Information technology - Implementation of BCT applications using cabling in accordance with EN 50173-4

This Technical Report describes the following:
a)   the functional elements and structure of the cabling, external to homes, supporting community antenna television (CATV) and master antenna television/satellite master antenna television (MATV/SMATV) networks in accordance with EN 60728-1;
b)   the location and accommodation of the home network interface (HNI) in accordance with EN 60728-1;
c)   requirements for additional cabling performance requirements (i.e. insertion loss slope between 47 MHz and 862 MHz) and necessary amendments of the reference implementations of generic cabling within the home in accordance with EN 50173-4 in order to support the CATV, MATV/SMATV networks in accordance with EN 60728-1

Informationstechnik - Realisierung von RuK-Netzanwendungen mit Verkabelung nach EN 50173-4

Technologies de l'information - Mise en oeuvre des applications BCT utilisant un câblage réalisé selon la EN 50173-4

Informacijska tehnologija - Izvedba kabelskih aplikacij BCT v skladu z EN 50173-4

General Information

Status
Published
Publication Date
01-Apr-2020
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
31-Mar-2020
Due Date
05-Jun-2020
Completion Date
02-Apr-2020

Relations

Buy Standard

Technical report
TP CLC/TR 50173-99-2:2020
English language
34 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST-TP CLC/TR 50173-99-2:2020
01-maj-2020
Nadomešča:
SIST-TP CLC/TR 50173-99-2:2011
Informacijska tehnologija - Izvedba kabelskih aplikacij BCT v skladu z EN 50173-4
Information technology - Implementation of BCT applications using cabling in
accordance with EN 50173-4
Informationstechnik - Realisierung von RuK-Netzanwendungen mit Verkabelung nach
EN 50173-4
Technologies de l'information - Mise en oeuvre des applications BCT utilisant un câblage
réalisé selon la EN 50173-4
Ta slovenski standard je istoveten z: CLC/TR 50173-99-2:2020
ICS:
33.040.50 Vodi, zveze in tokokrogi Lines, connections and
circuits
35.110 Omreževanje Networking
SIST-TP CLC/TR 50173-99-2:2020 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
SIST-TP CLC/TR 50173-99-2:2020

---------------------- Page: 2 ----------------------
SIST-TP CLC/TR 50173-99-2:2020


TECHNICAL REPORT CLC/TR 50173-99-2

RAPPORT TECHNIQUE

TECHNISCHER BERICHT
March 2020
ICS 35.110 Supersedes CLC/TR 50173-99-2:2010
English Version
Information technology - Implementation of BCT applications
using cabling in accordance with EN 50173-4
Technologies de l'information - Mise en oeuvre des Informationstechnik - Realisierung von RuK-
applications BCT utilisant un câblage réalisé selon la EN Netzanwendungen mit Verkabelung nach EN 50173-4
50173-4


This Technical Report was approved by CENELEC on 2020-02-10.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.



European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2020 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
 Ref. No. CLC/TR 50173-99-2:2020 E

---------------------- Page: 3 ----------------------
SIST-TP CLC/TR 50173-99-2:2020
CLC/TR 50173-99-2:2020
Contents Page
European foreword . 5
Introduction . 6
1 Scope . 7
2 Normative references . 7
3 Definitions and abbreviations . 8
3.1 Definitions .8
3.2 Abbreviations . 10
4 Cabling structure .10
4.1 General . 10
4.2 Functional elements of networks in accordance with EN 60728 . 10
4.3 Cabling subsystems of networks in accordance with EN 60728 . 11
4.3.1 General . 11
4.3.2 External cabling subsystems . 12
4.3.3 Building backbone subsystem . 12
4.3.4 Home cabling subsystem . 13
4.4 Accommodation of functional elements . 14
4.4.1 Headend and antenna systems . 14
4.4.2 Building network . 14
4.4.3 Pathways and pathway systems . 14
4.4.4 HNI . 14
4.5 Interfaces . 14
4.5.1 BCT applications in accordance with EN 60728-1 . 14
4.5.2 Generic cabling in accordance with EN 50173-4 . 14
4.6 Dimensioning and configuring . 16
4.6.1 Home network interface . 16
5 Slope requirements .16
5.1 Channels and links in accordance with EN 50173-4 . 16
5.1.1 General . 16
5.1.2 BCT-x-L cabling . 17
5.1.3 BCT-x-M cabling . 17
5.1.4 BCT-x-H cabling . 17
6 Reference implementations .18
6.1 Balanced cabling . 18
6.1.1 General . 18
6.1.2 Cord lengths at maximum permanent link lengths . 20
6.1.3 Permanent link and cord length matrices . 21
6.1.4 Receiver leads . 22
2

---------------------- Page: 4 ----------------------
SIST-TP CLC/TR 50173-99-2:2020
CLC/TR 50173-99-2:2020
6.2 Coaxial cabling . 22
6.2.1 General . 22
6.2.2 Cord lengths at maximum permanent link lengths . 23
6.2.3 Maximum coaxial cable lengths . 24
6.2.4 Receiver leads . 25
Annex A (informative) Example implementations of TV and radio broadcast applications .26
A.1 General .26
A.2 System components .27
A.2.1 Mutual isolation between receivers .27
A.2.2 Power splitter performance .27
A.2.3 Impedance matching .27
A.3 Passive or active coaxial home networks .27
A.4 Home network implementations .29
A.4.1 Home network with balanced type cables (Case A and Case B) .29
A.4.2 Types and locations of baluns .30
A.4.2.1 General .30
A.4.2.2 Baluns at the ENI and baluns at the equipment interface toward the PHD .31
A.4.2.3 Baluns near or in the BO .32
A.4.2.4 Baluns in the cord between BO and the terminal equipment .32
A.5 Amplifiers at the home distributor .33
Bibliography .34

Table 1 — Main functional elements of networks in accordance with EN 60728 series .11
Table 2 — Slope performance of balanced cabling in accordance with EN 50173-4 .17
Table 3 — Slope performance of coaxial cabling in accordance with EN 50173-4 .17
Table 4 — Balanced BCT-B-L permanent link lengths for a range of cord lengths .21
Table 5 — Balanced BCT-B-M permanent link lengths for a range of cord lengths .22
Table A.1 — Typical attenuation performance of splitters .27
Table A.2 — Example of home network implementation with coaxial cabling (passive) from HNI1 to
SO .28
Table A.3 — Example of home network implementation with coaxial cabling (active) from HNI2 to
SO .28
Table A.4 — Example of home network implementation with balanced pair cables (active) from
HNI3 to coaxial TI (Case A) .30
Table A.5 — Example of home network implementation with balanced pair cables (active) from
HNI3 to coaxial SO (Case B) .30

Figure 1 — Structure of generic cabling for BCT applications (CATV) .12
Figure 2 — Structure of generic cabling for BCT applications (MATV/SMATV) .12
Figure 3 — Examples of location of HNI for various home network types .13
3

---------------------- Page: 5 ----------------------
SIST-TP CLC/TR 50173-99-2:2020
CLC/TR 50173-99-2:2020
Figure 4 — Schematic of generic cabling for BCT applications according to EN 50173-4 .15
Figure 5 — Slope interfaces (direct connection of HNI to BO) .15
Figure 6 — Slope interfaces (HNI to BO via splitter/amplifier equipment) .16
Figure 7 — Multi-stage slope compensation in homes containing SHDs .18
Figure 8 — Home cabling configurations for BCT-B applications .19
Figure 9 — Home cabling configurations for BCT-C applications .23
Figure A.1 — Examples of home network implementation using coaxial or balanced cables .26
Figure A.2 — Balun at the ENI .31
Figure A.3 — Baluns in the PHD .31
Figure A.4 — Balun built into the system outlet .32
Figure A.5 — Balun in the cord between BO and the TE .33

4

---------------------- Page: 6 ----------------------
SIST-TP CLC/TR 50173-99-2:2020
CLC/TR 50173-99-2:2020
European foreword
This document (CLC/TR 50173-99-2:2020) was prepared by the Technical Committee CENELEC
TC 215, Electrotechnical aspects of telecommunication equipment.
This document supersedes CLC/TR 50173-99-2:2010.
The following major modification has been made compared to CLC/TR 50173-99-2:2010:
a) Annex A.4 revised;
b) Normative references updated.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights.
5

---------------------- Page: 7 ----------------------
SIST-TP CLC/TR 50173-99-2:2020
CLC/TR 50173-99-2:2020
Introduction
EN 50173-4 specifies generic cabling in homes, installed to support one or more of the following groups
of applications and based upon balanced and coaxial cabling as appropriate:
a) Information and Communication Technologies (ICT);
b) Broadcast and Communication Technologies (BCT).
EN 50173-4 also provides requirements for backbone cabling subsystems within premises containing
multiple homes by reference to:
1) EN 50173-1 for cabling to support ICT applications;
2) standards of the EN 50083 and EN 60728 series to support BCT applications.
EN 50083 and EN 60728 standards deal with cable networks including equipment and associated
methods of measurement for headend reception, processing and distribution of television signals, sound
signals and their associated data signals and for processing, interfacing and transmitting all kinds of
signals for interactive services using all applicable transmission media including community antenna
television (CATV) and master antenna television/satellite master antenna television (MATV/SMATV)
networks.
This document describes the following:
— the functional elements and structure of the cabling, external to homes, supporting community
antenna television (CATV) and master antenna television/satellite master antenna television
(MATV/SMATV) networks in accordance with EN 60728-1;
— the location and accommodation of the home network interface (HNI) in accordance with
EN 60728-1;
— requirements for additional cabling performance requirements (i.e. insertion loss slope between
47 MHz and 862 MHz) and necessary amendments of the reference implementations of generic
cabling within the home in accordance with EN 50173-4 in order to support the CATV, MATV/SMATV
networks in accordance with EN 60728-1.
6

---------------------- Page: 8 ----------------------
SIST-TP CLC/TR 50173-99-2:2020
CLC/TR 50173-99-2:2020
1 Scope
This document describes the following:
a) the functional elements and structure of the cabling, external to homes, supporting community
antenna television (CATV) and master antenna television/satellite master antenna television
(MATV/SMATV) networks in accordance with EN 60728-1;
b) the location and accommodation of the home network interface (HNI) in accordance with
EN 60728-1;
c) requirements for additional cabling performance requirements (i.e. insertion loss slope between
47 MHz and 862 MHz) and necessary amendments of the reference implementations of generic
cabling within the home in accordance with EN 50173-4 in order to support the CATV, MATV/SMATV
networks in accordance with EN 60728-1.
Safety (electrical safety and protection, optical power, fire, etc.) and electromagnetic compatibility (EMC)
requirements are outside the scope of this document and are covered by standards and regulations.
However, information given in this document could be of assistance in meeting these standards and
regulations.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
EN 50173-1:2018, Information technology – Generic cabling systems – Part 1: General requirements
EN 50173-4:2018, Information technology – Generic cabling systems – Part 4: Homes
EN 50174 (all parts), Information technology – Cabling installation
EN 60728-1:2014, Cable networks for television signals, sound signals and interactive services – Part 1:
System performance of forward paths
EN 60728-1-1:2014, Cable networks for television signals, sound signals and interactive services – Part
1-1: RF cabling for two way home networks (IEC 60728-1-1:2014)
EN 60728-11, Cable networks for television signals, sound signals and interactive services – Part 11:
1
Safety
———————
1
At the time of publication of this document, EN 60728-11:2017 + A11:2018 were applicable.
7

---------------------- Page: 9 ----------------------
SIST-TP CLC/TR 50173-99-2:2020
CLC/TR 50173-99-2:2020
3 Definitions and abbreviations
3.1 Definitions
For the purposes of this document the following definitions apply in addition to those of EN 50173-1 and
EN 50173-4.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
• IEC Electropedia: available at http://www.electropedia.org/
• ISO Online browsing platform: available at http://www.iso.org/obp
3.1.1
branch feeder
feeder used for connecting a distribution point to a building network interface (BNI) or home network
interface (HNI), as appropriate
3.1.2
building network
network for transmission of television signal, sound signals and interactive services inside a multi-dwelling
building (excluding the home networks within the dwellings)
3.1.3
building network interface
interface between external network and the building network within a multi-dwelling building for the
network for the transmission of television signal, sound signals and interactive services
Note 1 to entry: This point is also called “transfer point” or “external network interface”.
3.1.4
community antenna television
system which is designed to provide sound and television signals received by terrestrial, satellite
antennas or provided by locally generated sources to the outlets of a large group of buildings
3.1.5
headend
equipment which is connected between receiving antennas or other signal sources and the remainder of
the cable networks, to process the signals to be distributed
Note 1 to entry: The headend may, for example, comprise antenna amplifiers, frequency converters, combiners,
separators and generators.
3.1.6
home network
RF cable network inside a single dwelling (one-family house or one unit of a multi-dwelling building) in the
SOHO (Small Offices Home Offices) environments or in the rooms of hotels, hospitals, etc.; the preferred
topology of this network is a star
Note 1 to entry: This network carries television signals, sound signals and interactive services up to the coaxial RF
interface (input and/or output) of the terminal equipment. It may comprise active equipment, passive equipment,
cables and connectors
3.1.7
home network interface
interface for access to the network for transmission of television signal, sound signals and interactive
services inside a home (single dwelling)
8

---------------------- Page: 10 ----------------------
SIST-TP CLC/TR 50173-99-2:2020
CLC/TR 50173-99-2:2020
3.1.8
hub headend
headend that distributes the signals provided by a super trunk feeder to two or more trunk feeders
3.1.9
local headend
headend which is connected direct to the system trunk feeders or to a short-haul trunk feeder
replacement link
3.1.10
master antenna television system
system which is designed to provide sound and television signals received by terrestrial antennas to the
outlets of a building or a group of buildings
3.1.11
remote headend
headend from which signals are delivered to a local headend via a long-distance terrestrial link
3.1.12
satellite master antenna television system
system which is designed to provide sound and television signals received by satellite to the outlets of a
building or a group of buildings
3.1.13
slope
difference in gain or attenuation at 47 MHz and 862MHz between any two points in a system
Note 1 to entry: The slope sign is considered:
a) negative when the attenuation increases with frequency (cables) or the gain (amplifiers) decreases
with frequency;
b) positive when the gain (amplifiers) increases with frequency (compensating slope).
3.1.14
spur feeder
feeder to which splitters, subscriber taps, or looped system outlets are connected
3.1.15
subscriber feeder
feeder connecting a subscriber tap to a system outlet or, where the latter is not used, directly to the
subscriber equipment
Note 1 to entry: A subscriber feeder may include filters and balun transformers.
3.1.16
supertrunk feeder
connects only between headends or between a headend and the first distribution point
3.1.17
system outlet (SO)
synonymous with the broadcast outlet (BO) interface of EN 50173-4 (except where a balun is installed
between a balanced cabling BO to provide a coaxial interface to the receiver, in which case the SO is
defined at the coaxial interface of the balun)
3.1.18
trunk feeder
feeder used for the transmission of signals between a headend and a distribution point or between
distribution points
9

---------------------- Page: 11 ----------------------
SIST-TP CLC/TR 50173-99-2:2020
CLC/TR 50173-99-2:2020
3.2 Abbreviations
For the purposes of this document the following abbreviations apply in addition to those of EN 50173-1
and EN 50173-4.
B Balun
BN Building Network
BNI Building Network Interface
BO Broadcast Outlet
CATV Community Antenna Television
DP Distribution Points
HCL Home Cabling Link
HN Home Network
HNI Home Network Interface
MATV Master Antenna Television
SMATV Satellite Master Antenna Television
SO System Outlet
4 Cabling structure
4.1 General
This document describes implementations of generic cabling in homes in accordance with EN 50173-4
and their connection to external cabling in order to support the BCT applications of Annex F of
EN 50173-1 and in accordance with the EN 60728 series of standards.
The delivery of BCT applications to support CATV or MATV/SMATV networks in accordance with the
EN 60728 series of standards to the home, independent of the premises that accommodate the home, is
described in terms of:
a) the functional elements required;
b) the cabling subsystems used to provide connections between the functional elements;
c) the interface (HNI) at which the cabling in accordance with EN 50173-4 is connected;
d) any additional application-specific functional elements within the home.
4.2 Functional elements of networks in accordance with EN 60728
EN 60728-1 describes the functional elements to support BCT applications in the case of CATV or
MATV/SMATV cable networks and includes the main functional elements described in Table 1.
10

---------------------- Page: 12 ----------------------
SIST-TP CLC/TR 50173-99-2:2020
CLC/TR 50173-99-2:2020
Table 1 — Main functional elements of networks in accordance with EN 60728 series
CATV networks MATV/SMATV networks
Remote Headend Headend
Local headend
Hub headend
Distribution point (DP)
Building network interface (BNI) Building network interface (BNI)
Floor distributor Floor distributor
Home network interface (HNI) Home network interface (HNI)
System outlet (SO) System outlet (SO)
NOTE The BNI and floor distributor are only relevant in premises
containing multiple homes and within which there is a defined building
cabling subsystem, separate from that of the home
4.3 Cabling subsystems of networks in accordance with EN 60728
4.3.1 General
EN 60728-1 describes the interconnection of the functional elements as shown in schematic form in
Figure 1 for CATV cable networks and in Figure 2 for MATV/SMATV cable networks.
11

---------------------- Page: 13 ----------------------
SIST-TP CLC/TR 50173-99-2:2020
CLC/TR 50173-99-2:2020

Figure 1 — Structure of generic cabling for BCT applications (CATV)

Figure 2 — Structure of generic cabling for BCT applications (MATV/SMATV)
4.3.2 External cabling subsystems
For CATV cable networks, the signals received by remote and/or local headends are delivered through
super trunk feeder cables to hub headends. The signals are then subdivided and delivered to distribution
points (DPs) via trunk feeder cables. A branch feeder cable connects each home network interface (HNI)
or building network interface (BNI) (in the case of multi dwelling premises) to a DP.
For MATV/SMATV cable networks the signals received by the antenna system are fed to the headend. A
branch feeder cable connects each home network interface (HNI) or building network interface (BNI) (in
the case of multi dwelling premises) to the headend.
4.3.3 Building backbone subsystem
Where the premises served by the external cabling subsystems accommodate multiple homes, the BNI is
connected to the HNI either via:
a) a subscriber feeder cable;
b) a spur feeder cable to a floor distributor and then a subscriber feeder cable.
12

---------------------- Page: 14 ----------------------
SIST-TP CLC/TR 50173-99-2:2020
CLC/TR 50173-99-2:2020
4.3.4 Home cabling subsystem
The signals delivered at the HNI are fed to the terminal equipment connected to the system outlet (SO)
through the home network comprising cabling and optional splitter/amplifier equipment.
The home cabling subsystem has different configurations depending on the extension and on the
applications made available at the home premises (see Figure 3). Various types of home networking for
home premises are described in EN 60728-1-1.
This technical report describes the delivery of the signals from the HNI to the SO using cabling in
accordance with EN 50173-4.
NOTE The home cabling subsystem defined and described in EN 50173-4 forms part of the home cabling
subsystem as shown in Figure 1 and Figure 2.

Figure 3 — Examples of location of HNI for various home network types
13

---------------------- Page: 15 ----------------------
SIST-TP CLC/TR 50173-99-2:2020
CLC/TR 50173-99-2:2020
4.4 Accommodation of functional elements
4.4.1 Headend and antenna systems
The headend systems for CATV cable networks are typically located in equipment rooms that provide all
the facilities (space, power, environmental control etc.) for passive components, active devices and
connection to local and/or remote antenna systems.
The headend systems for MATV/SMATV cable networks may be located in a small room or a dedicated
space, where all the facilities (space, power, etc.) for passive components, active devices and connection
to the antenna system are provided. Examples of headend and requirements for headend equipment are
described in EN 60728-5.
The installation of equipment shall be in accordance with EN 60728-11.
4.4.2 Building network
Within multi dwelling premises, the BNI is typically located in equipment rooms that should provide all the
facilities (space, power, environmental control etc.) for passive components and active devices. Each
equipment room should have direct access to the relevant cabling subsystems.
Where the functional elements share the same space as the distributors of generic cabling systems in
accordance with the EN 50173 series of standards; the requirements for the accommodation of
distributors are specified in EN 50173-1.
Requirements for building entrance facilities are specified in the EN 50174 series of standards.
NOTE The location of BNI and building entrance facilities which are provided can be subject to national or local
regulations.
4.4.3 Pathways and pathway systems
See the EN 50174 series of standards.
4.4.4 HNI
The use of generic cabling in accordance with EN 50173-4 to support BCT applications in accordance
with the EN 60728 series of standards (CATV or MATV/SMATV networks) requires the HNI to be located
within the home distributor (HD).
The requirements for the HD are specified in EN 50173-4.
The requirements for the accommodation of the HD are specified in EN 50174-2.
Requirements for home entrance facilities are specified in the EN 50174-2.
NOTE The location of HNI and home entrance facilities which are provided can be subject to national or local
regulations.
4.5 Interfaces
4.5.1 BCT applications in accordance with EN 60728-1
EN 60728-1 defines signal requirements at the HNI and the SO (supporting information is provided in
Annex A).
4.5.2 Generic cabling in accordance with EN 50173-4
4.5.2.1 Channel and permanent links
Figure 4 shows the general implementation of generic cabling within a home in accordance with
EN 50173-4 to support BCT applications.
14

---------------------- Page: 16 ----------------------
SIST-TP CLC/TR 50173-99-2:2020
CLC/TR 50173-99-2:2020

Figure 4 — Schematic of generic cabling for BCT applications according to EN 50173-4
4.5.2.2 Slope
The slope of the cabling between the HNI and
...

Questions, Comments and Discussion