This document specifies the procedure for the assessment of medical devices and their constituent materials with regard to their potential to induce skin sensitization. This document includes: — details of in vivo skin sensitization test procedures; — key factors for the interpretation of the results. NOTE Instructions for the preparation of materials specifically in relation to the above tests are given in Annex A.

  • Standard
    48 pages
    English language
    sale 15% off
  • Standard
    51 pages
    French language
    sale 15% off
  • Draft
    58 pages
    English language
    sale 15% off
  • Draft
    58 pages
    French language
    sale 15% off

This document specifies the principles and methods for pyrogen testing of medical devices and their materials.

  • Technical report
    16 pages
    English language
    sale 15% off
  • Technical report
    17 pages
    French language
    sale 15% off
  • Draft
    16 pages
    English language
    sale 15% off

This document specifies the requirements for the evaluation of absorbable medical devices during a biological risk assessment based on ISO 10993-1, including a clarification of the terms "absorb", "degrade" and other related terms (see Annex A).

  • Technical specification
    12 pages
    English language
    sale 15% off
  • Draft
    12 pages
    English language
    sale 15% off

This document specifies requirements and gives guidance on the procedures in the preparation of samples and the selection of reference materials for medical device testing primarily in biological test systems primarily in accordance with one or more parts of the ISO 10993 series. Specifically, this document addresses the following: — test sample selection; — selection of representative portions from a medical device; — test sample preparation; — experimental controls; — selection of, and requirements for, reference materials; — preparation of extracts. This document is not applicable to live cells but can be relevant to the material or medical device components of combination products containing live cells. Extractions for chemical characterization are covered in ISO 10993-18. Clause 7, 8, 9, 10 [with the exception of 10.3.5 and 10.3.11 b)], and 11 can apply to extractions for chemical characterization. Information given in C.1 to C.4 can also be relevant.

  • Standard
    21 pages
    English language
    sale 15% off
  • Standard
    22 pages
    French language
    sale 15% off
  • Draft
    26 pages
    English language
    sale 15% off
  • Draft
    28 pages
    French language
    sale 15% off

This document specifies the procedure for the assessment of medical devices and their constituent materials with regard to their potential to produce irritation. The tests are designed to predict and classify the irritation potential of medical devices, materials or their extracts according to ISO 10993‑1 and ISO 10993‑2. This document includes: — pre-test considerations for irritation, including in silico and in vitro methods for dermal exposure; — details of in vitro and in vivo irritation test procedures; — key factors for the interpretation of the results.

  • Standard
    60 pages
    English language
    sale 15% off
  • Standard
    62 pages
    French language
    sale 15% off
  • Standard
    62 pages
    French language
    sale 15% off
  • Draft
    65 pages
    English language
    sale 15% off
  • Draft
    65 pages
    French language
    sale 15% off

This document applies to medical devices other than in vitro diagnostic medical devices manufactured utilizing materials of animal origin, which are non-viable or have been rendered non-viable. It specifies, in conjunction with ISO 14971, a procedure to identify the hazards and hazardous situations associated with such devices, to estimate and evaluate the resulting risks, to control these risks, and to monitor the effectiveness of that control. Furthermore, it outlines the decision process for the residual risk acceptability, taking into account the balance of residual risk, as defined in ISO 14971, and expected medical benefit as compared to available alternatives. This document is intended to provide requirements and guidance on risk management related to the hazards typical of medical devices manufactured utilizing animal tissues or derivatives such as: a) contamination by bacteria, moulds or yeasts; b) contamination by viruses; c) contamination by agents causing transmissible spongiform encephalopathies (TSE); d) material responsible for undesired pyrogenic, immunological or toxicological reactions. For parasites and other unclassified pathogenic entities, similar principles can apply. This document does not stipulate levels of acceptability which, because they are determined by a multiplicity of factors, cannot be set down in such an international standard except for some particular derivatives mentioned in Annex C. Annex C stipulates levels of TSE risk acceptability for tallow derivatives, animal charcoal, milk and milk derivatives, wool derivatives and amino acids. This document does not specify a quality management system for the control of all stages of production of medical devices. This document does not cover the utilization of human tissues in medical devices. NOTE 1 It is not a requirement of this document to have a full quality management system during manufacture. However, attention is drawn to international standards for quality management systems (see ISO 13485) that control all stages of production or reprocessing of medical devices. NOTE 2 For guidance on the application of this document, see Annex A.

  • Standard
    26 pages
    English language
    sale 15% off
  • Standard
    28 pages
    French language
    sale 15% off
  • Draft
    29 pages
    English language
    sale 15% off

This document specifies requirements for controls on the sourcing, collection, and handling (which includes storage and transport) of animals and tissues for the manufacture of medical devices utilizing materials of animal origin other than in vitro diagnostic medical devices. It applies where required by the risk management process as described in ISO 22442‑1. NOTE Selective sourcing is especially important for transmissible spongiform encephalopathy (TSE) risk management, i.e. when utilising animal tissue and/or their derivative originating from bovine, ovine and caprine species, deer, elk, mink or cats. This document does not cover the utilization of human tissues in medical devices. This document does not specify a quality management system for the control of all stages of production of medical devices.

  • Standard
    15 pages
    English language
    sale 15% off
  • Standard
    17 pages
    French language
    sale 15% off
  • Draft
    18 pages
    English language
    sale 15% off

This document addresses good clinical practice for the design, conduct, recording and reporting of clinical investigations carried out in human subjects to assess the clinical performance or effectiveness and safety of medical devices. For post-market clinical investigations, the principles set forth in this document are intended to be followed as far as relevant, considering the nature of the clinical investigation (see Annex I). This document specifies general requirements intended to — protect the rights, safety and well-being of human subjects, — ensure the scientific conduct of the clinical investigation and the credibility of the clinical investigation results, — define the responsibilities of the sponsor and principal investigator, and — assist sponsors, investigators, ethics committees, regulatory authorities and other bodies involved in the conformity assessment of medical devices. NOTE 1 Users of this document need to consider whether other standards and/or national requirements also apply to the investigational device(s) under consideration or the clinical investigation. If differences in requirements exist, the most stringent apply. NOTE 2 For Software as a Medical Device (SaMD) demonstration of the analytical validity (the SaMD's output is accurate for a given input), and where appropriate, the scientific validity (the SaMD's output is associated to the intended clinical condition/physiological state), and clinical performance (the SaMD's output yields a clinically meaningful association to the target use) of the SaMD, the requirements of this document apply as far as relevant (see Reference [4]). Justifications for exemptions from this document can consider the uniqueness of indirect contact between subjects and the SaMD. This document does not apply to in vitro diagnostic medical devices. However, there can be situations, dependent on the device and national or regional requirements, where users of this document might consider whether specific sections and/or requirements of this document could be applicable.

  • Standard
    83 pages
    English language
    sale 15% off
  • Standard
    83 pages
    English language
    sale 15% off
  • Standard
    90 pages
    French language
    sale 15% off
  • Standard
    90 pages
    French language
    sale 15% off
  • Standard
    90 pages
    French language
    sale 15% off
  • Draft
    91 pages
    English language
    sale 15% off

This document provides a compilation of parameters and test methods that can be useful for the identification and evaluation of the physical, i.e. physico‑chemical, morphological and topographical (PMT) properties of materials in finished medical devices. Such an assessment is limited to those properties that are relevant to biological evaluation and the medical device's intended use (clinical application and duration of use) even if such properties overlap with clinical effectiveness. This document does neither address the identification or quantification of degradation products nor the evaluation of the physico-chemical properties of the degraded materials, which are covered in ISO 10993‑9, ISO 10993‑13, ISO 10993‑14 and ISO 10993‑15. Chemical characterization of materials is covered by ISO 10993‑18. The ISO 10993 series is not applicable when the material or device is not in contact with the body directly or indirectly.

  • Technical specification
    13 pages
    English language
    sale 15% off
  • Technical specification
    14 pages
    French language
    sale 15% off

This document specifies a framework for the identification, and if necessary, quantification of constituents of a medical device, allowing the identification of biological hazards and the estimation and control of biological risks from material constituents, using a generally stepwise approach to the chemical characterization which can include one or more of the following: — the identification of its materials of construction (medical device configuration); — the characterization of the materials of construction via the identification and quantification of their chemical constituents (material composition); — the characterization of the medical device for chemical substances that were introduced during manufacturing (e.g. mould release agents, process contaminants, sterilization residues); — the estimation (using laboratory extraction conditions) of the potential of the medical device, or its materials of construction, to release chemical substances under clinical use conditions (extractables); — the measurement of chemical substances released from a medical device under its clinical conditions of use (leachables). This document can also be used for chemical characterization (e.g. the identification and/or quantification) of degradation products. Information on other aspects of degradation assessment are covered in ISO 10993-9, ISO 10993-13, ISO 10993-14 and ISO 10993-15. The ISO 10993 series is applicable when the material or medical device has direct or indirect body contact (see ISO 10993-1 for categorization by nature of body contact). This document is intended for suppliers of materials and manufacturers of medical devices, to support a biological evaluation.

  • Standard
    66 pages
    English language
    sale 15% off
  • Standard
    72 pages
    French language
    sale 15% off

This document provides general principles for the systematic evaluation of the potential and observed degradation of medical devices through the design and performance of in vitro degradation studies. Information obtained from these studies can be used in the biological evaluation described in the ISO 10993 series. This document is applicable to both materials designed to degrade in the body as well as materials that are not intended to degrade. This document is not applicable to: a) the evaluation of degradation which occurs by purely mechanical processes; methodologies for the production of this type of degradation product are described in specific product standards, where available; NOTE Purely mechanical degradation causes mostly particulate matter. Although this is excluded from the scope of this document, such degradation products can evoke a biological response and can undergo biological evaluation as described in other parts of ISO 10993. b) leachable components which are not degradation products; c) medical devices or components that do not contact the patient's body directly or indirectly.

  • Standard
    11 pages
    English language
    sale 15% off
  • Standard
    10 pages
    French language
    sale 15% off

This document describes the basis for, selection of, and general applicability of a threshold of toxicological concern (TTC) value for a constituent present in/on a medical device or released from a medical device. The TTC values in this document can be used for: — comparing to a maximum concentration of an identified or unidentified constituent in an extract (see ISO 10993-18); — supporting toxicological equivalence; — comparing to a maximum exposure dose estimate of an identified constituent (see ISO 10993-17). NOTE Constituent is defined in 3.1. ISO 10993-18 specifies how to convert TTC (µg/d) into a concentration (µg/ml). TTC is not applicable to constituents with adequate toxicity data for deriving a tolerable intake (TI) value (see ISO 10993-17). The TTC values established in this document are protective for carcinogens, systemic toxicants, and reproductive toxicants (see Clause 5). This document does not include TTC values for other biological endpoints assessed as part of the biological evaluation of a medical device, per ISO 10993-1, for example: — cytotoxicity; — irritation; — sensitization; — hemocompatibility; — material mediated pyrogenicity; — local effects that occur in tissues at the site of contact between a medical device and the body (e.g. the observations from implantation studies). The TTC values in this document do not apply to potential exposure via gas pathways of medical devices. For application of TTC for constituents present/released from these devices, see the ISO 18562 series. The TTC values presented in this document are not applicable for the safety assessment of cohort of concern (see 5.3).

  • Technical specification
    7 pages
    English language
    sale 15% off

This document specifies: — the general principles governing the biological evaluation of medical devices within a risk management process; — the general categorization of medical devices based on the nature and duration of their contact with the body; — the evaluation of existing relevant data from all sources; — the identification of gaps in the available data set on the basis of a risk analysis; — the identification of additional data sets necessary to analyse the biological safety of the medical device; — the assessment of the biological safety of the medical device. This document applies to evaluation of materials and medical devices that are expected to have direct or indirect contact with: — the patient's body during intended use; — the user's body, if the medical device is intended for protection (e.g., surgical gloves, masks and others). This document is applicable to biological evaluation of all types of medical devices including active, non-active, implantable and non-implantable medical devices. This document also gives guidelines for the assessment of biological hazards arising from: — risks, such as changes to the medical device over time, as a part of the overall biological safety assessment; — breakage of a medical device or medical device component which exposes body tissue to new or novel materials. Other parts of ISO 10993 cover specific aspects of biological assessments and related tests. Device-specific or product standards address mechanical testing. This document excludes hazards related to bacteria, moulds, yeasts, viruses, transmissible spongiform encephalopathy (TSE) agents and other pathogens.

  • Standard
    41 pages
    English language
    sale 15% off
  • Standard
    44 pages
    French language
    sale 15% off

ISO 10993-11:2017 specifies requirements and gives guidance on procedures to be followed in the evaluation of the potential for medical device materials to cause adverse systemic reactions.

  • Standard
    29 pages
    English language
    sale 15% off
  • Standard
    32 pages
    French language
    sale 15% off

ISO/TR 10993-22:2017 describes considerations for the biological evaluation of medical devices that are composed of or contain nanomaterials. In addition, this guidance can also be used for the evaluation of nano-objects generated as products of degradation, wear, or from mechanical treatment processes (e.g. in situ grinding, polishing of medical devices) from (components of) medical devices that are manufactured not using nanomaterials. ISO/TR 10993-22:2017 includes considerations on the: - characterization of nanomaterials; - sample preparation for testing of nanomaterials; - release of nano-objects from medical devices; - toxicokinetics of nano-objects; - biological evaluation of nanomaterials; - presentation of results; - risk assessment of nanomaterials in the context of medical device evaluation; - biological evaluation report; - nanostructures on the surface of a medical device, intentionally generated during the engineering, manufacturing or processing of a medical device. The following are excluded from this document: - natural and biological nanomaterials, as long as they have not been engineered, manufactured or processed for use in a medical device; - intrinsic nanostructures in a bulk material; - nanostructures on the surface of a medical device, generated as an unintentional by-product during the engineering, manufacturing or processing of a medical device. NOTE Examples of unintentional nanostructures on the surface of a medical device are extrusion draw lines and machining/tool marks. ISO/TR 10993-22:2017 is intended to provide a general framework and highlights important aspects which need to be considered when assessing the safety of medical devices composed of, containing and/or generating nano-objects. Additionally, the document identifies several common pitfalls and obstacles which have been identified when testing nanomaterials compared to bulk materials or small molecule chemical species. As a technical report (TR), this document represents the current technical knowledge related to nanomaterials. No detailed testing protocols are outlined or provided. This document can serve as a basis for future documents containing detailed protocols with a focus on nanomaterial testing.

  • Technical report
    61 pages
    English language
    sale 15% off
  • Technical report
    65 pages
    French language
    sale 15% off

ISO 10993-16:2017 provides principles on designing and performing toxicokinetic studies relevant to medical devices. Annex A describes the considerations for inclusion of toxicokinetic studies in the biological evaluation of medical devices.

  • Standard
    13 pages
    English language
    sale 15% off
  • Standard
    14 pages
    French language
    sale 15% off

ISO 10993-4:2017 specifies general requirements for evaluating the interactions of medical devices with blood. It describes a) a classification of medical devices that are intended for use in contact with blood, based on the intended use and duration of contact as defined in ISO 10993‑1, b) the fundamental principles governing the evaluation of the interaction of devices with blood, c) the rationale for structured selection of tests according to specific categories, together with the principles and scientific basis of these tests. Detailed requirements for testing cannot be specified because of limitations in the knowledge and precision of tests for evaluating interactions of devices with blood. This document describes biological evaluation in general terms and may not necessarily provide sufficient guidance for test methods for a specific device. The changes in this document do not indicate that testing conducted according to prior versions of this document is invalid. For marketed devices with a history of safe clinical use, additional testing according to this revision is not recommended.

  • Standard
    69 pages
    English language
    sale 15% off
  • Standard
    74 pages
    French language
    sale 15% off

ISO 10993-6:2016 specifies test methods for the assessment of the local effects after implantation of biomaterials intended for use in medical devices. ISO 10993-6:2016 applies to materials that are - solid and non-absorbable, - non-solid, such as porous materials, liquids, gels, pastes, and particulates, and - degradable and/or absorbable, which may be solid or non-solid. The test sample is implanted into a site and animal species appropriate for the evaluation of the biological safety of the material. These implantation tests are not intended to evaluate or determine the performance of the test sample in terms of mechanical or functional loading. This part of ISO 10993 can also be applied to medical devices that are intended to be used topically in clinical indications where the surface or lining might have been breached, in order to evaluate local tissue responses. The local effects are evaluated by a comparison of the tissue response caused by a test sample to that caused by control materials used in medical devices whose clinical acceptability and biocompatibility characteristics have been established. The objective of the test methods is to characterize the history and evolution of the tissue response after implantation of a medical device/biomaterial including final integration or absorption/degradation of the material. In particular for degradable/absorbable materials, the degradation characteristics of the material and the resulting tissue response should be determined. ISO 10993-6:2016 does not deal with systemic toxicity, carcinogenicity, teratogenicity or mutagenicity. However, the long-term implantation studies intended for evaluation of local biological effects might provide insight into some of these properties. Systemic toxicity studies conducted by implantation might satisfy the requirements of this part of ISO 10993. When conducting combined studies for evaluating local effects and systemic effects, the requirements of both standards is to be fulfilled.

  • Standard
    29 pages
    English language
    sale 15% off
  • Standard
    30 pages
    French language
    sale 15% off

There are differences between the views of regulatory bodies on the subject of genotoxicity testing. The purpose of this ISO/TR 10993-33: 2015 is to provide background information to facilitate the selection of tests and guidance on the performance of tests.

  • Technical report
    47 pages
    English language
    sale 15% off

ISO 10993-3:2014 specifies strategies for risk estimation, selection of hazard identification tests and risk management, with respect to the possibility of the following potentially irreversible biological effects arising as a result of exposure to medical devices: genotoxicity; carcinogenicity; reproductive and developmental toxicity. ISO 10993-3:2014 is applicable when the need to evaluate a medical device for potential genotoxicity, carcinogenicity, or reproductive toxicity has been established.

  • Standard
    34 pages
    English language
    sale 15% off
  • Standard
    34 pages
    English language
    sale 15% off
  • Standard
    37 pages
    French language
    sale 15% off

The objective of ISO/TR 37137:2014 is to provide interim Part-by-Part guidance on potential adjustments to various test methods within the 10993 series to account for the intentional release of soluble components or degradation products from absorbable medical devices. The content is intended to add clarity and present potentially acceptable approaches for reducing the possibility of erroneous or misleading results due to the nature of the absorbable material. All suggestions should be considered as preliminary and subject to change, with final dispositions implemented through direct modification to the respective parts of ISO 10993. Thus, interim adoption of any of the described adjustments requires an accompanying written justification.

  • Technical report
    17 pages
    English language
    sale 15% off
  • Technical report
    18 pages
    French language
    sale 15% off

This International Standard specifies requirements and guidance for processing practices and managing risk associated with viable cellular components of products regulated as medicinal products, biologics, medical devices and active implantable medical devices, or combinations thereof. It covers viable human materials of autologous as well as allogeneic human origin, obtained from living or deceased donors. For manufacturers of medical products containing viable cells of human origin, this International Standard specifies procedures to be used in processing and handling, as well as those to be used in identifying the hazards and hazardous situations associated with such cells, in order to estimate and evaluate the resulting risks, to control these risks, and to monitor the effectiveness of that control. Furthermore, this International Standard outlines the decision process for the residual risk acceptability, taking into account the balance of residual risk and expected medical benefit as compared to available alternatives. This International Standard provides requirements and guidance on risk management related to the hazards typical of medical products manufactured utilizing viable human materials, such as: a) contamination by bacteria, moulds, yeasts or parasites; b) contamination by viruses; c) contamination by agents causing Transmissible Spongiform Encephalopathies (TSE); d) contaminating material responsible for undesired pyrogenic, immunological or toxicological reactions; e) decomposition of the product and degradation products caused by inadequate handling; f) hazards related to the tumorigenic potential of the cell types used; g) complications resulting from unintended physiological and anatomical consequences (this includes unintended migration of cells, unwanted release of biologically active substances such as hormones and cytokines, and unintended interactions between cellular and non‑cellular components of the product); h) failure of traceability; i) complications resulting from the material eliciting an unintended immunogenic reaction. For the evaluation of contamination with other unclassified pathogenic entities, similar principles might be applicable. Hazards related to genetic modification are outside the scope of this International Standard and are addressed elsewhere. NOTE 1 A definition of "genetically modified" can be found in ASTM F2312. NOTE 2 This International Standard does not specify a quality management system for the control of all stages of production of medical products as described above. If additional national or regional criteria beyond what is defined in this International Standard exist in the country where the medical product will be used, they are also applicable. NOTE 3 Regional requirements can be more stringent than requirements referenced in this International Standard, especially with regard to donor eligibility criteria. This International Standard is not applicable to: — non‑viable materials of human origin; — viable cells of non‑human origin; — blood and its components used for transfusion, germ cells, organs and bone marrow used for transplantation, and other tissues that do not meet the definition of "medical product"; — in vitro diagnostic devices. NOTE 4 For guidance on the application of this International Standard, see Annex A.

  • Standard
    48 pages
    English language
    sale 15% off

ISO/TR 22442-4:2010 offers suggestions for designing and conducting validation assays to help determine if processes used in the manufacture of medical devices derived from non-viable animal tissues might serve to reduce the risk of iatrogenic transmission of transmissible spongiform encephalopathies (TSEs). The TSE-removal methods used to process animal tissues should also reduce the risk of transmitting TSE infections via non-viable tissues of human origin; this Technical Report does not address this issue. Some current information on human tissues and TSEs is presented which may be applied by analogy to other animal tissues. ISO/TR 22442-4:2010 does not intend to imply a need for validation of methods involving specific materials identified as having a "negligible risk" of contamination with TSE agents as listed in Annex C of ISO 22442-1:2007. It is intended to clarify final draft international standards included in the ISO 22442 series, as well as in ISO 14160. ISO/TR 22442-4:2010 builds upon the specific discussion in ISO 22442-3 relative to TSE agents and attempts to summarize the current state of the art in the arena of TSE agent elimination. As the understanding of inactivation and elimination of TSE agents evolves, this document will be revised when possible.

  • Technical report
    14 pages
    English language
    sale 15% off

ISO 10993‑13:2010 provides general requirements for the design of tests in a simulated environment for identifying and quantifying degradation products from finished polymeric medical devices ready for clinical use. ISO 10993‑13:2010 describes two test methods to generate degradation products, an accelerated degradation test as a screening method and a real-time degradation test in a simulated environment. For materials that are intended to polymerize in situ, the set or cured polymer is used for testing. The data generated are used in the biological evaluation of the polymer. ISO 10993‑13:2010 considers only non-resorbable polymers. Similar, but appropriately modified procedures may be applicable for resorbable polymers. ISO 10993‑13:2010 considers only those degradation products generated by a chemical alteration of the finished polymeric device. It is not applicable to degradation of the device induced during its intended use by mechanical stress, wear or electromagnetic radiation or biological factors such as enzymes, other proteins and cellular activity.

  • Standard
    14 pages
    English language
    sale 15% off
  • Standard
    15 pages
    French language
    sale 15% off

ISO 10993-5:2009 describes test methods to assess the in vitro cytotoxicity of medical devices. These methods specify the incubation of cultured cells in contact with a device and/or extracts of a device either directly or through diffusion. These methods are designed to determine the biological response of mammalian cells in vitro using appropriate biological parameters.

  • Standard
    34 pages
    English language
    sale 15% off
  • Standard
    34 pages
    French language
    sale 15% off

ISO 10993-7:2008 specifies allowable limits for residual ethylene oxide (EO) and ethylene chlorohydrin (ECH) in individual EO-sterilized medical devices, procedures for the measurement of EO and ECH, and methods for determining compliance so that devices may be released. Additional background, including guidance and a flowchart showing how the standard is applied are also included in informative annexes. EO-sterilized devices that have no patient contact (e.g., in vitro diagnostic devices) are not covered by ISO 10993-7:2008.

  • Standard
    86 pages
    English language
    sale 15% off
  • Standard
    97 pages
    French language
    sale 15% off

ISO 22442-3:2007 specifies requirements for the validation of the elimination and/or inactivation of viruses and TSE agents during the manufacture of medical devices (excluding in vitro diagnostic medical devices) utilizing animal tissue or products derived from animal tissue, which are non-viable or have been rendered non-viable. It applies where required by the risk management process as described in ISO 22442-1. It does not cover other transmissible and non-transmissible agents.

  • Standard
    22 pages
    English language
    sale 15% off
  • Standard
    23 pages
    French language
    sale 15% off

ISO/TS 10993-20:2006 presents an overview of immunotoxicology with particular reference to the potential immunotoxicity of medical devices. It gives guidance on methods for testing for immunotoxicity of various types of medical devices. ISO/TS 10993-20:2006 is based on several publications written by various groups of immunotoxicologists over the last few decades in which the development of immunotoxicology as a separate entity within toxicology took place.

  • Technical specification
    17 pages
    English language
    sale 15% off

ISO 10993-2:2006 is aimed at those who commission, design and perform tests or evaluate data from animal tests undertaken to assess the biocompatibility of materials intended for use in medical devices, or of the medical devices themselves. It specifies the minimum requirements to be satisfied to ensure and demonstrate that proper provision has been made for the welfare of animals used in animal tests to assess the biocompatibility of materials used in medical devices. ISO 10993-2:2006 also makes recommendations and offers guidance intended to facilitate future further reductions in the overall number of animals used, refinement of test methods to reduce or eliminate pain or distress in animals, and the replacement of animal tests by other scientifically valid means not requiring animal tests. It applies to tests performed on living vertebrate animals, other than man, to establish the biocompatibility of materials or medical devices.

  • Standard
    13 pages
    English language
    sale 15% off
  • Standard
    15 pages
    French language
    sale 15% off

ISO 10993-17:2002 specifies the determination of allowable limits for substances leachable from medical devices. It is intended for use in deriving standards and estimating appropriate limits where standards do not exist. It describes a systematic process through which identified risks arising from toxicologically hazardous substances present in medical devices can be quantified. ISO 10993-17:2002 is not applicable to devices that have no patient contact (e.g. in vitro diagnostic devices). Exposure to a particular chemical substance may arise from sources other than the device, such as food, water or air. ISO 10993-17:2002 does not address the potential for exposure from such sources.

  • Standard
    25 pages
    English language
    sale 15% off
  • Standard
    27 pages
    French language
    sale 15% off

ISO/TR 15499:2016 is applicable to the conduct of biological evaluation of medical devices according to the requirements of ISO 10993‑1. It does not add to, or otherwise change, the requirements of ISO 10993‑1. This document does not include requirements to be used as the basis of regulatory inspection or certification assessment activities. This guidance is applicable to all biological evaluation of all types of medical devices including active, non-active, implantable and non-implantable medical devices.

  • Technical report
    15 pages
    English language
    sale 15% off
  • Technical report
    15 pages
    French language
    sale 15% off

ISO 22442-1:2015 applies to medical devices other than in vitro diagnostic medical devices manufactured utilizing materials of animal origin, which are non-viable or have been rendered non-viable. It specifies, in conjunction with ISO 14971, a procedure to identify the hazards and hazardous situations associated with such devices, to estimate and evaluate the resulting risks, to control these risks, and to monitor the effectiveness of that control. Furthermore, it outlines the decision process for the residual risk acceptability, taking into account the balance of residual risk, as defined in ISO 14971, and expected medical benefit as compared to available alternatives. This part of ISO 22442 is intended to provide requirements and guidance on risk management related to the hazards typical of medical devices manufactured utilizing animal tissues or derivatives such as a) contamination by bacteria, moulds or yeasts; b) contamination by viruses; c) contamination by agents causing Transmissible Spongiform Encephalopathies (TSE); d) material responsible for undesired pyrogenic, immunological or toxicological reactions. For parasites and other unclassified pathogenic entities, similar principles can apply. ISO 22442-1:2015 does not stipulate levels of acceptability which, because they are determined by a multiplicity of factors, cannot be set down in such an International Standard except for some particular derivatives mentioned in Annex C. Annex C stipulates levels of TSE risk acceptability for tallow derivatives, animal charcoal, milk and milk derivatives, wool derivatives and amino acids. ISO 22442-1:2015 does not specify a quality management system for the control of all stages of production of medical devices. ISO 22442-1:2015 does not cover the utilization of human tissues in medical devices. NOTE 1 It is not a requirement of this part of ISO 22442 to have a full quality management system during manufacture. However, attention is drawn to International Standards for quality management systems (see ISO 13485) that control all stages of production or reprocessing of medical devices. NOTE 2 For guidance on the application of this part of ISO 22442, see Annex A.

  • Standard
    27 pages
    English language
    sale 15% off
  • Standard
    28 pages
    French language
    sale 15% off

ISO 22442-2:2015 specifies requirements for controls on the sourcing, collection, and handling (which includes storage and transport) of animals and tissues for the manufacture of medical devices utilizing materials of animal origin other than in vitro diagnostic medical devices. It applies where required by the risk management process as described in ISO 22442‑1. NOTE 1 Selective sourcing is considered to be especially important for transmissible spongiform encephalopathy (TSE) risk management. The manufacturers should refer to ISO 22442‑3 for information on the validation of the elimination and/or inactivation of viruses and TSE agents. ISO 22442-2:2015 does not cover the utilization of human tissues in medical devices. ISO 22442-2:2015 does not specify a quality management system for the control of all stages of production of medical devices. It is not a requirement of this part of ISO 22442 to have a full quality management system during manufacture, but it does specify requirements for some of the elements of a quality management system. Attention is drawn to the standards for quality management systems (see ISO 13485) that control all stages of production or reprocessing of medical devices. The quality management system elements that are required by this part of ISO 22442 can form a part of a quality management system conforming to ISO 13485. NOTE 2 A general principle for the application of this International Standard is that it is advisable to give due consideration to the requirements and recommendations contained in all three parts of the standard.

  • Standard
    15 pages
    English language
    sale 15% off
  • Standard
    17 pages
    French language
    sale 15% off
  • Technical report
    14 pages
    English language
    sale 15% off
  • Technical report
    15 pages
    French language
    sale 15% off

ISO 10993-12:2012 specifies requirements and gives guidance on the procedures to be followed in the preparation of samples and the selection of reference materials for medical device testing in biological systems in accordance with one or more parts of ISO 10993. Specifically, ISO 10993-12:2012 addresses the following: test sample selection; selection of representative portions from a device; test sample preparation; experimental controls; selection of, and requirements for, reference materials; preparation of extracts. ISO 10993-12:2012 is not applicable to live cells, but can be relevant to the material or device components of combination products containing live cells.

  • Standard
    20 pages
    English language
    sale 15% off
  • Standard
    24 pages
    French language
    sale 15% off

ISO 14155:2011 addresses good clinical practice for the design, conduct, recording and reporting of clinical investigations carried out in human subjects to assess the safety or performance of medical devices for regulatory purposes. The principles set forth in ISO 14155:2011 also apply to all other clinical investigations and should be followed as far as possible, depending on the nature of the clinical investigation and the requirements of national regulations. ISO 14155:2011 specifies general requirements intended to protect the rights, safety and well-being of human subjects, ensure the scientific conduct of the clinical investigation and the credibility of the results, define the responsibilities of the sponsor and principal investigator, and assist sponsors, investigators, ethics committees, regulatory authorities and other bodies involved in the conformity assessment of medical devices. ISO 14155:2011 does not apply to in vitro diagnostic medical devices.

  • Standard
    58 pages
    English language
    sale 15% off
  • Standard
    61 pages
    French language
    sale 15% off

ISO 10993-10:2010 describes the procedure for the assessment of medical devices and their constituent materials with regard to their potential to produce irritation and skin sensitization. ISO 10993-10:2010 includes: pretest considerations for irritation, including in silico and in vitro methods for dermal exposure; details of in vivo (irritation and sensitization) test procedures; key factors for the interpretation of the results. Instructions are given for the preparation of materials specifically in relation to the above tests and several special irritation tests are described for application of medical devices in areas other than skin.

  • Standard
    67 pages
    English language
    sale 15% off
  • Standard
    69 pages
    French language
    sale 15% off

ISO 10993-16:2010 gives principles on how toxicokinetic studies relevant to medical devices should be designed and performed. Annex A describes the considerations for inclusion of toxicokinetic studies in the biological evaluation of medical devices.

  • Standard
    11 pages
    English language
    sale 15% off
  • Standard
    13 pages
    French language
    sale 15% off

ISO 10993-9:2008 provides general principles for the systematic evaluation of the potential and observed biodegradation of medical devices and for the design and performance of biodegradation studies. Information obtained from these studies can be used in the biological evaluation described in the ISO 10993 series. ISO 10993-9:2008 considers both non-resorbable and resorbable materials.

  • Standard
    9 pages
    English language
    sale 15% off
  • Standard
    9 pages
    French language
    sale 15% off

ISO 10993-1:2009 describes: the general principles governing the biological evaluation of medical devices within a risk management process; the general categorization of devices based on the nature and duration of their contact with the body; the evaluation of existing relevant data from all sources; the identification of gaps in the available data set on the basis of a risk analysis; the identification of additional data sets necessary to analyse the biological safety of the medical device; the assessment of the biological safety of the medical device.

  • Standard
    21 pages
    English language
    sale 15% off
  • Standard
    21 pages
    English language
    sale 15% off
  • Standard
    22 pages
    French language
    sale 15% off

ISO 22442-2:2007 specifies requirements for controls on the sourcing, collection and handling (which includes storage and transport) of animals and tissues for the manufacture of medical devices utilizing materials of animal origin, other than in vitro diagnostic medical devices. It applies where required by the risk management process as described in ISO 22442-1.

  • Standard
    16 pages
    English language
    sale 15% off
  • Standard
    17 pages
    French language
    sale 15% off

ISO 22442-1:2007 applies to medical devices other than in vitro diagnostic medical devices manufactured utilizing materials of animal origin, which are non-viable or have been rendered non-viable. It specifies, in conjunction with ISO 14971, a procedure to identify the hazards and hazardous situations associated with such devices, to estimate and evaluate the resulting risks, to control these risks, and to monitor the effectiveness of that control. Furthermore, it outlines the decision process for the residual risk acceptability, taking into account the balance of residual risk, as defined in ISO 14971, and expected medical benefit as compared to available alternatives. ISO 22442-1:2007 is intended to provide requirements and guidance on risk management related to the hazards typical of medical devices manufactured utilizing animal tissues or derivatives such as: contamination by bacteria, moulds or yeasts; contamination by viruses; contamination by agents causing Transmissible Spongiform Encephalopathies (TSE); material responsible for undesired pyrogenic, immunological or toxicological reactions.

  • Standard
    26 pages
    English language
    sale 15% off
  • Standard
    28 pages
    French language
    sale 15% off

ISO 10993-12:2007 specifies requirements and gives guidance on the procedures to be followed in the preparation of samples and the selection of reference materials for medical device testing in biological systems in accordance with one or more parts of the ISO 10993 series. Specifically ISO 10993-12:2007 addresses: test sample selection; selection of representative portions from a device; test sample preparation; experimental controls; selection of and requirements for reference materials; preparation of extracts. ISO 10993-12:2007 is not applicable to materials or devices containing live cells.

  • Standard
    17 pages
    English language
    sale 15% off
  • Standard
    18 pages
    French language
    sale 15% off

ISO 10993-6:2007 specifies test methods for the assessment of the local effects after implantation of biomaterials intended for use in medical devices. ISO 10993-6:2007 applies to materials that are: solid and non-biodegradable; degradable and/or resorbable; non-solid, such as porous materials, liquids, pastes and particulates. ISO 10993-6:2007 may also be applied to medical devices that are intended to be used topically in clinical indications where the surface or lining may have been breached, in order to evaluate local tissue responses. This part of ISO 10993 does not deal with systemic toxicity, carcinogenicity, teratogenicity or mutagenicity. However, the long-term implantation studies intended for evaluation of local biological effects may provide insight into some of these properties. Systemic toxicity studies conducted by implantation may satisfy the requirements of ISO 10993-6:2007.

  • Standard
    21 pages
    English language
    sale 15% off
  • Standard
    22 pages
    French language
    sale 15% off

ISO 10993-11:2006 specifies requirements and gives guidance on procedures to be followed in the evaluation of the potential for medical device materials to cause adverse systemic reactions.

  • Standard
    26 pages
    English language
    sale 15% off
  • Standard
    27 pages
    French language
    sale 15% off

ISO/TS 20993:2006 describes a process by which a manufacturer can identify the biological hazards associated with medical devices, estimate and evaluate the risks, control these risks and monitor the effectiveness of the control.

  • Technical specification
    4 pages
    English language
    sale 15% off