This document specifies safety requirements, certain functional requirements, and marking of valves and other components with similar bodies, hereinafter called valves, for use in refrigerating systems including heat pumps. This document includes requirements for valves with extension pipes. This document describes the procedure to be followed when designing valve parts subjected to pressure as well as the criteria to be used in the selection of materials. This document describes methods by which reduced impact values at low temperatures may be taken into account in a safe manner. This document applies to the design of bodies and bonnets for pressure relief devices, including bursting disc devices, with respect to pressure containment but it does not apply to any other aspects of the design or application of pressure relief devices. In addition, this document is applicable to valves with a maximum operating temperature not exceeding 200 °C and a maximum allowable pressure not exceeding 160 bar[1]. [1] 1 bar = 0,1 MPa.

  • Standard
    90 pages
    English language
    sale 15% off
  • Standard
    98 pages
    French language
    sale 15% off
  • Draft
    92 pages
    English language
    sale 15% off
  • Draft
    100 pages
    French language
    sale 15% off
  • Standard
    4 pages
    English language
    sale 15% off
  • Standard
    5 pages
    French language
    sale 15% off
  • Draft
    4 pages
    English language
    sale 15% off
  • Draft
    5 pages
    French language
    sale 15% off
  • Standard
    19 pages
    English language
    sale 15% off
  • Standard
    13 pages
    French language
    sale 15% off
  • Draft
    19 pages
    English language
    sale 15% off
  • Draft
    14 pages
    French language
    sale 15% off
  • Standard
    8 pages
    English language
    sale 15% off
  • Standard
    8 pages
    French language
    sale 15% off
  • Draft
    8 pages
    English language
    sale 15% off

ISO 14903:2017 provides the qualification procedure for type approval of the tightness of hermetically sealed and closed components, joints and parts used in refrigerating systems and heat pumps as described in relevant parts of ISO 5149. The sealed and closed components, joints and parts concerned are, in particular, fittings, bursting discs, flanged or fitted assemblies. The tightness of flexible piping made from non-metallic materials is dealt with in ISO 13971. Metal flexible piping are covered by this document. The requirements contained in this document are applicable to joints of maximum DN 50 and components of internal volume of maximum 5 l and maximum weight of 50 kg. ISO 14903:2017 is intended to characterize their tightness stresses met during their operations, following the fitting procedure specified by the manufacturer, and to specify the minimal list of necessary information to be provided by the supplier of a component to the person in charge of carrying out this procedure. It specifies the level of tightness of the component, as a whole, and its assembly as specified by its manufacturer. It applies to the hermetically sealed and closed components, joints and parts used in the refrigerating installations, including those with seals, whatever their material and their design are. ISO 14903:2017 specifies additional requirements for mechanical joints that can be recognized as hermetically sealed joints.

  • Standard
    34 pages
    English language
    sale 15% off
  • Standard
    35 pages
    French language
    sale 15% off

ISO 5149-4:2014 specifies requirements for safety and environmental aspects in relation to operation, maintenance and repair of refrigerating systems and the recovery, reuse and disposal of all types of refrigerant, refrigerant oil, heat transfer fluid, refrigerating system and part thereof. These requirements are intended to minimize risks of injury to persons and damage to property and the environment resulting from improper handling of the refrigerants or from contaminants leading to system breakdown and resultant emission of the refrigerant.

  • Standard
    23 pages
    English language
    sale 15% off
  • Standard
    23 pages
    English language
    sale 15% off
  • Standard
    23 pages
    French language
    sale 15% off
  • Standard
    23 pages
    French language
    sale 15% off

ISO 5149-1:2014 specifies the requirements for the safety of persons and property, provides guidance for the protection of the environment, and establishes procedures for the operation, maintenance, and repair of refrigerating systems and the recovery of refrigerants. ISO 5149-1:2014 specifies the classification and selection criteria applicable to the refrigerating systems and heat pumps. These classification and selection criteria are used in ISO 5149‑2, ISO 5149‑3, and ISO 5149‑4. ISO 5149-1:2014 applies to: a) refrigerating systems, stationary or mobile, of all sizes including heat pumps; b) secondary cooling or heating systems; c) the location of the refrigerating systems; and d) replaced parts and added components after adoption of this part of ISO 5149 if they are not identical in function and in the capacity. ISO 5149-1:2014 applies to fixed or mobile systems, except to vehicle air conditioning systems covered by a specific product standard, e.g. ISO 13043 and SAE J 639. ISO 5149-1:2014 is applicable to new refrigerating systems, extensions or modifications of already existing systems, and for used systems, being transferred to and operated on another site. ISO 5149-1:2014 also applies in the case of the conversion of a system to another refrigerant. Systems containing refrigerants which are not listed in ISO 817 are not covered in ISO 5149-1:2014.

  • Standard
    45 pages
    English language
    sale 15% off
  • Standard
    45 pages
    English language
    sale 15% off
  • Standard
    50 pages
    French language
    sale 15% off
  • Standard
    50 pages
    French language
    sale 15% off

ISO 5149-2:2014 is applicable to the design, construction, and installation of refrigerating systems, including piping, components, materials, and ancillary equipment directly associated with such systems, which are not covered in ISO 5149‑1, ISO 5149‑3, or ISO 5149‑4. It also specifies requirements for testing, commissioning, marking, and documentation. Requirements for secondary heat-transfer circuits are excluded except for any safety devices associated with the refrigerating system. ISO 5149-2:2014 is applicable to new refrigerating systems, extensions or modifications of already existing systems, and for used systems, being transferred to and operated on another site. ISO 5149-2:2014 applies to: a) refrigerating systems, stationary or mobile, of all sizes including heat pumps; b) secondary cooling or heating systems; c) the location of the refrigerating systems; and d)replaced parts and added components after the adoption of this part of ISO 5149, if they are not identical in function and in capacity. ISO 5149-2:2014 does not cover "motor vehicle air conditioners". It does not apply to goods in storage, with respect to spoilage or contamination, but it also applies in the case of the conversion of a system for another refrigerant.

  • Standard
    56 pages
    English language
    sale 15% off
  • Standard
    56 pages
    English language
    sale 15% off
  • Standard
    61 pages
    French language
    sale 15% off
  • Standard
    61 pages
    French language
    sale 15% off

ISO 5149-3:2014 is applicable to the installation site (plant space and services). It specifies requirements for the site for safety, which could be needed because of, but not directly connected with, the refrigerating system and its ancillary components. ISO 5149-3:2014 is applicable to new refrigerating systems, extensions or modifications of existing systems, and for used systems being transferred to and operated on another site. It also applies in the case of the conversion of a system for another refrigerant.

  • Standard
    14 pages
    English language
    sale 15% off
  • Standard
    14 pages
    English language
    sale 15% off
  • Standard
    15 pages
    French language
    sale 15% off
  • Standard
    15 pages
    French language
    sale 15% off

ISO 13971:2012 describes requirements, design and installation of flexible pipe elements (e.g. metallic flexible pipe, metallic flexible tube, vibration isolator, expansion joint) and non-metallic tube used in the refrigerant circuits of refrigerating systems and heat pumps. ISO 13971:2012 also describes the requirements to qualify the tightness and permeability of non-metallic tubes (e.g. plastic) used in evaporating and/or condensing sides of refrigerating systems and heat pumps. ISO 13971:2012 does not apply to flexible pipes that are only occasionally stressed beyond the elastic limit (e.g. during repair work), or to joints that are free to rotate or hinge.

  • Standard
    9 pages
    English language
    sale 15% off
  • Standard
    9 pages
    French language
    sale 15% off

The requirements contained in ISO 14903:2012 are applicable to joints of maximum DN 50 and components of maximum 5 l and maximum mass of 50 kg. ISO 14903:2012 is intended to describe the qualification procedure for type approval of the tightness of components, joints and parts used in refrigerating systems and heat pumps as described in ISO 5149. It characterizes the joint tightness and stresses met when operating, following the fitting procedure specified by the manufacturer, and specifies the minimal list of necessary information to be provided by the supplier of a component to the person in charge of carrying out this procedure. ISO 14903:2012 specifies the level of tightness of the component, as a whole, and its assembly as specified by the manufacturer. ISO 14903:2012 applies to the hermetically sealed and closed components, joints and parts used in refrigerating installations, including those with seals, whatever their material and their design are. ISO 14903:2012 specifies additional requirements for mechanical joints that can be recognized as hermetically sealed joints.

  • Standard
    34 pages
    English language
    sale 15% off

Specifies the requirements relating to the safety of persons and property for the design, construction, installation and operation of refrigerating systems. Gives a classification of the refrigerating systems. Applies to all types of refrigerating systems in which the refrigerant is evaporated and condensed in a closed circuit, including heat pumps and absorption systems, except for systems using water or air as the refrigerant. Is applicable to new refrigerating systems, extensions and modifications of already existing systems, and for used systems.

  • Standard
    34 pages
    English language
    sale 15% off
  • Standard
    36 pages
    French language
    sale 15% off
  • Standard
    36 pages
    French language
    sale 15% off