ISO 12566-7:2013 E

---------------------- Page: 4 ----------------------

SIST EN 12566-7 : 2013
VSEBINA Stran
Predgovor . 4
1 Področje uporabe . 6
2 Zveze s standardi . 6
3 Izrazi in definicije . 7
4 Simboli in kratice . 8
5 Nazivna oznaka . 8
6 Zahteve . 8
6.1 Projektiranje . 8
6.1.1 Splošno . 8
6.1.2 Skupne dimenzije . 8
6.1.3 Vtočne in iztočne odprtine, notranji cevovod ter priključki . 8
6.1.4 Dostop . 8
6.2 Obremenitvena zmogljivost . 9
6.2.1 Splošno . 9
6.2.2 Obremenitvena zmogljivost, določena z izračunom . 9
6.2.3 Obremenitvena zmogljivost, določena s preskušanjem . 10
6.3 Učinkovitost terciarnega čiščenja . 12
6.3.1 Splošno . 12
6.3.2 Stopnja učinkovitosti terciarnega čiščenja . 12
6.4 Vodotesnost . 12
6.5 Poraba energije . 13
6.6 Trajnost . 13
6.6.1 Splošno . 13
6.6.2 Beton, jeklo, PVC-U, PE, GRP . 13
6.6.3 PDCPD . 13
6.6.4 Hidroizolacijski trakovi . 13
6.7 Odziv na ogenj . 14
6.7.1 Splošno . 14
6.7.2 Enote, klasificirane kot razred A1, brez potrebe po preskušanju . 14
6.7.3 Enote, klasificirane v skladu z rezultati preskušanja . 14
6.8 Nevarne snovi . 15
7 Označevanje . 15
7.1 Označevanje enote . 15
7.2 Enoti priložene tehnične informacije, . 15
8 Vrednotenje skladnosti . 16
8.1 Splošno . 16
8.2 Začetno tipsko preskušanje – tipsko preskušanje . 16
8.2.1 Splošno . 16
8.2.2 Vzorčenje, preskušanje in merila skladnosti . 19
2

---------------------- Page: 5 ----------------------

SIST EN 12566-7 : 2013
8.2.3 Poročila o preskusih . 19
8.3 Kontrola proizvodnje v obratu (FPC) . 19
8.3.1 Splošno . 19
8.3.2 Zahteve . 19
8.3.3 Postopek za spremembe . 21
8.3.4 Začetni pregled obrata in kontrole proizvodnje v obratu . 22
8.3.5 Stalni nadzor nad kontrolo proizvodnje v obratu . 22
9 Navodila za vgradnjo . 22
10 Priročnik o obratovanju . 22
Dodatek A (normativni): Postopek preskusa učinkovitosti terciarnega čiščenja . 23
Dodatek B (normativni): Definicija procesov . 27
Dodatek C (informativni): Analizna metoda . 28
Dodatek ZA (informativni): Točke tega evropskega standarda, ki se nanašajo na določila
Direktive EU o gradbenih proizvodih . 29
Literatura. 37

3

---------------------- Page: 6 ----------------------

SIST EN 12566-7 : 2013
Predgovor

Ta dokument (EN 12566-7:2013) je pripravil tehnični odbor CEN/TC 165 Odvajanje in čiščenje odpadne
vode, katerega sekretariat vodi DIN.

Ta evropski standard mora dobiti status nacionalnega standarda z objavo istovetnega besedila ali z
razglasitvijo najpozneje do oktobra 2013. Do istega roka je treba umakniti tudi nacionalne standarde, ki
so v nasprotju s tem standardom.

Opozoriti je treba na možnost, da so lahko nekateri elementi tega dokumenta predmet patentnih pravic.
CEN [in/ali CENELEC] ne prevzema odgovornosti za identifikacijo nekaterih ali vseh takih patentnih
pravic.

Ta dokument je bil pripravljen na podlagi mandata, ki sta ga Evropska komisija in Evropsko združenje
za prosto trgovino podelila CEN, in podpira bistvene zahteve direktive (direktiv) EU.

Za povezavo z direktivami Evropske unije glej dodatek ZA, ki je sestavni del tega dokumenta.
Skupina standardov EN 12566, Male čistilne naprave do 50 PE, vključuje naslednje dele (glej sliko 1):
– 1. del: Predizdelane greznice
– 3. del: Predizdelane in/ali na mestu postavitve sestavljene čistilne naprave za gospodinjske
odplake
– 4. del: Montažne greznice, sestavljene na mestu vgradnje
– 6. del: Predizdelane enote za obdelavo grezničnih odplak
– 7. del: Predizdelane terciarne čistilne enote (ta dokument)

Za sisteme za filtriranje in infiltracijo je CEN/TC 165 objavil naslednji tehnični poročili CEN, ki se
upoštevata kot pravila ravnanja in ne določata zahtev za čiščenje:
– CEN/TR 12566-2, Male čistilne naprave do 50 PE – 2. del: Sistemi za infiltracijo v zemljo
– CEN/TR 12566-5, Male čistilne naprave do 50 PE – 5. del: Filtrirne naprave za predčiščene hišne
odpadne vode

Ta evropski standard določa splošne zahteve za predizdelane in/ali na mestu postavitve sestavljene
terciarne čistilne naprave za čiščenje sekundarne odpadne vode.

V skladu z notranjimi predpisi CEN-CENELEC morajo ta evropski standard obvezno uvesti nacionalne
organizacije za standardizacijo naslednjih držav: Avstrije, Belgije, Bolgarije, Cipra, Češke republike,
Danske, Estonije, Finske, Francije, Grčije, Hrvaške, Irske, Islandije, Italije, Latvije, Litve, Luksemburga,
Madžarske, Malte, Nekdanje jugoslovanske republike Makedonije, Nemčije, Nizozemske, Norveške,
Poljske, Portugalske, Romunije, Slovaške, Slovenije, Španije, Švedske, Švice, Turčije in Združenega
kraljestva.
4

---------------------- Page: 7 ----------------------

SIST EN 12566-7 : 2013



Legenda:
A  surova gospodinjska odpadna voda  1  predizdelana greznica
B  odpadna voda iz greznice 2  sistem za infiltracijo v tla
C  očiščena infiltrirana odpadna voda  3  predizdelana in/ali na mestu vgradnje sestavljena čistilna
naprava za gospodinjsko odpadno vodo
D  očiščena odpadna voda
4  montažna greznica, sestavljena na mestu vgradnje
E  terciarno očiščena odpadna voda
  5  filtrirni sistem za predčiščeno odpadno vodo
  6  predizdelana čistilna enota za odpadno vodo iz greznice
  7  predizdelana terciarna čistilna enota

Nacionalni predpisi lahko določajo drugačne razporeditve med proizvodi, opisanimi v standardih skupine
EN 12566.

Slika 1: Shema, povezana z razporeditvijo delov standarda EN 12566

5

---------------------- Page: 8 ----------------------

SIST EN 12566-7 : 2013
1 Področje uporabe

Ta evropski standard določa zahteve, preskusne metode, označevanje in vrednotenje skladnosti
predizdelanih in/ali na mestu postavitve sestavljenih terciarnih čistilnih enot za namestitev posebej ali v
obstoječe enote (glej 3.9).

Uporablja se za terciarne čistilne enote, ki so na trgu na voljo kot kompletne enote za terciarno čiščenje
gospodinjske odpadne vode z biološkimi, fizikalnimi, kemijskimi in električnimi postopki ter izhajajo:
a) iz enot v skladu s standardom EN 12566-3 ali EN 12566-6,
b) iz naprav, projektiranih in izdelanih v skladu s standardom CEN/TR 12566-5.

Enakovredne sekundarno očiščene odpadne vode lahko izhajajo iz obstoječih sistemov.

Predizdelane in/ali na mestu postavitve sestavljene terciarne čistilne enote, ki so v skladu s tem
standardom, so sestavljene iz enega ali več vodotesnih rezervoarjev brez neposredne infiltracije v tla in
izdelane iz betona, prevlečenega ali proti koroziji odpornega jekla, neplastificiranega polivinilklorida
(PVC-U), polietilena (PE), s steklenimi vlakni ojačenih duromernih materialov (GRP) na osnovi
nenasičene poliestrske smole (UP) (GRP-UP), polipropilena (PP), polidiciklopentadiena (PDCPD) ali
hidroizolacijskih trakov (PEHD, PP, PVE in EPDM).

OPOMBA: Nekateri izdelki, obravnavani v tem standardu, ki se prodajajo brez rezervoarja, se lahko uporabijo v povezavi z
obstoječim rezervoarjem.
Ta standard se uporablja za terciarne čistilne enote, ki se uporabljajo nad površino (zunaj stavb) ali so
zakopane pod površino, kjer niso izpostavljene obremenitvam vozil.

Ta standard se ne uporablja za sestavne dele terciarnih čistilnih naprav, ki so obravnavani v standardih
EN 12566-3 in EN 12566-6.

Ta standard ne obravnava sistemov za znižanje števila mikroorganizmov.

2 Zveze s standardi

Za uporabo tega dokumenta so, delno ali v celoti, nujni naslednji referenčni dokumenti. Pri datiranih
sklicevanjih se uporablja samo navedena izdaja. Pri nedatiranih sklicevanjih se uporablja zadnja izdaja
referenčnega dokumenta (vključno z morebitnimi dopolnili).
EN 1085:2007 Čiščenje odpadne vode – Slovar

EN 12311-2 Hidroizolacijski trakovi – Ugotavljanje nateznih lastnosti – 2. del: Polimerni
in elastomerni trakovi za tesnjenje streh

EN 12566-3:2005+A1:2009 Male čistilne naprave do 50 PE – 3. del: Predizdelane in/ali na mestu
postavitve sestavljene čistilne naprave za gospodinjske odplake

EN 12566-6:2013 Male čistilne naprave do 50 PE – 6. del: Predizdelane enote za obdelavo
grezničnih odplak

EN 13501-1 Požarna klasifikacija gradbenih proizvodov in elementov stavb – 1. del:
Klasifikacija po podatkih iz preskusov odziva na ogenj

EN 14150 Geosintetične ovire – Ugotavljanje prepustnosti za tekočine

EN ISO 527 (vsi deli) Polimerni materiali – Ugotavljanje nateznih lastnosti (ISO 527)

EN ISO 2555 Polimerni materiali – Tekoče smole, emulzije ali disperzije – Preskusna
metoda za določanje navidezne viskoznosti po Brookfieldu (ISO 2555)


6

---------------------- Page: 9 ----------------------

SIST EN 12566-7 : 2013
3 Izrazi in definicije

V tem dokumentu se uporabljajo izrazi in definicije, navedeni v EN 12566-3:2005+A1:2009, EN 12566-
6:2013, EN 1085:2007, ter naslednji izrazi in definicije:

3.1
terciarno čiščenje
dodaten postopek čiščenja za dodatno čiščenje primarno in sekundarno očiščene odpadne vode

OPOMBA 1: Priporoča se uporaba izraza za čiščenje (npr. odstranjevanje dušika, odstranjevanje fosforja, učinki poliranja,
odstranjevanje neraztopljenih snovi), saj je v nekaterih primerih lahko postopek terciarnega čiščenja vključen v
postopek sekundarnega čiščenja.
3.2
predizdelana enota
tovarniško predizdelana enota

3.3
na mestu vgradnje sestavljena enota
enota, sestavljena na mestu vgradnje iz predizdelanih sestavnih delov istega proizvajalca

3.4
biološki procesi
procesi, v katerih se čiščenje izvaja v glavnem z dejavnostjo mikroorganizmov

3.5
fizikalni procesi
procesi, v katerih se čiščenje izvaja v glavnem z uporabo fizikalnih lastnosti medija

3.6
kemijski procesi
procesi, v katerih se čiščenje izvaja v glavnem z dodajanjem kemijskih sredstev

3.7
električni procesi
procesi, v katerih se čiščenje izvaja v glavnem z uporabo elektrike

3.8
skupina enot
skupina enot, ki jih je izdelal isti proizvajalec in za katere rezultati preskusa za vsaj eno lastnost
katerekoli enote iz skupine veljajo za vse ostale enote v skupini

OPOMBA 1: Definicija skupine lahko vključuje vsaj podobno obliko, opremo, materiale in pogoje končne uporabe.
OPOMBA 2: Najmanjša raven zmogljivosti se določi na podlagi preskusa ene od enot v skupini.
3.9
terciarna čistilna enota za rekonstrukcijo
terciarna čistilna enota, vgrajena v obstoječo predizdelano in/ali na mestu vgradnje sestavljeno čistilno
napravo za gospodinjsko odpadno vodo v skladu z EN 12566-3 ali sekundarna čistilna enota v skladu
z EN 12566-6 ali filtrirna naprava za predčiščeno gospodinjsko odpadno vodo v skladu s CEN/TR
12566-5

OPOMBA 1: Če enota za rekonstrukcijo vpliva na deklarirane lastnosti enote v skladu z EN 12566- 3 ali EN 12566-6, v katero je
vgrajena, je treba preskusiti celotno enoto in preveriti njeno skladnost z ustreznim standardom.
3.10
nazivna oznaka
ustrezne vrednosti parametrov, ki določajo pogoje, za katere je proizvajalec projektiral enoto

7

---------------------- Page: 10 ----------------------

SIST EN 12566-7 : 2013
4 Simboli in kratice

BKP5 (ali BKP7) biokemijska potreba po kisiku po 5 (ali 7) dneh
KPK kemijska potreba po kisiku
NS neraztopljene snovi
celotni N celotni dušik
celotni P celotni fosfor

5 Nazivna oznaka

Nazivna oznaka terciarne čistilne enote mora biti navedena kot:
3
– dnevni hidravlični pretok Q N (m /d) v običajnih pogojih in

– (za parametre, predvidene za čiščenje) dnevna obremenitev enote v običajnih pogojih za navedene
parametre, tj. BKP5 in/ali BKP7 in/ali KPK in/ali neraztopljene snovi in/ali celotni fosfor in/ali celotni
dušik, izražen v kg/d.

3
PRIMER: 1,4 m /d in 0,02 kg/d za celotni fosfor.

6 Zahteve

6.1 Projektiranje

6.1.1 Splošno

Terciarne čistilne enote morajo imeti stabilno konstrukcijo in prenesti pričakovane obremenitve v okviru
predvidene uporabe. Poleg tega morajo biti enote trajne, vodotesne in odporne proti koroziji.

Kjer lahko električne, mehanske ali hidravlične okvare enote povzročijo morebitno odpoved, mora biti
enota opremljena z alarmom, ki opozarja na tovrstne odpovedi. Delovanje alarma mora biti preverjeno,
kot je navedeno v preglednici A.2.

6.1.2 Skupne dimenzije

Skupne dimenzije predizdelane terciarne čistilne enote (npr. višina, širina, dolžina, premeri itd.) morajo
biti izmerjene in navedene skupaj s tolerancami.

Skupne dimenzije morajo biti ocenjene z meritvami s točnostjo ±0,5 % pri posamezni dimenziji.

6.1.3 Vtočne in iztočne odprtine, notranji cevovod ter priključki

V tehnični dokumentaciji je treba navesti nazivne premere vtočnih in iztočnih cevi predizdelane terciarne
čistilne enote. Hidravlična zasnova enote, notranji cevovod in priključki morajo preprečevati kakršnekoli
naključne povratne tokove, zamašitve ali preobremenitve pri običajnem obratovanju enote.

Vtočne in iztočne cevi morajo biti združljive s standardiziranimi cevnimi sistemi.

Dimenzije vtočnih in iztočnih cevi, notranjega cevovoda in priključkov morajo biti ocenjene z meritvami
s točnostjo ±0,5 % pri posamezni dimenziji.

6.1.4 Dostop

Predizdelana terciarna čistilna enota mora biti projektirana tako, da onemogoča nepooblaščen dostop
(npr. z zaklepnim mehanizmom).
8

---------------------- Page: 11 ----------------------

SIST EN 12566-7 : 2013
Zasnova enote mora omogočati dostop za potrebe rednega vzdrževalnega vzorčenja, odvzemanja blata
(kjer je to primerno) ter čiščenja in vzdrževanja. Na voljo mora biti odprtina z dimenzijo (tj. dolžina pri
pravokotni površini ali premer pri krožni površini) vsaj 400 mm. Dostopna odprtina pri odprti enoti ni
potrebna.

Za namestitve odprtih enot lahko obstajajo lokalni predpisi za dostop za vzdrževanje.

Zahteve za zagotavljanje dostopa osebe v predizdelano terciarno čistilno enoto so lahko odvisne od
veljavnih predpisov, ki urejajo pogoje predvidene končne uporabe enote v posamezni državi članici.
(npr. najmanjša dolžina odprtine za dostop osebe v skladu z EN 476 je 600 mm).

Dostopni jaški (kjer je to primerno) in dostopni pokrovi predizdelanih terciarnih čistilnih enot morajo biti
primerni za svoj namen.

Navesti je treba dimenzije dostopnih odprtin. Dimenzije dostopne odprtine morajo biti ocenjene z
meritvami s točnostjo 0,5 % pri posamezni dimenziji.

6.2 Obremenitvena zmogljivost

6.2.1 Splošno

Za enote, ki ne vključujejo rezervoarja, ocena obremenitvene zmogljivosti ni zahtevana.

Preskusne metode in vrednosti za mehanske lastnosti materialov rezervoarja, ki se uporabljajo za izračun
obremenitvene zmogljivosti rezervoarja, morajo biti v skladu z EN 12566-3:2005+A1:2009, dodatek C.

Predizdelane terciarne čistilne enote morajo v svoji predvideni življenjski dobi prenesti obremenitve, ki
so posledica obratovanja, vgradnje in uporabe, vključno z odvzemanjem blata in vzdrževanjem.

Za zakopane naprave je treba določiti obremenitveno zmogljivost predizdelane terciarne čistilne enote
(tj. njenega rezervoarja):
– z izračunom ob poznavanju osnovnih podatkov za material in obremenitve (glej 6.2.2)
– ali s preskusom neposredno na rezervoarju enote (glej 6.2.3).

Če predizdelana terciarna čistilna enota vključuje vodotesni jašek in/ali je vgrajena na nivoju vodne
gladine, je treba upoštevati ustrezne obremenitve pri največji vgradni globini enote in opraviti ustrezne
preskuse ali izračune za določitev obremenitvene zmogljivosti enote.

Obremenitvena zmogljivost je opredeljena kot:
– največja dovoljena višina zasipa (m),
– možnost vgradnje enote na nivoju vodne gladine z oznako VLAŽNO in navedbo največje višine
vodne gladine, izmerjene od dna enote, ali z oznako SUHO.

Obremenitveno zmogljivost predizdelanih terciarnih čistilnih enot, ki so predvidene samo za uporabo kot
nezakopane, je treba oceniti izključno z izračunom.

Za enoto z vsebnikom iz hidroizolacijskih trakov je treba uporabiti izključno preskus v jami.

6.2.2 Obremenitvena zmogljivost, določena z izračunom

6.2.2.1 Splošno

Uporabi se lahko ena od naslednjih dveh metod:
a) 1. metoda: posredna metoda, uporabna za vse materiale, z navedbo naslednjih parametrov:
1) geometrijski podatki enote: npr. debelina stene, razdalja med rebri, oblika itd.,
9

---------------------- Page: 12 ----------------------

SIST EN 12566-7 : 2013
2) lastnosti materialov in sestavnih delov: vsi parametri, podani v točki o trajnosti (6.6).
Proizvajalec mora v navodilih za vgradnjo navesti višino zasipa in največjo višino vodne gladine za
vgradnjo.
b) 2. metoda: neposredna navedba učinkovitosti delovanja po ustreznem evrokodu:
1) Evrokod 2 za beton (kjer je to primerno);
2) Evrokod 3 za jeklo (kjer je to primerno).

Proizvajalec mora navesti rezultate izračuna v skladu z ustreznim evrokodom v obliki višine zasipa in
možnosti za namestitev naprave na suhem ali vlažnem mestu, pri čemer mora biti navedena višina
vodne gladine, izmerjena od dna naprave.

OPOMBA: Če se za oceno obremenitvene zmogljivosti uporabi 1. metoda, priglašeni organ preveri dimenzije izdelka in
lastnosti materiala. Če se uporabi 2. metoda, priglašeni organ preveri vhodne podatke za izračun, preveri izračun
in potrdi rezultate v poročilu o začetnem tipskem preskušanju.
6.2.2.2 Obremenitve zasipa

Izračun obremenitev zasipa je treba opraviti v skladu z EN 12566-3:2005+A1:2009, 6.2.1.2.

6.2.2.3 Hidrostatične obremenitve

Izračunati je treba navpično in vodoravno komponento hidrostatičnih obremenitev v skladu z EN 12566-
3:2005+A1:2009, 6.2.1.3.

6.2.2.4 Obremenitve pešcev

2
Če je višina zasipa (h) ≤ 1 m, je treba za obremenitve pešcev upoštevati vrednost 2,5 N/m . Če je višina
več kot 1 m, se predvideva, da so obremenitve pešcev v primerjavi z drugimi obremenitvami
zanemarljive, zato jih ni treba upoštevati.

6.2.3 Obremenitvena zmogljivost, določena s preskušanjem

Obremenitveno zmogljivost predizdelane terciarne čistilne enote je treba določiti na podlagi odpornosti
proti lomljenju ali deformacije pri največji obremenitvi v skladu z EN 12566-3:2005+A1:2009, dodatek
C.

Z rezultati preskušanja je treba zagotoviti, da je obremenitvena zmogljivost v skladu z navedeno
obremenitvijo.
– Preskus odpornosti proti lomljenju (EN 12566-3:2005+A1:2009, C.2 in C.3): navedena vrednost
obremenitve mora biti manjša ali enaka vrednosti obremenitve ob odpovedi, deljeni s faktorjem
najmanj 1,6.