Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz - 300 GHz)

EN-IEC 62311 applies to electronic and electrical equipment for which no dedicated product standard or product family standard regarding human exposure to electromagnetic fields applies. It covers equipment with intentional or non-intentional radiators as well as a combination thereof. This document provides assessment methods and criteria to evaluate equipment against limits on exposure of people related to electric, magnetic and electromagnetic fields. The frequency range covered is from 0 Hz to 300 GHz. This document does not specify limits expressed by means of basic restrictions and/or reference levels. Such limits are subject to the applied assessment scheme, for example by means of regional limits.

Bewertung von elektrischen und elektronischen Einrichtungen in Bezug auf Begrenzungen der Exposition von Personen in elektromagnetischen Feldern (0 Hz - 300 GHz)

Evaluation des équipements électroniques et électriques en relation avec les restrictions d'exposition humaine aux champs électromagnétiques (0 Hz - 300 GHz)

IEC 62311:2019 s’applique aux équipements électroniques et électriques auxquels aucune norme concernant l'exposition humaine aux champs électromagnétiques, dédiée à un produit ou à une famille de produits, ne s'applique. Il couvre les équipements à émetteurs intentionnels ou non intentionnels ainsi qu’une combinaison de ceux-ci.
Le présent document fournit des méthodes et des critères d’évaluation pour démontrer que les équipements satisfont aux limites d’exposition des personnes aux champs électriques, magnétiques et électromagnétiques. La plage de fréquences couverte s’étend de 0 Hz à 300 GHz.
Cette deuxième édition annule et remplace la première édition parue en 2007. Cette édition constitue une révision technique.
Le présent document ne spécifie pas de limites d’exposition, ni sous la forme de restrictions de base ni sous la forme de niveaux de référence. Ces limites, exprimées par exemple sous forme de limites régionales, sont soumises au système d’évaluation appliqué.
Cette édition inclut les modifications techniques majeures suivantes par rapport à l'édition précédente:
a) une distinction claire a été faite entre les émetteurs intentionnels et non intentionnels;
b) l’exposition à des champs non uniformes est prise en considération;
c) le traitement de l’incertitude des procédures d’évaluation a été amélioré;
d) différents régimes de sommation sont décrits dans l'Annexe A;
e) les informations présentes dans des normes de base publiées entre-temps ont été utilisées, ce qui explique la suppression de toutes les annexes informatives de l’édition précédente.
Mots clés: exposition humaine, champs électromagnétiques (0 Hz à 300 GHz)

Ocena elektronske in električne opreme glede omejevanja izpostavljenosti ljudi elektromagnetnim sevanjem (0 Hz - 300 GHz)

General Information

Status
Published
Publication Date
15-Apr-2020
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
12-Mar-2020
Due Date
17-May-2020
Completion Date
16-Apr-2020

Relations

Buy Standard

Standard
EN IEC 62311:2020 - BARVE
English language
37 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN IEC 62311:2020
01-maj-2020
Nadomešča:
SIST EN 62311:2008
Ocena elektronske in električne opreme glede omejevanja izpostavljenosti ljudi
elektromagnetnim sevanjem (0 Hz - 300 GHz)
Assessment of electronic and electrical equipment related to human exposure
restrictions for electromagnetic fields (0 Hz - 300 GHz)
Bewertung von elektrischen und elektronischen Einrichtungen in Bezug auf
Begrenzungen der Exposition von Personen in elektromagnetischen Feldern (0 Hz - 300
GHz)
Evaluation des équipements électroniques et électriques en relation avec les restrictions
d'exposition humaine aux champs électromagnétiques (0 Hz - 300 GHz)
Ta slovenski standard je istoveten z: EN IEC 62311:2020
ICS:
13.280 Varstvo pred sevanjem Radiation protection
SIST EN IEC 62311:2020 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
SIST EN IEC 62311:2020

---------------------- Page: 2 ----------------------
SIST EN IEC 62311:2020


EUROPEAN STANDARD EN IEC 62311

NORME EUROPÉENNE

EUROPÄISCHE NORM
January 2020
ICS 97.030 Supersedes EN 62311:2008 and all of its amendments
and corrigenda (if any)
English Version
Assessment of electronic and electrical equipment related to
human exposure restrictions for electromagnetic fields (0 Hz to
300 GHz)
(IEC 62311:2019)
Évaluation des équipements électroniques et électriques en Bewertung von elektrischen und elektronischen
relation avec les restrictions d'exposition humaine aux Einrichtungen in Bezug auf Begrenzungen der Exposition
champs électromagnétiques (0 Hz à 300 GHz) von Personen in elektromagnetischen Feldern (0 Hz - 300
(IEC 62311:2019) GHz)
(IEC 62311:2019)
This European Standard was approved by CENELEC on 2019-05-23. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.


European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2020 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
 Ref. No. EN IEC 62311:2020 E

---------------------- Page: 3 ----------------------
SIST EN IEC 62311:2020
EN IEC 62311:2020 (E)
European foreword
The text of document 106/480/FDIS, future edition 2 of IEC 62311, prepared by IEC/TC 106 "Methods
for the assessment of electric, magnetic and electromagnetic fields associated with human exposure"
was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as
EN IEC 62311:2020.
The following dates are fixed:
• latest date by which the document has to be implemented at national (dop) 2020-07-24
level by publication of an identical national standard or by endorsement
• latest date by which the national standards conflicting with the (dow) 2023-01-24
document have to be withdrawn

This document supersedes EN 62311:2008 and all of its amendments and corrigenda (if any).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights.

Endorsement notice
The text of the International Standard IEC 62311:2019 was approved by CENELEC as a European
Standard without any modification.

In the official version, for Bibliography, the following notes have to be added for the standards
indicated:
ISO/IEC 17025 NOTE Harmonized as EN ISO/IEC 17025
CISPR 32 NOTE Harmonized as EN 55032
IEC 61786-1:2013 NOTE Harmonized as EN 61786-1:2014 (not modified)
IEC 62110:2009 NOTE Harmonized as EN 62110:2009/AC:2015 (not modified)
IEC 62209-1:2016 NOTE Harmonized as EN 62209-1:2016 (not modified)
IEC 62209-2:2010 NOTE Harmonized as EN 62209-2:2010 (not modified)

2

---------------------- Page: 4 ----------------------
SIST EN IEC 62311:2020
EN IEC 62311:2020 (E)
Annex ZA
(normative)

Normative references to international publications
with their corresponding European publications
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments)
applies.
NOTE 1  Where an International Publication has been modified by common modifications, indicated by (mod), the relevant
EN/HD applies.
NOTE 2  Up-to-date information on the latest versions of the European Standards listed in this annex is available here:
www.cenelec.eu.

Publication Year Title EN/HD Year
IEC 60050-161 1990 International Electrotechnical Vocabulary. - -
Chapter 161: Electromagnetic compatibility
Determination of RF field strength, power
IEC 62232 2017  EN 62232 2017
density and SAR in the vicinity
ofradiocommunication base stations for the
purpose of evaluating human exposure



3

---------------------- Page: 5 ----------------------
SIST EN IEC 62311:2020

---------------------- Page: 6 ----------------------
SIST EN IEC 62311:2020




IEC 62311

®


Edition 2.0 2019-04




INTERNATIONAL



STANDARD




NORME



INTERNATIONALE
colour

inside










Assessment of electronic and electrical equipment related to human exposure

restrictions for electromagnetic fields (0 Hz to 300 GHz)



Évaluation des équipements électroniques et électriques en relation avec les

restrictions d'exposition humaine aux champs électromagnétiques (0 Hz à 300 GHz)
















INTERNATIONAL

ELECTROTECHNICAL

COMMISSION


COMMISSION

ELECTROTECHNIQUE


INTERNATIONALE




ICS 97.030 ISBN 978-2-8322-6763-9



Warning! Make sure that you obtained this publication from an authorized distributor.

Attention! Veuillez vous assurer que vous avez obtenu cette publication via un distributeur agréé.

® Registered trademark of the International Electrotechnical Commission
Marque déposée de la Commission Electrotechnique Internationale

---------------------- Page: 7 ----------------------
SIST EN IEC 62311:2020
– 2 – IEC 62311:2019 © IEC 2019
CONTENTS
FOREWORD . 4
1 Scope . 6
2 Normative references . 6
3 Terms, definitions and abbreviated terms . 6
3.1 Terms and definitions . 6
3.2 Abbreviated terms . 10
4 Compliance criteria . 10
5 Performance of assessments . 11
5.1 Assessment methods . 11
5.2 Frequency range under assessment for unintentional radiation . 13
5.3 General procedure for the assessment of equipment . 13
6 Uncertainty . 17
6.1 General . 17
6.2 Consideration of uncertainty for compliance . 17
7 Considerations on sources with multiple frequencies and non-uniformity of fields . 19
7.1 Sources with multiple frequencies . 19
7.2 Exposure to non-uniform fields . 19
8 Evaluation of compliance to limits . 20
9 Assessment report . 20
9.1 General . 20
9.2 Items to be recorded in the assessment report . 20
9.2.1 Assessment method . 20
9.2.2 Presentation of the results . 20
9.2.3 Equipment using external antennas . 20
10 Product documentation . 20
Annex A (informative)  Examples for summation regimes . 21
A.1 ICNIRP 1998 summation regimes . 21
A.1.1 General . 21
A.1.2 Frequency range from 1 Hz to 10 MHz (ICNIRP 1998-based) . 21
A.1.3 Frequency range from 100 kHz to 300 GHz (ICNIRP 1998-based) . 25
A.2 ICNIRP 2010 summation regimes . 26
A.2.1 General . 26
A.2.2 Frequency domain assessment – ICNIRP 2010 Guidelines . 26
A.2.3 Time domain assessment – ICNIRP 2010 Guidelines . 29
A.3 IEEE summation regimes . 31
A.3.1 General . 31
A.3.2 Frequency range from 0 kHz to 5 MHz (IEEE-based) . 31
A.3.3 Frequency range from 3 kHz to 300 GHz (IEEE-based) . 32
Bibliography . 33

Figure 1 – Assessment flowchart . 15
Figure A.1 – Schematic of “weighting circuit” . 23

---------------------- Page: 8 ----------------------
SIST EN IEC 62311:2020
IEC 62311:2019 © IEC 2019 – 3 –
Figure A.2 – Dependency on frequency of the reference levels VL plotted with
 
dVL
smoothing edges with VL(f ) = VL , VL(f ) = V and the slopes . 24
1  
c0 0 c1
df
 
n
Figure A.3 – Transfer function WL . 24
Figure A.4 – Amplitude and phase response for the weighting function WL(f) of the
magnetic field (reference level for general public exposure) . 30

Table 1 – List of possible assessment methods . 11
Table 2 – Characteristics and parameters of the equipment to be considered . 16

---------------------- Page: 9 ----------------------
SIST EN IEC 62311:2020
– 4 – IEC 62311:2019 © IEC 2019
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________

ASSESSMENT OF ELECTRONIC AND ELECTRICAL EQUIPMENT
RELATED TO HUMAN EXPOSURE RESTRICTIONS
FOR ELECTROMAGNETIC FIELDS (0 Hz to 300 GHz)

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international
co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and
in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports,
Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their
preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with
may participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for
Standardization (ISO) in accordance with conditions determined by agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence between
any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent
rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 62311 has been prepared by IEC technical committee 106: Methods
for the assessment of electric, magnetic and electromagnetic fields associated with human
exposure.
This second edition cancels and replaces the first edition published in 2007. This edition
constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous
edition:
a) a clear distinction between intentional and unintentional radiators has been introduced;
b) the exposure to non-uniform fields is considered;
c) the treatment of uncertainty for the assessment procedures has been improved;
d) various summation regimes are described in Annex A;
e) the information from meanwhile published basic standards has been used and hence all
informative annexes of the previous edition have been removed.
The text of this International Standard is based on the following documents:

---------------------- Page: 10 ----------------------
SIST EN IEC 62311:2020
IEC 62311:2019 © IEC 2019 – 5 –
FDIS Report on voting
106/480/FDIS 106/486/RVD

Full information on the voting for the approval of this International Standard can be found in the
report on voting indicated in the above table.
This document has been drafted in accordance with the ISO/IEC Directives, Part 2.
The committee has decided that the contents of this document will remain unchanged until the
stability date indicated on the IEC website under "http://webstore.iec.ch" in the data related to
the specific document. At this date, the document will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.

IMPORTANT – The 'colour inside' logo on the cover page of this publication indicates
that it contains colours which are considered to be useful for the correct understanding
of its contents. Users should therefore print this document using a colour printer.

---------------------- Page: 11 ----------------------
SIST EN IEC 62311:2020
– 6 – IEC 62311:2019 © IEC 2019
ASSESSMENT OF ELECTRONIC AND ELECTRICAL EQUIPMENT
RELATED TO HUMAN EXPOSURE RESTRICTIONS
FOR ELECTROMAGNETIC FIELDS (0 Hz to 300 GHz)



1 Scope
This document applies to electronic and electrical equipment for which no dedicated product
standard or product family standard regarding human exposure to electromagnetic fields applies.
It covers equipment with intentional or non-intentional radiators as well as a combination thereof.
This document provides assessment methods and criteria to evaluate equipment against limits
on exposure of people related to electric, magnetic and electromagnetic fields. The frequency
range covered is from 0 Hz to 300 GHz.
NOTE 1 Further guidance concerning the application of this document and its relationship to other EMF standards
is given in Figure 1.
This document does not specify limits expressed by means of basic restrictions and/or reference
levels. Such limits are subject to the applied assessment scheme, for example by means of
regional limits.
NOTE 2 The assessment methods and criteria to evaluate equipment against basic restrictions or reference levels
can be used with regard to either general public or occupational exposure.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies.
For undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC 60050-161:1990, International Electrotechnical Vocabulary – Chapter 161:
Electromagnetic compatibility (available at http://www.electropedia.org)
IEC 62232:2017, Determination of RF field strength, power density and SAR in the vicinity of
radiocommunication base stations for the purpose of evaluating human exposure
3 Terms, definitions and abbreviated terms
3.1 Terms and definitions
For the purposes of this document, the terms and definitions given in IEC 60050-161 and the
following apply.
ISO and IEC maintain terminological databases for use in standardization at the following
addresses:
• IEC Electropedia: available at http://www.electropedia.org/
• ISO Online browsing platform: available at http://www.iso.org/obp

---------------------- Page: 12 ----------------------
SIST EN IEC 62311:2020
IEC 62311:2019 © IEC 2019 – 7 –
3.1.1
averaging time
t
avg
appropriate time interval over which exposure
is averaged for purposes of determining compliance
3.1.2
basic restriction
restriction on exposure to time-varying electric, magnetic and electromagnetic fields that is
based directly on established health effects
Note 1 to entry: Examples of basic restrictions can be found in Annex II of the Council Recommendation
1999/519/EC [1], ICNIRP Guidelines ([2], [3]), IEEE Std C95.6 [4] and IEEE Std C95.1 [5].
3.1.3
contact current
current flowing into the body resulting from contact with a conductive object
in an electromagnetic field
Note 1 to entry: This is the localized current flow into the body (usually the hand, for a light brushing contact).
3.1.4
current density
J
current per unit cross-sectional area flowing inside the human body as a result of exposure to
electromagnetic fields
3.1.5
duty factor
ratio of pulse duration to the pulse period of a
periodic pulse train
Note 1 to entry: A duty factor can also be considered as a measure of the temporal transmission characteristic of
an intermittently transmitting RF source such as a paging antenna by dividing average transmission duration by the
average period for transmissions.
Note 2 to entry: A duty factor of 1,0 corresponds to continuous operation.
3.1.6
effective radiated power
ERP
product of the power supplied by a radio transmitter to an antenna and the gain of this antenna
relative to a half-wave dipole in a given direction
[SOURCE: IEC 60050-713:1998, 713-09-26]
3.1.7
electric field strength
E
vector field quantity E which exerts on any charged particle at rest a force F equal to the product
of E and the electric charge Q of the particle
[SOURCE: IEC 60050-121:1998, 121-11-18]
3.1.8
exposure
situation that occurs wherever a person is subjected to electric, magnetic or electromagnetic
fields
Note 1 to entry: The word “exposure” is also commonly used to mean “exposure level” (see 3.1.9).

---------------------- Page: 13 ----------------------
SIST EN IEC 62311:2020
– 8 – IEC 62311:2019 © IEC 2019
[SOURCE: IEC 62226-1:2004, 3.1.7]
3.1.9
exposure level
value of the quantity used to assess exposure
Note 1 to entry: This may be an induced current density, SAR, power density, electric or magnetic field strength, a
limb current or a contact current.
3.1.10
far-field region
region of the field of an antenna where the radial field distribution is essentially dependent
inversely on the distance from the antenna
Note 1 to entry: In the far-field region the field has a predominantly plane-wave character, i.e. locally uniform
distribution of electric field and magnetic field in planes transverse to the direction of propagation. The vectors of the
electric field and the magnetic field are perpendicular to each other and the quotient between the value of the electric
field strength E and the magnetic field strength H is constant and equals the impedance of free space Z .
0
3.1.11
highest internal frequency
highest fundamental frequency generated or used within the EUT, or the highest frequency at
which it operates
3.1.12
induced current
current induced inside the body as a result of exposure to electromagnetic fields
3.1.13
inherently compliant
considered to comply with a set of requirements without the need of applying an assessment
method (such as measurements or calculations)
Note 1 to entry: A set of requirements can for example be a set of exposure limits for the general public.
Note 2 to entry: Equipment that is inherently compliant with respect to a certain set of requirements (for example
exposure limits for workers) is not necessarily inherently compliant with a different set of requirements (for example
exposure limits for the general public).
3.1.14
intentional radiator
electrical or electronic equipment in which electric, magnetic or electromagnetic fields are
intentionally generated for the purpose of radio communication, radiodetermination, treatment
of material or transfer of electromagnetic energy
3.1.15
limb current
current flowing in an arm or a leg, either as a result of a contact current or else induced by an
external field
3.1.16
magnetic field strength
H
vector quantity obtained at a given point by subtracting the magnetization M from the magnetic
flux density B divided by the magnetic constant μ
0
[SOURCE: IEC 60050-121:1998, 121-11-56, modified – The notes have been deleted.]

---------------------- Page: 14 ----------------------
SIST EN IEC 62311:2020
IEC 62311:2019 © IEC 2019 – 9 –
3.1.17
magnetic flux density
B
vector field quantity B which exerts on any charged particle having velocity v a force F equal to
the product of the vector product v x B and the electric charge Q of the particle
[SOURCE: IEC 60050-121:1998, 121-11-19, modified – The notes have been deleted.]
3.1.18
near-field region
region generally in proximity to an antenna or other radiating structure, in which the electric and
magnetic fields do not have a substantially plane-wave character, but vary considerably from
point to point
Note 1 to entry: The near-field region is further subdivided into the reactive near-field region, which is closest to
the radiating structure and that contains most or nearly all of the stored energy, and the radiating near-field region
where the radiation field predominates over the reactive field, but lacks substantial plane-wave character and is
complex in structure.
3.1.19
partial-body exposure
localized exposure of part of the body, producing a corresponding localized SAR, power density
or induced current density, as distinct from a whole-body exposure
3.1.20
plane-wave equivalent power density
power density equal in magnitude to the power density of a plane wave
having the same electric (E) or magnetic (H) field strength as the measured field
3.1.21
power density
S
power per unit area normal to the direction of
electromagnetic wave propagation
Note 1 to entry: For plane waves the power density (S), electric field strength (E) and magnetic field strength (H)
are related by the space impedance (Z ), in the case of plane wave or free space, i.e. 377 Ω:
0
2
E
2
S Z H EH
0
Z
0
2
E and H are expressed in units of V/m and A/m, respectively, and S in the unit of W/m . The value of 377 Ω is only
valid for free space, far field measurement conditions.
Note 2 to entry: Although many survey instruments indicate power density units, the actual quantities measured are
E or H or the square of those quantities.
3.1.22
reference level
level of field strength or power density derived from the basic restrictions using conservative
assumptions about exposure
Note 1 to entry: If the reference levels are met, then the basic restrictions will be complied with, but if the reference
levels are exceeded, that does not necessarily mean that the basic restrictions will not be met.
= ==

---------------------- Page: 15 ----------------------
SIST EN IEC 62311:2020
– 10 – IEC 62311:2019 © IEC 2019
3.1.23
root-mean-square value
RMS
effective value or the value associated with joule heating,
of a periodic electromagnetic wave, obtained by taking the square root of the mean of the
squared value of a function
Note 1 to entry: Although many survey instruments in the high frequency range indicate RMS, the actual quantity
measured is root-sum-square (RSS) (equivalent field strength).
3.1.24
root-sum-square value
RSS
value obtained from three individual RMS field strength values, measured in three orthogonal
directions, combined disregarding the phases
222
X XXX++
x yz
Note 1 to entry: This note applies to the French language only.
3.1.25
transient
pertaining to or designating a phenomenon or a quantity which varies between two consecutive
steady states during a time interval short compared with the timescale of interest
[SOURCE: IEC 60050-161:1990, 161-02-01]
3.1.26
whole-body exposure
exposure of the whole body (or the torso when induced current density is considered)
3.2 Abbreviated terms
CISPR Comité international spécial des perturbations radioélectriques
EIRP equivalent isotropic radiated power
EMF electromagnetic fields
EUT equipment under test
ICNIRP International Commission on Non-Ionizing Radiation Protection
IEEE Institute of Electrical and Electronics Engineers
SAR specific absorption rate
4 Compliance criteria
In general, the basic restrictions shall be used as exposure limits for the assessment of
compliance. However, in most cases reference levels are used as limits. Such reference levels
for exposure t
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.