Fire fighting — Wheeled fire extinguishers — Performance and construction

ISO 11601:2008 specifies the principal requirements intended to ensure the safety, reliability and performance of wheeled fire extinguishers.

Lutte contre l'incendie — Extincteurs sur roues — Performances et construction

General Information

Status
Withdrawn
Publication Date
07-Dec-2008
Withdrawal Date
07-Dec-2008
Current Stage
9599 - Withdrawal of International Standard
Completion Date
17-Jul-2017
Ref Project

Relations

Buy Standard

Standard
ISO 11601:2008 - Fire fighting -- Wheeled fire extinguishers -- Performance and construction
English language
26 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

INTERNATIONAL ISO
STANDARD 11601
Second edition
2008-12-15

Fire fighting — Wheeled fire
extinguishers — Performance and
construction
Lutte contre l'incendie — Extincteurs sur roues — Performances et
construction




Reference number
ISO 11601:2008(E)
©
ISO 2008

---------------------- Page: 1 ----------------------
ISO 11601:2008(E)
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe’s licensing policy, this file may be printed or viewed but
shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In
downloading this file, parties accept therein the responsibility of not infringing Adobe’s licensing policy. The ISO Central Secretariat
accepts no liability in this area.
Adobe is a trademark of Adobe Systems Incorporated.
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation
parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In
the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below.


COPYRIGHT PROTECTED DOCUMENT


©  ISO 2008
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or
ISO’s member body in the country of the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland

ii © ISO 2008 – All rights reserved

---------------------- Page: 2 ----------------------
ISO 11601:2008(E)
Contents Page
Foreword. iv
1 Scope . 1
2 Normative references . 1
3 Terms and definitions. 1
4 Types of wheeled fire extinguishers. 3
5 Extinguishing media, propellants and fill densities. 4
6 Performance . 5
7 Fire performance tests . 10
8 Construction requirements. 11
9 Colour and marking. 21
10 Manuals. 24
Bibliography . 26

© ISO 2008 – All rights reserved iii

---------------------- Page: 3 ----------------------
ISO 11601:2008(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the
International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 11601 was prepared by Technical Committee ISO/TC 21, Equipment for fire protection and fire fighting,
Subcommittee SC 2, Manually transportable fire extinguishers.
This second edition cancels and replaces the first edition (ISO 11601:1999), which has been technically
revised.
iv © ISO 2008 – All rights reserved

---------------------- Page: 4 ----------------------
INTERNATIONAL STANDARD ISO 11601:2008(E)

Fire fighting — Wheeled fire extinguishers — Performance and
construction
1 Scope
This International Standard specifies the principal requirements intended to ensure the safety, reliability and
performance of wheeled fire extinguishers.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
ISO 37, Rubber, vulcanized or thermoplastic — Determination of tensile stress-strain properties
ISO 3768, Metallic coatings — Neutral salt spray test (NSS test)
ISO 5923, Fire protection — Fire extinguishing media — Carbon dioxide
ISO 7165, Fire fighting — Portable fire extinguishers — Performance and construction
ISO 7201-1, Fire protection — Fire extinguishing media — Halogenated hydrocarbons — Part 1:
Specifications for halon 1211 and halon 1301
ISO 7202, Fire protection – Fire extinguishing media — Powder
ISO 7203-1, Fire extinguishing media — Foam concentrates — Part 1: Specification for low expansion foam
concentrates for top application to water-immiscible liquids
ISO 7203-2, Fire extinguishing media — Foam concentrates — Part 2: Specification for medium and high
expansion foam concentrates for top application to water-immiscible liquids
ISO 14520-1, Gaseous fire-extinguishing systems — Physical properties and system design — Part 1:
General requirements
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1
batch
group of the same products made on the same production line using the same lot of materials during one
production shift
3.2
body
metal shell of an extinguisher designed to contain the extinguishing media including any skirt
© ISO 2008 – All rights reserved 1

---------------------- Page: 5 ----------------------
ISO 11601:2008(E)
3.3
bulk range
discharge range of an extinguisher when 50 % of its extinguishing medium has been expelled with the
discharge valve fully open
3.4
burst pressure
P
b
pressure at which the extinguisher cylinder ruptures
3.5
charge of extinguisher
mass or volume of extinguishing medium contained in the extinguisher expressed in volume (litres) for water-
based extinguishers and in mass (kilograms) for other extinguishers
3.6
classification of fires
Class A fires involving solid materials, usually of an organic nature, in which combustion normally takes
place with the formation of glowing embers
Class B fires involving liquids or liquefiable solids
Class C fires involving gases
Class D fires involving metals
3.7
clean agent
electrically non-conductive gaseous or vaporizing liquid fire-extinguishing medium that does not leave a
residue upon evaporation
3.8
closure
component, other than a safety device or pressure indicator, subject to internal pressure and used to close off
and seal the body
3.9
complete discharge
point in the discharge of an extinguisher when the internal pressure has equalized with the external pressure
with the control valve being kept fully open
3.10
effective discharge time
time from the commencement of discharge of the extinguishing medium at the nozzle to the gas point of the
discharge stream with the control valve fully open
3.11
extinguisher
appliance containing an extinguishing medium which may be discharged and directed onto a fire by the action
of internal pressure
NOTE Discharge may be achieved by
a) stored pressure (constant pressurization of the extinguishing media container), or
b) cartridge or cylinder operated device (pressurization at the time of use by the release of a pressurizing gas stored in
a separate high-pressure cartridge or container)
2 © ISO 2008 – All rights reserved

---------------------- Page: 6 ----------------------
ISO 11601:2008(E)
3.12
extinguishing medium
substance contained in the extinguisher which causes extinction
3.13
fill density
mass in kilograms of extinguishing medium per litre of container volume as fitted for use, complete with valve
and internal fittings
3.14
gas point
point where the medium discharge changes from predominately medium to predominately expellant gas
3.15
lowest observable adverse effect level
l.o.a.e.l.
the lowest concentration at which an adverse physiological or toxicological effect has been observed
3.16
maximum service pressure
P
ms
equilibrium pressure developed in a normally charged and pressurized extinguisher which is conditioned at
60 °C for at least 18 h
3.17
propellant
non-flammable compressed gas used to expel the extinguishing medium
3.18
rechargeable extinguisher
extinguisher designed and intended to be recharged after use
3.19
service pressure
P
s
equilibrium pressure developed in a normally charged and pressurized extinguisher conditioned at 20 °C
for at least 18 h
3.20
test pressure
P
t
for low-pressure wheeled extinguishers, P is the higher of 1,43 × P , 2,5 × P or 2,0 MPa
t ms s
3.21
wheeled fire extinguisher
appliance on wheels having a total mass more than 20 kg but not greater than 450 kg, which is designed to be
operated and transported to the fire by one person
4 Types of wheeled fire extinguishers
4.1 General
4.1.1 Wheeled fire extinguishers are described by the type of extinguishing medium which they contain. At
present, the types of wheeled fire extinguishers are:
⎯ water-based;
⎯ powder;
© ISO 2008 – All rights reserved 3

---------------------- Page: 7 ----------------------
ISO 11601:2008(E)
⎯ carbon dioxide;
⎯ clean agent.
NOTE In some countries, the manufacture and use of clean agents is regulated by the Montreal Protocol or by
national regulations.
4.1.2 Water-based wheeled fire extinguishers may contain plain water, or water with additives such as
wetting agents, viscosity-increasing agents, or flame-retardant or foaming agents.
NOTE Currently there are no ISO International Standards covering additives added to water to produce antifreeze,
wetting or other special characteristics.
4.1.3 Powders may be of the “BC” or “ABC” types, or may be specially prepared for Class D fires.
4.1.4 Wheeled fire extinguishers may have two extinguisher bodies per axle. Each extinguisher body may
contain the same or a different extinguishing medium provided they are compatible with each other.
5 Extinguishing media, propellants and fill densities
5.1 Extinguishing media
5.1.1 Carbon dioxide
Carbon dioxide used in wheeled fire extinguishers shall comply with ISO 5923.
5.1.2 Clean agents
Clean agents used in wheeled fire extinguishers shall comply with ISO 7201-1 (alternatively, ISO 14520-1).
NOTE In some countries, the manufacture and use of clean agents is regulated by the Montreal Protocol or by
national regulations.
5.1.3 Powder
Powder used in wheeled fire extinguishers shall comply with ISO 7202.
IMPORTANT — Exception: powders for use on Class D fires.
5.1.4 Foam concentrates
Foam concentrates used in wheeled fire extinguishers shall comply with ISO 7203-1 (alternatively,
ISO 7203-2).
5.2 Propellants
The propellant for stored pressure and cartridge-operated wheeled fire extinguishers shall be air, argon,
carbon dioxide, helium, nitrogen or mixtures of these gases having a maximum dewpoint of − 60 °C.
IMPORTANT — Exception: propellant for stored pressure water-based wheeled fire extinguishers need
not meet the dewpoint requirement.
5.3 Fill density
The fill density for carbon dioxide wheeled fire extinguishers shall not exceed 0,75 kg/l.
4 © ISO 2008 – All rights reserved

---------------------- Page: 8 ----------------------
ISO 11601:2008(E)
The fill density for clean agent wheeled fire extinguishers shall not exceed the values given in ISO 7201-1
(alternatively, ISO 14520-1).
NOTE These fill densities may be modified subject to national pressure vessel regulations.
5.4 Filling tolerance
The actual charge of a wheeled fire extinguisher shall be the nominal charge within the following limits:
a) water-based extinguishers: +0, −5 % by volume;
b) powder-based extinguishers: ± 2 % by mass;
c) carbon dioxide and clean agent extinguishers: +0, −5 % by mass.
5.5 Charges
5.5.1 Nominal charge
The following are the recommended charges for wheeled fire extinguishers:
a) water-based extinguishers: 20 l, 45 l, 60 l and 125 l;
b) powder-based extinguishers: 20 kg, 50 kg, 100 kg and 150 kg;
c) carbon dioxide and clean agent extinguishers: 10 kg, 20 kg, 30 kg and 50 kg.
NOTE Other nominal capacities are allowed.
5.5.2 Gross weight
The gross weight of a wheeled fire extinguisher shall not exceed 450 kg.
6 Performance
6.1 Operating temperatures
Wheeled fire extinguishers shall be capable of operating reliably within one of the following temperature
ranges:
+5 °C to +60 °C
−5 °C to +60 °C
−10 °C to +60 °C
−20 °C to +60 °C
−30 °C to +60 °C
−40 °C to +60 °C
−55 °C to +60 °C
NOTE The temperature range selected from the above ranges shall be marked on the extinguisher (see 9.2.5).
© ISO 2008 – All rights reserved 5

---------------------- Page: 9 ----------------------
ISO 11601:2008(E)
6.2 Effective discharge time and bulk range of discharge
6.2.1 Effective discharge time
6.2.1.1 The effective discharge time of water-based type wheeled fire extinguishers shall be not less than
40 s or more than 210 s.
6.2.1.2 The effective discharge time of wheeled fire extinguishers with a Class A rating, except water-
based types, shall be not less than 30 s.
6.2.1.3 The effective discharge time of wheeled fire extinguishers other than water-based types shall be
not less than 20 s.
6.2.2 Bulk range
6.2.2.1 The bulk range of wheeled fire extinguishers with a Class A rating shall be not less than 6 m
when tested in accordance with 6.2.2.2.
IMPORTANT — Exception: for water-based type wheeled fire extinguishers fitted with a spray nozzle,
the bulk range maybe reduced to 3 m.
6.2.2.2 Condition the extinguisher for not less than 18 h at a temperature of (20 ± 3) °C and place it in its
normal operating position with the discharge nozzle held horizontally at a height of 1 m.
Fully discharge the extinguisher with the control valve fully open within 5 min of conditioning.
Record the bulk range at the time corresponding to 50 % of the effective discharge time.
NOTE If the range of effective discharge is difficult to determine visually, supplementary means, such as collection
boxes for water, foam or powder extinguishers or condensing plates for carbon dioxide and clean agent extinguishers may
be used.
6.3 Resistance to temperature changes
6.3.1 Requirements
Wheeled fire extinguishers shall be able to operate at temperatures between the minimum marked on the
extinguisher (see 6.1) and +60 °C. After the test described in 6.3.2, they shall satisfy the following
requirements:
a) the extinguisher shall operate as intended;
b) the extinguisher shall commence discharge within 5 s of the control valve being opened;
c) not more than 10 % of the initial charge of media shall remain within the extinguisher after complete
discharge.
6.3.2 Test procedure
Subject four extinguishers to the temperature cycles defined in Table 1, two extinguishers to each cycle.
6 © ISO 2008 – All rights reserved

---------------------- Page: 10 ----------------------
ISO 11601:2008(E)
Table 1 — Temperature cycles
a
Duration Cycle No. 1
Cycle No. 2
h
a
24 ± 1 Store at minimum storage and use Store at (60 ± 2) °C
temperature
(+0, −2) °C
24 ± 1 Store at (20 ± 5) °C Store at (20 ± 5) °C
Store at minimum storage and use
24 ± 1 Store at (60 ± 2) °C
temperature
(+0, −2) °C
a
The storage temperatures refer to the ambient temperature within the conditioning chamber.

Operate the extinguisher with the control valve fully open within 5 min of its removal from the conditioning
chamber.
NOTE If it is not possible to operate the extinguisher within 5 min after its removal from the conditioning chamber,
suitable means, such as insulation shall be used to maintain the extinguisher at the conditioning temperature until
discharge.
6.4 Retention of charge
6.4.1 Checking
6.4.1.1 Wheeled fire extinguishers and gas cartridges or cylinders shall be designed so as to permit their
charge to be checked at regular intervals when they are installed.
6.4.1.2 The charge of the following types of wheeled fire extinguishers shall be measured by weighing:
a) all types of gas cartridges for wheeled fire extinguishers;
b) carbon dioxide wheeled fire extinguishers;
c) stored pressure wheeled fire extinguishers of various types including some clean agents in which a loss
of 1 % of total charged extinguisher mass is accompanied by a pressure loss of not more than 10 % of
the service pressure at (20 ± 2) °C.
6.4.1.3 The charge of stored pressure wheeled fire extinguishers of types not covered by 6.4.1.2 b) and
6.4.1.2 c) and non-liquefied gas containers fitted with a gauge shall be checked by direct measurement of
internal pressure at (20 ± 2) °C. For this purpose, the extinguisher shall be fitted with a pressure gauge ported
into the extinguisher body.
NOTE If a connection is provided to which an independent pressure measuring appliance can be attached for
checking the pressure gauge, the connection is equipped with a pressure retaining cap.
6.5 Intermittent discharge test
6.5.1 A wheeled fire extinguisher conditioned at (20 ± 5) °C and at (60 ± 2) °C shall operate in such a
manner that not more than 1 s elapses from the time the control valve is operated until the extinguishing
medium starts to discharge and shall cease the discharge of medium within 1 s after closing the control valve.
Not more than 10 % of the initial charge remains within the extinguisher after complete discharge.
© ISO 2008 – All rights reserved 7

---------------------- Page: 11 ----------------------
ISO 11601:2008(E)
6.5.2 The test shall be conducted following conditioning at each of the temperatures specified in 6.5.1 for at
least 18 h. The extinguisher shall be operated intermittently by opening and closing the control valve in cycles
of 5 s open and 5 s closed until the end of discharge.
6.6 Resistance to corrosion
6.6.1 External corrosion test
Wheeled fire extinguishers shall be subjected to a salt spray test as defined in ISO 3768 for a period of 480 h
and then shall be washed carefully to remove any salt deposits. Two samples shall be tested, either two of the
same size or one sample each of two different sizes from the same family.
The operating forces, or energy if applicable, shall comply with the method of operation specified in 8.14.
The pressure gauge on stored pressure extinguishers shall remain watertight and functional. See 8.16.7.
There shall be no corrosion of the metal of the extinguisher likely to impair its operation or safety.
Discolouration or superficial corrosion of non-ferrous materials is acceptable but galvanic corrosion between
dissimilar metals is not permitted.
Test samples employing smaller extinguisher bodies are permitted to be used for this test provided they are
fabricated using the same material and processes and have the same protective coatings or corrosion
protection system.
The length of the discharge hose assembly is permitted to be reduced to 1,4 m for this test.
6.6.2 Internal corrosion test for water and foam extinguishers
Wheeled fire extinguishers, charged in accordance with the manufacturer’s instructions, shall be subjected
eight times to the temperature cycle defined in Table 2.
Table 2 — Temperature cycles
Stage Duration Conditioning chamber temperature
h °C

a
1
(24 ± 1)
2 (W 24) (20 ± 5)
3
(24 ± 1) (60 ± 5)
4 (W 24)
(20 ± 5)
a
Lowest temperature marked on extinguisher, (± 5) °C. See 6.1.
Test samples employing smaller extinguisher bodies are permitted to be used for this test provided they are
fabricated using the same material and processes and have the same protective coatings or corrosion
protection system.
A liquid bath shall not be used.
The duration of any one complete cycle shall not exceed 120 h.
On completion of the eight temperature cycles, the body shall be cut into two sections in a manner sufficient to
permit internal examination. Detachment of any protective coating local to the plane of section shall be
disregarded. There shall be no visible signs of corrosion of the metal or detachment, cracking, or bubbling of
any protective coating. There shall be no visible change in the colour of the extinguishing media other than
that resulting from the thermal cycling.
8 © ISO 2008 – All rights reserved

---------------------- Page: 12 ----------------------
ISO 11601:2008(E)
NOTE In order to establish reference samples for a change of colour that occurs naturally due to the temperature
changes, two samples of the extinguishing medium shall be stored in closed glass containers and subjected to the same
cycles as the extinguishers.
6.7 Durability test
6.7.1 After being subjected to the series of tests described in 6.7.2 through 6.7.4, a fully charged wheeled
fire extinguisher shall comply with the following:
⎯ not less than 85 % (by weight) of the rated capacity of the extinguishing medium shall be discharged as
intended;
⎯ the wheels, axles, and carriage assembly shall not be damaged to the extent of impairing mobility by one
person;
⎯ no weld shall be broken;
⎯ the dip tube shall not become dislodged.
6.7.2 Durability shall be evaluated by:
⎯ being pushed or pulled for 8 km at the rate of 8 km/h to 13 km/h over a rough surface;
NOTE A surface of crushed stone, nominal size of 18 mm or equivalent, is considered a rough surface.
⎯ being dropped three times onto a concrete surface from a 300 mm high platform so as to land on the
wheels;
⎯ being pulled at a speed of 8 km/h and allowing one wheel to strike a vertical wall of concrete, steel, or
brick; and
⎯ being pushed over so as to land on the bumper or towing handle.
6.7.3 Drop the nozzle of a wheeled extinguisher, as attached to the hose, three times onto a concrete
surface from a height of 900 mm. The assembly is to be dropped in a random manner so that no effort is
made to cause any part of the nozzle, such as the tip or handle, to initially strike the concrete surface.
6.7.4 A wheeled fire extinguisher, when placed in its intended storage position on a flat concrete surface,
shall be self-supporting, stable, able to return to the storage position when displaced from its vertical position
by 10° and operable.
6.8 Electrical conductivity of extinguisher discharge
6.8.1 Requirement
Water-based wheeled fire extinguishers that are marked as being suitable for use on fires involving energized
electrical equipment shall not pass a current of more than 0,5 mA when tested as described in 6.8.2.
6.8.2 Procedure used to test for electrical conductivity
Hang a metal plate, of dimensions (1 m × 1 m) ± 25 mm, vertically from insulating supports. Connect the plate
to a transformer so that an alternating voltage of (36 ± 3.6) kV is established between the plate and earth. The
impedance of the circuit should be such that when a voltage equal to 10 % of the normal primary voltage is
applied to the primary, and the secondary is short circuited, the current in the secondary is not less than
0,1 mA.
Mount the extinguisher on an insulating support with the nozzle fixed 1 m from the centre of the plate, at right
angles to it and directed towards it. Connect the extinguisher to earth. In the case of an extinguisher with a
© ISO 2008 – All rights reserved 9

---------------------- Page: 13 ----------------------
ISO 11601:2008(E)
hose, connect it to earth by connection at the nozzle or in the case of an extinguisher not fitted with a hose, by
connection at the handle.
Measure any current flowing between the extinguisher and earth when the plate is live and the extinguisher
discharging.
7 Fire performance tests
7.1 Suitability for the various classes of fire
7.1.1 Class A. The rating of wheeled fire extinguishers recommended as suitable for Class A fires shall be
determined using the method of 7.2. The rating shall be that of the maximum fire size extinguished under the
conditions of the test.
7.1.2 Class B. The rating of extinguishers recommended as suitable for Class B fires shall be determined
using the method of 7.3. The rating shall be that of the maximum fire size extinguished under the conditions of
the test.
7.1.3 Class C. There are no test requirements for the performance of extinguishers against Class C fires
included in this International Standard. Suitability for use against Class C fires may be claimed for Class AB or
B powder-based extinguishers only.
7.1.4 Class D. Wheeled extinguishers recommended as suitable for Class D fires shall comply with 7.4.
NOTE Extinguishers suitable for Class D fires are not usually also suitable for use on fires of other classes.
Specialized media and applicators are typically used.
7.2 Class A fire tests
Wheeled fire extinguisher intended for use on Class A fires shall be tested for a minimum Class A fire rating of 4-A
using the Class A rating system specified in ISO 7165.
7.3 Class B fire tests
Wheeled fire extinguishers intended for use on Class B fires shall be tested for a Class B fire rating using the
Class B rating system specified in ISO 7165.
NOTE A method of rating wheeled extinguishers for Class B ratings greater than 144B based upon discharge
characteristics and fire tests not exceeding 144B is under development.
7.4 Class D fire tests
The extinguishment of fires should be carried out using a portable extinguisher in accordance with ISO 7165.
There are no numerical components for Class D ratings. The type of combustible metal for which the
extinguisher is applicable and the area, depth and other characteristics of the fire which may be controlled and
extinguished are to be summarized on the extinguisher nameplate and described in the manufacturer’s
installation instructions.
Since wheeled fire extinguishers have a greater charge, they may be classified for use on a proportionally
larger quantity and/or surface area of Class D combustible metals without repeating the Class D fire tests.
10 © ISO 2008 – All rights reserved

---------------------- Page: 14 ----------------------
ISO 11601:2008(E)
8 Construction requirements
8.1 General requirements
8.1.1 The test shall be carried out on a minimum of three extinguisher bodies. For stored pressure
extinguishers, the pressure shall be determined immediately after conditioning each extinguisher at
(60 ± 3) °C for 18 h. The highest of the pressures is designated P . For cartridge or cylinder operated type
ms
extinguishers, after conditioning at (60 ± 3) °C for 18 h, the cartridge or cylinder shall be immediately activated,
and the highest pressure recorded as P .
ms
8.1.2 It shall be verified that, during the temperature conditioning specified in 8.1.1, there is no leakage from
the extinguisher, gas cartridge or cylinder.
8.1.3 The manufacturer shall take the necessary steps to ensure that welds show continuous penetration
with no deviation in the weld. Welds and brazed joints shall be free from defects which are prejudicial to the
safe use of the cylinder or cartridge. The manufacturer shall use welders, welding operators and welding
procedures which can be demonstrated to be suitable for the purpose.
NOTE Users of this International Standard should consider the use of conformity assessment methods relevant to
the needs of this International Standard. Certification by an independent third party can provide a higher level of
confidence in the conformity of products, people and processes.
8.1.4 Parts attached to the body of the cylinder shall be manufactured and fitted in a way that minimizes
concentrations of stress and corrosion risks. In the case of welded and brazed parts, the metal shall be
compatible with the cylinder material.
8.1.5 The cylinder manufacturer shall obtain the works certificate for the cast analysis of material supplied
and shall keep this available for inspection.
8.1.6 Consideration shall be given to avoid the possibility of cross threading plastic components i
...