This document specifies the quality assurance and quality control procedures related to automated dust arrestment plant monitors.
This document applies to two types of instruments commonly used for dust arrestment plant control purposes:
-   filter dust monitors that are configured in mass concentration units (e.g. mg/m3) and are used for dust arrestment control purposes;
-   filter leakage monitors that indicate a change in the emission levels or a change in the magnitude of the dust pulses created by the cleaning process of the dust arrestment plant.
This document applies to instruments certified according to the requirements of EN 15859.
This document provides information on the configuration, ongoing quality assurance (with automatic internal zero point and reference point checks) and annual surveillance tests of instruments. This ensures that the instrument is providing information to demonstrate that the dust arrestment plant is working correctly and controlling dust pollution to the required levels.
The configuration of the alarm levels of filter dust monitors is performed by parallel measurements with the standard reference method in EN 13284 1.
This document specifies the set-up of filter leakage monitors used to monitor a change in response caused by deterioration in the operation of the dust arrestment plant.

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the standard reference method (SRM) for the measurement of low dust concentration in ducted gaseous streams in the concentrations below 50 mg/m3 at standard conditions.
This European Standard is primarily developed and validated for gaseous streams emitted by waste incinerators. More generally, it can be applied to gases emitted from other stationary sources, and to higher concentrations.
If the gases contain unstable, reactive or semi-volatile substances, the measurement depends on the sampling and filter treatment conditions.
This method has been validated in field tests with special emphasis to dust concentrations around 5 mg/m3. The results of the field tests are presented in Annex A.

  • Standard
    63 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies requirements for the calibration and validation (QAL2), the ongoing quality assurance during operation (QAL3) and the annual surveillance test (AST) of automated measuring systems (AMS) used for monitoring dust emissions from stationary sources to demonstrate compliance with emission limit values (ELV) below 50 mg/m3 at standard conditions. It specifically deals with measurements in wet gases and at low concentrations.
This document is derived from EN 14181 and is only applicable in conjunction with EN 14181.
This document is applicable by direct correlation with the standard reference method (SRM) described in EN 13284-1.

  • Standard
    33 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This Part of EN 13284 specifies specific requirements on automated measuring systems (AMS) for dust monitoring. It is derived from EN 14181 which is the general document on the quality assurance of AMS. It is only applicable in conjunction with EN 14181.
This part of EN 13284 specifies test criteria for the QAL1 and specific requirements for QAL2, QAL3 and AST for dust AMS used for proving that the dust emissions from a source are compliant with emission limits below 50 mg/m3 (standard conditions) in ducted gaseous streams. This part of EN 13284 is applicable by direct correlation with the standard reference method (SRM) described in EN 13284-1.
This part of EN 13284 is primarily developed for emissions from waste incinerators. From a technical point of view, it may be applied to other processes, for which measurement at an emission limit is required with defined uncertainty.

  • Standard
    25 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies a reference method for the measurement of low dust concentration in ducted gaseous streams in the concentrations below 50 mg/m3 standard conditions. This method has been validated with special emphasis around 5 mg/m3 on an average half hour sampling time.
This European Standard is primarily developed and validated for gaseous streams emitted by waste incinerators. More generally, it may be applied to gases emitted from stationary sources, and to higher concentrations.
If the gases contain unstable, reactive or semi-volatile substances, the measurement depend on the sampling and filter treatment conditions.

  • Standard