Leather - Physical and mechanical tests - Determination of heat resistance of patent leather

This European Standard specifies two methods for determining the heat resistance of patent leather. Method A makes use of a modified lastometer whilst Method B uses the 'Zwik' apparatus. Both methods are applicable to patent leathers for all end uses.

Leder - Physikalische und mechanische Prüfungen - Wärmebeständigkeit von Lackleder

Diese Europäische Norm legt zwei Verfahren zur Bestimmung der Wärmebeständigkeit von Lackleder fest. Verfahren A benutzt ein modifiziertes Lastometer, während beim Verfahren B das "Zwik" Gerät angewendet wird. Beide Verfahren sind für Lackleder für jede Endanwendung geeignet.

Cuir - Essais physiques et mécaniques - Détermination de la résistance a la chaleur des cuirs vernis

La présente Norme européenne spécifie deux méthodes visant a déterminer la résistance a la chaleur du cuir vernis. La méthode A met en ?uvre un dispositif de charge modifié et la méthode B utilise l'appareillage " Zwik ". Ces deux méthodes sont applicables aux cuirs vernis indépendamment de leurs utilisations finales.

Usnje - Fizikalni in mehanski preskusi - Odpornost lakastega usnja proti vročini

General Information

Status
Withdrawn
Publication Date
31-Jan-2003
Withdrawal Date
30-Mar-2009
Technical Committee
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
30-Mar-2009
Due Date
22-Apr-2009
Completion Date
31-Mar-2009

Relations

Buy Standard

Standard
EN 13540:2003
English language
10 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Leder - Physikalische und mechanische Prüfungen - Wärmebeständigkeit von LacklederCuir - Essais physiques et mécaniques - Détermination de la résistance a la chaleur des cuirs vernisLeather - Physical and mechanical tests - Determination of heat resistance of patent leather59.140.30Usnje in krznoLeather and fursICS:Ta slovenski standard je istoveten z:EN 13540:2002SIST EN 13540:2003en01-februar-2003SIST EN 13540:2003SLOVENSKI
STANDARD



SIST EN 13540:2003



EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 13540December 2002ICS 59.140.30English versionLeather - Physical and mechanical tests - Determination of heatresistance of patent leatherCuir - Essais physiques et mécaniques - Détermination dela résistance à la chaleur des cuirs vernisLeder - Physikalische und mechanische Prüfungen -Wärmebeständigkeit von LacklederThis European Standard was approved by CEN on 24 October 2002.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Management Centre has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece,Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2002 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 13540:2002 ESIST EN 13540:2003



EN 13540:2002 (E)2ContentspageForeword.31Scope.42Normative references.43Method A - Lastometer method.43.1Principle.43.2Apparatus.43.3Sampling and sample preparation.53.4Procedure.53.5Test Report.54Method B - Zwik method.64.1Principle.64.2Apparatus.64.3Sampling and sample preparation.74.4Procedure.84.5Test Report.8Annex A (informative) Sources of apparatus for Method A.9Annex B (informative) Sources of apparatus for Method B.10SIST EN 13540:2003



EN 13540:2002 (E)3ForewordThis document (EN 13540:2002) has been prepared by Technical Committee CEN/TC 289, "Leather", thesecretariat of which is held by UNI.This European Standard shall be given the status of a national standard, either by publication of an identical text orby endorsement, at the latest by June 2003, and conflicting national standards shall be withdrawn at the latest byJune 2003.Annexes A and B are informative.According to the CEN/CENELEC Internal Regulations, the national standards organizations of the followingcountries are bound to implement this European Standard: Austria, Belgium, Czech Republic, Denmark, Finland,France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Spain,Sweden, Switzerland and the United Kingdom.SIST EN 13540:2003



EN 13540:2002 (E)41 ScopeThis European Standard specifies two methods for determining the heat resistance of patent leather.
Method Amakes use of a modified lastometer whilst Method B uses the ‘Zwik’ apparatus.
Both methods are applicable topatent leathers for all end uses.2 Normative referencesThis European Standard incorporates by dated or undated reference, provisions from other publications. Thesenormative references are cited at the appropriate places in the text and the publications are listed hereafter. Fordated references, subsequent amendments to or revisions of any of these publications apply to this EuropeanStandard only when incorporated in it by amendment or revision. For undated references the latest edition of thepublication referred to applies (including amendments).prEN ISO 2418, Leather - Chemical, physical and mechanical and fastness tests - Sampling location (ISO/FDIS2418:2001)prEN ISO 2419, Leather - Physical and mechanical tests - Sample preparation and conditioning(ISO/FDIS 2419:2001)3 Method A - Lastometer method3.1 PrincipleA perforated test piece is distended by a specified amount. The surface is heated and any damage to the patentfinish is noted.3.2 Apparatus3.2.1A test machine, including the parts described in 3.2.1.1 to 3.2.1.4.3.2.1.1Clamp, capable of holding the test piece around its edge leaving free a central circular area ofdiameter 25,0 mm
0,1 mm. The design of its clamping system shall ensure that the test piece does not slip underthe test conditions and neither stretches nor compresses the central area as it is clamped. The boundary betweenthe free and clamped area shall be sharply defined.3.2.1.2Plunger, terminating in a steel ball of diameter 21,0 mm
0,1 mm.3.2.1.3Mechanism for thrusting the steel ball, without rotation against the test specimen.3.2.1.4Mechanism for monitoring the distension of the steel ball, (travel from zero) to an accuracy of
0,05mm.3.2.2Press knife, conforming to the requirements of prEN ISO 2419 for cutting test pieces of suitable dimensionsfor the test machine.3.2.3Sewing machine needle, sharp and undamaged, PCL size 80, either fitted into holder suitable for use byhand or into sewing machine.NOTEOther sized needles may be used if they are more appropriate to the sewing used in the shoe production.3.2.4Hot air blower, capable of maintaining a temperature of 100 °C
5 °C or 125 °C
5 °C.3.2.5Temperature measuring device, reading to 1 °C.3.2.6Stopwatch, reading to 1s.SIST EN 13540:2003



EN 13540:2002 (E)53.2.7Soft rubber mats, minimum thickness 10 mm.3.3 Sampling and sample preparation3.3.1Sample in accordance with prEN ISO 2418. Cut 3 test pieces by applying the press knife (3.2.2) to thepatent surface.NOTEIf there is a requirement for more than two hides or skins to be tested in one batch, then only one sample need betaken from each hide or skin, provided that the overall total is not less than three test pieces.3.3.2If the t
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.