IEC 60068-2-38:2021 is available as IEC 60068-2-38:2021 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60068-2-38:2021 specifies a composite test procedure, primarily intended for component type specimens, to determine, in an accelerated manner, the resistance of specimens to the deteriorative effects of high temperature/humidity and cold conditions. This test standard does not apply to spec...view more

    • sale 10% off
    • Standard
      26 pages
      English language
    • e-Library read for
      1 day

This part of IEC 60068 specifies methods of test applicable to specimens which, during transportation, storage or in service, can be subjected to low air pressure. The object of the low air pressure test is to determine the ability of components, equipment or other articles to be used, transported or stored at low air pressure. Components, equipment or other articles to be used, transported or stored under a simultaneous combination of high or low temperature and low air pressure, where the comb...view more

    • sale 10% off
    • Standard
      13 pages
      English language
    • e-Library read for
      1 day

his document is applicable to both self-healing capacitor units and self-healing capacitor banks intended to be used, particularly, for power-factor correction of AC power systems having a rated voltage above 1 000 V and fundamental frequencies of 15 Hz to 60 Hz. The following capacitors are excluded from this document: - shunt power capacitors of the self-healing type for AC systems having a rated voltage up to and including 1 000 V (IEC 60831-1, -2); - shunt power capacitors of the non-self-he...view more

    • sale 10% off
    • Standard
      59 pages
      English language
    • e-Library read for
      1 day

This part of IEC 60068 specifies a test method for assessing the corrosion resistance of electrotechnical products components, equipment and materials in a salt mist environment. Its objective is to verify that the comparative quality of a metallic material, with or without corrosion protection, is maintained when exposed to salt mist. This test method is useful for evaluating the quality and the uniformity of coatings applied to protect metals against corrosion. It is particularly useful for de...view more

    • sale 10% off
    • Standard
      20 pages
      English language
    • e-Library read for
      1 day

See the scope of IEC/IEEE 60980-344:2020. Adoption of IEC/IEEE 60980-344:2020is to be done without modification.

    • sale 10% off
    • Standard
      85 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      85 pages
      English language
    • e-Library read for
      1 day

This document applies to instruments used to measure the activity and/or activity concentration of gamma-emitting radionuclides in food and/or foodstuffs. This document applies to instruments used both gross count type instruments and pulse height analysing type instruments used in field conditions and in measurement facilities. This document does not apply to high-resolution spectrometers that use germanium detectors.

    • sale 10% off
    • Standard
      38 pages
      English language
    • e-Library read for
      1 day

This document specifies the format of binary list-mode data at the output of digital data acquisition devices used for the detection and measurement of radiation. Such data acquisition devices may employ digital signal processors (DSP) and field-programmable gate arrays (FPGA) in combination with memory and a communication interface with a computer.

    • sale 10% off
    • Standard
      113 pages
      English language
    • e-Library read for
      1 day

This document defines the performance requirements of installed monitors used for the detection of gamma and neutron radiation emitters. These monitors are commonly known as radiation portal monitors or RPMs. They are used to monitor vehicles, cargo containers, people, or packages and are typically located at national and international border crossings. They may be used at any location where there is a need for this type of monitoring.

    • sale 10% off
    • Standard
      30 pages
      English language
    • e-Library read for
      1 day

IEC 60172:2020  which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60172:2020 specifies, in accordance with the provisions of IEC 60216-1, a method for evaluating the temperature index of enamelled wire, varnished or unvarnished with an impregnating agent, and of tape wrapped round and rectangular wire, in air at atmospheric pressure by periodically monitoring changes in response to AC proof voltage...view more

    • sale 10% off
    • Standard
      28 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies general requirements for the dust measurement of electric motor-operated tools supplied from mains or from batteries. This European Standard applies to those tools with and without dust extraction unit where dust such as mineral dust containing silica or wood dust is expected.
This part of EN 50632 applies to hammers.

    • sale 10% off
    • Amendment
      4 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Amendment
      4 pages
      English language
    • e-Library read for
      1 day

This part of IEC 62566 provides requirements for achieving highly reliable HDL-Programmed
Devices (HPDs), for use in I&C systems of nuclear power plants performing functions of safety
category B or C as defined by IEC 61226.
The programming of HPDs relies on Hardware Description Languages (HDL) and related
software tools. They are typically based on blank Field Programmable Gate Arrays (FPGAs) or
similar micro-electronic technologies such as Programmable Logic Devices (PLD), Complex
Progra...
view more

    • sale 10% off
    • Standard
      61 pages
      English language
    • e-Library read for
      1 day

This part of IEC 62841 applies to hand-held hammers.
Tools covered by this document include percussion hammers and rotary hammers,
including rotary hammers with the capability to rotate only with the percussion system
disengaged (drill only mode).
This document does not apply to drills and impact drills.
NOTE 101 Drills and impact drills are covered by IEC 62841-2-1.
This document does not apply to tools that are designed exclusively for driving fasteners,
such as palm nailers.

    • sale 10% off
    • Standard
      60 pages
      English language
    • e-Library read for
      1 day

2019-07-05: to be launched to the enquiry together with pr = 70011 (SV)
2019-07-05: Represents common mods. to EN 62841-2-6 (PR=70011)

    • sale 10% off
    • Amendment
      8 pages
      English language
    • e-Library read for
      1 day

IEC 62003:2020 establishes requirements for electromagnetic compatibility testing of instrumentation, control, and electrical equipment supplied for use in systems important to safety at nuclear power plants and other nuclear facilities. The document lists the applicable IEC standards (principally the IEC 61000 series) which define the general test methods, and provides the necessary application-specific parameters and criteria to ensure that nuclear safety requirements are met.
This second edi...
view more

    • sale 10% off
    • Standard
      42 pages
      English language
    • e-Library read for
      1 day

This document provides a framework to manage the interactions between safety and
cybersecurity for nuclear power plant (NPP) systems, taking into account the current SC 45A
standards addressing these issues and the specifics of nuclear I&C programmable digital
systems.
NOTE In this document (as in IEC 62645), cybersecurity relates to prevention of, detection of, and reaction to
malicious acts perpetrated by digital means (cyberattacks). In this context, it does not cover considerations rela...
view more

    • sale 10% off
    • Standard
      29 pages
      English language
    • e-Library read for
      1 day

This part of IEC 60068 specifies a uniform and reproducible method of confirming that
temperature test chambers conform to the requirements specified in the climatic test procedures
of IEC 60068-2-1 and IEC 60068-2-2, when loaded with either heat-dissipating or non heatdissipating
specimens under conditions which take into account air circulation inside the
working space of the chamber. This document is intended primarily for users when conducting
regular chamber performance monitoring.

    • sale 10% off
    • Standard
      15 pages
      English language
    • e-Library read for
      1 day

This part of IEC 60317 specifies the requirements of enamelled round aluminium winding
wires of class 200 with a dual coating. The underlying coating is based on polyester or
polyesterimide resin, which can be modified provided it retains the chemical identity of the
original resin and meets all specified wire requirements. The superimposed coating is based
on polyamide-imide resin.
NOTE A modified resin is a resin that has undergone a chemical change, or contains one or more additives to
...
view more

    • sale 10% off
    • Standard
      13 pages
      English language
    • e-Library read for
      1 day

This part of IEC 60317 specifies the requirements of enamelled rectangular copper winding
wires of class 105 with a sole coating based on polyvinyl acetal resin, which can be modified
provided it retains the chemical identity of the original resin and meets all specified wire
requirements.
NOTE 1 A modified resin is a resin that has undergone a chemical change, or contains one or more additives to
enhance certain performance or application characteristics.
NOTE 2 Polyvinyl acetate is a gen...
view more

    • sale 10% off
    • Standard
      13 pages
      English language
    • e-Library read for
      1 day

This document applies to plugs and receptacles for single or multiple pole connecting devices
used for aeronautical ground lighting applications.
Additional requirements and usage of connecting devices are given in different parts of
IEC 61820 series.
Connecting devices complying with this document are suitable for use in environmental class
E11 according to IEC 61820-1.

    • sale 10% off
    • Standard
      26 pages
      English language
    • e-Library read for
      1 day

This part of IEC 60317 specifies the requirements of polyester glass-fibre wound, silicone
resin or varnish impregnated bare, grade 1 or grade 2 enamelled rectangular copper winding
wires, temperature index 200. The impregnating agent is a silicone containing resin or
varnish.
The range of nominal conductor dimensions covered by this document is:
– width: min. 2,0 mm max. 16,0 mm;
– thickness: min. 0,80 mm max. 5,60 mm.
NOTE For this type of wire, the heat shock test is inappropriate and ...
view more

    • sale 10% off
    • Standard
      13 pages
      English language
    • e-Library read for
      1 day

This document establishes requirements and provides guidance for the development and
management of effective computer security programmes for I&C programmable digital
systems. Inherent to these requirements and guidance is the criterion that the power plant
I&C programmable digital system security programme complies with the applicable country’s
requirements.
This document defines adequate measures for the prevention of, detection of and reaction to
malicious acts by digital means (cyberat...
view more

    • sale 10% off
    • Standard
      56 pages
      English language
    • e-Library read for
      1 day

This part of IEC 61788 specifies a test method for determining the DC critical current of short
RE (rare earth)-Ba-Cu-O (REBCO) composite superconductor specimens that have a shape of
straight flat tape. This document applies to test specimens shorter than 300 mm and having a
rectangular cross section with an area of 0,03 mm2 to 7,2 mm2, which corresponds to tapes
with width ranging from 1,0 mm to 12,0 mm and thickness from 0,03 mm to 0,6 mm.
This method is intended for use with superconduc...
view more

    • sale 10% off
    • Standard
      30 pages
      English language
    • e-Library read for
      1 day

This International Standard specifies the test procedures, conditions and methods for
determining the main performance parameters and operational characteristics of electroslag
remelting furnaces.
Measurements and tests that are solely used for the verification of safety requirements of the
installations are outside the scope of this document and are covered by IEC 60519-1 and
IEC 60519-8.
This document applies to industrial electroslag remelting furnaces, the rated capacity of which
is e...
view more

    • sale 10% off
    • Standard
      26 pages
      English language
    • e-Library read for
      1 day

This part of IEC 60317 specifies the requirements of enamelled rectangular copper winding
wires of class 200 with a sole coating based on polyesterimide resin, which can be modified
provided it retains the chemical identity of the original resin and meets all specified wire
requirements.
NOTE A modified resin is a resin that has undergone a chemical change or contains one or more additives to
enhance certain performance or application characteristics.
The range of nominal conductor dimensi...
view more

    • sale 10% off
    • Standard
      12 pages
      English language
    • e-Library read for
      1 day

This part of IEC 60317 specifies the requirements of polyester glass-fibre wound unvarnished
and fused bare, grade 1 or grade 2 enamelled round copper winding wires, temperature index
155.
The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-10:2017.
NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be
established. Consequently, a class based on the requirements for temperature index and heat shock temperature
...
view more

    • sale 10% off
    • Standard
      13 pages
      English language
    • e-Library read for
      1 day

This part of IEC 60317 specifies the requirements of enamelled rectangular copper winding
wires of class 120 with a sole coating based on polyvinyl acetal or polyvinyl formal resin,
which can be modified provided it retains the chemical identity of the original resin and meets
all specified wire requirements
NOTE 1 A modified resin is a resin that has undergone a chemical change, or contains one or more additives to
enhance certain performance or application characteristics.
NOTE 2 Polyvin...
view more

    • sale 10% off
    • Standard
      13 pages
      English language
    • e-Library read for
      1 day

IEC 60317-0-6:2020 is available as IEC 60317-0-6:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60317-0-6:2020 specifies the general requirements of glass-fibre wound resin or varnish impregnated, bare or enamelled, round copper winding wires. The range of nominal conductor diameters is given in the relevant specification sheet. This second edition cancels and replaces the first edition...view more

    • sale 10% off
    • Standard
      21 pages
      English language
    • e-Library read for
      1 day

This part of IEC 60317 specifies the requirements of polyester glass-fibre wound, resin or
varnish impregnated, bare or grade 1 or grade 2 enamelled rectangular copper winding wires,
temperature index 155. The impregnating agent can be, for instance, epoxy, polyester, or
polyesterimide resin based.
The range of nominal conductor dimensions covered by this document is:
– width: min. 2,0 mm max. 16,0 mm;
– thickness: min. 0,80 mm max. 5,60 mm.
NOTE For this type of wire, the heat shock test...
view more

    • sale 10% off
    • Standard
      13 pages
      English language
    • e-Library read for
      1 day

This part of IEC 60317 specifies the requirements of polyester glass-fibre wound fused,
unvarnished, bare or grade 1 or grade 2 enamelled rectangular copper winding wires,
temperature index 155.
NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be
established. Consequently, a class based on the requirements for temperature index and heat shock temperature
cannot be specified.
The range of nominal conductor dimensions covered by t...
view more

    • sale 10% off
    • Standard
      13 pages
      English language
    • e-Library read for
      1 day

This part of IEC 60317 specifies the requirements of paper tape covered round copper winding
wires. This covering consists of two or more layers of paper tape and is primarily intended for
winding coils for oil immersed transformers.
The range of nominal conductor diameters covered by this document is:
– 0,500 mm up to and including 5,000 mm.
The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-1:2013.
The paper tapes included in this document are restricted to those sp...
view more

    • sale 10% off
    • Standard
      14 pages
      English language
    • e-Library read for
      1 day

This part of IEC 60317 specifies the requirements of paper tape covered round aluminium
winding wires. This covering consists of two or more layers of paper tape and is primarily
intended for winding coils for oil immersed transformers.
The range of nominal conductor diameters covered by this document is:
– 0,500 mm up to and including 5,000 mm.
The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-3:2008 and
IEC 60317-0-3:2008/AMD1:2013.
The paper tapes included in thi...
view more

    • sale 10% off
    • Standard
      14 pages
      English language
    • e-Library read for
      1 day

This part of IEC 60317 specifies the general requirements of enamelled rectangular copper
winding wires.
The range of nominal conductor dimensions is given in 4.1 and the relevant specification
sheet.

    • sale 10% off
    • Standard
      30 pages
      English language
    • e-Library read for
      1 day

This part of IEC 60317 specifies the requirements of enamelled round copper winding wires of
class 120 with a sole coating based on polyvinyl acetal or polyvinyl formal resin, which can be
modified provided it retains the chemical identity of the original resin and meets all specified
wire requirements.
NOTE 1 A modified resin is a resin that has undergone a chemical change, or contains one or more additives to
enhance certain performance or application characteristics.
NOTE 2 Polyvinyl ac...
view more

    • sale 10% off
    • Standard
      14 pages
      English language
    • e-Library read for
      1 day

This part of IEC 60317 specifies the requirements of paper tape covered rectangular aluminium
winding wires. This covering consists of two or more layers of paper tape and is primarily
intended for winding coils for oil immersed transformers.
The range of nominal conductor dimensions covered by this document is:
– width: min. 2,00 mm max. 16,0 mm;
– thickness: min. 0,80 mm max. 5,60 mm.
The paper tapes included in this document are restricted to those specified in IEC 60554-1 and
IEC 6055...
view more

    • sale 10% off
    • Standard
      14 pages
      English language
    • e-Library read for
      1 day

This part of IEC 60317 specifies the requirements of polyester glass-fibre wound resin/varnish
impregnated bare, grade 1 or grade 2 enamelled round copper winding wires, temperature
index 155. The impregnating agent can be, for instance, epoxy, polyester, or polyesterimide
resin based.
The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-10:2017.
NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be
established...
view more

    • sale 10% off
    • Standard
      13 pages
      English language
    • e-Library read for
      1 day

This part of IEC 60519 specifies particular safety requirements for electroslag remelting
equipment and installations.
This document specifies safety requirements applicable to mainly electroheating installations
for remelting and, in some cases, for refining processes of metals through direct resistance
heating of a conductive slag.
The object of this document is to specify the particular requirements for the safety of persons
in or around an electroslag remelting furnace. The general req...
view more

    • sale 10% off
    • Standard
      28 pages
      English language
    • e-Library read for
      1 day

This part of IEC 60317 specifies general requirements of glass-fibre wound, resin or varnish
impregnated, bare or enamelled rectangular copper wire.
The range of nominal conductor dimensions is given in 4.1 and the relevant specification sheet.

    • sale 10% off
    • Standard
      27 pages
      English language
    • e-Library read for
      1 day

This part of IEC 60317 specifies the requirements of polyester glass-fibre wound resin/varnish
impregnated, bare, grade 1 or grade 2 enamelled round copper winding wire, temperature
index 180.
NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be
established. Consequently, a class based on the requirements for temperature index and heat shock temperature
cannot be specified.
The nominal conductor diameters are specified in IEC 603...
view more

    • sale 10% off
    • Standard
      13 pages
      English language
    • e-Library read for
      1 day

DOW=DOR+48 months is applied to all parts in EN IEC 62841 series
2018-11-02: this prA covers common mods to prEN IEC 62841-3-9 (PR=67950)

    • sale 10% off
    • Amendment
      9 pages
      English language
    • e-Library read for
      1 day

This part of IEC 60317 specifies the requirements of polyester glass-fibre wound, resin or
varnish impregnated bare, grade 1 or grade 2 enamelled rectangular copper winding wires,
temperature index 180. The impregnating agent can be, for instance, epoxy, polyester, or
polyesterimide resin based.
NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be
established. Consequently, a class based on the requirements for temperature index a...
view more

    • sale 10% off
    • Standard
      13 pages
      English language
    • e-Library read for
      1 day

This part of IEC 60721 provides guidance on the use of all parts of IEC 60721-3. It contains
background information including information on the application and limitation of the classes
given in various parts of IEC 60721-3 which can be used in the design, limitation of conditions
and protection of equipment.
Reference to IEC 60721-3-0 is important in order to avoid misuse of the classes defined in the
other parts of IEC 60721-3.

    • sale 10% off
    • Standard
      11 pages
      English language
    • e-Library read for
      1 day

This part of IEC 60317 specifies the requirements of polyester glass-fibre wound silicone
resin/varnish impregnated, bare, grade 1 or grade 2 enamelled round copper winding wire,
temperature index 200.
NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be
established. Consequently, a class based on the requirements for temperature index and heat shock temperature
cannot be specified.
The nominal conductor diameters are specified i...
view more

    • sale 10% off
    • Standard
      13 pages
      English language
    • e-Library read for
      1 day

This part of IEC 62282 provides safety related requirements for construction, operation under
normal and abnormal conditions and the testing of fuel cell modules. It applies to fuel cell
modules with the following electrolyte chemistry:
• alkaline;
• polymer electrolyte (including direct methanol fuel cells)2;
• phosphoric acid;
• molten carbonate;
• solid oxide;
• aqueous solution of salts.
Fuel cell modules can be provided with or without an enclosure and can be operated at
significa...
view more

    • sale 10% off
    • Standard
      48 pages
      English language
    • e-Library read for
      1 day

This part of IEC 62841 applies to transportable mitre saws intended to be used with a
toothed saw blade for cutting wood and analogous materials, plastics and nonferrous metals
except magnesium with a saw blade diameter not exceeding 410 mm, which hereinafter might
simply be referred to as saw or tool.
This International Standard does not apply to mitre saws intended to cut other metals, such
as magnesium, steel and iron. This document does not apply to mitre saws with an automatic
feeding...
view more

    • sale 10% off
    • Standard
      38 pages
      English language
    • e-Library read for
      1 day

2020-01-06 JF: the Annex ZZ which had been approved by  the BT is not the most recent one -> need to submit the correct Annex ZZ to the BT. The BT document under preparation.
2019-11-05 JF: Through the BT decision D163/C100, the BT approved the revised Annex ZZ of the standard. Standard under publlication.
NEXT ACTION: CCMC ACTION BY 2019-08-30: submission of the revised Annex ZZ for the BT approval.
Compliant assessment of the Annex ZA received.
2019-05-08 JF: HAS Consultants confir...
view more

    • sale 10% off
    • Amendment
      9 pages
      English language
    • e-Library read for
      1 day

This part of IEC 60519 specifies the general safety requirements for industrial installations or
equipment intended for electroheating (EH) and electroheating based treatment
technologies as well as for electromagnetic processing of materials (EPM). This document
deals with the significant hazards, hazardous situations or hazardous events relevant to
industrial EH and EPM equipment, as listed in Annex A, for normal operation and for single
fault condition as well as under conditions of reas...
view more

    • sale 10% off
    • Standard
      105 pages
      English language
    • e-Library read for
      1 day

IEC 61788-7 describes measurement of the surface resistance (Rs) ofsuperconductors at microwave frequencies by the standard two-resonator method. The objectof measurement is the temperature dependence of Rs at the resonant frequency.The applicable measurement range of Rs for this method is as follows:- Frequency: 8 GHz < f < 30 GHz- Measurement resolution: 0,01 mΩ at 10 GHzThe Rs data at the measured frequency, and that scaled to 10 GHz, assuming the f 2 rule forcomparison, is reported.

    • sale 10% off
    • Standard
      46 pages
      English language
    • e-Library read for
      1 day

TAN - // IEC Corrigendum

    • sale 10% off
    • Corrigendum
      3 pages
      French language
    • e-Library read for
      1 day