External fire exposure of roofs and roof coverings - Extended application of test results from CEN/TS 1187

This document gives guidance on the process and development of extended fields of application using test results obtained from CEN/TS 1187, tests 1 to 4, and included in test reports, and other relevant information in order to evaluate and classify the performance of roofs/roof coverings. This document provides a methodology to consider the possible effect(s) on classification to EN 13501-5 from single or multiple changes to the individual product and end-use application parameters of the roof/roof covering.
Specific application guidance is given in Annex A, Annex B, Annex C and Annex D for CEN/TS 1187, tests 1 to 4 respectively.

Beanspruchung von Bedachungen durch Feuer von außen - Erweiterter Anwendungsbereich der Prüfergebnisse aus CEN/TS 1187

Dieses Dokument liefert einen Leitfaden für den Prozess und die Entwicklung der erweiterten Anwendungsbereiche unter der Anwendung der in den Prüfungen 1 bis 4 nach CEN/TS 1187 erzielten und in Prüfberichten enthaltenen Prüfergebnisse und anderer einschlägiger Informationen zur Bewertung und Klassifizierung der Leistungsfähigkeit von Dächern/Bedachungen. Dieses Dokument legt eine Vorgehensweise fest, mit der die möglichen Auswirkungen einer einzelnen oder mehrfachen Änderung der einzelnen Produktparameter und Endanwendungsparameter des Daches/der Bedachung auf die Klassifizierung nach EN 13501-5 in Betracht zu ziehen sind.
In den Anhängen A, B, C und D werden spezifische Leitlinien für die Anwendung der Prüfungen 1 bis 4 nach CEN/TS 1187 gegeben.

Exposition des toitures et des couvertures à un feu extérieur - Application étendue des résultats d’essai de la CEN/TS 1187

Le présent document fournit des recommandations relatives au processus et au développement de champs d’application étendus en utilisant les résultats d’essai de la CEN/TS 1187, essais 1 à 4, et inclus dans des rapports d’essai, ainsi que d’autres informations pertinentes afin d’évaluer et de classer les performances de toitures/couvertures. Le présent document fournit une méthodologie permettant d’étudier l’effet ou les effets éventuels sur le classement selon l’EN 13501-5 de modifications simples ou multiples apportées aux produits individuels et aux paramètres d’utilisation finale de la toiture/couverture.
Des lignes directrices d’application spécifiques sont données respectivement dans l’Annexe A, l’Annexe B, l’Annexe C et l’Annexe D pour les essais 1 à 4 de la CEN/TS 1187.

Izpostavitev streh in strešnih kritin požaru z zunanje strani - Razširjena uporaba rezultatov preskusa po CEN/TS 1187

Ta dokument podaja smernice o postopku in razvoju razširjenih področij uporabe na podlagi rezultatov, pridobljenih iz preskusov CEN/TS 1187 1–4 in vključenih v poročila o preskusih, ter druge ustrezne informacije za oceno in razvrstitev zmogljivosti streh/strešnih kritin. Ta dokument podaja metodologijo za upoštevanje možnih vplivov na razvrstitev v skladu s standardom EN 13501-5 zaradi ene ali več sprememb posameznega izdelka in parametrov končne uporabe strehe/strešne kritine. Navodila za specifično uporabo so podana v dodatku A, dodatku B, dodatku C in dodatku D za CEN/TS 1187, preskusi 1–4.

General Information

Status
Published
Public Enquiry End Date
04-Sep-2019
Publication Date
10-Dec-2019
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
27-Nov-2019
Due Date
01-Feb-2020
Completion Date
11-Dec-2019

Relations

Buy Standard

Technical specification
TS CEN/TS 16459:2020
English language
103 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day
Draft
kTS FprCEN/TS 16459:2019
English language
107 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST-TS CEN/TS 16459:2020
01-januar-2020
Nadomešča:
SIST-TS CEN/TS 16459:2014
Izpostavitev streh in strešnih kritin požaru z zunanje strani - Razširjena uporaba
rezultatov preskusa po CEN/TS 1187
External fire exposure of roofs and roof coverings - Extended application of test results
from CEN/TS 1187
Beanspruchung von Bedachungen durch Feuer von außen - Erweiterter
Anwendungsbereich der Prüfergebnisse aus CEN/TS 1187
Exposition des toitures et des couvertures à un feu extérieur - Application étendue des
résultats d’essai de la CEN/TS 1187
Ta slovenski standard je istoveten z: CEN/TS 16459:2019
ICS:
13.220.50 Požarna odpornost Fire-resistance of building
gradbenih materialov in materials and elements
elementov
91.060.20 Strehe Roofs
SIST-TS CEN/TS 16459:2020 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
SIST-TS CEN/TS 16459:2020

---------------------- Page: 2 ----------------------
SIST-TS CEN/TS 16459:2020


CEN/TS 16459
TECHNICAL SPECIFICATION

SPÉCIFICATION TECHNIQUE

November 2019
TECHNISCHE SPEZIFIKATION
ICS 13.220.50; 91.060.20 Supersedes CEN/TS 16459:2013
English Version

External fire exposure of roofs and roof coverings -
Extended application of test results from CEN/TS 1187
Exposition des toitures et des couvertures à un feu Beanspruchung von Bedachungen durch Feuer von
extérieur - Application étendue des résultats d'essai de außen - Erweiterter Anwendungsbereich der
la CEN/TS 1187 Prüfergebnisse aus CEN/TS 1187
This Technical Specification (CEN/TS) was approved by CEN on 16 September 2019 for provisional application.

The period of validity of this CEN/TS is limited initially to three years. After two years the members of CEN will be requested to
submit their comments, particularly on the question whether the CEN/TS can be converted into a European Standard.

CEN members are required to announce the existence of this CEN/TS in the same way as for an EN and to make the CEN/TS
available promptly at national level in an appropriate form. It is permissible to keep conflicting national standards in force (in
parallel to the CEN/TS) until the final decision about the possible conversion of the CEN/TS into an EN is reached.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
United Kingdom.





EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2019 CEN All rights of exploitation in any form and by any means reserved Ref. No. CEN/TS 16459:2019 E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------
SIST-TS CEN/TS 16459:2020
CEN/TS 16459:2019 (E)
Contents Page
European foreword . 3
Introduction . 4
1 Scope . 6
2 Normative references . 6
3 Terms and definitions . 8
4 Product and end-use application parameters for roof coverings/roof systems . 10
5 Extended application . 11
6 Influence of product parameters and end-use application parameters on external
exposure to fire test performance . 13
7 General guidance to the annexes for application rules . 17
Annex A (normative) Application rules for test results from CEN/TS 1187, test 1, per
product group and/or components . 19
Annex B (normative) Application rules for test results from CEN/TS 1187, test 2, per
product group . 46
Annex C (normative) Application rules for test results from CEN/TS 1187, test 3, per
product group . 57
Annex D (normative) Application rules for test results from CEN/TS 1187, test 4 for
individual product groups . 78
Annex E (normative) Data acceptance principles for the submission of change request to
EXAP rules in Annex A to Annex D . 96
Bibliography . 103

2

---------------------- Page: 4 ----------------------
SIST-TS CEN/TS 16459:2020
CEN/TS 16459:2019 (E)
European foreword
This document (CEN/TS 16459:2019) has been prepared by Technical Committee CEN/TC 127 “Fire
safety in buildings”, the secretariat of which is held by BSI.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN shall not be held responsible for identifying any or all such patent rights.
This document supersedes CEN/TS 16459:2013.
CEN/TS 16459:2019 includes the following significant technical changes with respect to
CEN/TS 16459:2013:
— the Normative references have been updated;
— a new definition was added in 3.1 (term „layer“);
— the requirements to involve notified bodies in the preparation of EXAP rules was deleted from 5.4
and general;
— under clause 7, Table 5 was updated according to the insertion of new EXAP rules in different
Annexes and sections thereof, i.e. (see next lines);
— 3.5 Roof lights and roof windows: set of specific rules was moved to Annex A;
— 3.11 Liquid applied roof waterproofing kits: set of specific rules was moved to Annex A;
— the rules for the parameter „Application on existing roofs (“renovation”)“ have been reconsidered
for all Annexes and were amended and/or specified in more detail;
— Annex E „Data acceptance principles for the submission of change request to EXAP rules in Annex A
to Annex D“ is completely new: This annex sets out to establish the principles upon which data
presented to CEN TC127/WG 5 (External fire exposure of roofs and roof coverings) will be
reviewed by the committee or its nominated adhoc Sub Group for consideration.
This document has been prepared under a standardization request given to CEN by the European
Commission and the European Free Trade Association.
According to the CEN/CENELEC Internal Regulations, the national standards organisations of the
following countries are bound to announce this Technical Specification: Austria, Belgium, Bulgaria,
Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland,
Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Republic of
North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the
United Kingdom.
3

---------------------- Page: 5 ----------------------
SIST-TS CEN/TS 16459:2020
CEN/TS 16459:2019 (E)
Introduction
Fire tests on individual roofs/roof coverings are carried out in accordance with CEN/TS 1187. The
results from these tests can then be classified in accordance with EN 13501-5.
In order to derive classifications for similar roofs/roof coverings based on the data determined from
CEN/TS 1187, additional rules are needed.
These rules are direct application rules or extended application rules. Rules within the direct field of
application of test results are given in EN 13501-5 (these rules correspond to CEN/TS 1187).
This document outlines a procedure to develop rules for extended application and lists application rules
which have already been developed in Annex A to Annex D for test methods 1 to 4 from CEN/TS 1187,
where Annex A is related to test method 1, Annex B relates to test method 2, and so forth.
Annex A to Annex D have been developed based upon the available information and the roof systems in
the market. The objective of this document is to provide a methodology for optimizing the number of
tests required to cover the maximum field of application.
Annex E describes a procedure in which data acceptance principles for the submission of change
request to EXAP rules in Annex A to Annex D are set.
Whilst special attention has been focused on roofs typically comprising a support deck/substrate,
vapour barrier, insulation layer(s), membranes/roof coverings, there will be occasions when other
separating layers or intermediate layers will be needed to satisfy other roof characteristics. These
layers should be included in the consideration of the roof/the roof covering being classified.
NOTE Tests 1, 3 and 4 are carried out on a roof construction, whereas test 2 is done on a roof covering with
its substrate below, where the substrate may comprise various layers.
The decision route from the diagram below shows ways to determine which procedure to follow, when
classifying a roof/roof covering.
The solid line is compulsory, whereas the dotted line is optional.
4

---------------------- Page: 6 ----------------------
SIST-TS CEN/TS 16459:2020
CEN/TS 16459:2019 (E)

Figure 1 — Decision process on classification of roofs/roof coverings
5

---------------------- Page: 7 ----------------------
SIST-TS CEN/TS 16459:2020
CEN/TS 16459:2019 (E)
1 Scope
This document gives guidance on the process and development of extended fields of application using
test results obtained from CEN/TS 1187, tests 1 to 4, and included in test reports, and other relevant
information in order to evaluate and classify the performance of roofs/roof coverings. This document
provides a methodology to consider the possible effect(s) on classification to EN 13501-5 from single or
multiple changes to the individual product and end-use application parameters of the roof/roof
covering.
Specific application guidance is given in Annex A, Annex B, Annex C and Annex D for CEN/TS 1187,
tests 1 to 4 respectively.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
CEN/TS 1187:2012, Test methods for external fire exposure to roofs
EN 490, Concrete roofing tiles and fittings for roof covering and wall cladding — Product specifications
EN 492, Fibre-cement slates and fittings — Product specification and test methods
EN 494, Fibre-cement profiled sheets and fittings — Product specification and test methods
EN 506, Roofing products of metal sheet— Specification for self-supporting products of copper or zinc
sheet
EN 508 (all parts), Roofing products from metal sheet— Specification for self-supporting products of steel,
aluminium or stainless steel sheet
EN 534, Corrugated bitumen sheets — Product specification and test methods
EN 544, Bitumen shingles with mineral and/or synthetic reinforcements — Product specification and test
methods
EN 1013, Light transmitting single skin profiled plastics sheets for internal and external roofs, walls and
ceilings – Requirements and test methods
EN 1304, Clay roofing tiles and fittings — Product definitions and specifications
EN 1849-2, Flexible sheets for waterproofing — Determination of thickness and mass per unit area - Part
2: Plastic and rubber sheets
EN 12326-1, Slate and stone for discontinuous roofing and external cladding — art 1: Specifications for
slate and carbonate slate
EN 13162, Thermal insulation products for buildings — Factory made mineral wool (MW) products —
Specification
EN 13163, Thermal insulation products for buildings — Factory made expanded polystyrene (EPS)
products — Specification
6

---------------------- Page: 8 ----------------------
SIST-TS CEN/TS 16459:2020
CEN/TS 16459:2019 (E)
EN 13164, Thermal insulation products for buildings — Factory made extruded polystyrene foam (XPS)
products — Specification
EN 13165, Thermal insulation products for buildings — Factory made rigid polyurethane foam (PU)
products — Specification
EN 13166, Thermal insulation products for buildings — Factory made phenolic foam (PF) products —
Specification
EN 13167, Thermal insulation products for buildings — Factory made cellular glass (CG) products —
Specification
EN 13169, Thermal insulation products for buildings — Factory made expanded perlite board (EPB)
products — Specification
EN 13501-1, Fire classification of construction products and building elements — Part 1: Classification
using data from reaction to fire tests
EN 13501-5, Fire classification of construction products and building elements — Part 5: Classification
using data from external fire exposure to roofs tests
EN 13707, Flexible sheets for waterproofing — Reinforced bitumen sheets for roof waterproofing —
Definitions and characteristics
EN 13956, Flexible sheets for waterproofing — Plastic and rubber sheets for roof waterproofing —
Definitions and characteristics
EN 14351-1, Windows and doors — Product standard, performance characteristics — Part 1: Windows
and external pedestrian doorsets
EN 14509, Self-supporting double skin metal faced insulating panels — Factory made products -
Specifications
EN 14782, Self-supporting metal sheet for roofing, external cladding and internal lining — Product
specification and requirements
EN 14783, Fully supported metal sheet and strip for roofing, external cladding and internal lining —
Product specification and requirements
EN 14963, Roof coverings — Continuous rooflights of plastics with or without upstands — Classification,
requirements and test methods
ENV 1187:2002, Test methods for external fire exposure to roofs
7

---------------------- Page: 9 ----------------------
SIST-TS CEN/TS 16459:2020
CEN/TS 16459:2019 (E)
3 Terms and definitions
For the purposes of this document, the terms and definitions given in CEN/TS 1187:2012, EN 13501-5
and the following apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
• IEC Electropedia: available at http://www.electropedia.org/
• ISO Online browsing platform: available at https://www.iso.org/obp
3.1
adhesive
organic or inorganic material, e.g. polyurethane-based, bitumen-based, dispersion adhesive, glue which
is used to attach the surfaces of two or more products/components
Note 1 to entry: Adhesives or glues of the kind mentioned above could be applied separately and will thus form
a separate layer within the roof build-up, while factory pre-applied adhesives or glues are part of the specific
product/component forming a layer.
3.2
‘as tested’
term applicable for when rule does not exist for a specific parameter
3.3
binder content
amount of binding material (by % weight or % volume) within the product
Note 1 to entry: The binder could be inorganic or organic in nature. In the case of the latter, it will add a fire
load to the product containing the binder, and will be considered within the classification of products or product
groups. Within the substructure of products like mineral wool insulation products, particular felt layers, some
tiling products, and some multi-layer weather-proofing surface products the binder will typically be cured.
Note 2 to entry: The definition of this term does not apply to compound waterproofing sheets.
3.4
direct field of application of test results
outcome of a process (involving the application of defined rules) whereby a test result is deemed to be
equally valid for variations in one or more of the product properties and/or intended end use
applications
3.5
end-use application parameter
aspect of the mounting and fixing arrangement of a product reflecting/simulating its end-use
application, which can affect the fire performance
Example: type of substrate, fixing method, type and position of joints
3.6
extended field of application of test results
outcome of a process (involving the application of defined rules that can incorporate calculation
procedures) that predicts, for a variation of a product property and/or its intended end use
application(s), a test result on the basis of one or more test results to the same test standard
8

---------------------- Page: 10 ----------------------
SIST-TS CEN/TS 16459:2020
CEN/TS 16459:2019 (E)
3.7
product group
range of roof products within defined limits of variability (defined by the manufacturer or a standard)
of the product parameters and, if relevant, end-use parameters, for which the reaction of the roof in end
use application to external fire exposure remains unchanged (does not get worse)
Note 1 to entry: As far as Clause 7 is concerned, product groups also include components for Annex A.
3.8
product parameter
aspect of a product which may vary and which can have an influence on the product’s fire performance
Examples: thickness, composition, density
3.9
roof pitch
inclination of the roof surface to the horizontal
Note 1 to entry: In the case of a tiled roof, the roof pitch is the rafter pitch since the tile pitch will be a few
degrees lower due to the overlaps.
3.10
separating layer
functional layer within a roof construction that is typically used to separate layers that do not match for
reason of chemical incompatibility, or it is needed as underlay, where applicable
Note 1 to entry: Separating layers are products such as fire protective layers (e.g. glass fleece); under-slating
(e.g. polymeric sheet; polymeric sheet reinforced by polymeric fibres; bituminised reinforced sheets); and others
such as bituminous kraft paper; aluminium sheet with covering (organic); and similar.
3.11
surfacing
surface finish applied either during construction or prefabricated as part of the surfacing layer
Note 1 to entry: Surfacing can include materials such as lacquer, UV-protective coating, slate chips, ceramic-
based granules, products for factory-made lamination with glass-fleece or bituminous roofing felt, or similar.
3.12
test result
outcome of a testing process and its associated procedures detailed within a specific test standard
(which can include some processing of the results from the testing of a number of specimens)
Note 1 to entry: A test result is expressed in terms of one or more fire performance parameter(s).
3.13
type of product
products belonging to a subset of a product family (as defined in Guidance Paper G), grouping together
products having a similar nature and behaviour
Note 1 to entry: Examples of products having a similar nature include polymer modified bituminous roofing
felts, single-ply PVC membranes, cement based fibre boards, profiled metal roof sheets.
Note 2 to entry: Examples of products having a similar behaviour include products that melt or shrink under
flame attack, or decompose.
9

---------------------- Page: 11 ----------------------
SIST-TS CEN/TS 16459:2020
CEN/TS 16459:2019 (E)
3.14
factory pre-applied adhesive
factory applied adhesive
layer of organic or inorganic material e.g. polyurethane-based, bitumen-based, that is factory-applied to
products, such as to assist the installation, e.g. self-adhesion
3.15
layer
factory made product or assembly of products placed on the market
4 Product and end-use application parameters for roof coverings/roof systems
Table 1 is the list of product parameters and end-use application parameters that shall be taken into
account in Annex A to Annex D in making application rules. If other parameters are found to be relevant
for a given product, then these too should be considered in accordance with the principles of Clause 5
and Clause 6.
Annex A to Annex D list general rules and specific rules. The general rules are always valid, unless
specific rules exclude them explicitly for particular product groups and components. The general rules
are specified in A.1, A.2, B.1, B.2, C.1, C.2, D.1, and D.2.
The specific rules (A3, A4 – B3 – C3 – and D3) allow always additional extrapolations for particular
product groups and components, unless explicitly mentioned as a restriction to the general rules.
Relevant information may be contained in other documents, such as standards. This information may be
needed to define the end-use application parameters for the particular product (or product group) that
could influence the classification results in the external fire exposure tests to CEN/TS 1187, methods 1
to 4.
Table 1 — List of product parameters and end-use applications parameters
PRODUCT PARAMETERS FOR ROOF COVERINGS/ROOF SYSTEMS
Type of product
Product composition
Reaction-to-fire classification according to EN 13501-1
Colour (consider also pigments)
Binder content
Thickness
Mass per unit area
Density
Geometry (structure, shape and constitutive layers of multi-layer product)
Air gaps (perpendicular to surface)
Joints
Surfacing on lower side (backing)
Surfacing on upper side (facing)
Factory (pre-)applied adhesive
Reinforcement: mass per unit area, type of material; position within layer etc.
10

---------------------- Page: 12 ----------------------
SIST-TS CEN/TS 16459:2020
CEN/TS 16459:2019 (E)
END-USE APPLICATION PARAMETERS FOR ROOF COVERINGS/ROOF SYSTEMS
End-use parameters-general
Number of layers (details see for each product)
Order of layer in the roofing system
Orientation of each layer
End-use parameters-support
Roof pitch
Substrate or under-laying construction details
Application on existing roofs (“renovation”)
Spacing of frame elements (non-standard-support)
End-use parameters-mounting and fixing
Mounting method
Fixing method (e.g. adhesive)
Distribution, Spacing and type of mechanical fixing (fasteners)
Joints
Air gaps
5 Extended application
5.1 General principles for extended application for roof coverings/roof systems
There are three options to establish rules for extended application. These are:
— by use of additional test results which, together with the initial test result, enables consideration of
a larger range of one or several product parameters and end-use application parameters;
— by use of tests results in combination with application of calculations methods (compare with 5.3)
relating the product and end-use application parameters to the fire performance;
— by use of historical data, see 5.4, and other relevant information e.g. data from previous tests.
NOTE Extended application rules are used to develop worst case ‘build ups’. Standard ‘build ups’ are
identified in the relevant product standards taking into account worst case ‘build ups’, e.g. where no specific test
information is available, indicative testing is used to establish the worst case scenario.
5.2 Extended application by additional tests
5.2.1 Additional tests on one product/end-use application parameter
It is assumed that only one product/end-use application parameter changes and the other parameters
remain constant and that there is an initial test result on one value of the product/end-use application
parameter.
If the relationship between the fire performance and the product/end-use application parameter is
unknown, the tests will be carried out on several variants of the parameter to assess the complete range
11

---------------------- Page: 13 ----------------------
SIST-TS CEN/TS 16459:2020
CEN/TS 16459:2019 (E)
of the product/end-use application parameter on which the extended application is required and to
know this relationship.
From this relationship it will be possible to predict the different levels of fire performance as a function
of the levels of the product/end-use application parameter and therefore the level of classification.
If there is an established rule about the relationship between the product/end-use parameter and the
fire performance (direct application) of a product or product group, it will be possible to optimize the
additional tests, as a function of the classification result which is expected, as follows:
— If the fire performance of the roof is known to be affected by the change of a product/end-use
application parameter(s) in a known direction, the test can be carried out on the parameter, the
variation of which is known to give the lowest performance in this instance for this product and/or
its end use- application, without changing the classification level.
— If it is known that the fire performance changes with a change of the product/end-use application
parameter but the relationship is not known, the number of additional tests shall be sufficient to
define the relationship (sufficient means that the relationship is adequately defined over the
intended range of parameter variation). For most relationships, this will require at least two
additional test results.
When a relationship has been established between the fire performance and a product/end-use
parameter, it shall be used to determine the classification of any product or product group covered by
this relationship.
5.2.2 Additional tests on several product/end-use application parameters
When more than one roof covering product parameter or end-use application parameter is to change at
the same time, and if the types of relationship are not known, it will be necessary to assess the tests
needed according to an experimental plan or an empirical approach. Then a more detailed series of
tests shall be performed to determine the relationship between these parameters, the external fire
exposure performance, and the resultant classification.
The study of this relationship shall be carried out from direct tests according to CEN/TS 1187,
methods 1, 2, 3 or 4 and Classification to EN 13501-5.
If the types of relationship between the fire performance and the product/end use application
parameter are not known, a series of tests will be necessary. The test series can be split into parts to get
firstly a result on the type of the relationship (qualitative result) and secondly information on the
quantitative relationship, if required.
In all cases the limits of field of application shall be complied with. When a limited approach is used, it
has to be kept in mind that the resulting relationships are only valid for the particular limits of the other
parameters that were kept constant in the test.
NOTE Results from other test methods can be used to determine which product parameter needs to be tested
in European Standard methods. Reports on extended application are given in accordance with EN 15725.
5.3 Extended application by calculation
For extended application by calculation, it is necessary to have (an) established calculation method(s)
shown to be valid for the intended range of parameter(s). This requires the calculation method to be
validated in accordance with 5.2.1 or 5.2.2.
NOTE So far, there are no verified and validated published calculation methods that have been established
and agreed for use.
12

---------------------- Page: 14 ----------------------
SIST-TS CEN/TS 16459:2020
CEN/TS 16459:2019 (E)
5.4 Guidance on the use of historical test data
When undertaking extended application (EXAP) a good understanding of the product performance in
fire is required. Some of this information will be known from the EN tests according to CEN/TS 1187,
however for some products there shall exist a record of test results against previous standards.
NOTE Under certain circumstances this information can be used as part of the EXAP procedure. This will help
to reduce the number of new tests which are required.
In applying these principles, the following conditions shall be met:
— Primary data shall be obtained from the relevant CEN/TS 1187, test 1 to 4.
6 Influence of product parameters and end-use application parameters on
external exposure to fire test performance
In Clause 4 of this document, Table 1 shows the list of product and end-use application parameters that
can influence the results from external fire exposure tests to roofs.
The following is an analysis of how each of these parameters can influence the test result for each of the
four different CEN/TS 1187 test methods, assuming that all other parameters are kept unchanged.
The fire testing in different European countries has historically been based on different exposure to
burni
...

SLOVENSKI STANDARD
kSIST-TS FprCEN/TS 16459:2019
01-september-2019
Izpostavitev streh in strešnih kritin požaru z zunanje strani - Razširjena uporaba
rezultatov preskusa po CEN/TS 1187
External fire exposure of roofs and roof coverings - Extended application of test results
from CEN/TS 1187
Beanspruchung von Bedachungen durch Feuer von außen - Erweiterter
Anwendungsbereich der Prüfergebnisse aus CEN/TS 1187
Exposition des toitures et des couvertures à un feu extérieur - Application étendue des
résultats d’essai de la CEN/TS 1187
Ta slovenski standard je istoveten z: FprCEN/TS 16459
ICS:
13.220.50 Požarna odpornost Fire-resistance of building
gradbenih materialov in materials and elements
elementov
91.060.20 Strehe Roofs
kSIST-TS FprCEN/TS 16459:2019 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

kSIST-TS FprCEN/TS 16459:2019

---------------------- Page: 2 ----------------------

kSIST-TS FprCEN/TS 16459:2019


FINAL DRAFT
TECHNICAL SPECIFICATION
FprCEN/TS 16459
SPÉCIFICATION TECHNIQUE

TECHNISCHE SPEZIFIKATION

May 2019
ICS 13.220.50; 91.060.20 Will supersede CEN/TS 16459:2013
English Version

External fire exposure of roofs and roof coverings -
Extended application of test results from CEN/TS 1187
Exposition des toitures et des couvertures à un feu Beanspruchung von Bedachungen durch Feuer von
extérieur - Application étendue des résultats d'essai de außen - Erweiterter Anwendungsbereich der
la CEN/TS 1187 Prüfergebnisse aus CEN/TS 1187


This draft Technical Specification is submitted to CEN members for Vote. It has been drawn up by the Technical Committee
CEN/TC 127.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and United Kingdom.

Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.

Warning : This document is not a Technical Specification. It is distributed for review and comments. It is subject to change
without notice and shall not be referred to as a Technical Specification.


EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2019 CEN All rights of exploitation in any form and by any means reserved Ref. No. FprCEN/TS 16459:2019 E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------

kSIST-TS FprCEN/TS 16459:2019
FprCEN/TS 16459:2019 (E)
Contents Page
European foreword . 7
Introduction . 8
1 Scope . 10
2 Normative references . 10
3 Terms and definitions . 12
4 Product and end-use application parameters for roof coverings/roof systems . 14
5 Extended application . 15
5.1 General principles for extended application for roof coverings/roof systems . 15
5.2 Extended application by additional tests . 15
5.2.1 Additional tests on one product/end-use application parameter . 15
5.2.2 Additional tests on several product/end-use application parameters . 16
5.3 Extended application by calculation . 16
5.4 Guidance on the use of historical test data . 17
6 Influence of product parameters and end-use application parameters on external
exposure to fire test performance . 17
7 General guidance to the annexes for application rules . 21
Annex A (normative) Application rules for test results from CEN/TS 1187, test 1, per
product group and/or components . 23
A.1 General . 23
A.2 General rules, valid for every product within a product group and/or component. 25
A.3 Product groups . 26
A.3.1 Slates and tiles . 26
A.3.1.1 Slates and tiles, non-metallic . 26
A.3.1.2 Metallic tiles . 28
A.3.2 Small elements . 29
A.3.2.1 General . 29
A.3.2.2 Bitumen shingles . 29
A.3.2.3 Miscellaneous small elements . 31
A.3.3 Reinforced bitumen sheets . 31
A.3.4 Plastic and rubber sheets . 34
A.3.5 Rooflights and Roof windows . 37
A.3.6 Glazing systems . 37
A.3.7 Profiled non-metallic sheets . 37
A.3.7.1 Profiled fibre cement sheets . 37
A.3.7.2 Profiled bitumen based sheets . 37
A.3.7.3 Miscellaneous profiled non-metallic sheets . 37
2

---------------------- Page: 4 ----------------------

kSIST-TS FprCEN/TS 16459:2019
FprCEN/TS 16459:2019 (E)
A.3.8 Composite metallic sandwich panels . 37
A.3.9 Profiled metal sheets . 38
A.3.10 Flat metal sheets . 38
A.3.11 Reinforced liquid applied roofing waterproofing kits (LAWRK) from PU, PMMA, and
UP. 38
A.3.12 Miscellaneous . 40
A.4 Components . 40
A.4.1 Adhesive . 40
A.4.2 Separating layer . 42
A.4.3 Insulation layer . 43
A.4.4 Vapour Barrier . 46
A.4.5 Supporting deck (non-standard) . 48
Annex B (normative) Application rules for test results from CEN/TS 1187, test 2, per
product group . 50
B.1 General . 50
B.2 General rules, valid for every product within a product group . 51
B.3 Product groups . 52
B.3.1 Slates and tiles . 52
B.3.1.1 Non-metallic slates and tiles (reaction-to-fire Class A1 to A2-s3 d2 according to
EN 13501-1) . 52
B.3.1.2 Metallic tiles . 53
B.3.2 Small elements (reaction-to-fire Class B-s1, d0 to F according to EN 13501-1) . 54
B.3.2.1 General . 54
B.3.2.2 Bitumen shingles . 54
B.3.2.3 Miscellaneous small elements . 55
B.3.3 Reinforced bitumen sheets . 55
B.3.4 Plastic and rubber sheets . 57
B.3.5 Rooflights and Roof windows . 59
B.3.6 Glazing systems . 59
B.3.7 Profiled non-metallic sheets . 59
B.3.7.1 Profiled fibre cement sheets . 59
B.3.7.2 Profiled bitumen based sheets . 59
B.3.7.3 Miscellaneous profiled non-metallic sheets . 59
B.3.8 Composite metallic sandwich panels . 59
B.3.9 Profiled metal sheets . 59
B.3.10 Flat metal sheets . 59
B.3.11 Liquid applied waterproofing kits. 59
3

---------------------- Page: 5 ----------------------

kSIST-TS FprCEN/TS 16459:2019
FprCEN/TS 16459:2019 (E)
B.3.12 Miscellaneous . 60
Annex C (normative) Application rules for test results from CEN/TS 1187, test 3, per
product group . 61
C.1 General . 61
C.2 General rules, valid for every product within a product group . 63
C.3 Product groups . 64
C.3.1 Slates and tiles . 64
C.3.1.1 Non-metallic slates and tiles (reaction-to-fire Class A1 to A2 – s3 d2, according to
EN 13501-1) . 64
C.3.1.2 Metallic tiles . 66
C.3.2 Small elements (reaction-to-fire Class B – s1, d0 to F; according to EN 13501-1) . 66
C.3.2.1 General . 66
C.3.2.2 Bitumen Shingles . 66
C.3.2.3 Miscellaneous small elements . 68
C.3.3 Reinforced bitumen sheets . 68
C.3.3.1 General . 68
C.3.3.2 Typical roof waterproofing system . 68
C.3.4 Plastic and rubber sheets . 74
C.3.4.1 General . 74
C.3.4.2 Typical roof waterproofing system . 75
C.3.5 Rooflights and Roof windows . 80
C.3.6 Glazing systems . 80
C.3.7 Profiled non-metallic sheets . 80
C.3.7.1 Profiled fibre cement sheets . 80
C.3.7.2 Profiled bitumen-based sheets . 80
C.3.7.3 Miscellaneous profiled non-metallic sheets . 80
C.3.8 Composite metallic sandwich panels . 81
C.3.9 Profiled metal sheets . 81
C.3.10 Flat metal sheets . 81
C.3.11 Liquid applied roof waterproofing kits . 81
C.3.12 Miscellaneous . 81
Annex D (normative) Application rules for test results from CEN/TS 1187, test 4 for
individual product groups . 82
D.1 General . 82
D.2 General EXAP rules for CEN/TS 1187, test 4, valid for every product within a product
group . 84
D.3 Product groups . 85
4

---------------------- Page: 6 ----------------------

kSIST-TS FprCEN/TS 16459:2019
FprCEN/TS 16459:2019 (E)
D.3.1 Slates and tiles . 85
D.3.1.1 Non-metallic slates and tiles . 85
D.3.1.2 Metallic slates and tiles . 87
D.3.2 Small elements . 89
D.3.2.1 General . 89
D.3.2.2 Bitumen shingles . 89
D.3.2.3 Miscellaneous small elements, e.g. plastic tiles . 91
D.3.3 Reinforced bitumen sheets and shingles . 92
D.3.4 Plastic and rubber sheets . 95
D.3.5 Rooflights and Roof windows . 98
D.3.6 Glazing systems . 98
D.3.7 Profiled non-metallic sheets . 98
D.3.7.1 Profiled fibre cement sheets . 98
D.3.7.2 Profiled bitumen based sheets . 98
D.3.7.3 Miscellaneous profiled non-metallic sheets . 98
D.3.8 Composite (including metal faced) sandwich panels . 98
D.3.9 Profiled metal sheets . 99
D.3.10 Flat metal sheets . 99
D.3.11 Liquid applied roof water-proofing kits . 99
D.3.12 Miscellaneous . 99
Annex E (normative) Data acceptance principles for the submission of change request to
EXAP rules in Annex A to Annex D . 100
E.1 Introduction. 100
E.2 Principles . 100
E.3 Normative References . 100
E.4 Submission of Request for Changes to Annex A to Annex D . 101
E.4.1 Scope and content of proposed change. 101
E.4.1.1 General . 101
E.4.1.2 Data details . 101
E.4.1.3 Historic data . 102
E.4.2 Fire performance characteristics . 102
E.4.2.1 General . 102
E.4.2.2 Validity of test data . 103
E.4.3 Stability . 103
E.5 Protocol for review . 103
E.5.1 Review of Request for Changes to Annex A to Annex D . 103
E.5.2 Principles of review . 103
5

---------------------- Page: 7 ----------------------

kSIST-TS FprCEN/TS 16459:2019
FprCEN/TS 16459:2019 (E)
E.5.2.1 General . 103
E.5.2.2 Substitution of products and components within a roofing system based on
EN 13501-1 classifications . 104
E.5.3 Format for submission report . 104
E.6 Template for submission report . 104
E.6.1 Executive summary . 104
E.6.2 Objective . 105
E.6.3 Proposed change – Scope . 105
E.6.3.1 Current situation . 105
E.6.3.2 Proposed scope of change . 105
E.6.4 Principle for assessment . 105
E.6.4.1 Evidence . 105
E.6.5 Scope of change in relation to clauses and sections within the standard . 106
E.6.6 Impact of the change on any other clause and section within the standard . 106
E.6.7 Identification of product sectors and other CEN standards which may be impacted by
the proposed change . 106
E.6.8 Evidence supporting change: Test program . 106
E.6.8.1 Test results . 106
E.6.8.2 Analysis of the results . 106
E.6.8.3 Conclusion. 106
E.6.9 Contact details for the sponsor for the proposed change . 106
Bibliography . 107

6

---------------------- Page: 8 ----------------------

kSIST-TS FprCEN/TS 16459:2019
FprCEN/TS 16459:2019 (E)
European foreword
This document (FprCEN/TS 16459:2019) has been prepared by Technical Committee CEN/TC 127 “Fire
safety in buildings”, the secretariat of which is held by BSI.
This document is currently submitted to the Vote on TS.
This document has been prepared under a standardization request given to CEN by the European
Commission and the European Free Trade Association.
7

---------------------- Page: 9 ----------------------

kSIST-TS FprCEN/TS 16459:2019
FprCEN/TS 16459:2019 (E)
Introduction
Fire tests on individual roofs/roof coverings are carried out in accordance with CEN/TS 1187. The
results from these tests ca
...

Questions, Comments and Discussion