Radio-frequency connectors - Part 45: Sectional specification for series SQMA series quick lock RF coaxial connectors

EN IEC 61169-45, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for type SQMA quick lock RF coaxial connectors. The connectors are normally used with 50 O in microwave, telecommunication, wireless and other fields, connecting with RF cables or micro-strips. The operating frequency limit is up to 18 GHz. It describes the interface dimensions for general purpose connectors grade 2 and standard test connectors - grade 0 with gauging information and the mandatory tests selected from IEC 61169-1, applicable to all detail specifications relative to type SQMA connectors. This specification indicates the recommended performance characteristics to be considered when writing a DS and covers all tests schedules and inspection requirements for assessment levels M and H.

Hochfrequenz-Steckverbinder - Teil 45: Rahmenspezifikation für koaxiale HF-Steckverbinder der SQMA-Serie mit Schnellverriegelung

Connecteurs pour fréquences radioélectriques - Partie 45: Spécification intermédiaire relative aux connecteurs coaxiaux RF à verrouillage rapide, série SQMA

L'IEC 61169-45:2014, qui est une spécification intermédiaire (SI), fournit des informations et des règles en vue de l'établissement de spécifications particulières (SP) de connecteurs coaxiaux RF de type SQMA à verrouillage rapide. Les connecteurs sont normalement utilisés avec une valeur de 50 Ohms dans des appareils communiquant sans fil, en hyperfréquences, de télécommunications ainsi que dans d'autres domaines, permettant la connexion avec les câbles RF ou les microrubans. La limite de fréquence de fonctionnement est inférieure ou égale à 18 GHz. Elle décrit également les dimensions d'interface pour des connecteurs d'usage général de classe 2, et des connecteurs d'essai normalisés - classe 0, ainsi que des informations concernant les calibres et les essais obligatoires choisis dans l'IEC 61169-1, applicables à toutes les spécifications particulières ayant trait aux connecteurs de la série SQMA. La présente spécification indique les caractéristiques de performance recommandées à prendre en compte pour la rédaction d'une spécification particulière, et elle couvre les programmes d'essais et les exigences de contrôle pour les niveaux d'assurance qualité M et H.

Radiofrekvenčni konektorji - 45. del: Oddelčna specifikacija za koaksialne zaklepne RF-konektorje serije SQMA (IEC 61169-45:2014)

Standard EN IEC 61169-45, ki je oddelčna specifikacija, podaja informacije in pravila za pripravo podrobnih specifikacij za koaksialne zaklepne RF-konektorje tipa SQMA. Konektorji se običajno uporabljajo s 50 O v mikrovalovnih, telekomunikacijskih, brezžičnih in drugih poljih, pri čemer se povezujejo z RF-kabli ali mikrotrakovi. Omejitev frekvenčnega območja delovanja je do 18 GHz. Opisuje dimenzije vmesnika za konektorje za splošni namen tipa 2 in standardne preskusne konektorje tipa 0 z informacijami o merjenju in obvezne preskuse, izbrane iz standarda IEC 61169-1, ki se uporabljajo za vse podrobne specifikacije v zvezi s konektorji tipa SQMA. Ta specifikacija določa priporočene lastnosti, ki jih je treba upoštevati pri sestavljanju podrobne specifikacije ter zajema vse urnike preskusov in zahteve za pregled za ravni vrednotenja M in H.

General Information

Status
Published
Publication Date
08-Sep-2014
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
05-Sep-2014
Due Date
10-Nov-2014
Completion Date
09-Sep-2014

Buy Standard

Standard
EN 61169-45:2014
English language
28 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 61169-45:2014
01-oktober-2014
5DGLRIUHNYHQþQLNRQHNWRUMLGHO2GGHOþQDVSHFLILNDFLMD]DNRDNVLDOQH
]DNOHSQH5)NRQHNWRUMHVHULMH640$ ,(&
Radio-frequency connectors - Part 45: Sectional specification for series SQMA series
quick lock RF coaxial connectors
Ta slovenski standard je istoveten z: EN 61169-45:2014
ICS:
33.120.30 5DGLRIUHNYHQþQLNRQHNWRUML R.F. connectors
5)
SIST EN 61169-45:2014 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 61169-45:2014

---------------------- Page: 2 ----------------------

SIST EN 61169-45:2014


EUROPEAN STANDARD EN 61169-45

NORME EUROPÉENNE

EUROPÄISCHE NORM
August 2014
ICS 33.120.30

English Version
Radio-frequency connectors -Part 45: Sectional specification for
series SQMA series quick lock RF coaxial connectors
(IEC 61169-45:2014)
Connecteurs pour fréquences radioélectriques - Partie 45: Hochfrequenz-Steckverbinder - Teil 45:
Spécification intermédiaire relative aux connecteurs Rahmenspezifikation für koaxiale HF Steckverbinder der
coaxiaux RF à verrouillage rapide, série SQMA SQMA-Serie mit Schnellverriegelung
(CEI 61169-45:2014) (IEC 61169-45:2014)
This European Standard was approved by CENELEC on 2014-06-27. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.



European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2014 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
 Ref. No. EN 61169-45:2014 E

---------------------- Page: 3 ----------------------

SIST EN 61169-45:2014
EN 61169-45:2014 - 2 -

Foreword
The text of document 46F/238/CDV, future edition 1 of IEC 61169-45, prepared by SC 46F, "R.F. and
microwave passive components", of IEC TC 46, "Cables, wires, waveguides, R.F. connectors, R.F. and
microwave passive components and accessories" was submitted to the IEC-CENELEC parallel vote and
approved by CENELEC as EN 61169-45:2014.
The following dates are fixed:
(dop) 2015-03-27
• latest date by which the document has
to be implemented at national level by
publication of an identical national
standard or by endorsement
• latest date by which the national (dow) 2017-06-27
standards conflicting with the
document have to be withdrawn

Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such patent
rights.
Endorsement notice
The text of the International Standard IEC 61169-45:2014 was approved by CENELEC as a European
Standard without any modification.

---------------------- Page: 4 ----------------------

SIST EN 61169-45:2014
- 3 - EN 61169-45:2014

Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod), the relevant EN/HD

applies.
NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available here:
www.cenelec.eu.
Publication Year Title EN/HD Year
IEC 61169-1 2013 Radio-frequency connectors -- Part 1: EN 61169-1 2013
Generic specification - General
requirements and measuring methods

---------------------- Page: 5 ----------------------

SIST EN 61169-45:2014

---------------------- Page: 6 ----------------------

SIST EN 61169-45:2014




IEC 61169-45

®


Edition 1.0 2014-05




INTERNATIONAL



STANDARD




NORME



INTERNATIONALE
colour

inside










Radio-frequency connectors –

Part 45: Sectional specification for SQMA series quick lock RF coaxial

connectors




Connecteurs pour fréquences radioélectriques –

Partie 45: Spécification intermédiaire relative aux connecteurs coaxiaux RF à


verrouillage rapide, série SQMA













INTERNATIONAL

ELECTROTECHNICAL

COMMISSION


COMMISSION

ELECTROTECHNIQUE

PRICE CODE
INTERNATIONALE

CODE PRIX T


ICS 33.120.30 ISBN 978-2-8322-1628-6



Warning! Make sure that you obtained this publication from an authorized distributor.

Attention! Veuillez vous assurer que vous avez obtenu cette publication via un distributeur agréé.

® Registered trademark of the International Electrotechnical Commission
Marque déposée de la Commission Electrotechnique Internationale

---------------------- Page: 7 ----------------------

SIST EN 61169-45:2014
– 2 – IEC 61169-45:2014 © IEC 2014

CONTENTS

FOREWORD . 4
1 Scope . 6
2 Normative references . 6
3 Mating face and gauge information . 6
3.1 Dimensions – General connectors – Grade 2 . 6
3.1.1 Connector with pin-centre contact (see Figure 1) . 6
3.1.2 Connector with socket-centre contact (see Figure 2) . 8
3.2 Gauges . 9
3.2.1 Gauge pins for socket-centre contact (see Figure 3) . 9
3.2.2 Test procedure . 9
3.3 Dimensions – Standard test connectors – Grade 0 . 10
3.3.1 Connector with pin-centre contact (see Figure 4) . 10
3.3.2 Connector with socket-centre contact (see Figure 5) . 11
4 Quality assessment procedure . 12
4.1 General . 12
4.2 Ratings and characteristics . 12
4.3 Test schedule and inspection requirements . 15
4.3.1 Acceptance tests . 15
4.3.2 Periodic tests . 16
4.4 Procedures for quality conformance . 17
4.4.1 Quality conformance inspection . 17
4.4.2 Quality conformance and its maintenance . 17
4.5 Test and measurement procedures . 17
4.5.1 General . 17
4.5.2 Schedule of basic test groupings for acceptance and periodic tests . 17
4.6 Specifications . 18
4.6.1 Specification structures . 18
4.6.2 Sectional specification (SS) . 18
4.6.3 Detail specification (DS) . 18
4.6.4 Blank detail specification (BDS) . 18
4.6.5 Blank detail specification pro-forma for SQMA connectors . 20
5 Marking . 24
5.1 Marking of component . 24
5.2 Marking and contents of package . 25

Figure 1 – Connector with pin-centre contact (for dimensions and key, see Table 1) . 7
Figure 2 – Connector with socket-centre contact (for dimensions andkey, see Table 2) . 8
Figure 3 – Gauge pins for socket-centre contact (for dimensions, see Table 3) . 9
Figure 4 – Connector with pin-centre contact (for dimensions and key, see Table 4) . 10
Figure 5 – Connector with socket-centre contact (for dimensions and key, see Table 5) . 11

---------------------- Page: 8 ----------------------

SIST EN 61169-45:2014
IEC 61169-45:2014 © IEC 2014 – 3 –
Table 1 – Dimensions of connector with pin-centre contact . 7
Table 2 – Dimensions of connector with socket-centre contact . 8
Table 3 – Dimensions of gauge pins for socket-centre contact . 9
Table 4 – Dimensions of connector with pin-centre contact . 10
Table 5 – Dimensions of connector with socket-centre contact . 11
Table 6 – Climatic categories . 12
Table 7 – Ratings and characteristics . 12
Table 8 – Acceptance tests . 15
Table 9 – Periodic tests . 16

---------------------- Page: 9 ----------------------

SIST EN 61169-45:2014
– 4 – IEC 61169-45:2014 © IEC 2014
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________

RADIO-FREQUENCY CONNECTORS –

Part 45: Sectional specification for SQMA
series quick lock RF coaxial connectors

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61169-45 has been prepared by subcommittee 46F: R.F. and
microwave passive components, of IEC technical committee 46: Cables, wires, waveguides,
R.F. connectors, R.F. and microwave passive components and accessories.
The text of this standard is based on the following documents:
CDV Report on voting
46F/238/CDV 46F/256/RVC

Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.

---------------------- Page: 10 ----------------------

SIST EN 61169-45:2014
IEC 61169-45:2014 © IEC 2014 – 5 –
A list of all parts of the IEC 61169 series, under the general title: Radio-frequency connectors,
can be found on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.

IMPORTANT – The 'colour inside' logo on the cover page of this publication indicates
that it contains colours which are considered to be useful for the correct
understanding of its contents. Users should therefore print this document using a
colour printer.

---------------------- Page: 11 ----------------------

SIST EN 61169-45:2014
– 6 – IEC 61169-45:2014 © IEC 2014
RADIO-FREQUENCY CONNECTORS –

Part 45: Sectional specification for SQMA
series quick lock RF coaxial connectors



1 Scope
This part of IEC 61169, which is a sectional specification (SS), provides information and rules
for the preparation of detail specifications (DS) for type SQMA quick lock RF coaxial
connectors.
The connectors are normally used with 50 Ω in microwave, telecommunication, wireless and
other fields, connecting with RF cables or micro-strips. The operating frequency limit is up to
18 GHz.
It describes the interface dimensions for general purpose connectors grade 2 and standard
test connectors – grade 0 with gauging information and the mandatory tests selected from
IEC 61169-1, applicable to all detail specifications relative to type SQMA connectors.
This specification indicates the recommended performance characteristics to be considered
when writing a DS and covers all tests schedules and inspection requirements for assessment
levels M and H.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and
are indispensable for its application. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC 61169-1:2013, Radio-frequency connectors – Part 1: Generic specification – General
requirements and measuring methods
3 Mating face and gauge information
3.1 Dimensions – General connectors – Grade 2
3.1.1 Connector with pin-centre contact (see Figure 1)
Metric dimension are original dimensions. All undimensioned pictorial configurations are for
reference purpose only.

---------------------- Page: 12 ----------------------

SIST EN 61169-45:2014
IEC 61169-45:2014 © IEC 2014 – 7 –
(1)
e
(2)
(3)
(5)
(4)
(3)
g
p
h
m
j
IEC  1822/14

Figure 1 – Connector with pin-centre contact (for dimensions and key, see Table 1)
Table 1 – Dimensions of connector with pin-centre contact
Ref. mm Additional notes
Min. Max.
a – 11,50
b 4,98 5,02
c 5,62 5,68
d – 4,18
e – 7,50 (6)
g 0,00 0,25
h 0,00 0,25
j – 2,54
k – 0,30
m 1,27 –
p 1,70 2,00
r – – (7)
s 0,90 0,94
(1) Mechanical and electrical reference plane.
(2) Design and location of the seal ring are optional, but shall meet environmental requirements.
(3) Chamfer.
(4) No chamfer, undercut acceptable.
(5) Design of spring is optional, but shall meet mechanical requirement.
(6) Prefix locknut (maximal dimension).
(7) Diameter is chosen to obtain a normal impedance of 50 Ω and meet electrical and mechanical
requirements.
Ør
Øk
Øs
Ød
Øb
Øc
Øa

---------------------- Page: 13 ----------------------

SIST EN 61169-45:2014
– 8 – IEC 61169-45:2014 © IEC 2014
3.1.2 Connector with socket-centre contact (see Figure 2)
(1)
e
f
p
(2)
n
g
h
j
IEC  1823/14

Figure 2 – Connector with socket-centre contact (for dimensions andkey, see Table 2)
Table 2 – Dimensions of connector with socket-centre contact
Ref. mm Additional notes
Min. Max.
a – 4,95
b 4,90 4,95
c 5,55 5,59
d – 4,18
e 7,60 –
f 3,97 4,00
g – 0,25
h – 0,25
j 2,82 –
n 2,00 2,50
p 3,20 3,40
r – – (3)
s – – (4)
o o
t 49 51 Angle
(1) Mechanical and electrical reference plane.
(2) Design of chamfer is optional, but shall meet mechanical requirements.
(3) Diameters are chosen to obtain a normal impedance of 50 Ω and meet electrical and mechanical
requirements.
(4) Design for slotting optional, and should meet electrical and mechanical requirements, when mating with
∅0,90 mm ~ ∅0,94 mm pin.

Øc
Øb
Øs
Ør
Ød
Øa

---------------------- Page: 14 ----------------------

SIST EN 61169-45:2014
IEC 61169-45:2014 © IEC 2014 – 9 –
3.2 Gauges
3.2.1 Gauge pins for socket-centre contact (see Figure 3)
50° ±10°
Øa
R0,4 mm max.
IEC  1824/14

Figure 3 – Gauge pins for socket-centre contact (for dimensions, see Table 3)
Table 3 – Dimensions of gauge pins for socket-centre contact
Gauge A Gauge B
Maximum material for sizing purposes Minimum material for measurement
of retention force
Mass of gauge: 28 g +2 g
mm mm
Ref.
Min. Max. Min. Max.
a 0,940 0,945 0,899 0,902
b 0,76 1,14 1,27 1,90
Material: steel, polished.
Surface roughness: Ra ≤ 0,4 µm on the cylindrical surface of length b.

3.2.2 Test procedure
The gauge A shall be inserted into the socket-centre contact three times with a minimum
depth of 0,76 mm. This is a sizing operation and should only be carried out when the socket-
centre contact is removed from the connector.
After this, the gauge B shall be inserted into socket-centre contact. The contact shall retain
the mass of the gauge in a vertical downward position. The test also shall be carried out on
connector when the socket-centre contact is not removed.
b

---------------------- Page: 15 ----------------------

SIST EN 61169-45:2014
– 10 – IEC 61169-45:2014 © IEC 2014
3.3 Dimensions – Standard test connectors – Grade 0
3.3.1 Connector with pin-centre contact (see Figure 4)
0,013 mm A
(1)
e
(2)
(3) (5)
(4)
(3)
A
g
p
Ø0,025 mm A
Ø0,013 mm B
h
m
B j
IEC  1825/14

Figure 4 – Connector with pin-centre contact (for dimensions and key, see Table 4)
Table 4 – Dimensions of connector with pin-centre contact
Ref. mm Additional notes
Min. Max.
a – 11,50
b 4,98 5,00
c 5,62 5,68
d 4,10 4,13
e – 7,50 (6)
g – 0,05
h – 0,08
j 2,03 2,29
k – 0,30
m 1,27 –
p 1,70 2,00
r 1,27 nominal (7)
s 0,92 0,94
(1) Mechanical and electrical reference plane.
(2) Design and location of the seal ring are optional, but shall meet environmental requirements.
(3) Chamfer.
(4) No chamfer, undercut acceptable.
(5) Design of spring is optional, but shall meet mechanical requirements performance.
(6) Prefix locknut (maximal dimension).
(7) Diameters are chosen to obtain a normal impedance of 50 Ω ± 0,5 Ω and meet electrical and mechanical
requirements.
Ør
Øk
Øs
Ød
Øb
Øc
Øa

---------------------- Page: 16 ----------------------

SIST EN 61169-45:2014
IEC 61169-45:2014 © IEC 2014 – 11 –
3.3.2 Connector with socket-centre contact (see Figure 5)
(1)
e
f
(2)
p
n
g
A
0,013 mm A
Ø0,025 mm A
h
Ø0,013 mm B
j
IEC  1826/14

Figure 5 – Connector with socket-centre contact (for dimensions and key, see Table 5)
Table 5 – Dimensions of connector with socket-centre contact
Ref. mm Additional notes
Min. Max.
a – 4,95
b 4,92 4,95
c 5,55 5,56
d 4,10 4,13
e 7,60 –
f 3,97 4,00
g – 0,05
h – 0,08
j 2,82 –
n 2,00 2,20
p 3,20 3,40
r 1,27 nominal (3)
s – – (4)
o o
t 49 51
(1) Mechanical and electrical reference plane.
(2) Design of chamfer is optional, but shall meet mechanical requirements.
(3) Diameters are chosen to obtain a normal impedance of 50 Ω ± 0,5 Ω.
(4) Design for slotting optional, and should meet electrical and mechanical requirements when mating with
∅0,92 mm ~ ∅0,94 mm pin.

Øc
Øb
Øs
Ør
Ød
Øa

---------------------- Page: 17 ----------------------

SIST EN 61169-45:2014
– 12 – IEC 61169-45:2014 © IEC 2014
4 Quality assessment procedure
4.1 General
The subclauses of this Clause 4 provide recommended ratings, performance and test
conditions to be considered when writing a detail specification (DS). They also provide an
appropriate schedule of tests with minimum levels of conformance.
4.2 Ratings and characteristics
The values indicated below in Tables 6 and 7 are recommended for type SQMA connectors
and are given for the writer of the detail specification. They are applicable for the condition
when the connectors are fully mated.
Certain tests will usually not be required. When these tests are required, appropriate values
shall be entered in the detail specification at the discretion of the specification writer.
Table 6 – Climatic categories
Category designation Letter Temperature range Damp heat steady state
65/125/51 –65 °C to +125 °C

Table 7 – Ratings and characteristics
Ratings and characteristics Test method Value Remarks, deviation
IEC 61169-1:2013 from standard test
subclause method
Electrical

Nominal impedance 50 Ω
Or upper frequency
Frequency range DC to 18 GHz
limit of cable
a
Reflection factor 9.2.1
Straight styles
– High performance connectors Up to 6 GHz
≤0,06
Semi rigid/semi flexible cables ≤0,13 6 GHz to 18 GHz
Flexible cables See DS
– Right angle styles See DS
Semi rigid/semi flexible cables See DS
Solder bucket and PCB mounting style See DS
– Component mounting styles See DS
Insertion loss
<0,05 × √ f (GHz)
b
Centre contact resistance 9.2.3
– initial ≤ 3,5 mΩ

– after tests ≤ 5,5 mΩ
b
Outer contact continuity 9.2.3
– initial
3 mΩ
– after tests 5 mΩ
Insulation resistance 9.2.5

– initial 5 000 MΩ
– after tests
200 MΩ
cd
Proof voltage

---------------------- Page: 18 ----------------------

SIST EN 61169-45:2014
IEC 61169-45:2014 © IEC 2014 – 13 –
Ratings and characteristics Test method Value Remarks, deviation
IEC 61169-1:2013 from standard test
subclause method
– at sea level
1 000 Vrms
– cables 96 IEC 50-3
750 Vrms
– cables 96 IEC 50-2
9.2.6 500 Vrms
– cables 96 IEC 50-1
1 000 Vrms
– semi-rigid 3,58 mm (0,141 in)
750 Vrms
– semi-rigid 2,18 mm (0,086 in)
– at 4,4 kPa
200 Vrms
– cables 96 IEC 50-3
150 Vrms
– cables 96 IEC 50-2
9.2.6 100 Vrms
– cables 96 IEC 50-1
200 Vrms
– semi-rigid 3,58 mm (0,141 in)
150 Vrms
– semi-rigid 2,18 mm (0,086 in)
e

Screening effectiveness 9.2.7 ≥60 dB, at 1 GHz
Intermodulation level 9.2.9 na
Mechanical
Maximum
displacement of
Centre contact captivation 9.3.5
0,25 mm in any
directions
– axial force  26,7 N
– torque 0,028 N.m
Engagement and separation force 9.3.6
– axial force (engagement) ≤ 25N
– axial force (separation) ≤ 25 N
– torque na
Gauge retention force 9.3.4
– centre contact  ≥ 0,28 N
– outer contact
– torque N.m
Mechanical tests on cable fixing
– cable rotation (nutation) 9.3.7 See DS
– cable pulling 9.3.8 See DS
– cable bending 9.3.9 See DS
– cable torsion 9.3.10 See DS
Tensile strength of coupling
9.3.11 ≥ 60 N
mechanism
Bending moment of coupling
9.3.12 na
mechanism
2
50 m/s
Vibration 9.3.3 5 g
n
10 Hz to 500 Hz
2
150 m/s
Shock 9.3.14 half-sine wave 15 g
n
11 ms

---------------------- Page: 19 ----------------------

SIST EN 61169-45:2014
– 14 – IEC 61169-45:2014 © IEC 2014
Ratings and characteristics Test method Value Remarks, deviation
IEC 61169-1:2013 from standard test
subclause method
Endurance
Mechanical endurance 9.3.15 200 operations
High temperature endurance 9.4.5 250 h at 125 °C
Environmental

Climatic sequence
– storage 9.4.2 55/125/51
Sealing 9.4.7 na
Salt mist 9.4.10 48 h spray
Sulphur dioxide test 9.4.12
Change of temperature 9.4.4
f
– dry heat +85 °C
– cold –55 °C
– damp heat 9.4.3
a
Characteristics indicated are those that can be applied to basic connector. Intrinsic limitations of the cable
may diminish the performance of the assembly and reference should always be made to the actual values
given in the detail specification.
b
Values for a single pair of connectors.
c
Voltage are r.m.s. values of a.c. from 40 Hz to 65 Hz, unless otherwise specified.
d
Values are depending also of the cable type.
e
Applicable in fully mated position. Depending on cable type values for a single pair of connectors.
f Upper temperature limit can be restricted by the cable characteristics. Reference should be applied
according the relevant cable specification.

---------------------- Page: 20 ----------------------

SIST EN 61169-45:2014
IEC 61169-45:2014 © IEC 2014 – 15 –
4.3 Test schedule and inspection requirements
4.3.1 Acceptance tests
Table 8 describes the acceptance tests to be performed.
Table 8 – Acceptance tests
IEC 61169-1:2013 Assessment level M (higher) Assessment level H (lower)
– subclause Test IL AQL Period Test IL AQL Period
required % required %

Group A1
Visual examination 9.1.1 a II 1 a S3 1,5
Group B1
Outline dimension 9.1.2 a S4 0,4 a S3 4
Mechanical 9.1.2.2 a II 1 a S3 1,5
compatibility
Engagement and 9.3.6 a S4 0,4 a S3 1,5
separation
Gauge retention 9.3.5 ia II 1 ia S3 1,5
(resilient contacts)
Insertion retention 9.3.4 ia ll 1 ia S3 1,5
force (resilient
contacts)
Sealing
non hermetic 9.4.7 ia II 0,65 ia S3 1
hermetic 9.4.8 ia II 0,015 ia S3 0,025
Water immersion 9.4.9 ia II 0,015 ia S3 0,025
Voltage proof 9.2.6 a II 0,4 a II 4
Solderability (d) 9.3.2.2 ia S4 0,4 ia S3 4
Insulation 9.2.5 a S4 0,4 a S3 4
resistance
For the symbols, abbreviations and procedures, see the end of Table 9.


Lot-by-lot
Lot-by-lot

---------------------- Page: 21 ----------------------

SIST EN 61169-45:2014
– 16 – IEC 611
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.