Explosion prevention and protection in underground mines - Protective systems - Part 4: Automatic extinguishing systems for road headers

This document lays down requirements for automatic explosion extinguishing systems for roadheader machines (selective cut heading machines) in roadheader drivages where these systems automatically detect the initial phase of a firedamp explosion which has been initiated by the cutter head of a roadheader machine and extinguish it at the roadhead in such a way that the roadway drivage team is not put at risk. This document does not lay down any requirements for the fighting of fires at the roadhead.
The automatic explosion extinguishing system for roadheaders is an autonomous protective system designed in accordance with Directive 94/9/EC.

Explosionsschutz in untertägigen Bergwerken - Schutzsysteme - Teil 4: Automatische Explosionslöschanlagen für Teilschnittmaschinen

Dieses Dokument legt Anforderungen an automatische Explosionslöschanlagen für Teilschnittmaschinen (TSM) in Streckenvortrieben fest, die vom Schneidkopf einer TSM gezündete Grubengasexplosionen in der Entstehungsphase automatisch erkennen und im Vorortbereich so ablöschen, dass die Vorortbelegschaft nicht gefährdet wird.
Dieses Dokument legt keine Anforderungen für die Bekämpfung von Bränden im Vorortbereich fest.
Die automatische Explosionslöschanlage für TSM ist ein autonomes Schutzsystem gemäß Richtlinie 94/9/EG.

Protection contre l'explosion dans les mines souterraines - Systemes de protection - Partie 4: Installation d'extinction automatique d'explosion pour machines a attaque ponctuelle

Le présent document spécifie les exigences auxquelles doivent répondre les dispositifs d’extinction automatique d’explosion pour machines a attaque ponctuelle (MAP) utilisées dans le creusement de galeries souterraines, qui détectent automatiquement les explosions de grisou naissantes déclenchées par la tete d’abattage d’une MAP et les arretent sur le site, de sorte que le personnel sur site n’est pas mis en péril.
Le présent document ne spécifie aucune exigence en ce qui concerne la lutte contre les incendies dans les mines souterraines.
Le dispositif d’extinction automatique d’explosion pour MAP est un systeme de protection autonome conformément a la directive 94/9/CE.

Preprečevanje eksplozij in zaščita v podzemnih rudnikih - Zaščitni sistemi - 4. del: Avtomatske gasilne naprave za odkopne stroje

General Information

Status
Published
Publication Date
26-Jul-2007
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
10-Jul-2007
Due Date
14-Sep-2007
Completion Date
27-Jul-2007

Relations

Buy Standard

Standard
EN 14591-4:2007
English language
14 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Explosionsschutz in untertägigen Bergwerken - Schutzsysteme - Teil 4: Automatische Explosionslöschanlagen für TeilschnittmaschinenProtection contre l'explosion dans les mines souterraines - Systemes de protection - Partie 4: Installation d'extinction automatique d'explosion pour machines a attaque ponctuelleExplosion prevention and protection in underground mines - Protective systems - Part 4: Automatic extinguishing systems for road headers73.020Rudarstvo in kamnolomsko izkopavanjeMining and quarrying13.230Varstvo pred eksplozijoExplosion protection13.220.10Gašenje požaraFire-fightingICS:Ta slovenski standard je istoveten z:EN 14591-4:2007SIST EN 14591-4:2007en,fr,de01-oktober-2007SIST EN 14591-4:2007SLOVENSKI
STANDARD



SIST EN 14591-4:2007



EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 14591-4July 2007ICS 13.230; 73.100.99 English VersionExplosion prevention and protection in underground mines -Protective systems - Part 4: Automatic extinguishing systems forroad headersProtection contre l'explosion dans les mines souterraines -Systèmes de protection - Partie 4: Installation d'extinctionautomatique d'explosion pour machines à attaqueponctuelleExplosionsschutz in untertägigen Bergwerken -Schutzsysteme - Teil 4: AutomatischeExplosionslöschanlagen für TeilschnittmaschinenThis European Standard was approved by CEN on 9 June 2007.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2007 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 14591-4:2007: ESIST EN 14591-4:2007



EN 14591-4:2007 (E) 2 Contents Page Foreword.3 1 Scope.4 2 Normative references.4 3 Terms and definitions.4 4 General requirements.5 4.1 General.5 4.2 Functional requirements.5 4.2.1 General.5 4.2.2 Sensors.6 4.2.3 Extinguishing agent containers.6 4.2.4 Electronic control and discharge unit.6 4.2.5
Power supply and emergency power supply.6 4.3 Other requirements.7 5 Special requirements.7 5.1 General.7 5.2 Mechanical strength.7 5.3 Vibration and impact resistance.7 5.4 Maintenance-friendly design.8 6 Requirements for sensor systems.8 6.1 General.8 6.2 Testing and monitoring.8 6.3 Resistance to interference/electromagnetic compatibility (EMC).8 7 Requirements for signal-processing electronics.8 7.1 General.8 7.2 Triggering.8 7.3 Monitoring functions.9 7.4 Status displays.9 7.5 Resistance to interference/electromagnetic compatibility (EMC).9 8 Extinguishing system.9 8.1 General.9 8.2 Extinguishing agent containers.9 9 Marking.10 10 Information for use.10 Annex ZA (informative)
Relationship between this European Standard and the Essential Requirements of EU 94/9/EC.12 Bibliography.14
SIST EN 14591-4:2007



EN 14591-4:2007 (E) 3 Foreword This document (EN 14591-4:2007) has been prepared by Technical Committee CEN/TC 305 “Potentially explosive atmospheres - Explosion prevention and protection”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by January 2008, and conflicting national standards shall be withdrawn at the latest by January 2008. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directives. For relationship with EU Directives, see informative Annex ZA, which is an integral part of this document. This European Standard consists of the following Parts: EN 15491-1, Explosion prevention and protection in underground mines — Protective systems — Part 1:
2-bar explosion proof ventilation structures
EN 15491-2, Explosion prevention and protection in underground mines — Protective systems — Part 2: Passive water trough barriers EN 14591-4, Explosion prevention and protection in underground mines — Protective systems — Part 4: Automatic extinguishing systems for road headers According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom.
SIST EN 14591-4:2007



EN 14591-4:2007 (E) 4 1 Scope This document lays down requirements for automatic explosion extinguishing systems for roadheader machines (selective cut heading machines) in roadheader drivages where these systems automatically detect the initial phase of a firedamp explosion which has been initiated by the cutter head of a roadheader machine and extinguish it at the roadhead in such a way that the roadway drivage team is not put at risk. This document does not lay down any requirements for the fighting of fires at the roadhead. The automatic explosion extinguishing system for roadheaders is an autonomous protective system designed in accordance with Directive 94/9/EC. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 1127-2:2002, Explosive atmospheres — Explosion prevention and protection — Basic concepts
and methodology for mining EN 10025 (all Parts), Hot rolled products of structural steels EN 10204, Metallic products — Types of inspection documents EN 13237:2003, Potentially explosive atmospheres — Terms and definitions for equipment and protective systems intended for use in potentially explosive atmospheres
EN 13463-1, Non-electrical equipment for potentially explosive atmospheres — Part 1: Basic method and requirements
EN 60068-2-6, Environmental testing — Part 2: Tests — Tests Fc: Vibration (sinusoidal) (IEC
60068-2-6:1995 + Corrigendum 1995) EN 60079-0, Electrical apparatus for explosive gas atmospheres — Part 0: General
requirements (IEC 60079-0:2004, modified) EN 61000-6-2, Electromagnetic compatibility (EMC) — Part 6-2 Generic standards — Emission standard for residential, commercial and light-industrial environments (IEC 61000-6-2:2005) EN 61000-6-4, Electromagnetic compatibility (EMC) — Part 6-4: Generic standards — Emission standard for industrial environments (IEC 61000-6-4:1997, modified) EN 61508-1, Functional safety of electrical/electronic/programmable electronic safety-related systems — Part 1: General requirements (IEC 61508-1:1998 + Corrigendum 1999) 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 1127-2:2002, EN 13237:2003 and the following apply. 3.1 automatic explosion extinguishing system assembly of equipment for the automatic detection of the beginning of an explosion and initiation of the discharge of the extinguishing agent in order, in this way, to limit the destructive effects of the explosion SIST EN 14591-4:2007



EN 14591-4:2007 (E) 5
3.2 HRD extinguishing agent container device containing an explosion suppression agent that can be discharged by internal pressure
NOTE HRD is the abbreviation for High Rate Discharge 3.3 sensor
device that is triggered by changes in one or more parameters, e.g. temperature and/or radiation, caused by a developing explosion.
4 General requirements 4.1 General Automatic explosion extinguishing systems for roadheaders essentially comprise the following co-ordinated components:
sensors for explosion ignition detection; ¾ extinguishing agent containers for explosion fighting; ¾ control system for monitoring the individual components and their combined effect as well as the triggering of the extinguishing system (electronic control and operating unit); ¾ power supply and emergency power supply. The number and configuration of the individual components are determined by the type of machine and by the roadway cross-section to be protected. EN 13463-1 and EN 60079-0 shall be applied. 4.2 Functional requirements 4.2.1 General All components are to be designed for high operating reliability in accordance with the “fail-safe” principle. A high level of protection against incorrect triggering shall be ensured by means of a selective response action and minimum sensitivity to external interference factors. Appropriate protection devices are to be used to protect the components from unauthorized external interventions. If the roadheader has an automatic explosion extinguishing installation, the roadheader shall be equipped with a compulsory interlock. All electrical equipment shall be of class M1. The system is designed for an ambient temperature of – 20 °C to 40 °C. A degree of protection of at least IP 54 is required.
SIST EN 14591-4:2007



EN 14591-4:2007 (E) 6 4.2.2 Sensors Explosion-detection sensors shall operate on the basis of one of the physical quantities related to the event of an explosion (e.g. type of flame, radiation). In this respect, full use shall be made of the maximum response speed and sensitivity.
The monitoring range of the detection sensors shall be fixed in such a way that the system only detects those events that have to be controlled. The events to be detected are explosions that have been caused by the cutter head of the roadheader machine and which are initiated in the vicinity of the machine, but not fires occurring outside the cutting zone. The functional reliability of the sensors shall not be impaired by local factors (dust, water/mist, construction materials, etc.). The function of the sensors shall be proven by means of a function test with a methane flame. 4.2.3 Extinguishing agent co
...