Cryogenic vessels - Valves for cryogenic service

This European Standard specifies the requirements for the design, manufacture and testing of valves for cryogenic service, i.e. for operation with cryogenic fluids (as defined in EN 1251-1) below - 10 °C as well as at ambient conditions to allow for start-up and run-down. It specifies additional requirements for cryogenic service for the appropriate valve product standard.
NOTE   a cryogenic fluid (refrigerated liquefied gas) is a gas which is partially liquid because of its low temperature (including totally evaporated liquids and supercritical fluids).
It applies to sizes up to DN 150 including vacuum jacketed cryogenic valves.
This European Standard is not applicable to safety valves and valves for liquefied natural gas (LNG).
It is intended that the valve be designed and tested to satisfy a pressure rating (PN or Class). Valves may then be selected with a PN or Class equal to or greater than the maximum allowable pressure (PS) of the equipment with  which it is to be used.

Kryo Behälter - Absperrarmaturen für tiefkalten Betrieb

Diese Europäische Norm legt die Anforderungen an die Konstruktion, Herstellung und Prüfung von Absperrarmaturen für den Kryo-Betrieb fest, d. h. für den Betrieb mit tiefkalten Fluiden unter –10 °C (definiert nach EN 1252 1), wobei der Betrieb unter Umgebungsbedingungen einbezogen wird, um das Aktivieren und Deak¬tivieren (Hoch  und Hinunterfahren) zu berücksichtigen. Für die jeweiligen Armatur Produktnor¬men werden zusätzliche Anforderungen an den Kryo-Betrieb festgelegt.
ANMERKUNG   Ein tiefkaltes Fluid (tiefgekühltes verflüssigtes Gas) ist ein Gas, das wegen seiner niedrigen Temperatur teilweise flüssig ist (total verdampfte Flüssigkeiten und überkritische Fluide sind einbezogen).
Diese Europäische Norm gilt für Nennweiten bis DN 150 und auch für vakuum isolierte tiefkalte Absperrarmaturen.
Sie gilt nicht für Sicherheitsarmaturen und Absperrarmaturen für verflüssigtes Erdgas (eng.: liquified natural gas – LNG).
Es ist vorgesehen, die Armaturen so zu bemessen und zu prüfen, dass sie einer Druckstufe (PN oder Class) entsprechen. Die Armaturen dürfen dann nach einem Nenndruck PN oder einer Class ausgewählt werden, der/die gleich oder größer als der maximal zulässige Druck (PS) der Anlage ist, in der sie eingesetzt werden.

Récipients cryogéniques - Robinets pour usage cryogénique

La présente Norme européenne spécifie les prescriptions relatives à la conception, à la fabrication et aux
essais des robinets pour usage cryogénique c'est-à-dire destinés à fonctionner avec des fluides cryogéniques
(tels que définis dans l’EN 1251-1) à une température inférieure à -10 °C ainsi qu'à une température ambiante
pour permettre le démarrage et l'arrêt de l'installation qu'ils équipent. Elle spécifie les prescriptions
supplémentaires pour usage cryogénique par rapport aux normes appropriées de robinets.
NOTE Un fluide cryogénique (gaz liquéfié réfrigéré) est un gaz partiellement liquide en raison de sa basse
température (liquides totalement évaporés et fluides supercritiques inclus).
Elle s’applique aux robinets cryogéniques dont le diamètre nominal DN n’excède pas 150 et aux robinets
cryogéniques isolés sous vide.
La présente Norme européenne ne s’applique pas aux soupapes de sécurité ni aux robinets pour gaz naturel
liquéfié (GNL).
Il est prévu que le robinet soit conçu et soumis à l’essai pour satisfaire une pression nominale (PN ou classe).
Les robinets peuvent ensuite être choisis avec une pression nominale ou classe supérieure ou égale à la
pression maximale admissible (PS) de l’équipement avec lequel ils sont utilisés.

Kriogene posode - Ventili za kriogeno področje

General Information

Status
Published
Publication Date
23-Feb-2009
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
20-Feb-2009
Due Date
27-Apr-2009
Completion Date
24-Feb-2009

Relations

Buy Standard

Standard
EN 1626:2009
English language
12 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Kryo Behälter - Absperrarmaturen für tiefkalten BetriebRécipients cryogéniques - Robinets pour usage cryogéniqueCryogenic vessels - Valves for cryogenic service23.060.01Ventili na splošnoValves in general23.020.40Proti mrazu odporne posode (kriogenske posode)Cryogenic vesselsICS:Ta slovenski standard je istoveten z:EN 1626:2008SIST EN 1626:2009en,fr,de01-april-2009SIST EN 1626:2009SLOVENSKI
STANDARDSIST EN 1626:20011DGRPHãþD



SIST EN 1626:2009



EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 1626November 2008ICS 23.020.40; 23.060.01Supersedes EN 1626:1999
English VersionCryogenic vessels - Valves for cryogenic serviceRécipients cryogéniques - Robinets pour usagecryogéniqueKryo Behälter - Absperrarmaturen für tiefkalten BetriebThis European Standard was approved by CEN on 13 September 2008.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2008 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 1626:2008: ESIST EN 1626:2009



EN 1626:2008 (E) 2 Contents Foreword . 3 1 Scope . 4 2 Normative references . 4 3 Terms and definitions . 5 4 Requirements. 5 5 Testing . 7 6 Cleanliness . 9 7 Marking . 9 Annex A (informative)
Recommended methods for leak tightness testing of cryogenic valves . 10 Annex ZA (informative)
Relationship between this European Standard and the Essential Requirements of EC Directive 97/23/EC (PED) . 12
SIST EN 1626:2009



EN 1626:2008 (E) 3
Foreword This document (EN 1626:2008) has been prepared by Technical Committee CEN/TC 268 “Cryogenic vessels”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by May 2009, and conflicting national standards shall be withdrawn at the latest by May 2009. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights. This document will supersede EN 1626:1999. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s). For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of this document. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom.
SIST EN 1626:2009



EN 1626:2008 (E) 4 1 Scope This European Standard specifies the requirements for the design, manufacture and testing of valves for cryogenic service, i.e. for operation with cryogenic fluids below - 10 °C as well as at ambient conditions to allow for start-up and run-down. It specifies additional requirements for cryogenic service for the appropriate valve product standard. NOTE a cryogenic fluid (refrigerated liquefied gas) is a gas which is partially liquid because of its low temperature (including totally evaporated liquids and supercritical fluids).
It applies to sizes up to DN 150 including vacuum jacketed cryogenic valves. This European Standard is not applicable to safety valves and valves for liquefied natural gas (LNG). It is intended that the valve be designed and tested to satisfy a pressure rating (PN or Class). Valves may then be selected with a PN or Class equal to or greater than the maximum allowable pressure (PS) of the equipment with which it is to be used. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 19, Industrial valves - Marking of metallic valves EN 736-1, Valves - Terminology - Part 1: Definition of types of valves EN 736-2, Valves - Terminology - Part 2: Definition of components of valves EN 736-3, Valves - Terminology - Part 3: Definition of terms EN 1092-1, Flanges and their joints - Circular flanges for pipes, valves, fittings and accessories, PN designated - Part 1: Steel flanges EN 1251-1, Cryogenic vessels - Transportable vacuum insulated vessels of not more than 1000 litres volume – Part 1: Fundamental requirements EN 1252-1, Cryogenic vessels - Materials - Part 1: Toughness requirements for temperatures below - 80 °C EN 1333, Flanges and their joints - Pipework components - Definition and selection of PN EN 1759-1, Flanges and their joint – Circular flanges for pipes, valves, fittings and accessories, Class designated – Part 1: Steel flanges, NPS ½ to 24 EN 1797, Cryogenic vessels - Gas/material compatibility
EN 12266-1, Industrial valves - Testing of valves - Part 1: Pressure tests, test procedures and acceptance criteria - Mandatory requirements EN 12266-2, Industrial valves - Testing of valves - Part 2: Tests, test procedures and acceptance criteria - Supplementary requirements EN 12300, Cryogenic vessels - Cleanliness for cryogenic service EN 12516-1, Industrial valves – Shell design strength – Part 1: Tabulation method for steel valve shells EN 12516-2, Industrial valves - Shell design strength - Part 2: Calculation method for steel valve shells EN 12516-4, Industrial valves – Shell design strength – Part 4: Calculation method for valve shells manufactured in metallic materials other than steel SIST EN 1626:2009



EN 1626:2008 (E) 5 EN ISO 6708, Pipework components - Definition and selection of DN (nominal size) (ISO 6708:1995) 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 736-1, EN 736-2 and EN 736-3, and the following apply. 3.1 nominal size (DN) defined in accordance with EN ISO 6708 3.2 pressure rating
either nominal pressure (PN) as defined in accordance with EN 1333 and EN 1092-1 or Class rating as defined in EN 1759-1 3.3 specified minimum temperature lowest temperature the valve is specified for 3.4 valve category A valves intended to be operated with normal frequency (above 20 cycles a year)
3.5 valve category B valves intended to be operated only occasionally i.e. with a frequency below 20 cycles a year
4 Requirements 4.1 Materials 4.1.1 Metallic materials Metallic materials to be used in the construction of cryogenic valves shall be suitable for general valve uses as defined in EN 12516-1, EN 12516-2 and EN 12516-4. In addition, the following requirements apply: 4.1.1.1 Toughness requirements Materials which exhibit a ductile/brittle transition shall have minimum impact test values specified in EN 1252-1. These requirements apply only to the critical parts of the valve exposed to cryogenic temperatures (and not to control elements for example). Non ferrous materials which can be shown to have no ductile/brittle transition do not require additional impact tests. 4.1.1.2 Corrosion resistance Materials shall be resistant to or protected from normal atmospheric corrosion and to the medium handled. 4.1.1.3 Oxygen compatibility If the specified minimum temperature is equal to or below the boiling point of air (approximately – 190 °C at atmospheric pressure) or the valve is intended for oxygen service the materials which are, or likely to be, in contact with oxygen or an oxygen enriched air shall be oxygen compatible in accordance with EN 1797.
4.1.1.4 Flammable gas compatibility For hydrogen service, see EN 1797. SIST EN 1626:2009



EN 1626:2008 (E) 6 Copper alloys less than 70 % of copper shall be used for fluids containing acetylene. 4.1.2 Non metallic materials Non metallic materials to be used in packing, seats and glands shall: - have mechanical properties which will allow the valves to pass the sample valve test for category A valves as defined in this standard (see 5.2); - be oxygen compatible, if applicable, see 4.1.1.3. If non metallic materials are used for structural parts, their suitability shall be proven. 4.2 Design 4.2.1 General The valves shall fulfil their function in a safe manner within the temperature range from + 65 °C to their specified minimum temperature and the pressure range intended for use. 4.2.2 Packing gland Valves can have an extended stem. The length of the extension shall be sufficient to maintain the stem packing at a temperature high enough to permit operation within the normal temperature range of the packing material. Valves without an extended stem shall have a stem packing capable of operating at the specified minimum temperature. The handle shall be designed to remain operable for the duration of the sample valve test in accordance with 5.2.3.2. Gland designs incorporating a gland nut with a male or female thread shall be such that the nut shall not unscrew unintentionally, for example when the valve is operated. 4.2.3 Operating positions Valves with an extended stem shall be capable of operation with the valve stem at any position from the vertical to 25° above the horizontal. 4.2.4 Trapped liquid Cavities where liquid can be trapped and build up detrimental pressures due to evaporation or expansion of the liquid during warming up of the valve are not permitted. NOTE For ball and gate valves this requirement can be met by the provision
...

Questions, Comments and Discussion