IEC 60079-26:2021 specifies requirements for construction, testing and marking for Ex Equipment that contains parts of the equipment with different Equipment Protection Levels (EPLs) and a separation element. This equipment is mounted across a boundary where different EPLs are required, for example between different gas hazardous areas, dust hazardous areas or gas hazardous areas adjacent to dust hazardous areas.
Separation elements are considered for both electrical and non-electrical equipmen...
view more

    • sale 15% off
    • Standard
      47 pages
      English and French language

IEC 60079-10-1:2020 is concerned with the classification of areas where flammable gas or vapour hazards may arise and may then be used as a basis to support the proper design, construction, operation and maintenance of equipment for use in hazardous areas. It is intended to be applied where there may be an ignition hazard due to the presence of flammable gas or vapour, mixed with air, but it does not apply to: a) mines susceptible to firedamp; b) the processing and manufacture of explosives; c) ...view more

    • sale 10% off
    • Standard
      115 pages
      English language
    • e-Library read for
      1 day

IEC 60079-47:2021(E), which is a technical specification, specifies requirements for the construction, marking and documenting of apparatus, systems and installations for use with the 2-Wire Intrinsically Safe Ethernet concept (2-WISE), such as the physical layer specification for 2-Wire Ethernet 10BASE-T1L as defined in IEEE 802.3cg.
2-WISE is a concept for an advanced physical layer (APL), designed to simplify the examination process for intrinsic safety parameters of components and cabling w...
view more

    • sale 15% off
    • Technical specification
      14 pages
      English language

IEC 60079-10-1:2020 is concerned with the classification of areas where flammable gas or vapour hazards may arise and may then be used as a basis to support the proper design, construction, operation and maintenance of equipment for use in hazardous areas.
It is intended to be applied where there may be an ignition hazard due to the presence of flammable gas or vapour, mixed with air, but it does not apply to:
a) mines susceptible to firedamp;
b) the processing and manufacture of explosives;
...
view more

    • sale 15% off
    • Standard
      236 pages
      English and French language

IEC 60079-25:2020 contains the specific requirements for design, construction and assessment of intrinsically safe systems, Type of Protection “i”, intended for use, as a whole or in part, in locations in which the use of Group I, II or III Ex Equipment is required.
This document supplements and modifies the general requirements of IEC 60079-0 and the intrinsic safety standard IEC 60079-11. Where a requirement of this standard conflicts with a requirement of IEC 60079-0 or IEC 60079-11, the req...
view more

    • sale 15% off
    • Standard
      117 pages
      English and French language

2021-03-25 CV: rejected for OJEU citation but corrigenda are out of EY scope
TAN - // IEC Corrigendum

    • sale 10% off
    • Corrigendum
      3 pages
      English and French language
    • e-Library read for
      1 day

EN-IEC 60079-19 gives instructions, principally of a technical nature, on the repair, overhaul, reclamation and modification of Ex equipment designed for use in explosive atmospheres; - applies to overhaul and repair which mitigates deficiencies identified during operation, inspection and maintenance; - does not give advice on cable and wiring systems which can require a renewal when the equipment is re-installed; and - is not applicable to Type of Protection “m”.

    • sale 10% off
    • Standard
      85 pages
      English language
    • e-Library read for
      1 day

ISO/IEC 80079-34:2018 specifies particular requirements and information for establishing and maintaining a quality management system to manufacture Ex Products in accordance with the certificates. While it does not preclude the use of other quality management systems that are compatible with the objectives of ISO 9001:2015 and which provide equivalent results, the minimum requirements are given in this document. This second edition cancels and replaces the first edition, published in 2011, and c...view more

    • sale 10% off
    • Standard
      89 pages
      English language
    • e-Library read for
      1 day

IEC 60050-426:2020 gives terms specifically relevant to explosive atmospheres. This new edition reviews and complements the previous one. This terminology is consistent with the terminology developed in the other specialized parts of the IEV.
It has the status of a horizontal standard in accordance with IEC Guide 108.

    • sale 15% off
    • Standard
      430 pages
      English and French language

2021-03-25 CV: rejected for OJEU citation but corrigenda are out of EY scope
TAN - // IEC Corrigendum

    • sale 10% off
    • Corrigendum
      3 pages
      English and French language
    • e-Library read for
      1 day

This part of ISO/IEC 80079 provides guidance on classification of gases and vapours. It describes a test method intended for the measurement of the maximum experimental safe gaps (MESG) for gas-air mixtures or vapour-air mixtures under normal conditions of temperature  and pressure (20 °C, 100 kPa) so as to permit the selection of an appropriate group of equipment. The standard describes also a test method intended for use in the determination of the auto-ignition temperature (AIT) of a vapour-a...view more

    • sale 10% off
    • Standard
      93 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies general requirements for construction, testing and performance, and describes the test methods that apply to portable, transportable and fixed apparatus for the measurement of the oxygen concentration in gas mixtures indicating up to 25 % (v/v). The apparatus, or parts thereof, may be intended for use in potentially explosive atmospheres (see 4.1) and in mines susceptible to firedamp. In the case of inert gas purging (inertization), it applies also to apparatus w...view more

    • sale 10% off
    • Standard
      37 pages
      English language
    • e-Library read for
      1 day

IEC 60079-19:2019 gives instructions, principally of a technical nature, on the repair, overhaul, reclamation and modification of equipment designed for use in explosive atmospheres; it is not applicable to maintenance, other than when repair and overhaul cannot be disassociated from maintenance, neither does it give advice on cable entry systems which may require a renewal when the equipment is re-installed. This fourth edition cancels and replaces the third edition published in 2010 together w...view more

    • sale 10% off
    • Standard
      85 pages
      English language
    • e-Library read for
      1 day

This Technical Specification specifies the construction, testing, installation and maintenance of Power i apparatus and systems which utilise electronically controlled spark duration limitation to maintain an adequate level of intrinsic safety.
This Technical Specification contains requirements for intrinsically safe apparatus and wiring intended for use in explosive atmospheres and for associated apparatus intended for connection to intrinsically safe circuits entering such atmospheres.
This ...
view more

    • sale 10% off
    • Technical specification
      54 pages
      English language
    • e-Library read for
      1 day

ISO/IEC 80079-20-1:2017 is published as a dual log standard and provides guidance on classification of gases and vapours. It describes a test method intended for the measurement of the maximum experimental safe gaps (MESG) for gas-air mixtures or vapour-air mixtures under normal conditions of temperature and pressure (20 °C, 101,3 kPa) so as to permit the selection of an appropriate group of equipment. This document also describes a test method intended for use in the determination of the auto-i...view more

    • sale 10% off
    • Standard
      93 pages
      English language
    • e-Library read for
      1 day

IEC 60079-19:2019 gives instructions, principally of a technical nature, on the repair, overhaul, reclamation and modification of equipment designed for use in explosive atmospheres; it is not applicable to maintenance, other than when repair and overhaul cannot be disassociated from maintenance, neither does it give advice on cable entry systems which may require a renewal when the equipment is re-installed.
This fourth edition cancels and replaces the third edition published in 2010 together ...
view more

    • sale 15% off
    • Standard
      166 pages
      English and French language

IEC 62990-1:2019 specifies general requirements for design, function and performance, and describes the test methods that apply to portable, transportable, and fixed equipment for the detection and concentration measurement of toxic gases and vapours in workplace atmospheres and other industrial and commercial applications.
This document is applicable to continuously sensing equipment whose primary purpose is to provide an indication, alarm and/or other output function the purpose of which is t...
view more

    • sale 15% off
    • Standard
      124 pages
      English and French language

This Technical Specification specifies the construction, testing, installation and maintenance of Power i apparatus and systems which utilise electronically controlled spark duration limitation to maintain an adequate level of intrinsic safety. This Technical Specification contains requirements for intrinsically safe apparatus and wiring intended for use in explosive atmospheres and for associated apparatus intended for connection to intrinsically safe circuits entering such atmospheres. This Te...view more

    • sale 10% off
    • Technical specification
      54 pages
      English language
    • e-Library read for
      1 day

This part of IEC 60079 specifies requirements for the construction, testing and marking for
Group II electrical equipment with type of protection “n” which includes; sealed devices “nC”,
hermetically sealed devices “nC”, non-incendive components “nC” and restricted breathing
enclosures “nR” intended for use in explosive gas atmospheres. This part of IEC 60079
applies to electrical equipment where the rated input voltage does not exceed 15 kV r.m.s. AC or
DC including where the internal work...
view more

    • sale 10% off
    • Standard
      36 pages
      English language
    • e-Library read for
      1 day

This Standard defines the requirements for the use of explosives on all spacecraft and other space products including launch vehicles. It addresses the aspects of design, analysis, verification, manufacturing, operations and safety.
This standard may be tailored for the specific characteristics and constraints of a space project in conformance with ECSS-S-ST-00.

    • sale 10% off
    • Standard
      76 pages
      English language
    • e-Library read for
      1 day

NEW!IEC 60079-15:2017 is available as IEC 60079-15:2017 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60079-15:2017 specifies requirements for the construction, testing and marking for Group II electrical equipment with type of protection “n” which includes; sealed devices “nC”, hermetically sealed devices “nC”, non-incendive components “nC” and restricted breathing enclosures “nR” intended...view more

    • sale 10% off
    • Standard
      36 pages
      English language
    • e-Library read for
      1 day

IEC TS 60079-42:2019 provides guidance for equipment manufacturers where electrical safety devices are used to reduce the likelihood of potential ignition sources becoming effective in Ex Equipment located in Explosive Atmospheres. Electrical safety devices perform a safety function to control potential ignition sources from both, electrical or non-electrical Ex Equipment in explosive atmospheres.
This Technical Specification may also be applied to a combination of elements performing a safety ...
view more

    • sale 15% off
    • Technical specification
      48 pages
      English and French language

IEC/TS 60079-32-1:2013(E) gives guidance about the equipment, product and process properties necessary to avoid ignition and electrostatic shock hazards arising from static electricity as well as the operational requirements needed to ensure safe use of the equipment, product or process. It can be used in a risk assessment of electrostatic hazards or for the preparation of product family or dedicated product standards for electrical or non-electrical machines or equipment. The purpose of this do...view more

    • sale 10% off
    • Technical report
      182 pages
      English language
    • e-Library read for
      1 day

NEW!IEC 60079-0:2017 is available as IEC 60079-0:2017 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60079-0:2017 specifies the general requirements for construction, testing and marking of Ex Equipment and Ex Components intended for use in explosive atmospheres. The standard atmospheric conditions (relating to the explosion characteristics of the atmosphere) under which it may be assumed th...view more

    • sale 10% off
    • Standard
      148 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Standard
      148 pages
      English language
    • e-Library read for
      1 day

IEC - Corrected version

    • sale 10% off
    • Corrigendum
      3 pages
      English and French language
    • e-Library read for
      1 day

2018-05-03 CV: CEN BT C218/2017 - decision: new Annex ZA to be published as amendment prior to offer EN ISO/IEC 80079-39:2016 + amd for citation in the OJEU

    • sale 10% off
    • Amendment
      6 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies minimum requirements and tests for electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen using software and/or digital technologies.
This European Standard is applicable to fixed, transportable and portable apparatus intended for use in domestic premises as well as commercial and industrial applications.
This European Standard does not apply to external sampling systems, or to apparatus of laboratory or scientific ty...
view more

    • sale 10% off
    • Standard
      32 pages
      English language
    • e-Library read for
      1 day

ISO/IEC 80079-34:2018 specifies particular requirements and information for establishing and maintaining a quality management system to manufacture Ex Products in accordance with the certificates. While it does not preclude the use of other quality management systems that are compatible with the objectives of ISO 9001:2015 and which provide equivalent results, the minimum requirements are given in this document. This second edition cancels and replaces the first edition, published in 2011, and c...view more

    • sale 15% off
    • Standard
      140 pages
      English and French language

NEW!IEC 60079-0:2017 is available as IEC 60079-0:2017 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60079-0:2017 specifies the general requirements for construction, testing and marking of Ex Equipment and Ex Components intended for use in explosive atmospheres. The standard atmospheric conditions (relating to the explosion characteristics of the atmosphere) under which it may be assumed th...view more

    • sale 10% off
    • Standard
      148 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Standard
      148 pages
      English language
    • e-Library read for
      1 day

2018-05-03 CV: CEN BT C218/2017 - decision: new Annex ZA to be published as amendment prior to offer EN ISO/IEC 80079-39:2016 + amd for citation in the OJEU

    • sale 10% off
    • Amendment
      6 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Amendment
      8 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Amendment
      8 pages
      English language
    • e-Library read for
      1 day

This standard specifies requirements for explosion pressure resistant and explosion pressure shock-resistant equipment. This standard is applicable to process vessels and systems. It is not applicable to individual items of equipment such as motors and gearboxes that may be designed to withstand an internal explosion, which are subject of EN 13463-3. This standard is valid for atmospheres having pressures ranging from 800 hPa to 1100 hPa and temperatures ranging from -20 °C to +60 °C. This stand...view more

    • sale 10% off
    • Standard
      36 pages
      English language
    • e-Library read for
      1 day

2017-05-29 - Annex ZZ available - Ensure it is issued with //FDIS

    • sale 10% off
    • Amendment
      7 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies requirements for explosion resistant equipment which will be able to withstand an internal explosion without rupturing and will not give rise to dangerous effects to the surroundings. It is applicable to equipment (vessels and systems) where explosions are considered to be an exceptional load case.
There are two types of explosion resistant equipment: explosion pressure resistant and explosion pressure shock-resistant equipment (see Figure 1).
(...)
Explosion ...
view more

    • sale 10% off
    • Standard
      36 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Amendment
      8 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Amendment
      8 pages
      English language
    • e-Library read for
      1 day

This part of IEC 60079 gives requirements for the design, construction, assessment,
verification and marking of rooms used to protect internal equipment:
– located in a Zone 1 or Zone 2 or Zone 21 or Zone 22 explosive atmosphere (an area
normally requiring an equipment protection level (EPL) Gb, Gc, Db or Dc) without an
internal source of gas/vapour release and protected by pressurization;
– located in a Zone 2 explosive atmosphere (an area normally requiring EPL Gc) with or
without an int...
view more

    • sale 10% off
    • Standard
      38 pages
      English language
    • e-Library read for
      1 day

ISO/IEC 80079-20-1: 2017 is published as a dual log standard and provides guidance on classification of gases and vapours. It describes a test method intended for the measurement of the maximum experimental safe gaps (MESG) for gas-air mixtures or vapour-air mixtures under normal conditions of temperature and pressure (20 °C, 101,3 kPa) so as to permit the selection of an appropriate group of equipment. This document also describes a test method intended for use in the determination of the auto-...view more

    • sale 15% off
    • Standard
      176 pages
      English and French language

IEC 60079-0:2017 is also available as IEC 60079-0:2017 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60079-0:2017 specifies the general requirements for construction, testing and marking of Ex Equipment and Ex Components intended for use in explosive atmospheres. The standard atmospheric conditions (relating to the explosion characteristics of the atmosphere) under which it may be assum...
view more

    • sale 10% off
    • Standard
      133 pages
      English language
    • e-Library read for
      1 day
    • sale 15% off
    • Standard
      279 pages
      English and French language

This part of IEC 60079 provides guidance for the application of electrical resistance trace heating systems in areas where explosive atmospheres may be present, with the exclusion of those classified as requiring EPL Ga/Da (traditional relationship to Zone 0 and Zone 20 respectively). It provides recommendations for the design, installation, maintenance and repair of trace heating systems including associated control and monitoring equipment. It does not cover devices that operate by induction h...view more

    • sale 10% off
    • Standard
      74 pages
      English language
    • e-Library read for
      1 day

IEC 60079-15:2017 is available as IEC 60079-15:2017 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60079-15:2017 specifies requirements for the construction, testing and marking for Group II electrical equipment with type of protection “n” which includes; sealed devices “nC”, hermetically sealed devices “nC”, non-incendive components “nC” and restricted breathing enclosures “nR” intended...
view more

    • sale 15% off
    • Standard
      63 pages
      English and French language

2017-05-29 - Annex ZZ available - Ensure it is issued with //FDIS

    • sale 10% off
    • Amendment
      7 pages
      English language
    • e-Library read for
      1 day

IEC TS 60079-43:2017(E) which is a Technical Specification, provides guidance for equipment for use in explosive atmospheres in environments which may include ambient temperatures below -20 °С, and additional adverse conditions, including maritime applications. The purpose of this document is to provide recommendations to be considered for the design, manufacture and use of equipment. It is intended that this document be used for equipment operating within the environmental range specified on th...view more

    • sale 15% off
    • Technical specification
      17 pages
      English language