Coaxial cables - Part 9-1: Sectional specification for coaxial cables for analogue and digital signal transmission - Indoor drop cables for systems operating at 5 MHz - 1 000 MHz

This part of the EN 50117 series which is a sectional specification applies to coaxial indoor drop cables for analogue and digital one and two way signal transmission, e.g. for cable networks for television signals, sound signals and interactive services in accordance with EN 60728 1:2014, EN 60728 1 1:2014, EN 60728 101:2017, EN 60728 10:2014, EN 50173 1:2018 and EN 50173 4:2018. This includes also the transmission of BCT signals provided by a CATV, MATV or SMATV cable network.
The purpose of this document is to specify the applicable test methods and requirements for the electrical, mechanical and environmental characteristics and for fire performance of the cables.

Koaxiale Kabel - Teil 9-1: Rahmenspezifikation für koaxiale Kabel für analoge und digitale Signalübertragung - Innenkabel für Systeme im Bereich von 5 MHz - 1 000 MHz

Câbles coaxiaux - Partie 9-1: Spécification intermédiaire pour câbles coaxiaux pour la transmission de signaux analogiques et numériques - Câbles de raccordement à usage intérieur pour les systèmes fonctionnant entre 5 MHz et 1 000 MHz

La présente partie de la série EN 50117 qui est une spécification intermédiaire s’applique aux câbles coaxiaux de raccordement à usage intérieur pour la transmission unidirectionnelle ou bidirectionnelle de signaux analogiques et numériques, par exemple pour les réseaux de distribution par câbles pour signaux de télévision, signaux de radiodiffusion sonore et services interactifs, conformément aux normes EN 60728 1:2014, EN 60728 1 1:2014, EN 60728 101:2017, EN 60728 10:2014, EN 50173 1:2018 et EN 50173 4:2018. Cela inclut également la transmission de signaux BCT (Technologies de communication et de télédiffusion) fournis par un réseau de distribution par câble (CATV, MATV ou SMATV).
Le présent document est destiné à spécifier les méthodes d’essai et les exigences applicables pour les caractéristiques électriques, mécaniques et d’environnement et pour les performances de tenue au feu des câbles.

Koaksialni kabli - 9-1. del: Področna specifikacija za koaksialne kable za analogni in digitalni prenos signala - Notranji priključni kabli za sisteme, ki delujejo v območju od 5 MHz do 1000 MHz

General Information

Status
Not Published
Public Enquiry End Date
31-Jan-2021
Technical Committee
Current Stage
4020 - Public enquire (PE) (Adopted Project)
Start Date
04-Dec-2020
Due Date
23-Apr-2021
Completion Date
01-Feb-2021

Relations

Buy Standard

Draft
prEN 50117-9-1:2021
English language
16 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
oSIST prEN 50117-9-1:2021
01-januar-2021
Koaksialni kabli - 9-1. del: Področna specifikacija za koaksialne kable za analogni
in digitalni prenos signala - Notranji priključni kabli za sisteme, ki delujejo v
območju od 5 MHz do 1000 MHz
Coaxial cables - Part 9-1: Sectional specification for coaxial cables for analogue and
digital signal transmission - Indoor drop cables for systems operating at 5 MHz - 1 000
MHz
Koaxiale Kabel - Teil 9-1: Rahmenspezifikation für koaxiale Kabel für analoge und
digitale Signalübertragung - Innenkabel für Systeme im Bereich von 5 MHz - 1 000 MHz
Câbles coaxiaux - Partie 9-1: Spécification intermédiaire pour câbles coaxiaux pour la
transmission de signaux analogiques et numériques - Câbles de raccordement à usage
intérieur pour les systèmes fonctionnant entre 5 MHz et 1 000 MHz
Ta slovenski standard je istoveten z: prEN 50117-9-1
ICS:
33.120.10 Koaksialni kabli. Valovodi Coaxial cables. Waveguides
oSIST prEN 50117-9-1:2021 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
oSIST prEN 50117-9-1:2021

---------------------- Page: 2 ----------------------
oSIST prEN 50117-9-1:2021

EUROPEAN STANDARD DRAFT
prEN 50117-9-1
NORME EUROPÉENNE

EUROPÄISCHE NORM

November 2020
ICS  Will supersede EN 50117-9-1:2019 and all of its
amendments and corrigenda (if any)
English Version
Coaxial cables - Part 9-1: Sectional specification for coaxial
cables for analogue and digital signal transmission - Indoor drop
cables for systems operating at 5 MHz - 1 000 MHz
Câbles coaxiaux - Partie 9-1: Spécification intermédiaire Koaxiale Kabel - Teil 9-1: Rahmenspezifikation für koaxiale
pour câbles coaxiaux pour la transmission de signaux Kabel für analoge und digitale Signalübertragung -
analogiques et numériques - Câbles de raccordement à Innenkabel für Systeme im Bereich von 5 MHz - 1 000 MHz
usage intérieur pour les systèmes fonctionnant entre 5 MHz
et 1 000 MHz
This draft European Standard is submitted to CENELEC members for enquiry.
Deadline for CENELEC: 2021-02-19.

It has been drawn up by CLC/SC 46XA.

If this draft becomes a European Standard, CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which
stipulate the conditions for giving this European Standard the status of a national standard without any alteration.

This draft European Standard was established by CENELEC in three official versions (English, French, German).
A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to
the CEN-CENELEC Management Centre has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.

Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are aware and to
provide supporting documentation.

Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without notice and
shall not be referred to as a European Standard.



European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2020 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Project: 69504 Ref. No. prEN 50117-9-1 E

---------------------- Page: 3 ----------------------
oSIST prEN 50117-9-1:2021
prEN 50117-9-1:2020 (E)
Contents Page
European foreword . 3
1 Scope . 4
2 Normative references . 4
3 Terms and definitions . 5
4 Requirements for cable construction, design and installation . 5
4.1 General . 5
4.2 Inner conductor . 6
4.3 Dielectric. 6
4.4 Outer conductor or screen . 6
4.5 Filling compounds . 6
4.6 Moisture barriers . 6
4.7 Wrapping layers . 6
4.8 Sheath . 6
4.9 Metallic protection . 7
4.10 Cable integral suspension strand (Messenger wire) . 7
4.11 Oversheath . 7
4.12 Fauna proofing . 7
4.13 Chemical and/or environmental proofing . 7
4.14 Cable identification . 7
4.14.1 General . 7
4.14.2 Sheath marking . 7
4.15 Labelling . 7
5 Tests and requirements for completed cables . 8
5.1 General . 8
5.2 Electrical parameters and requirements . 8
5.2.1 Low-frequency and DC electrical parameters and requirements . 8
5.2.2 High-frequency electrical and transmission parameters and requirements . 8
5.3 Mechanical parameters and requirements . 10
5.4 Environmental parameters and requirements . 11
5.5 Fire performance test methods . 12
Annex A (informative) Cable types . 13
Annex ZZ (informative) Relationship between this European standard and the safety objectives
of Directive 2014/35/EU [2014 OJ L96] aimed to be covered . 14
Bibliography . 16

2

---------------------- Page: 4 ----------------------
oSIST prEN 50117-9-1:2021
prEN 50117-9-1:2020 (E)
European foreword
This document (prEN 50117-9-1:2020) has been prepared by CLC/SC 46XA “Coaxial cables” of
CLC/TC 46X “Communication cables”.
This document is currently submitted to the Enquiry.
The following dates are proposed:
• latest date by which the existence of (doa) dor + 6 months
this document has to be announced
at national level
• latest date by which this document has to be (dop) dor + 12 months
implemented at national level by publication of
an identical national standard or by
endorsement
• latest date by which the national standards (dow) dor + 36 months
conflicting with this document have to (to be confirmed or
be withdrawn modified when voting)
This document will supersede EN 50117-9-1:2019 and all of its amendments and corrigenda (if any).
This document has been prepared under a mandate given to CENELEC by the European Commission and
the European Free Trade Association, and supports essential requirements of EU Directive(s).
For the relationship with the EU Directive 2014/35/EU see informative Annex ZZ, which is an integral part of
this document.
This document covers the Principle Elements of the Safety Objectives for Electrical Equipment Designed for
Use within Certain Voltage Limits (LVD - 2014/35/EU).
All materials used for cables according to this document are expected to fulfil the requirements of the current
REACH Regulation and ROHS Directives.
3

---------------------- Page: 5 ----------------------
oSIST prEN 50117-9-1:2021
prEN 50117-9-1:2020 (E)
1 Scope
This part of the EN 50117 series which is a sectional specification applies to coaxial indoor drop cables for
analogue and digital one and two way signal transmission, e.g. for cable networks for television signals,
sound signals and interactive services in accordance with EN 60728-1:2014, EN 60728-1-1:2014,
EN 60728-101:2017, EN 60728-10:2014, EN 50173-1:2018 and EN 50173-4:2018. This includes also the
transmission of BCT signals provided by a CATV, MATV or SMATV cable network.
The purpose of this document is to specify the applicable test methods and requirements for the electrical,
mechanical and environmental characteristics and for fire performance of the cables.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes
requirements of this document. For dated references, only the edition cited applies. For undated references,
the latest edition of the referenced document (including any amendments) applies.
EN 50117-1:2019, Coaxial cables - Part 1: Generic specification
EN 50289-3-9:2001, Communication cables - Specifications for test methods - Part 3-9: Mechanical test
methods - Bending tests
EN 50290-1-2:2004, Communication cables - Part 1-2: Definitions
EN 50290-2-1:2005, Communication cables - Part 2-1: Common design rules and construction
EN 50290-2-22:2001, Communication cables - Part 2-22: Common design rules and construction - PVC
sheathing compounds
EN 50290-2-27:2002, Communication cables - Part 2-27: Common design rules and construction - Halogen
free flame retardant thermoplastic sheathing compounds
EN 50290-2-37:2016, Communication cables - Part 2-37: Common design rules and construction -
Polyethylene insulation for coaxial cables
EN 50290-2-38:2016, Communication cables - Part 2-38: Common design rules and construction -
Polypropylene insulation for coaxial cables
EN 50290-4-1:2014, Communication cables - Part 4-1: General considerations for the use of cables -
Environmental conditions and safety aspects
EN 50290-4-2:2014, Communication cables - Part 4-2: General considerations for the use of cables - Guide
to use
EN 60728-1:2014, Cable networks for television signals, sound signals and interactive services - Part 1:
System performance of forward paths (IEC 60728-1:2014)
EN 62153-1-1:2004, Metallic communication cables test methods - Part 1-1: Electrical - Measurement of the
pulse/step return loss in the frequency domain using the Inverse Discrete Fourier Transformation (IDFT)
(IEC 62153-1-1:2003)
IEC 61196-1-112:2006, Coaxial communication cables - Part 1-112: Electrical test methods - Test for return
loss (uniformity of impedance)
IEC 61196-1-115:2006, Coaxial communication cables - Part 1-115: Electrical test methods - Test for
regularity of impedance (pulse/step function return loss)
IEC 62153-4-3:2013, Metallic communication cable test methods - Part 4-3: Electromagnetic compatibility
(EMC) - Surface transfer impedance - Triaxial method
4

---------------------- Page: 6 ----------------------
oSIST prEN 50117-9-1:2021
prEN 50117-9-1:2020 (E)
IEC 62153-4-4:2015, Metallic communication cable test methods - Part 4-4: Electromagnetic compatibility
(EMC) - Test method for measuring of the screening attenuation as up to and above 3 GHz, triaxial method
3 Terms and definitions
For the purposes of this document, the terms and definitions given in EN 50290-1-2:2004, EN 50117-1:2019,
EN 60728-1:2014 and the following apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https://www.iso.org/obp
— IEC Electropedia: available at http://www.electropedia.org/
3.1
drop cable
coaxial cable which is used to connect from:
a) subscriber tap or a directional coupler to a system outlet,
b) subscriber tap to a subscriber splitter,
c) subscriber splitter to a system outlet
3.2
indoor drop cable
drop cable for indoor application
4 Requirements for cable construction, design and installation
4.1 General
Cables according to this document are designed for an operating temperature range from −40 °C to
1)
+70 °C and at frequencies between 5 MHz and 1 000 MHz.
When designing the cable, consideration should be given to the maximum admissible current stated in the
detail specification. It is assumed that the raise of temperature of the inner conductor when submitted to the
maximum current under nominal ambient conditions does not affect the mechanical and electrical properties
of the cable.
Cables according to this document may be operated at voltages > 50 V AC or > 75 V DC according to the
detail specification of the manufacturer. However, these cables are not intended for direct connection to the
mains electricity supply or other low impedance sources.
Cables according to this document shall be designed and constructed according to EN 50290-2-1:2005,
Communication cables Part 2-1: Common design rules and construction and according to
EN 50290-4-1:2014, Communication cables - Part 4-1: General considerations for the use of cables -
Environmental conditions and safety aspects Compliance with the essential requirements of the LVD is
2
described in subclause 4.2.2 of EN 50290-4-1 .
The use of cables according to this document including delivery, storage and installation shall be in
accordance with EN 50290-4-2:2014, Communication cables - Part 4-2: General considerations for the use
of cables - Guide to use, unless otherwise specified.

1) This value is valid for applications without ampacity only, see also Table A.1 concerning max. DC current.
2) EN 50290-4-1:2014, 4.2.2 requires the use raw materials according to EN 50290-2-xx series, design
according to EN 50290-2-1 and dielectric tests according to EN 50289-1-3 and to EN 50290-2-1. Voltage
withstanding tests shall be performed between conductors and between the conductors or screen and the
outer surface of the sheath.
5

---------------------- Page: 7 ----------------------
oSIST prEN 50117-9-1:2021
prEN 50117-9-1:2020 (E)
When designed and constructed in accordance with EN 50290-2-1:2005 and EN 50117-1:2019 and
submitted to spark testing, (see 5.1.2.5 in Table 1), CATV cables according to this document may be
installed together with Low Voltage cables.
Moreover, the tests according to Clause 5 of this document shall be performed after environmental and
ageing tests. In addition, the raw materials of these cables are defined in the EN 50290 series.
This ensures sufficient stability of the cables related to this characteristic for its life cycle.
Thus these cables are considered safe when:
— they are used for their intended purpose and applications;
— they are used under voltages and currents that do not exceed the limits given in the relevant detail
specification.
All cables covered by this document do not fall under the scope of the RED or the EMC Directive.
Nevertheless, transfer impedance and screening attenuation according to 5.1.3.6 and 5.1.3.7 in Table 2 shall
be specified in the relevant detail specification, if the intended application of the cable is the use in
combination with equipment under the RED or the EMC Directive, see also EN 50290-4-1:2014, 4.2.1.
4.2 Inner conductor
The conductor shall meet the requirements of EN 50117-1:2019, 4.2 and shall be solid and may be plain or
metal coated. Dimensions shall be in accordance with the detail specification.
There shall be no joint made subsequent to the last drawing operation.
In case of metal coated conductor, consideration shall be taken for the compatibility of the connector.
4.3 Dielectric
The dielectric material(s) shall be in accordance with EN 50117-1:2019, 4.3 and shall consist of polyolefin
materials, with EN 50290-2-37:2016 (polyethylene), EN 50290-2-38:2016 (polypropylene). Dimensions shall
be in accordance with the detail specification.
Unless otherwise specified, the nominal diameter over the dielectric should be one of the preferred values,
namely 3,7 mm, 4,8 mm and 7,2 mm.
4.4 Outer conductor or screen
The construction and material of the outer conductor (or screen) shall meet the requirements of
EN 50117-1:2019, 4.4 items b), f) or g). Where option b) is used, a double braid layer is required.
For braid constructions or helically wound wires, the braid angle shall be between 15° and 45°. The coverage
factor shall be greater than or equal to 65 %, or, when the cab
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.