Aerospace series - Connectors, electrical, circular, scoop-proof, triple start threaded coupling, operating temperature 175 °C or 200 °C continuous - Part 001: Technical specification

This document specifies the general characteristics, the conditions for qualification, acceptance and quality assurance, as well as the test programs and groups for threaded ring coupling circular connectors, fire resistant, intended for use in a temperature range from − 65 °C to 175 °C continuous or 200 °C continuous according to the classes.

Luft- und Raumfahrt - Elektrische Rundsteckverbinder, kontaktgeschützt, dreigängige Gewinde-Schnellkupplung, Betriebstemperatur 175 °C oder 200 °C konstant - Teil 001: Technische Lieferbedingungen

Dieses Dokument legt die allgemeinen Eigenschaften, die Bedingungen für Qualifikation, Annahme und Qualitätssicherung sowie Prüfprogramme und -gruppen für Rundsteckverbinder mit Gewinde-Schnell-kupplung, feuerbeständig, bestimmt für die Anwendung in einem Temperaturbereich von −65 °C bis 175 °C konstant oder 200 °C konstant, entsprechend den Klassen, fest.

Série aérospatiale - Connecteurs électriques circulaires, à contacts protégés, à accouplement par filetage, à pas rapide à trois filets, température d'utilisation 175 °C ou 200 °C continu - Partie 001 : Spécification technique

La présente Norme spécifie les caractéristiques générales, les conditions de qualification, d’acceptation et d’assurance qualité, ainsi que les programmes et les groupes d’essais des connecteurs circulaires à accouplement par bague filetée, résistants au feu, utilisables dans une plage de températures comprises entre  65 °C et 175 °C continu, ou 200 °C continu suivant les classes.

Aeronavtika - Konektorji, električni, okrogli, zaščiten kontakt, hitra spojka z navojem, stalna delovna temperatura 175 °C ali 200 °C - 001. del: Tehnična specifikacija

Ta dokument določa splošne značilnosti, pogoje kvalifikacije, sprejemljivosti in zagotavljanja kakovosti ter preskusne programe in skupine za okrogle konektorje, priključene z navojnim obročkom, ognjevzdržne, za uporabo pri stalnih temperaturah med –65 °C in 175 °C ali pri stalni temperaturi 200 °C, odvisno od razreda.

General Information

Status
Withdrawn
Publication Date
11-Sep-2019
Withdrawal Date
19-Sep-2022
Technical Committee
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
16-Sep-2022
Due Date
09-Oct-2022
Completion Date
20-Sep-2022

Relations

Buy Standard

Standard
EN 3645-001:2019
English language
104 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 3645-001:2019
01-november-2019
Nadomešča:
SIST EN 3645-001:2015
Aeronavtika - Konektorji, električni, okrogli, zaščiten kontakt, hitra spojka z
navojem, stalna delovna temperatura 175 °C ali 200 °C - 001. del: Tehnična
specifikacija
Aerospace series - Connectors, electrical, circular, scoop-proof, triple start threaded
coupling, operating temperature 175 °C or 200 °C continuous - Part 001: Technical
specification
Luft- und Raumfahrt - Elektrische Rundsteckverbinder, kontaktgeschützt, dreigängige
Gewinde-Schnellkupplung, Betriebstemperatur 175 °C oder 200 °C konstant - Teil 001:
Technische Lieferbedingungen
Série aérospatiale - Connecteurs électriques circulaires, à contacts protégés, à
accouplement par filetage, à pas rapide à trois filets, température d'utilisation 175 °C ou
200 °C continu - Partie 001 : Spécification technique
Ta slovenski standard je istoveten z: EN 3645-001:2019
ICS:
31.220.10 Vtiči in vtičnice, konektorji Plug-and-socket devices.
Connectors
49.060 Letalska in vesoljska Aerospace electric
električna oprema in sistemi equipment and systems
SIST EN 3645-001:2019 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
SIST EN 3645-001:2019

---------------------- Page: 2 ----------------------
SIST EN 3645-001:2019


EN 3645-001
EUROPEAN STANDARD

NORME EUROPÉENNE

August 2019
EUROPÄISCHE NORM
ICS 49.060 Supersedes EN 3645-001:2015
English Version

Aerospace series - Connectors, electrical, circular, scoop-
proof, triple start threaded coupling, operating
temperature 175 °C or 200 °C continuous - Part 001:
Technical specification
Série aérospatiale - Connecteurs électriques Luft- und Raumfahrt - Elektrische Rundsteckverbinder,
circulaires, à contacts protégés, à accouplement par kontaktgeschützt, dreigängige Gewinde-
filetage, à pas rapide à trois filets, température Schnellkupplung, Betriebstemperatur 175 °C oder 200
d'utilisation 175 °C ou 200 °C continu - Partie 001 : °C konstant - Teil 001: Technische Lieferbedingungen
Spécification technique
This European Standard was approved by CEN on 29 April 2019.

CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.

This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
United Kingdom.





EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2019 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 3645-001:2019 E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------
SIST EN 3645-001:2019
EN 3645-001:2019 (E)
Contents Page
European foreword . 3
Introduction . 4
1 Scope . 5
2 Normative references . 5
3 Terms and definitions . 6
4 Description . 6
5 Design . 8
6 Definition drawings and masses . 9
7 Tests . 66
8 Quality assurance . 85
9 Designation and marking .103
10 Delivery conditions .104
11 Packaging .104
12 Storage .104

2

---------------------- Page: 4 ----------------------
SIST EN 3645-001:2019
EN 3645-001:2019 (E)
European foreword
This document (EN 3645-001:2019) has been prepared by the Aerospace and Defence Industries
Association of Europe - Standardization (ASD-STAN).
After enquiries and votes carried out in accordance with the rules of this Association, this Standard has
received the approval of the National Associations and the Official Services of the member countries of ASD,
prior to its presentation to CEN.
This European Standard shall be given the status of a national standard, either by publication of an identical
text or by endorsement, at the latest by February 2020, and conflicting national standards shall be
withdrawn at the latest by February 2020.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN shall not be held responsible for identifying any or all such patent rights.
This document supersedes EN 3645-001:2015.
According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus,
Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Republic of North
Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United
Kingdom.

3

---------------------- Page: 5 ----------------------
SIST EN 3645-001:2019
EN 3645-001:2019 (E)
Introduction
This family of connectors is derived from MIL-DTL-38999 series III, with which it is intermateable and
interchangeable. It is particularly suitable for use in zones of severe environmental conditions on board
aircraft, applying EN 2282.
These connectors are distinguishable from MIL-DTL-38999 by:
 a compatibility with size 8 power and quadrax contacts;
 self-extinguishing materials;
 compatibility with reduced diameter cables;
 additional reinforced fuel resistant insert type;
 additional insert with grounded cavities.

4

---------------------- Page: 6 ----------------------
SIST EN 3645-001:2019
EN 3645-001:2019 (E)
1 Scope
This document specifies the general characteristics, the conditions for qualification, acceptance and quality
assurance, as well as the test programs and groups for threaded ring coupling circular connectors,
fire-resistant, intended for use in a temperature range from − 65 °C to 175 °C continuous or 200 °C
continuous according to the classes.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
EN 2267-002, Aerospace series — Cables, electrical, for general purpose — Operating temperatures between
− 55 °C and 260 °C — Part 002: General
EN 2282, Aerospace series — Characteristics of aircraft electrical supplies
EN 2346, Aerospace series — Fire resistant electrical cables — Dimensions, conductor resistance and mass
EN 2591-100 (all parts), Aerospace series — Elements of electrical and optical connection — Test methods —
Part 100: General
EN 3197, Aerospace series — Design and installation of aircraft electrical and optical interconnection
systems
EN 3645-002, Aerospace series — Connectors, electrical, circular, scoop-proof, triple start threaded coupling,
operating temperature 175 °C or 200 °C continuous — Part 002: Specification of performance and contact
arrangements
EN 3909, Aerospace series — Test fluids and test methods for electrical and optical components and sub-
assemblies
EN 9133, Aerospace series — Quality management systems — Qualification procedure for aerospace
standard parts
ISO 68-1, ISO general purpose screw threads — Basic profile — Part 1: Metric screw threads
ISO 261, ISO general-purpose metric screw threads — General plan
ISO 262, ISO general-purpose metric screw threads — Selected sizes for screws, bolts and nuts
ISO 965-2, ISO general purpose metric screw threads — Tolerances — Part 2: Limit of sizes for general
purpose external and internal screw threads — Medium quality
ISO 4524-1, Metallic coatings — Test methods for electrodeposited gold and gold alloy coatings —
Part 1: Determination of coating thickness
MIL-DTL-38999K, Connectors, electrical, circular, miniature, high density, quick disconnect (bayonet,
threaded, and breech coupling), environment resistant, removable crimp and hermetic solder contacts,
1)
general specification for

1) Published by: DoD National (US) Mil. Department of Defense http://www.defenselink.mil/.
5

---------------------- Page: 7 ----------------------
SIST EN 3645-001:2019
EN 3645-001:2019 (E)
MIL-DTL-38999/62, Sealing boot, size 8, pin or socket, shielded crimp contacts, electrical connector, circular,
1)
metric
1)
MIL-HDBK-454, General guidelines for electronic equipment
1)
MIL-STD-1373, Screw-thread, modified, 60°, stub, double
1)

MIL-STD-1560B, Department of Defense interface standard: insert arrangements for
3 Terms and definitions
For the purposes of this document, the terms and definitions given in EN 2591-100 apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
• IEC Electropedia: available at http://www.electropedia.org/
• ISO Online browsing platform: available at http://www.iso.org/obp
4 Description
4.1 General
Different variants of materials, housings and contact arrangements are provided according to the classes
depending on the service conditions.
The pair of connectors is characterized:
 by shell to shell bottoming;
 by its triple threaded and self-locking coupling system;
 by plugs with shielding ring providing protection against radioelectrical interference;
 by the scoop-proof shells.
These connectors use the following contacts:
 crimped sizes 22, 20, 16, 12, 10 and 8;
 soldered (model Y) sizes 22, 20, 16 and 12;
 coaxial crimped or soldered sizes 16, 12 and 8;
For arrangements comprising the letter G or
Q, all contacts are grounded to the receptacle
 triaxial crimped or soldered size 8;
housing
 quadrax crimped size 8.
The receptacles and plugs contain either male contacts or female contacts.
The contacts fitted in the class Y receptacles are exclusively of the male solder type.
The connectors are polarized by means of keyways and keys; polarization shall be obtained before the male
contacts enter the insert of the female contacts and before the coupling ring is engaged. The position of the
keying arrangement is given in Table 5.
The visual check of coupling is obtained by masking of a red colour band on the receptacle.
6

---------------------- Page: 8 ----------------------
SIST EN 3645-001:2019
EN 3645-001:2019 (E)
4.2 Receptacle
The receptacle housing may be attached:
 square flange;
 nut, with sealing by O-ring at the attachment;
round soldered or brazed flange for class Y connectors.
4.3 Plug
The coupling ring is permanently fitted to the plug and allows coupling and uncoupling of the connectors.
The lanyard release version may also be uncoupled by pulling on the lanyard.
The plug is fitted with a self-locking mechanism and a grounding spring device ensuring electrical
continuity between the coupled connector housings.
An anti-decoupling device shall be provided to maintain complete coupling.
4.4 Materials and surface treatment
4.4.1 General
When dissimilar metals are in close contact, adequate protection against corrosion shall be used for the
electromotive force of the cell not to exceed 0,25 V (see EN 3197).
4.4.2 Housing
The material of the housings for the connectors and fittings may be either aluminium alloy, passivated
stainless steel or composite. Aluminium alloy and composite shall be plated as defined by the class
(composite coupling rings and Hex nut may be unplated) (see EN 3645-002).
4.4.3 Contacts
Unless otherwise specified, the non-removable contacts shall be in ferrous alloy for class Y and in copper
alloy for the other classes.
They shall be gold-plated on an appropriate undercoat. Selective protection is authorized provided that it
is sufficient to ensure that the specified performance is achieved.
Measurement of the thickness of the protective plating shall be effected in accordance with ISO 4524-1.
For removable contacts, see EN 3645-002.
4.4.4 Non-metallic materials
The materials used for insert, seals and grommets shall have a hardness and mechanical and electrical
characteristics consistent with the required use.

7

---------------------- Page: 9 ----------------------
SIST EN 3645-001:2019
EN 3645-001:2019 (E)
5 Design
5.1 Housings
The connector housings shall be one-piece. They shall contain teeth at the rear over their entire periphery
and shall accommodate the rear accessories. The receptacle shall be fitted with a seal for sealing the
coupled housings.
Jam-nut receptacles shall contain an O-ring seal. The nut shall have holes for the passage of locking wire.
During coupling the grounding spring shall be engaged a minimum of 1,02 mm in the receptacle before the
contacts engage.
Except for the triple start threads, which shall conform to standard MIL-STD-1373, threads shall conform
to standards ISO 68-1, ISO 261, ISO 262 and ISO 965-2.
The coupling ring shall be designed so that the male and female contacts engage when it is turned in a
clockwise direction and disengage when turned anticlockwise. The coupling threads may have a lubricant
applied during manufacture.
Full locking of the connectors shall occur at about 360°. On completion of tightening of the coupling ring,
mechanical contact shall exist between the receptacle and plug housings. A red band shall be located on
the receptacle so as to be visible when unmated and fully covered when completely mated.
The receptacle has five keyways which engage with corresponding keys on the plug. The major key is fixed
and is wider than the others. Polarization is ensured by the different positions which the minor keys may
take. The position of the insert is fixed relative to the major key.
A blue-coloured band indicating that the crimped contacts of the connectors are rear-releasable shall be
provided:
 in front of the flange on square flange receptacles;
 on the flange of jam-nut receptacles;
 on the coupling ring of plugs.
This band shall be positioned so that at least one is visible when the connectors are fitted and when they
are mated or unmated. Hermetic receptacles do not require blue colour band.
5.2 Inserts
The insert for contacts shall be non-removable; it shall be mechanically held in the housing. Sealing shall
be provided between the housing and insert.
The front face of the insert shall be such that sealing is ensured when the connectors are coupled. The
interfacial seal of the insert of the male contacts shall be bonded on the hard insert.
The grommet shall permit sealing for all cable diameters indicated in EN 3645-002 and shall not be
removable.
8

---------------------- Page: 10 ----------------------
SIST EN 3645-001:2019
EN 3645-001:2019 (E)
The mechanical contacts retention system shall be integrated in the hard insert.
The design of non-hermetic connectors shall permit individual installation of the contacts without removal
of the insert or grommet. Fitting and removal of the contacts shall be from the rear with the tools specified
in the contact product standards.
Contact position identification shall be permanent and contrasted on the front face of the insert or the
interfacial seal and on the rear face of the grommet as indicated in 6.6.
The marking shall not be recessed or raised on the surfaces providing a seal.
6 Definition drawings and masses
6.1 General
The general dimensions and the masses of receptacles, plugs and protective covers are given in the product
standards.
6.2 Receptacle mating dimensions
The mating dimensions of receptacles are shown in Figure 1 and details V and W as well as in Tables 1, 2
and 3.
Dimensions and tolerances are in millimetres.
9

---------------------- Page: 11 ----------------------
SIST EN 3645-001:2019
EN 3645-001:2019 (E)



a The distance between the front face of the shell and the point where the right end of a gauge with a diameter
equal to the nominal diameter of a male contact comes into contact with the elastic part of the female contact.
Figure 1 — Receptacle – Coupling dimensions

10

---------------------- Page: 12 ----------------------
SIST EN 3645-001:2019
EN 3645-001:2019 (E)
Table 1 — Receptacle – Dimensions (1 of 2)
A dia. B dia. C dia. D dia. D dia. E dia. E dia. F dia.
Housing
size (except classes (classes J and (except classes (classes J and
J and M) M only) J and M) M only)
+ 0,13
max.   max.
− 0,25
14,42 11,36 11,43 12,63 12,70
09 14,55 7,24 15,88
14,14 11,20 11,20 12,34 12,34
17,60 14,61 14,68 15,88 15,95
11 17,73 10,49 19,05
17,32 14,45 14,45 15,60 15,60
20,77 17,45 17,52 19,66 19,73
13 20,90 13,39 22,23
20,49 17,30 17,30 19,38 19,38
23,95 20,63 20,70 22,84 22,91
15 24,08 16,56 25,40
23,67 20,44 20,44 22,56 22,56
28,30 23,80 23,87 26,01 26,08
17 28,52 19,74 30,16
27,97 23,64 23,64 25,73 25,73
29,89 26,47 26,54 28,63 28,70
19 30,12 22,00 31,75
29,56 26,31 26,31 28,40 28,40
33,07 29,64 29,71 31,85 31,92
21 33,30 25,17 34,73
32,74 29,49 29,49 31,57 31,57
36,24 32,82 32,89 35,03 35,10
23 36,47 28,35 38,10
35,91 32,66 32,66 34,75 34,75
39,42 35,99 35,06 38,20 38,27
25 39,65 31,52 41,28
39,09 35,84 35,84 37,92 37,92

Table 1 — Receptacle – Dimensions (2 of 2)
Contact M dia. N dia. P dia. R dia. S dia.
size
max.
1,35 1,88 0,97 1,70
22 0,71
1,27 1,75 0,89 1,60
1,91 2,44 1,32 2,26
20 0,97
1,83 2,31 1,24 2,16
2,49 3,02 1,88 2,84
16 1,52
2,41 2,90 1,80 2,74
3,30 3,84 2,69 3,66
12 2,34
3,23 3,71 2,62 3,56
4,09 4,62 3,48 4,45
10 3,12
4,01 4,50 3,40 4,34
6,50 7,06 5,84 6,81
8 5,49
6,38 6,93 5,77 6,71

11

---------------------- Page: 13 ----------------------
SIST EN 3645-001:2019
EN 3645-001:2019 (E)
Table 2 — Receptacle – Thread
BB - Thread
a
External threading
Designation
Class 2A
Class 2A thread
See
Housing
Thread Apparent Actual External Diameter Diameter
b
size Note
size pitch pitch diameter on side at thread end
inch inch inch max. min. max. min. max. min.
09 0,625 0 15,83 15,63 15,17 14,97 14,41 14,05
11 0,750 0 19,01 18,80 18,35 18,14 17,58 17,23
13 0,875 0 22,18 21,98 21,52 21,32 20,76 20,41
0,038 1
15 1,000 0 25,36 25,15 24,70 24,49 23,94 23,58
17 1,187 5 30,11 29,80 29,24 28,99 28,28 27,82
0,100 0,300
19 1,250 0 31,69 31,39 30,83 30,58 29,87 29,41
21 1,375 0 34,87 34,56 34,01 33,75 33,05 32,59
0,050 8
23 1,500 0 38,04 37,74 37,18 36,93 36,22 35,76
25 1,625 0 41,22 40,91 40,36 40,10 39,40 38,94
a
According to MIL-STD-1373.
b
Gauges for protected threads: it is permissible to increase the maximum limit for gauge diameters by the value specified in this
column.
6.3 Plug mating dimensions
The mating dimensions of plugs are shown in Figure 2 and detail X in details V and W of Figure 1 and in
Tables 3 and 4.
Dimensions and tolerances are in millimetres.
12

---------------------- Page: 14 ----------------------
SIST EN 3645-001:2019
EN 3645-001:2019 (E)


Key
1 Spring finger
a The distance between the shell shoulder and the point where the right end of a gauge with a diameter equal to
the nominal diameter of a male contact comes into contact with the elastic part of the female contact.
b V and W: see Figure 1.
c Metallic
d Composite
e Over strap
Figure 2 — Plug – Coupling dimensions
13

---------------------- Page: 15 ----------------------
SIST EN 3645-001:2019
EN 3645-001:2019 (E)
Table 3 — Plug – Dimensions
Housing BB dia. C dia. G dia H dia. H dia. J dia. K dia. K dia. K dia. L dia.
1 1 1
size
min. between
between
front of keys
keys
+ 0,13 + 0,25 (classes J
keys
metallic composite over keys
(except
− 0,25 − 0,03 metallic and M
classes J
only)
and
and M)
composite
min.  min./max. min.   min.
9.96 12,27 11,13 11,13
09 11,48 7,24 16,51 8,51 10,59 7,92
9,55 11,99 10,97 10,85
13,19 15,52 14,38 14,38
11 14,73 10,49 19,69 11,74 13,84 10,92
12,61 15,24 14,22 14,10
16,08 19,31 17,22 17,22
13 17,58 13,39 22,86 14,63 16,68 13,81
15,45 19,02 17,07 16,95
19,26 22,48 20,40 20,40
15 20,75 16,56 26,04 17,81 19,86 16,99
18,63 22,20 20,24 20,12
22,43 25,66 23,57 23,57
17 23,92 19,74 30,89 20,98 23,03 20,16
21,80 25,37 23,42 23,30
24,82 28,32 26,24 26,24
19 26,59 22,00 32,49 23,57 25,70 22,42
24,47 28,04 26,09 25,97
27,99 31,50 29,42 29,42
21 29,77 25,17 35,66 26,74 28,87 25,60
27,64 31,22 29,26 29,14
31,17 34,67 32,59 32,59
23 32,94 28,35 38,84 29,92 32,05 28,77
30,82 34,39 32,44 32,32
34,34 37,85 35,77 35,77
25 36,12 31,52 42,01 33,09 35,22 31,92
33,99 37,57 35,61 35,49
NOTE Diameter “K1” (dia. between keys) is for metallic and composite plugs, diameter “K (K min. – dia. front of
keys)” is for metallic and composite plugs, diameter “H” is for metallic plugs, and diameter “H (H min.)” is for
1 1
composite plugs.

14

---------------------- Page: 16 ----------------------
SIST EN 3645-001:2019
EN 3645-001:2019 (E)
Table 4 — Plug – Thread
DD dia. - Thread
a

Designation Internal thread
Class 2B thread Class 2B
Housing
Thread Apparent Actual Internal Diameter Diameter at
size
size pitch pitch diameter on side thread end
inch  max. min. max. min. max. min.
09 0,625 0 14,96 14,71 15,46 15,21 16,38 15,97
11 0,750 0 18,14 17,88 18,64 18,38 19,55 19,15
13 0,875 0 21,31 21,06 21,81 21,56 22,73 22,32
15 1,000 0 24,49 24,23 24,99 24,73 25,90 25,50
17 1,187 5 0,100 0,300 28,94 28,63 29,60 29,29 30,77 30,26
19 1,250 0 30,53 30,22 31,19 30,88 32,35 31,85
21 1,375 0 33,70 33,40 34,36 34,06 35,53 35,02
23 1,500 0 36,88 36,57 37,54 37,23 38,70 38,20
25 1,625 0 40,05 39,75 40,71 40,41 41,88 41,37
a

According to MIL-STD-1373.

6.4 Receptacle and plug polarization
See Figure 3 and Table 5.
Dimensions and tolerances are in millimetres.

Receptacle Plug
Figure 3 — Receptacle and plug polarization
15

---------------------- Page: 17 ----------------------
SIST EN 3645-001:2019
EN 3645-001:2019 (E)
Table 5 — Position of the keys and keyways for receptacle and plug
Values in degrees
Housing Polarization
size index
a b c d
N 105 140 215 265
A 102 132 248 320
B 80 118 230 312
09
C 35 140 205 275
D 64 155 234 304
E 91 131 197 240
N 95 141 208 236
A 113 156 182 292
11
B 90 145 195 252
13
C 53 156 220 255
15
D 119 146 176 298
E 51 141 184 242
N 80 142 196 293
17
A 135 170 200 310
19
B 49 169 200 244
21
C 66 140 200 257
23
D 62 145 180 280
25
E 79 153 197 272

6.5 Dimensions of the rear part of the connectors
6.5.1 Accessory interface dimensions
The dimensions of the rear part of receptacles and plugs with threads for mounting accessories are shown
in Figure 4 and Table 6.

16

---------------------- Page: 18 ----------------------
SIST EN 3645-001:2019
EN 3645-001:2019 (E)
Dimensions in millimetres



Optional design for Jam-nut receptacles
For metallic housing Classes J and M


For composite housing
Enlarged view of a tooth according to the projection of Y
the tooth on the maximum HH diameter (datum) Optional form
Key
1 Thread VV 5 Values for composite housing
2 Surface of sealing Ra 1,6 µm 6 Insulator
3 Sealing compound 7 7,11 min. clearance to minor thread diameter
4 Values for metallic housing 8 6,15 min. full thread.
Figure 4 — Dimensions of the rear part of the connectors
17

---------------------- Page: 19 ----------------------
SIST EN 3645-001:2019
EN 3645-001:2019 (E)
Table 6 — Dimensions of the rear part of the connectors
A dia. HH dia. NN PP dia. VV
Number of teeth Thread class
Housing
size
0
max. max. 6 g
− 0,15
09 7,59 10,57 12 8,80 M12 × 1
11 10,85 13,56 16 12,07 M15 × 1
13 13,74 16,58 20 14,96 M18 × 1
15 16,92 20,57 24 18,14
M22 × 1
17 20,09 23,57 28 21,31 M25 × 1
19 22,78 26,57 32 24,00 M28 × 1
21 25,96 29,57 36 27,18 M31 × 1
23 29,13 32,56 40 30,35
M34 × 1
25 32,31 35,56 44 33,53 M37 × 1

The axis of a tooth shall be in the medial plane of the main key or keyway.
Alignment tolerance of axis ± 1°.
6.5.2 Size 8 cavity - rear dimensions

Key
1 Rear face of the insulator
Applicable to contact arrangements 25N20
Figure 5 — Shrink boot style
18

---------------------- Page: 20 ----------------------
SIST EN 3645-001:2019
EN 3645-001:2019 (E)

Key
1 Rear face of the insulator
Applicable to contact arrangements 11-01; 17-02; 17-22;
17-75; 19-12; 19-17; 19-31; 21-20; 21-48; 21-75; 23-05;
23-06; 25-07; 25-08; 25-17; 25(Q/L)20; 25-46
Figure 6 — Piggyback boot style
See MIL-DTL-38999/62 for the sealing boot which has to be used.
6.6 Contact arrangements
The contact arrangements in the inserts are specified by Figures 8 to 76, which show the front face of male
inserts.
The following tolerances are applicable to the inserts fitted in the housing:
 centre of the entry diameter of each female insert (diameter R, Figure 1):

 centre of the end of each male contact:

D and G are given in Figure 3.
Arrangements comprising coaxial, triaxial or quadrax contacts grounded to the shell (identified by the
letter G or Q) are not applicable to plugs.
Arrangement comprising Quadrax contacts are identified by letter Q when these contacts are grounded to
the shell, and by letter L when not grounded.
19

---------------------- Page: 21 ----------------------
SIST EN 3645-001:2019
EN 3645-001:2019 (E)
Arrangement comprising reinforced inserts for power contacts are identified by letter R.
Arrangement comprising reinforced inserts for fuel ingress are identified by letter K.
Cavity size 8 for QUADRAX contacts
For all cavities receiving QUADRAX contact, the insert cavity keyway shall be oriented and aligned like the
main key of the connector. See Figure 7.
Tolerances are as follow:

Key
1 Connector main key axis
2 Insert cavity
Figure 7 — QUADRAX contacts

20

---------------------- Page: 22 ----------------------
SIST EN 3645-001:2019
EN 3645-001:2019 (E)
09G01 and 09Q01 09N35 09N98
Rating N/A Rating M Rating I
1 triaxial contact, size 8 6 contacts, size 22 3 contacts, size 20
1 QUADRAX contact, size 8


 X Y  X Y
Contact Contact
mm mm mm mm
 1 + 1,14 + 1,98  A + 1,65 + 0,97
 2  B 0
+ 1,98 − 1,14 − 1,91
 3 0  C
− 2,29 − 1,65 + 0,97
 4
− 1,98 − 1,14
NOTE No insert provided with the
5
− 1,14 + 1,98
arrangement.

6 0 0
Figure 8 Figure 9 Figure 10

21

---------------------- Page: 23 ----------------------
SIST EN 3645-001:2019
EN 3645-001:2019 (E)
11N01 11N02 and 11G02 11N05
Rating N Rating I Rating I
1 triaxial contact, size 8 2 contacts, size 16 5 contacts, size 20
11Q01 or 11L01
Rating N
1 QUADRAX contact, size 8


 X Y  X Y
Contact Contact
mm mm mm mm
 A 0  A
+ 2,41 + 1,65 + 1,42
 B 0  B
− 2,41 + 2,87 − 1,65
    C 0
− 3,30
    D − 2,87 − 1,65
    E − 1,65 + 1,42
Figure 11 Figure 12 Figure 13

22

---------------------- Page: 24 ----------------------
SIST EN 3645-001:2019
EN 3645-001:2019 (E)
11N12 11N35 11N98
Rating II Rating M Rating I
1 contact, size 12 13 contacts, size 22 6 contacts, size 20

 X Y  X Y
Contact Contact
mm mm mm mm

...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.