This European Standard specifies a manual method for the determination of the concentration of fluorinated compounds expressed in HF. Two cases are presented:
- first case: the measurand is the concentration of hydrofluoric acid and gaseous and bound to particulates fluorides,
- second case: the measurand is the concentration of hydrofluoric acid and gaseous fluorides.
Three analytical techniques are proposed: ionometry, spectrophotometry and ion-exchange chromatography.
This European Standa...
view more

    • sales 10% off
    • Technical specification
      71 pages
      English language
    • e-Library read for
      1 day
    • sales 10% off
    • Draft
      74 pages
      English language
    • e-Library read for
      1 day

This document specifies a method for collecting samples of airborne particulate matter for subsequent determination of metals and metalloids using inductively coupled plasma — atomic emission spectrometry (ICP-AES). Samples obtained using the method described herein can also be subsequently analysed for elemental composition by other instrumental methods, such as atomic absorption spectrometry (AAS) or inductively coupled plasma mass spectrometry (ICP-MS).
The method is not applicable to the sa...
view more

    • sales 15% off
    • Standard
      17 pages
      English language
    • sales 10% off
    • Standard
      22 pages
      English language
    • e-Library read for
      1 day
    • sales 10% off
    • Standard
      22 pages
      English language
    • e-Library read for
      1 day
    • sales 15% off
    • Standard
      18 pages
      French language

This European Technical Specification specifies the standard reference method (SRM) for the measurement of carbon dioxide (CO2) based on the Infrared (IR) absorption principle. It includes the sampling and the gas conditioning system, and allows the determination of the CO2 in flue gases emitted to the atmosphere from ducts and stacks.
This European Standard specifies the characteristics to be determined and the performance criteria to be fulfilled by portable automated measuring systems (P-AMS...
view more

    • sales 10% off
    • Technical specification
      34 pages
      English language
    • e-Library read for
      1 day
    • sales 10% off
    • Technical specification
      35 pages
      English language
    • e-Library read for
      1 day

This document specifies a number of suitable methods for preparing test solutions from samples of airborne particulate matter collected using the method specified in ISO 15202‑1, for subsequent determination of metals and metalloids by ICP‑AES using the method specified in ISO 15202‑3. It contains information about the applicability of the methods with respect to the measurement of metals and metalloids for which limit values have been set. The methods can also be used in the measurement of some...view more

    • sales 10% off
    • Standard
      54 pages
      English language
    • e-Library read for
      1 day
    • sales 15% off
    • Standard
      55 pages
      French language
    • sales 10% off
    • Standard
      54 pages
      English language
    • e-Library read for
      1 day
    • sales 15% off
    • Standard
      49 pages
      English language

This Standard contains specifications for active sampling of bioaerosols from exhaust air flowing through a defined cross-section of a stack. It defines general principles that have to be taken into account during an isokinetic sampling campaign for bioaerosols by bubbling the exhaust air through a specific impinge designed for emission measurements.
In the Standard the application with culturable organisms is specified but the same principle might be applicable for other analysis methods (e.g....
view more

    • sales 10% off
    • Standard
      57 pages
      English language
    • e-Library read for
      1 day
    • sales 10% off
    • Draft
      52 pages
      English language
    • e-Library read for
      1 day

This document specifies the quality assurance and quality control procedures related to automated dust arrestment plant monitors.
This document applies to two types of instruments commonly used for dust arrestment plant control purposes:
— filter dust monitors that are configured in mass concentration units (e.g. mg/m3) and is used for dust arrestment control purposes;
— filter leakage monitors that indicate a change in the emission levels or a change in the magnitude of the dust pulses creat...
view more

    • sales 10% off
    • Standard
      21 pages
      English language
    • e-Library read for
      1 day
    • sales 10% off
    • Draft
      20 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies a method for the sampling and analysis of NH3 in ambient air using
diffusive sampling.
It can be used for NH3 measurements at ambient levels but the concentration range and exposure time are sampler dependent and the end user shall use the working conditions for the various devices as recommended by the manufacturer.
Denuders may be used as a surrogate reference method, and for this reason their use is also described in this European Standard.

    • sales 10% off
    • Standard
      45 pages
      English language
    • e-Library read for
      1 day
    • sales 10% off
    • Draft
      47 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies the performance requirements on data acquisition and handling systems (DAHS) regarding implementation of the procedures defined in EN 17255-1 including
— data acquisition;
— data processing;
— data storage;
— data output;
— generation of reports;
— system functions;
— data security;
— documentation.
This European Standard supports the requirements of EN 14181 and legislation such as the IED and E-PRTR. It does not preclude the use of additional features ...
view more

    • sales 10% off
    • Standard
      20 pages
      English language
    • e-Library read for
      1 day
    • sales 10% off
    • Draft
      21 pages
      English language
    • e-Library read for
      1 day

This document describes a standard method for determining particle number size distributions in ambient air in the size range from 10 nm to 800 nm at total concentrations up to approximately 105 cm–3 with a time resolution of a few minutes. The standard method is based on a Mobility Particle Size Spectrometer (MPSS) used with a bipolar diffusion charger and a Condensation Particle Counter (CPC) as the detector. The document describes the performance characteristics and minimum requirements of th...view more

    • sales 10% off
    • Technical specification
      63 pages
      English language
    • e-Library read for
      1 day
    • sales 10% off
    • Technical specification
      62 pages
      English language
    • e-Library read for
      1 day

This document specifies performance requirements and test methods for the evaluation of procedures for measuring metals and metalloids in airborne particles sampled onto a suitable collection substrate.
This document specifies a method for estimating the uncertainties associated with random and systematic errors and combining them to calculate the expanded uncertainty of the measuring procedure as a whole, as prescribed in ISO 20581.
This document is applicable to measuring procedures in which...
view more

    • sales 10% off
    • Standard
      45 pages
      English language
    • e-Library read for
      1 day
    • sales 10% off
    • Draft
      42 pages
      English language
    • e-Library read for
      1 day

ISO 14966 specifies a method using scanning electron microscopy for determination of the concentration of inorganic fibrous particles in the air. The method specifies the use of gold-coated, capillary-pore, track-etched membrane filters, through which a known volume of air has been drawn. Using energy-dispersive X-ray analysis, the method can discriminate between fibres with compositions consistent with those of the asbestos varieties (e.g. serpentine and amphibole), gypsum, and other inorganic ...view more

    • sales 15% off
    • Standard
      49 pages
      English language
    • sales 10% off
    • Standard
      55 pages
      English language
    • e-Library read for
      1 day
    • sales 10% off
    • Draft
      56 pages
      English language
    • e-Library read for
      1 day

This document specifies the fundamental structure and the most important performance characteristics of automated measuring systems for carbon monoxide (CO), carbon dioxide (CO2) and oxygen (O2) to be used on stationary source emissions. This document describes methods and equipment for the measurement of concentrations of these gases. The method allows continuous monitoring with permanently installed measuring systems of CO, CO2 and O2 emissions. This international standard describes extractive...view more

    • sales 15% off
    • Standard
      52 pages
      English language
    • sales 10% off
    • Standard
      56 pages
      English language
    • e-Library read for
      1 day

This document specifies a manual method of measurement including sampling and different analytical methods for the determination of the mass concentration of ammonia (NH3) in the waste gas of industrial plants, for example combustion plants or agricultural plants. All compounds which are volatile at the sampling temperature and produce ammonium ions upon dissociation during sampling in the absorption solution are measured by this method, which gives therefore the volatile ammonia content of the ...view more

    • sales 10% off
    • Standard
      52 pages
      English language
    • e-Library read for
      1 day
    • sales 10% off
    • Draft
      51 pages
      English language
    • e-Library read for
      1 day

This document specifies a reference method using transmission electron microscopy for the determination of airborne asbestos fibres and structures in in a wide range of ambient air situations, including the interior atmospheres of buildings, and for a detailed evaluation for asbestos structures in any atmosphere. The specimen preparation procedure incorporates ashing and dispersion of the collected particulate, so that all asbestos is measured, including the asbestos originally incorporated in p...view more

    • sales 15% off
    • Standard
      84 pages
      French language
    • sales 15% off
    • Standard
      80 pages
      English language
    • sales 10% off
    • Standard
      87 pages
      English language
    • e-Library read for
      1 day
    • sales 10% off
    • Draft
      90 pages
      English language
    • e-Library read for
      1 day

This document specifies requirements for an indoor air quality management system. It is applicable to any organization that wishes to:
a) establish a system for the management of the quality of indoor air;
b) implement, maintain and continually improve the indoor air quality management system;
c) ensure conformity to the indoor air quality management system;
d) demonstrate conformity to this document.
It is applicable to the indoor environments of all kinds of facilities, installations and ...
view more

    • sales 15% off
    • Standard
      23 pages
      English language
    • sales 15% off
    • Standard
      26 pages
      French language
    • sales 10% off
    • Standard
      29 pages
      English language
    • e-Library read for
      1 day
    • sales 10% off
    • Draft
      29 pages
      English language
    • e-Library read for
      1 day

This document specifies a reference method using transmission electron microscopy for the determination of airborne asbestos fibres and structures in in a wide range of ambient air situations, including the interior atmospheres of buildings, and for a detailed evaluation for asbestos structures in any atmosphere. The method allows determination of the type(s) of asbestos fibres present and also includes measurement of the lengths, widths and aspect ratios of the asbestos structures. The method c...view more

    • sales 15% off
    • Standard
      75 pages
      French language
    • sales 15% off
    • Standard
      72 pages
      English language
    • sales 10% off
    • Standard
      78 pages
      English language
    • e-Library read for
      1 day
    • sales 10% off
    • Draft
      84 pages
      English language
    • e-Library read for
      1 day

This document specifies procedures for establishing quality assurance for automated measuring systems (AMS) installed on industrial plants for the determination of the concentration of greenhouse gases in flue and waste gas and other flue gas parameters. This part of ISO 14385 specifies the following: - a procedure to maintain and demonstrate the required quality of the measurement results during the normal operation of an AMS, by checking that the zero and span characteristics are consistent wi...view more

    • sales 15% off
    • Standard
      32 pages
      English language
    • sales 10% off
    • Standard
      37 pages
      English language
    • e-Library read for
      1 day
    • sales 10% off
    • Standard
      37 pages
      English language
    • e-Library read for
      1 day

This document specifies the procedures for establishing quality assurance for automated measuring systems (AMS) installed on industrial plants for the determination of the concentration of greenhouse gases in flue and waste gas and other flue gas parameters. This part of ISO 14385 specifies a procedure to calibrate the AMS and determine the variability of the measured values obtained by an AMS, which is suitable for the validation of an AMS following its installation. This part of ISO 14385 is d...view more

    • sales 15% off
    • Standard
      35 pages
      English language
    • sales 10% off
    • Standard
      40 pages
      English language
    • e-Library read for
      1 day
    • sales 10% off
    • Standard
      40 pages
      English language
    • e-Library read for
      1 day

This document, along with ISO 16000-38, specifies the measurement method for determining the mass concentration of primary, secondary and tertiary aliphatic and aromatic amines in indoor air using accumulated sampling and high-performance liquid chromatography (HPLC) coupled with tandem mass spectrometry (MS-MS) or high-resolution mass spectrometry (HRMS). The analytical procedure is covered by this document. The sampling procedure and the manufacturing of the samplers are covered by ISO 16000-3...view more

    • sales 15% off
    • Standard
      12 pages
      English language
    • sales 10% off
    • Standard
      17 pages
      English language
    • e-Library read for
      1 day
    • sales 10% off
    • Standard
      17 pages
      English language
    • e-Library read for
      1 day

This document specifies a large bag sampling method for measuring volatile organic compounds (VOCs), formaldehyde and other carbonyl compounds which are emitted from vehicle interior parts into the air inside road vehicles. This method is intended for evaluation of large new vehicle interior parts, and complete assemblies. This is a screening method to compare similar car components under similar test conditions on a routine basis. Evaluating VOC emissions of vehicle interior parts is an importa...view more

    • sales 15% off
    • Standard
      15 pages
      English language
    • sales 10% off
    • Standard
      20 pages
      English language
    • e-Library read for
      1 day
    • sales 10% off
    • Standard
      20 pages
      English language
    • e-Library read for
      1 day