Plastics - Determination of Izod impact strength (ISO 180:2000)

1.1 This International Standard specifies a method for determining the Izod impact strength of plastics under defined conditions. A number of different types of specimen and test configurations are defined. Different test parameters are specified according to the type of material, the type of test specimen and the type of notch.
1.2 The method is used to investigate the behaviour of specified types of specimen under the impact conditions defined and for estimating the brittleness or toughness of specimens within the limitations inherent in the test conditions.
1.3 The method is suitable for use with the following range of materials:
_ rigid thermoplastic moulding and extrusion materials, including filled and reinforced compounds in addition to unfilled types; rigid thermoplastics sheets;
_ rigid thermosetting moulding materials, including filled and reinforced compounds; rigid thermosetting sheets, including laminates;
_ fibre-reinforced thermosetting and thermoplastic composites incorporating unidirectional or non-unidirectional reinforcements such as mat, woven fabrics, woven rovings, chopped strands, combination and hybrid reinforcements, rovings and milled fibres and sheet made from pre-impregnated materials (prepregs);
_ thermotropic liquid-crystal polymers.
1.4 The method is not normally suitable for use with rigid cellular materials and sandwich structures containing cellular material. Also, notched specimens are not normally used for long-fibre-reinforced composites or thermotropic liquid-crystal polymers.
1.5 The method is suited to the use of specimens which may be either moulded to the chosen dimensions, machined from the central portion of a standard multipurpose test specimen (see ISO 3167) or machined from finished or semifinished products such as mouldings, laminates and extruded or cast sheet.
1.6 The method specifies preferred dimensions for the test specimen. Tests which are carried out on specimens of different dimensions or with different notches, or specimens which are prepared under different conditions, may produce results which are not comparable. Other factors, such as the energy capacity of the apparatus, its impact velocity and the conditioning of the specimens can also influence the results. Consequently, when comparative data are required, these factors must be carefully controlled and recorded.
1.7 The method should not be used as a source of data for design calculations. Information on the typical behaviour of a material can be obtained, however, by testing at different temperatures, by varying the notch radius and/or the thickness and by testing specimens prepared under different conditions.

Kunststoffe - Bestimmung der Izod-Schlagzähigkeit (ISO 180:2000)

Diese Internationale Norm gibt ein Verfahren an für die Bestimmung der Izod-Schlagzähigkeit von Kunststoffen unter festgelegten Bedingungen. Eins Anzahl unterschiedlicher Probekörper und Prüfanordnungen werden festgelegt. Es werden Prüfbedingungen festgelegt, die sich je nach dem Werkstoff in dem Probekörper Typ und der Kerbform unterscheiden. Das Prüfverfahren erlaubt das Verhalten festgelegter Probekörper bei den festgelegten Schlagbedingungen zu untersuchen und die Sprödigkeit oder Zähigkeit von Probekörpern innerhalb der Grenzen der Prüfbedingungen festzustellen.

Plastiques - Détermination de la résistance au choc Izod (ISO 180:2000)

Polimerni materiali - Ugotavljanje udarne žilavosti po Izodu (ISO 180:2000)

1.1 Ta mednarodni standard določa metodo za ugotavljanje udarne žilavosti polimernih materialov po Izodu pod določenimi pogoji. Določeno je več različnih vrst vzorcev in preskusnih konfiguracij. Različni preskusni parametri so določeni glede na vrsto materiala, vrsto preskusnega vzorca in vrsto zareze.
1.2 Metoda se uporablja za preiskovanje vedenja določenih vrst vzorcev pod določenimi udarnimi pogoji in ocenjevanje krhkosti ali žilavosti vzorcev v okviru omejitev preskusnih pogojev.
1.3 Metoda je ustrezna za naslednje vrste materialov:
_ trdi plastomerni materiali za oblikovanje in materiali za ekstrudiranje, vključno s polnjenimi, nepolnjenimi in ojačanimi spojinami; trde plastomerne plošče;
_ trdi termoreaktivni materiali za oblikovanje, vključno s polnjenimi in ojačanimi spojinami; trde termoreaktivne plošče, vključno z laminati;
_ z vlakni ojačani termoreaktivni in plastomerni kompoziti, ki vsebujejo enosmerne ali neenosmerne ojačitve, kot so preproge, tkanine, tkane snopiče, rezane niti, kombinacijske in hibridne ojačitve, snopiči in brušena vlakna in plošče iz predhodno impregniranih materialov;
_ termotropni polimeri iz tekočih kristalov.
1.4 Metoda običajno ni primerna za trde penjene materiale ali strukture tipa »sendvič«, ki vsebujejo penjeni material. Poleg tega se zarezani vzorci običajno ne uporabljajo za kompozite, ojačane z dolgimi vlakni, ali termotropne polimere iz tekočih kristalov.
1.5 Metoda je primerna za uporabo pri vzorcih, ki so oblikovani na želene dimenzije, strojno izdelani iz osrednjega dela standardnega večnamenskega preskusnega vzorca (glej ISO 3167) ali strojno izdelani iz končnih izdelkov ali polizdelkov, kot so oblikovanci, laminati in ekstrudirane ali vlite plošče.
1.6 Metoda določa prednostne dimenzije preskusnih vzorcev. Preskusi, ki se izvajajo na vzorcih drugih velikosti ali z drugačnimi zarezami, ali na vzorcih, ki so pripravljeni pod drugačnimi pogoji, lahko dajo rezultate, ki niso primerljivi. Na rezultate lahko vplivajo tudi drugi dejavniki, kot so energijska zmogljivost aparata, njegova udarna hitrost in obdelava vzorcev. Če so potrebni primerjalni podatki, je potrebno te dejavnike natančno nadzirati in zabeležiti.
1.7 Metode se ne sme uporabljati kot vir podatkov za izračune v okviru zasnove. Podatke o značilnem vedenju materiala je mogoče pridobiti s preskušanjem pri različnih temperaturah, spreminjanjem premera zareze in/ali debeline ter preskušanjem vzorcev, pripravljenih pri različnih pogojih.

General Information

Status
Withdrawn
Publication Date
31-May-2001
Withdrawal Date
05-Jan-2020
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
30-Dec-2019
Due Date
22-Jan-2020
Completion Date
06-Jan-2020

Relations

Buy Standard

Standard
EN ISO 180:2001
English language
13 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN ISO 180:2001
01-junij-2001
1DGRPHãþD
SIST EN ISO 180:2000
Polimerni materiali - Ugotavljanje udarne žilavosti po Izodu (ISO 180:2000)
Plastics - Determination of Izod impact strength (ISO 180:2000)
Kunststoffe - Bestimmung der Izod-Schlagzähigkeit (ISO 180:2000)
Plastiques - Détermination de la résistance au choc Izod (ISO 180:2000)
Ta slovenski standard je istoveten z: EN ISO 180:2000
ICS:
83.080.01 Polimerni materiali na Plastics in general
splošno
SIST EN ISO 180:2001 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN ISO 180:2001

---------------------- Page: 2 ----------------------

SIST EN ISO 180:2001
EUROPEAN STANDARD
EN ISO 180
NORME EUROPÉENNE
EUROPÄISCHE NORM
December 2000
ICS 83.080.01 Supersedes EN ISO 180:1996
English version
Plastics - Determination of Izod impact strength (ISO 180:2000)
Plastiques - Détermination de la résistance au choc Izod Kunststoffe - Bestimmung der Izod-Schlagzähigkeit (ISO
(ISO 180:2000) 180:2000)
This European Standard was approved by CEN on 3 December 2000.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the Management Centre has the same status as the official
versions.
CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece,
Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: rue de Stassart, 36  B-1050 Brussels
© 2000 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN ISO 180:2000 E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------

SIST EN ISO 180:2001
Page 2
EN ISO 180:2000
Foreword
The text of the International Standard ISO 180:2000 has been prepared by Technical Committee
ISO/TC 61 "Plastics" in collaboration with Technical Committee CEN/TC 249 "Plastics" the
secretariat of which is held by IBN.
This European Standard supersedes EN ISO 180:1996
This European Standard shall be given the status of a national standard, either by publication of an
identical text or by endorsement, at the latest by June 2001, and conflicting national standards shall
be withdrawn at the latest by June 2001.
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the
following countries are bound to implement this European Standard: Austria, Belgium, Czech
Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg,
Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and the United Kingdom.
Endorsement notice
The text of the International Standard ISO 180:2000 was approved by CEN as a European Standard
without any modification.
NOTE: Normative references to International Standards are listed in annex ZA (normative).

---------------------- Page: 4 ----------------------

SIST EN ISO 180:2001
Page 3
EN ISO 180:2000
Annex ZA (normative)
Normative references to international publications
with their relevant European publications
This European Standard incorporates by dated or undated reference, provisions from other
publications. These normative references are cited at the appropriate places in the text and the
publications are listed hereafter. For dated references, subsequent amendments to or revisions of any
of these publications apply to this European Standard only when incorporated in it by amendment or
revision. For undated references the latest edition of the publication referred to applies (including
amendments).
NOTE Where an International Publication has been modified by common modifications, indicated by (mod.), the
relevant EN/HD applies.
Publication Year Title EN/HD Year
ISO 291 1997 Plastics - Standard atmospheres for EN ISO 291 1997
conditioning and testing
ISO 294-1 1996 Plastics - Injection moulding of test EN ISO 294-1 1998
specimens of thermoplastic materials -
Part 1: General principles, and
moulding of multipurpose and bar test
specimens
ISO 295 1991 Plastics - Compression moulding of test EN ISO 295 1998
specimens of thermosetting materials
ISO 2818 1994 Plastics - Preparation of test specimens EN ISO 2818 1996
by machining
ISO 3167 1993 Plastics - Multipurpose-test specimens EN ISO 3167 1996

---------------------- Page: 5 ----------------------

SIST EN ISO 180:2001

---------------------- Page: 6 ----------------------

SIST EN ISO 180:2001
INTERNATIONAL ISO
STANDARD 180
Third edition
2000-12-15
Plastics — Determination of Izod impact
strength
Plastiques — Détermination de la résistance au choc Izod
Reference number
ISO 180:2000(E)
©
ISO 2000

---------------------- Page: 7 ----------------------

SIST EN ISO 180:2001
ISO 180:2000(E)
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but shall not
be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In downloading this
file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat accepts no liability in this
area.
Adobe is a trademark of Adobe Systems Incorporated.
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation parameters
were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In the unlikely event
that a problem relating to it is found, please inform the Central Secretariat at the address given below.
© ISO 2000
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic
or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISO's member body
in the country of the requester.
ISO copyright office
Case postale 56 � CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.ch
Web www.iso.ch
Printed in Switzerland
ii © ISO 2000 – All rights reserved

---------------------- Page: 8 ----------------------

SIST EN ISO 180:2001
ISO 180:2000(E)
Contents Page
Foreword.iv
1 Scope .1
2 Normative references .2
3 Terms and definitions .2
4 Principle.3
5 Apparatus .3
6 Test specimens.3
7 Procedure .7
8 Calculation and expression of results.7
9 Precision.8
10 Test report .8
© ISO 2000 – All rights reserved iii

---------------------- Page: 9 ----------------------

SIST EN ISO 180:2001
ISO 180:2000(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO
member bodies). The work of preparing International Standards is normally carried out through ISO technical
committees. Each member body interested in a subject for which a technical committee has been established has
the right to be represented on that committee. International organizations, governmental and non-governmental, in
liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical
Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 3.
Draft International Standards adopted by the technical committees are circulated to the member bodies for voting.
Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this International Standard may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights.
International Standard ISO 180 was prepared by Technical Committee ISO/TC 61, Plastics, Subcommittee SC 2,
Mechanical properties.
This third edition cancels and replaces the second edition (ISO 180:1993), which has been technically revised.
iv © ISO 2000 – All rights reserved

---------------------- Page: 10 ----------------------

SIST EN ISO 180:2001
INTERNATIONAL STANDARD ISO 180:2000(E)
Plastics — Determination of Izod impact strength
1 Scope
1.1 This International Standard specifies a method for determining the Izod impact strength of plastics under
defined conditions. A number of different types of specimen and test configurations are defined. Different test
parameters are specified according to the type of material, the type of test specimen and the type of notch.
1.2 The method is used to investigate the behaviour of specified types of specimen under the impact conditions
defined and for estimating the brittleness or toughness of specimens within the limitations inherent in the test
conditions.
1.3 The method is suitable for use with the following range of materials:
� rigid thermoplastic moulding and extrusion materials, including filled and reinforced compounds in addition to
unfilled types; rigid thermoplastics sheets;
� rigid thermosetting moulding materials, including filled and reinforced compounds; rigid thermosetting sheets,
including laminates;
� fibre-reinforced thermosetting and thermoplastic composites incorporating unidirectional or non-unidirectional
reinforcements such as mat, woven fabrics, woven rovings, chopped strands, combination and hybrid
reinforcements, rovings and milled fibres and sheet made from pre-impregnated materials (prepregs);
� thermotropic liquid-crystal polymers.
1.4 The method is not normally suitable for use with rigid cellular materials and sandwich structures containing
cellular material. Also, notched specimens are not normally used for long-fibre-reinforced composites or
thermotropic liquid-crystal polymers.
1.5 The method is suited to the use of specimens which may be either moulded to the chosen dimensions,
machined from the central portion of a standard multipurpose test specimen (see ISO 3167) or machined from
finished or semifinished products such as mouldings, laminates and extruded or cast sheet.
1.6 The method specifies preferred dimensions for the test specimen. Tests which are carried out on specimens
of different dimensions or with different notches, or specimens which are prepared under different conditions, may
produce results which are not comparable. Other factors, such as the energy capacity of the apparatus, its impact
velocity and the conditioning of the specimens can also influence the results. Consequently, when comparative
data are required, these factors must be carefully controlled and recorded.
1.7 The method should not be used as a source of data for design calculations. Information on the typical
behaviour of a material can be obtained, however, by testing at different temperatures, by varying the notch radius
and/or the thickness and by testing specimens prepared under different conditions.
© ISO 2000 – All rights reserved 1

---------------------- Page: 11 ----------------------

SIST EN ISO 180:2001
ISO 180:2000(E)
2 Normative references
The following normative documents contain provisions which, through reference in this text, constitute provisions of
this International Standard. For dated references, subsequent amendments to, or revisions of, any of these
publications do not apply. However, parties to agreements based on this International Standard are encouraged to
investigate the possibility of applying the most recent editions of the normative documents indicated below. For
undated references, the latest edition of the normative document referred to applies. Members of ISO and IEC
maintain registers of currently valid International Standards.
ISO 291:1997, Plastics� Standard atmospheres for conditioning and testing.
ISO 293:1986, Plastics� Compression moulding test specimens of thermoplastic materials.
ISO 294-1:1996, Plastics� Injection moulding of test specimens of thermoplastic materials� Part 1: General
principles, and moulding of multipurpose and bar test specimens.
ISO 295:1991, Plastics� Compression moulding of test specimens of thermosetting materials.
1)
ISO 1268:1974 , Plastics� Preparation of glass fibre reinforced, resin bonded, low pressure laminated plates or
panels for test purposes.
ISO 2602:1980, Statistical interpretation of test results� Estimation of the mean� Confidence interval.
ISO 2818:1994, Plastics� Preparation of test specimens by machining.
2)
ISO 3167:— , Plastics� Multipurpose test specimens.
ISO 10724-1:1998, Plastics� Injection moulding of test specimens of thermosetting powder moulding compounds
(PMCs)� Part 1: General principles and moulding of multipurpose test specimens.
ISO 13802:1999, Plastics� Verification of pendulum impact-testing machines� Charpy, Izod and tensile impact-
testing.
3 Terms and definitions
For the purposes of this International Standard, the following terms and definitions apply.
3.1
Izod un
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.