IEC 60079-15:2017 is available as IEC 60079-15:2017 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60079-15:2017 specifies requirements for the construction, testing and marking for Group II electrical equipment with type of protection “n” which includes; sealed devices “nC”, hermetically sealed devices “nC”, non-incendive components “nC” and restricted breathing enclosures “nR” intended for use in explosive gas atmospheres. This part of IEC 60079 applies to electrical equipment where the rated input voltage does not exceed 15 kV r.m.s. AC or DC including where the internal working voltages of the Ex product exceeds 15 kV, for example starters for HID luminaires. This part of IEC 60079 supplements and modifies the general requirements of IEC 60079-0, except as indicated in Table 1 (Clause 1). Where a requirement of this part of IEC 60079 conflicts with a requirement of IEC 60079-0, the requirement of this part of IEC 60079 takes precedence. This fifth edition cancels and replaces the fourth edition, published in 2010, and constitutes a technical revision. Refer to the Forward of the document for a complete listing of the technical changes between edition 5.0 and the previous edition of the document.
Keywords: Group II electrical equipment with type of protection “n”

  • Standard
    63 pages
    English and French language
    sale 15% off

IEC 60079-15:2010 specifies requirements for the construction, testing and marking for Group II electrical equipment with type of protection, "n" intended for use in explosive gas atmospheres. This standard applies to electrical equipment where the rated voltage does not exceed 15 kV r.m.s. a.c. or d.c. This standard supplements and modifies the general requirements of IEC 60079-0, except as indicated in Table 1. Where a requirement of this standard conflicts with a requirement of IEC 60079-0, the requirement of this standard takes precedence. The significant technical changes with respect to the previous edition are as follows:
- addition of equipment protection levels;
- removal of the requirements for energy-limited "nL" and associated energy limited apparatus "[nL]";
- removal of the requirements for encapsulated Devices "nC";
- requirements for electrical connections expanded and clarified;
- requirements for electrical connections expanded and clarified;
- requirements for luminaire ballasts expanded and clarified;
- requirements for evaluation and testing of motor rotors clarified;
- 15 kV limit for equipment protection by type of protection "n" added;
- spacing requirement for voltages above 10 kV modified;
- requirements for restricted breathing enclosures modified;
- modification to requirements for motor rotors and stators;
- addition of Annex A (informative);
- and undated references to IEC 60079-0 included.
This publication is to be read in conjunction with IEC 60079-0:2007. The contents of the Interpretation sheet 1 of September 2016 have been included in this copy.