IEC 62932-2-2:2020 applies to flow battery systems for stationary applications and their installations with a maximum voltage not exceeding 1 500 V DC in compliance with IEC 62932-1. This document defines the requirements and test methods for risk reduction and protection measures against significant hazards relevant to flow battery systems, to persons, property and the environment, or to a combination of them. This document is applicable to stationary flow battery systems intended for indoor and outdoor commercial and industrial use in non-hazardous (unclassified) areas. This document covers significant hazards, hazardous situations and events, with the exception of those associated with natural disaster, relevant to flow battery systems, when they are used as intended and under the conditions foreseen by the manufacturer including reasonably foreseeable misuse thereof. The requirements described in this document are not intended to constrain innovations. When considering fluids, materials, designs or constructions not specifically dealt with in this document, these alternatives are evaluated as to their ability to yield levels of safety equivalent to those specified in this document.

  • Standard
    33 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62932-1:2020 relates to flow battery energy systems (FBES) used in electrical energy storage (EES) applications and provides the main terminology and general aspects of this technology, including terms necessary for the definition of unit parameters, test methods, safety and environmental issues.

  • Standard
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

NEXT ACTION: PART OF A PACKAGE
2018-10-01: Positive assessment from NAC received on 2018-10-01. BT doc prepared and to be submitted to 4 weeks consultation
2018-09-14 CV: Positive assessment expected (info from NAC) but not yet uploaded on HAS Livelink folder -- BT doc for publication awaiting official assessment
2018-09-06 CV: New request for assessment sent on 2018-08-12 -- EN 60335-2-6:2015/FprA1 (PR=63514) and EN 60335-2-6:2015/FprAA (PR=62259) have been voted upon without Annex ZZ. The projects could not proceed. CLC/TC 61 worked on the Annex ZZ which, if positively assessed by the LVD consultant will be added to EN 60335-2-6:2015/FprAA (PR=62259).
If both positively assessed, EN 60335-2-6:2015/FprA1 (PR=63514) and EN 60335-2-6:2015/FprAA (PR=62259) will be published on the same date.
2018-06-25: Consultant's assessment is missing at CDV stage.

  • Amendment
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62932-2-1:2020 specifies methods of test and requirements for the flow battery system (FBS) and the flow battery energy system (FBES) for the verification of their performances. This document is applicable to FBES or FBS which are designed and used for service in stationary locations (i.e. not generally to be moved from place to place). This document does not cover testing of the system for electromagnetic compatibility (EMC).

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61854:2020 is available as IEC 61854:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61854:2020 applies to spacers for conductor bundles of overhead lines. It covers rigid spacers, flexible spacers and spacer dampers. It does not apply to interphase spacers, hoop spacers and bonding spacers. This document is written to cover the line design practices and spacers most commonly used at the time of writing. There may be other spacers available for which the specific tests reported in this document may not be applicable. In some cases, test procedures and test values are left to agreement between purchaser and supplier and are stated in the procurement contract. The purchaser is best able to evaluate the intended service conditions, which should be the basis for establishing the test severity. In Annex A, the minimum technical details to be agreed between purchaser and supplier are listed. This second edition cancels and replaces the first edition published in 1998. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) Consider the application of spacers on high temperature conductors specifying additional high temperature tests in clamp slip tests and for the characterization of elastic and damping properties; b) Specify as far as possible test parameters and acceptance values; c) Avoid as far as possible the alternative procedures for the same test; d) Introduce a simpler test device for the simulated short circuit current test; e) Introduce test at low temperature on fastener components such as break away bolts and conical spring washers; f) Prescribe a different procedure for subspan oscillation tests on spacers equipped with clamps having rod attachments; g) Modify the test procedure for the aeolian vibration tests; h) Prescribe a different procedure for aeolian vibration tests on spacers equipped with clamps having rod attachments; i) Re-edit all the figures in order to make them more clear and homogeneous; j) Introduce an additional test device for the simulated short circuit current test. Key words: Overhead Lines, Spacers

  • Standard
    51 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62282-8-101:2020 addresses solid oxide cell (SOC) and stack assembly unit(s). It provides for testing systems, instruments and measuring methods to test the performance of SOC cell/stack assembly units for energy storage purposes. It assesses performance in fuel cell mode, in electrolysis mode and/or in reversible operation. This document is intended for data exchanges in commercial transactions between cell/stack manufacturers and system developers or for acquiring data on a cell or stack in order to estimate the performance of a system based on it. Users of this document may selectively execute test items suitable for their purposes from those described in this document. Users can also substitute selected test methods of this document with equivalent test methods of IEC TS 62282-7-2 for SOC operation in fuel cell mode only.

  • Standard
    83 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61897:2020 is available as IEC 61897:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 61897:2020 applies to aeolian vibration dampers intended for single conductors or earth wires or conductor bundles where dampers are directly attached to each subconductor. The purchaser may adopt part(s) of this document when specifying requirements for cables different from those mentioned above (e.g. optical ground wires (OPGW), all dielectric self-supporting optical cables (ADSS)). In some cases, test procedures and test values are left to agreement between the purchaser and the supplier and are stated in the procurement contract. Annex A lists the minimum technical details to be agreed between purchaser and supplier. Throughout this document, the word “conductor” is used when the test applies to dampers for conductors or earth wires. This second edition cancels and replaces the first edition published in 1998. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) Consider, in addition to Stockbridge type aeolian vibration dampers, also spiral aeolian vibration dampers and elastomeric aeolian vibration dampers. b) Consider the application of dampers on high temperature conductors, specifying additional high temperature tests in clamp slip tests. c) Simplify the procedure of the damper effectiveness evaluation. d) Introduce test at low temperature on fastener components such as break away bolts and conical spring washers. e) Include figures showing the test arrangements for the main mechanical tests. Key words: Overhead Lines, Aeolian Vibration Dampers

  • Standard
    32 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62435-3:2020 describes the aspects of data storage that are necessary for successful use of electronic components being stored after long periods while maintaining traceability or chain of custody. It defines what sort of data needs to be stored alongside the components or dies and the best way to do so in order to avoid losing data during the storage period. As defined in this document, long-term storage refers to a duration that can be more than twelve months for products scheduled for long duration storage. Philosophy, good working practice, and general means to facilitate the successful long-term-storage of electronic components are also addressed. NOTE: In IEC 62435 (all parts), the term "components" is used interchangeably with dice, wafers, passives and packaged devices.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62282-3-100:2019 is available as IEC 62282-3-100:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 62282-3-100:2019 applies to stationary packaged, self-contained fuel cell power systems or fuel cell power systems comprised of factory matched packages of integrated systems which generate electricity through electrochemical reactions. This document is applicable to stationary fuel cell power systems intended for indoor and outdoor commercial, industrial and residential use in non-hazardous areas. This second edition cancels and replaces the first edition published in 2012. This edition includes the following significant technical changes with respect to the previous edition: a) recognition that fuel carrying components qualified to leakage standards (soundness) need not be considered as potential flammable leak sources; b) new annex for small power systems; and c) clarifications for numerous requirements and tests

  • Standard
    87 pages
    English language
    sale 10% off
    e-Library read for
    1 day

TAN - // IEC Corrigendum

  • Corrigendum
    4 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies a data model to abstract the metering world towards a simple external. The data model, as described by means of functional blocks contained in this European Standard, lays down the format of metering data

  • Amendment
    42 pages
    English language
    sale 10% off
    e-Library read for
    1 day

TAN - // IEC Corrigendum

  • Corrigendum
    3 pages
    English and French language
    sale 10% off
    e-Library read for
    1 day

IEC 61293:2019 establishes minimum requirements and general rules on marking electric equipment with ratings and other characteristics to enable the proper and safe selection and installation of electric equipment related to any supply of electricity. The object of this document is to: • provide general requirements for the marking of the characteristics related to any supply system, such as voltage, current, frequency and power, without any restrictions; • provide technical committees with uniform methods for the marking of electrical ratings of products. This document is primarily intended for application by technical committees when specifying minimum markings of ratings related to any electrical supply of equipment, sub-assemblies and components, but it is also for application by product manufacturers for marking their products. This horizontal standard is primarily intended for use by technical committees in the preparation of standards in accordance with the principles laid down in IEC Guide 108. One of the responsibilities of a technical committee is, wherever applicable, to make use of horizontal standards in the preparation of its publications. The contents of this horizontal standard will not apply unless specifically referred to or included in the relevant publications. IEC 61293:2019 cancels and replaces the first edition published in 1994. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) its status as a basic safety publication has been removed, and it has become a horizontal publication in accordance with IEC Guide 108; b) the scope is extended to include the applicability of this document to product manufacturers; c) the addition of a provision that the visibility of the marking during normal operation should be considered; d) more detailed requirements where equipment has a set or range of rated values for a given characteristic; e) requirements regarding the provision of the markings also in the technical documentation have been added; f) some notes have been converted to normative text; g) normative references and references to other standards have been updated.

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard defines the mandatory and optional requirements for the medium specific physical and data link layer for HBES Class 1 Twisted Pair TP1. Data link layer interface and general definitions, which are media independent, are given in EN 50090 4 2.

  • Standard
    48 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60601-2-31:2020 is available as IEC 60601-2-31:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 60601-2-31:2020 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of EXTERNAL PACEMAKERS powered by an INTERNAL ELECTRICAL POWER SOURCE, hereafter referred to as ME EQUIPMENT. This document applies to PATIENT CABLES as defined in 201.3.209, but does not apply to LEADS as defined in 201.3.206. HAZARDS inherent in the intended physiological function of ME EQUIPMENT within the scope of this document are not covered by specific requirements in this document except in 7.2.13 and 8.4.1 of the general standard. This document does not apply to the implantable parts of ACTIVE IMPLANTABLE MEDICAL DEVICES covered by ISO 14708-1. This document does not apply to EXTERNAL PACEMAKERS which can be connected directly or indirectly to a SUPPLY MAINS. This document does not apply to transthoracic and oesophageal pacing ME EQUIPMENT and antitachycardia ME EQUIPMENT. IEC 60601-2-31:2020 cancels and replaces the second edition published in 2008 and Amendment 1:2011. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) The requirement for testing for energy reduction has been removed; b) The test for exposure to external defibrillation has been completely revised; c) The exclusion for testing ESD immunity only with respect to air discharges has been removed; d) Alignment with the latest edition of ISO 14708-2 for pacemakers, as well as the associated EMC standard ISO 14117; e) Additional rationale for all changes.

  • Standard
    57 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document applies to overhead contact line systems in heavy railways, light railways, trolley buses and industrial railways of public and private operators. This document applies to new installations of overhead contact line systems and for the complete renewal of existing overhead contact line systems. This document contains the requirements and tests for the design of overhead contact lines, requirements for structures and their structural calculations and verifications as well as the requirements and tests for the design of assemblies and individual parts. This document does not provide requirements for ground level conductor rail systems (see Figure 1).

  • Standard
    108 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61223-3-6:2020 applies to the performance of MAMMOGRAPHIC X-RAY EQUIPMENT when used in MAMMOGRAPHIC TOMOSYNTHESIS modes of operation, with respect to image quality and dose. Excluded from the scope of this document are: - MAMMOGRAPHIC X-RAY EQUIPMENT modes of operation other than MAMMOGRAPHIC TOMOSYNTHESIS; - 2D images synthesised from the tomosynthesis images; - reconstructive TOMOGRAPHY other than MAMMOGRAPHIC TOMOSYNTHESIS; - CT SCANNERS covered by IEC 61223-3-5. IEC 61223-3-6:2020 defines a) the essential parameters which describe the acceptability criteria of MAMMOGRAPHIC TOMOSYNTHESIS modes of operation of MAMMOGRAPHIC X-RAY EQUIPMENT with regard to image quality and dose, b) the methods of testing whether measured quantities related to those parameters comply with specified tolerances, and c) CONSTANCY TEST frequency when required. This document is intended to be applied along with the acceptability criteria included in IEC 61223-3-2 or equivalent protocol for 2D mammography which are also relevant for MAMMOGRAPHIC TOMOSYNTHESIS modes of operation. These methods mainly rely on non-invasive measurements that use appropriate test equipment and are performed during or after the installation. Signed statements covering steps in the installation procedure can be used as part of the ACCEPTANCE TEST. Tests required by a higher level of compliance take precedence over similar tests with a lower level of compliance. When the results of the ACCEPTANCE TEST are in compliance with the expected values, the BASELINE VALUES for the subsequent CONSTANCY TESTS are established.

  • Standard
    56 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60601-2-66:2019 is available as IEC 60601-2-66:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60601-2-66:2019 applies to the BASIC SAFETY of HEARING AIDS and HEARING AID SYSTEMS, hereafter also referred to as ME EQUIPMENT or ME SYSTEM. IEC 60601-2-66:2019 cancels and replaces the second edition published in 2015. It constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) revision of the definition about ESSENTIAL PERFORMANCE; b) revision of the application of IEC 60601-1-2:2014 for electromagnetic disturbances; c) correction of the used voltage for HEARING AIDS from 1,6 V to 4,5 V; d) correction of the drop test level from 1,5 m to 1,0 m; e) correction of the wording of IEC 60601-2-66:2015.

  • Standard
    64 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 80601-2-78:2019 applies to the general requirements for BASIC SAFETY and ESSENTIAL PERFORMANCE of MEDICAL ROBOTS that physically interact with a PATIENT with an IMPAIRMENT to support or perform REHABILITATION, ASSESSMENT, COMPENSATION or ALLEVIATION related to the PATIENT’S MOVEMENT FUNCTIONS, as intended by the MANUFACTURER. IEC 80601-2-78:2019 does not apply to • external limb prosthetic devices (use ISO 22523), • electric wheelchairs (use ISO 7176 (all parts)), • diagnostic imaging equipment (e.g. MRI, use IEC 60601-2-33), and • personal care ROBOTS (use ISO 13482).

  • Standard
    79 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2020-03-17-JO- BT decision BT164/DG11529/DV to remove the link to the MDD (93/42/EEC)
Publication on hold due to negative assessment

  • Amendment
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60704-2-4:2011 These particular requirements apply to single unit electrical washing machines and the washing and spinning function of combined appliances for household and similar use and to spin extractors for household and similar use. This third edition cancels and replaces the second edition (2001). Main changes are: - measurement uncertainty and standard deviations are taken into account, - definitions of standard test load and standard test program are modified, - test enclosure was replaced by common test enclosure defined in Part 1 and - information to be reported is modified. This publication is to be read in conjunction with  IEC 60704-1:2010.

  • Amendment
    3 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    3 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2019-12-24: decision to skip FV taken by TC - mail from TC 2019-12-23

  • Amendment
    4 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    4 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60086-6:2020 applies to all chemistries of portable primary cells and batteries standardized in the 60086 series. The purpose of this document is to provide guidance on the proper scientific protocols for testing the environmental performance of batteries; the symbols used to convey messages for collection, recycling, or other ideas; and the aspects and functional unit(s) to be included in assessing the environmental impact of batteries with modern life-cycle analysis techniques

  • Standard
    36 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 80601-2-26:2019 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of ELECTROENCEPHALOGRAPHS as defined in 201.3.204, hereafter also referred to as ME EQUIPMENT or ME SYSTEM. This document is applicable to ELECTROENCEPHALOGRAPHS intended for use in professional healthcare facilities, the EMERGENCY MEDICAL SERVICES ENVIRONMENT or the HOME HEALTHCARE ENVIRONMENT. This document does not cover requirements for other equipment used in electroencephalography such as: – phono-photic stimulators; – EEG data storage and retrieval; – ME EQUIPMENT particularly intended for monitoring during electro-convulsive therapy. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title or content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as follows. The clause or subclause applies to ME EQUIPMENT, as default. For ME EQUIPMENT with the corresponding safety measure or function not completely integrated into the ME EQUIPMENT but instead implemented in an ME SYSTEM, the ME EQUIPMENT MANUFACTURER specifies in the ACCOMPANYING DOCUMENTS which functionality and safety requirements are provided by the ME SYSTEM to comply with this document. The ME SYSTEM is verified accordingly. HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this document are not covered by specific requirements in this document. IEC 80601-2-26:2019 cancels and replaces the third edition of IEC 60601-2-26 published in 2012. This edition constitutes a technical revision to align with Amendment 1:2012 of IEC 60601-1:2005, new versions of collateral standards and amendments thereto.

  • Standard
    39 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the Cooling Efficiency Ratio (CER) as a Key Performance Indicator (KPI) to quantify the efficient use of energy to control the temperature of the spaces within the data centre. This document: a) defines the Cooling Efficiency Ratio (CER) of a data centre; b) describes the relationship of this KPI to a data centre’s infrastructure, information technology equipment and information technology operations; c) defines the measurement, the calculation and the reporting of the parameter; d) provides information on the correct interpretation of the CER. Annex A describes the correlation of CER and other KPIs. Annex B provides examples of the application of CER. Annex C introduces the parameters that affect CER. Annex D describes requirements and recommendations for derivatives of KPIs associated with CER.

  • Standard
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 80601-2-60:2019 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE OF DENTAL UNITS, DENTAL PATIENT CHAIRS, DENTAL HANDPIECES AND DENTAL OPERATING LIGHTS, hereafter referred to as DENTAL EQUIPMENT. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant. HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this document are not covered by specific requirements in this document except in 7.2.13 and 8.4.1 of the general standard. IEC 80601-2-60:2019 cancels and replaces the first edition published in 2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) alignment with IEC 60601-1:2005 and IEC 60601-1:2005/AMD1:2012.

  • Standard
    45 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60580:2019 is available as IEC 60580:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60580:2019 specifies the performance and testing of Dose Area Product Meters intended to measure Dose Area Product and/or Dose Area Product Rate to which the Patient is exposed during Medical Radiological Examinations. This document is applicable to the following types of Dose Area Product Meters: a) Field-Class Dose Area Product Meters normally used for the measurement of Dose Area Products during Medical Radiological Examinations; b) Reference-Class Dose Area Product Meters normally used for the Calibration of Field-Class Dosimeters. NOTE Reference-Class Dose Area Product Meters can be used as Field-Class Dose Area Product Meters. The object of this document is 1) to establish requirements for a satisfactory level of performance for Dose Area Product Meters, and 2) to standardize the methods for the determination of compliance with this level of performance. Two levels of performance are specified: – a lower level of performance applying to Field-Class Dose Area Product Meters; – a higher level of performance applying to Reference-Class Dose Area Product Meters. IEC 60580:2019 cancels and replaces the second edition published 2000, and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) a second class of devices is introduced with tighter uncertainty tolerances; b) this document has been expanded to include detectors other than ionization chambers; c) radiation qualities have been updated to the new definitions according to IEC 61267; d) a requirement on the linearity of the dose area product rate measurement was added; e) changed chamber light transmission requirement from 70 % to 60 %.

  • Standard
    38 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60601-2-83:2019 is applicable to the BASIC SAFETY and ESSENTIAL PERFORMANCE of HOME LIGHT THERAPY EQUIPMENT, intended for use in the HOME HEALTHCARE ENVIRONMENT. HOME LIGHT THERAPY EQUIPMENT is typically used by a LAY OPERATOR. The scope of this document includes all light sources except laser.

  • Standard
    34 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2020-01-08 CV: BT decision (D164/C119) to proceed to publication without link to legislation
2019-11-07 mah: consultant assessment missing: blocked.
2019-11-12 - JO: BT document to remove link to the MDD under review

  • Amendment
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Transfer of the IEC/IEEE 82079-1 (replacement of IEC 82079-1:2012) to an equivalent EN (replacement of EN 82079-1:2012).

  • Standard
    66 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60118-13:2019 covers the relevant EMC phenomena for hearing aids. Hearing aid immunity to high frequency fields originating from digital wireless devices such as mobile phones was identified as one of the most relevant EMC phenomena impacting hearing aids. IEC 60118-13:2019 cancels and replaces the fourth edition published in 2016 and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) it introduces a new measurement method and set of EMC requirements for hearing aids immunity to mobile digital wireless devices; b) generic EMC requirements for hearing aids are no longer included – should be covered by other standards as appropriate.

  • Standard
    25 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60947-5-2:2019 applies to inductive and capacitive proximity switches that sense the presence of metallic and/or non-metallic objects, ultrasonic proximity switches that sense the presence of sound reflecting objects, photoelectric proximity switches that sense the presence of objects and non-mechanical magnetic proximity switches that sense the presence of objects with a magnetic field. This fourth edition cancels and replaces the third edition published in 2007 and Amendment 1:2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:  update of the scope; adaptation and update of the construction requirements according to IEC Guide 116 (e.g. material requirements, artificial optical radiation, instruction requirements, hot surface, unattended operation, foreseeable misuse…); modification of the specifications concerning the sensing range and operating distance; new definitions for photoelectric proximity switch type D with background suppression; integration of the requirements and test procedures of photoelectric proximity switch type D with background suppression; update of EMC requirements in Table 9 and Table 10; integration of environmental information requirements and environmental condition by referencing Annexes O, W and Q of IEC 60947-1:2007, IEC 60947-1:2007/AMD1:2010 and IEC 60947-1:2007/AMD2:2014; modification of impulse withstand voltage test (5.3.1.3, 9.3.3.4.5); modification of the references in the (normative) standard body to the (informative) Annex A; major update of Annex A (definitions update, new dimensions and shapes); update of C.9.1.1; update of Annex D in order to consider new connector types and normative references; update of Annex F (additional symbols for photoelectric proximity switches).

  • Standard
    137 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 63115-1:2020 specifies the marking, designation, tests and requirements for sealed nickel­metal hydride cells and batteries used in industrial applications, including stationary applications. When an IEC International Standard specifying test conditions and requirements for cells used in special applications is in conflict with this document, the former takes precedence (e.g. IEC 62675). The following are some examples of applications that utilize the cells and batteries falling under the scope of this document. • Stationary applications: telecom, uninterruptible power supplies (UPS), electrical energy storage system, utility switching, emergency power and similar applications. • Motive applications: fork-lift truck, golf cart, AGV (Automatic Guided Vehicle), railway, and marine, excluding road vehicles. Since this document covers batteries for various industrial applications, it includes those requirements that are common and minimum to the various applications. This document applies to cells and batteries. If the battery is divided into smaller units, the smaller unit can be tested as representative of the battery. The manufacturer clearly declares the tested unit. The manufacturer can add functions to the tested unit that are present in the final battery.

  • Standard
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60704-2-7:2020 is available as IEC 60704-2-7:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 60704-2-7:2020 applies to electrical fans (including their accessories and their component parts) for household and similar use, designed for AC or DC supply. The motor, the impeller and their housing, if any, form a single unit. These particular requirements apply to: – conventional fans, – table fans, – pedestal fans, – ceiling fans, – bladeless fans, – wall bracket fans, – ceiling bracket fans, – louver fans, – tower fans, – ventilating and partition ventilating fans. This standard does not apply to: – fans that are part of a ventilation system, – fans designed exclusively for industrial purposes, – fans that are part of an appliance (for example cooling fans), – fans with additional functions (for example heating, humidifying). Limitations for the use of this test code are given in the scope of IEC 60704-1. This second edition cancels and replaces the first edition published in 1997. This edition constitutes a technical revision. This edition includes the following significant changes with respect to the previous edition: a) it includes additional fan categories as defined in IEC 60879:2019 and IEC 60665:2018; b) it includes standard deviations of sound power levels in 1.3; c) a comparison method has been added; d) the normative references have been updated (ISO 3744:2010 and ISO 3743-1:2010); e) it has been adjusted with regard to IEC 60704-1:2010. This International Standard is to be used in conjunction with IEC 60704 1:2010, Household and similar electrical appliances – Test code for the determination of airborne acoustical noise – Part 1: General requirements. This Part 2-7 supplements or modifies the corresponding clauses in IEC 60704-1:2010, so as to establish the test code for fans.

  • Standard
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62368-3:2017 applies to equipment intended to supply and receive operating power through communication cables or ports. It covers particular requirements for circuits that are designed to transfer DC power from a power sourcing equipment (PSE) to a powered device (PD). The power transfer uses voltages at ES1 or ES2 or in very specific cases voltage levels at ES3. Any cable provided with a connector defined by an industry standard that permits DC power transfer between equipment is considered a communication cable even if communication does not take place. For example, a USB cable can be used just to recharge a portable device battery. This International Standard is to be used in conjunction with IEC 62368-1:2014. It has the status of a group safety publication in accordance with IEC Guide 104. The subclauses of IEC 62368-1 apply as far as reasonable. Where safety aspects are similar to those of IEC 62368-1, the relevant clause or subclause of IEC 62368-1 is given for reference in a note in the relevant subclause. Where a requirement in IEC 62368-3 refers to a requirement or criterion of IEC 62368-1, a specific reference to IEC 62368-1 is made. This group safety publication is primarily intended to be used as a product safety standard for the products mentioned in the scope, but shall also be used by technical committees in the preparation of standards for products similar to those mentioned in the scope of this standard, in accordance with the principles laid down in IEC Guide 104 and lSO/lEC Guide 51. Keywords: Communication, Safety, Cables, DC Power Transfer,

  • Standard
    28 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60436:2015 applies to electric dishwashers for household and similar use that are supplied with hot and/or cold water. The object is to state and define the principal performance characteristics of electric dishwashers for household and similar use and to describe the standard methods of measuring these characteristics. This standard is concerned neither with safety nor with minimum performance requirements. This edition constitutes a technical revision and includes the following significant technical changes with respect to the previous edition: a) Addition of a specification of the reference dishwasher G1222, addition of the microwave oven 752C, inclusion of standby/low power modes and updated cutlery and tableware items. b) Combined cleaning and drying: combining the cleaning and drying performance evaluations into one test, along with the energy and water consumption evaluation, prevents an opportunity for circumvention if tests were performed separately. A dishwasher can detect whether soil is present (cleaning evaluation) or not (drying evaluation) and adjust the cycle to favour performance; combining the tests addresses this. c) New dish load items: new dish load items were incorporated which reflect consumer use. New items are: stainless pots, coffee mugs, melamine plastic items, and glass bowl. The new load items provide different shapes which challenge a dishwasher water spray patterns and provide additional surfaces for soil removal assessment. d) Detergent: a new detergent "D" is specified which mirrors current tablet formulations available on the market. Detergent type D is phosphate free, with percarbonate instead of perborate bleach and more active enzymes. e) Repeatability and reproducibility improvements. f) Addition of annexes for the evaluation of soil sensing programmes, rinsing performance, dishwasher filtration and of an annex on the inlet water temperature influence on energy consumption.

  • Standard
    159 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61000-4-11:2020 is available as IEC 61000-4-11:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61000-4-11:2020 defines the immunity test methods and range of preferred test levels for electrical and electronic equipment connected to low-voltage power supply networks for voltage dips, short interruptions, and voltage variations. This document applies to electrical and electronic equipment having a rated input current not exceeding 16 A per phase, for connection to 50 Hz or 60 Hz AC networks. It does not apply to electrical and electronic equipment for connection to 400 Hz AC networks. Tests for these networks will be covered by future IEC documents. The object of this document is to establish a common reference for evaluating the immunity of electrical and electronic equipment when subjected to voltage dips, short interruptions and voltage variations. NOTE 1 Voltage fluctuation immunity tests are covered by IEC 61000-4-14. The test method documented in this document describes a consistent method to assess the immunity of equipment or a system against a defined phenomenon. NOTE 2 As described in IEC Guide 107, this is a basic EMC publication for use by product committees of the IEC. As also stated in Guide 107, the IEC product committees are responsible for determining whether this immunity test standard should be applied or not, and, if applied, they are responsible for defining the appropriate test levels. Technical committee 77 and its sub-committees are prepared to co-operate with product committees in the evaluation of the value of particular immunity tests for their products. This third edition cancels and replaces the second edition published in 2004 and Amendment 1:2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - rise time and fall time of transients are now defined terms in Clause 3; - the origin of voltage dips and short interruptions is now stated in Clause 4. Keywords: immunity test methods, low-voltage power supply networks

  • Standard
    33 pages
    English language
    sale 10% off
    e-Library read for
    1 day

NEXT ACTION: CCMC to finalize publication
2019-11-13 PeC: BT approved the publication
2019-03-21 - GEM - TC discussed with consultant (C. Maes) at meeting (MArch 2019) - comments accepted - Annex ZA to be dated. Project has normative refverence to PR=63474, which creates a dependency.
2019-02-28 PC: to be flagged for LVD citation when ready
2018-12-17 PC: "Lack of compliance" for LVD, undated references in the Annex ZA and some points in the standards should be clarified
2017-11-21 - Negative assessment is received during CDV stage. Consultant assessment request is missing for FDIS.

  • Amendment
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61225:2019 specifies the performance and the functional characteristics of the low voltage static uninterruptible power supply (SUPS) systems in a nuclear power plant and, for applicable parts, in general for nuclear facilities. An uninterruptible power supply is an electrical equipment which draws electrical energy from a source, stores it and maintains supply in a specified form by means inside the equipment to output terminals. A static uninterruptible power supply (SUPS) has no rotating parts to perform its functions. This third edition cancels and replaces the second edition published in 2005. This edition includes the following significant technical changes with respect to the previous edition: a) the principal objective of this edition is to address the requirements on the static uninterruptible power supplies in nuclear power plants; b) in addition to Instrumentation and Control (I&C) power supplies include all static uninterruptible power supplies; c) emphasize that the static uninterruptible power supplies shall protect the connected equipment (loads) from transients on the on-site AC distribution system (the immunity concept); d) in accordance with the defence-in-depth concept, this standard applies to static uninterruptible power supplies for all equipment, not only for equipment important to safety, with a graded approach to verification and validation; e) addition of the requirement that, when batteries are connected in parallel under abnormal operating conditions, they shall be properly protected with isolation devices to avoid any failure that may impair more than one division of the uninterruptible power supply.

  • Standard
    37 pages
    English language
    sale 10% off
    e-Library read for
    1 day