IEC 60352-6:2022 This part of IEC 60352 is applicable to insulation piercing connections made with stranded wires and tinsel wires, insulated flat conductors and flat flexible circuitries for use in electrical and electronic equipment.
Information on materials and data from industrial experience is included in addition to the test procedures to provide electrically stable connections under prescribed environmental conditions.
The object of this document is to:
determine the suitability of insulation piercing connections under specified mechanical, electrical, and atmospheric conditions;
provide a means of comparing test results when the tools used to make the connections, if any, are of different designs or manufacture.

  • Standard
    70 pages
    English and French language
    sale 15% off

IEC 60352-7:2020 is available as IEC 60352-7:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60352-7:2020 is applicable to spring clamp connections made with stripped wire without further preparation:
- solid conductors of 0,32 mm to 3,7 mm nominal diameter (0,08 mm2 to 10 mm2 cross‑section), or
- stranded conductors of 0,08 mm2 to 10 mm2 cross-section, or
- flexible conductors of 0,08 mm2 to 10 mm2 cross-section,
according to IEC 60228 or IEC 60189-3 for use in electrical and electronic equipment and components.
Information on materials and data from industrial experience is included in addition to the test procedures to provide electrically stable connections under prescribed environmental conditions. The object of this document is to determine the suitability of spring clamp connections under specified mechanical, electrical and atmospheric conditions. This second edition cancels and replaces the first edition of IEC 60352-7, published in 2002. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) correction of the two flow charts in Figure 6 and Figure 7,
b) split the content into more clauses for better separation between full test schedule and basic test schedule,
c) relocating the content of former Clause 6 Practical guidance into an informative Annex A, as now common in the IEC 60352 series for solderless connections,
d) clarification on conductor types with reference to classes defined in IEC 60228.

  • Standard
    30 pages
    English language
    sale 15% off
  • Standard
    65 pages
    English and French language
    sale 15% off

IEC 60352-5:2020 is applicable to solderless press-in connections for use in electrical and electronic equipment and components.
The press-in connection consists of a termination having a suitable press-in zone which is inserted into a hole of a board.
Information on materials and data from industrial experience is included in addition to the test procedures to provide electrically stable connections under specified environmental conditions.
The object of this document is to determine the suitability of press-in connections under mechanical, electrical and atmospheric conditions as specified by the manufacturer of the press-in termination and to provide a means of comparing test results when the tools used to make the connections are of different designs or manufacture.
This fifth edition cancels and replaces the fourth edition published in 2012. This edition constitutes a technical revision.
This edition includes the following significant changes with respect to the previous edition:
a) revising the scope by removing the wording "… telecommunication equipment and in electronic devices employing similar techniques" and replacing it by "… electrical and electronic equipment and components" in the first paragraph;
b) adding terms and definitions for 'board', 'hole' and 'metal board' to recognize that press-in terminations are being used in many non-printed board materials;
c) editorial changes to clarify the difference between the two test schedules for qualification and application;
d) modification of upper limit of copper thickness of the plated-through-hole to reflect actual market trends and manufacturing practices;
e) removal of bending test, as this test is very specific for applications of press-in technology no longer common;
f) adding graphs to document the press-in and push-out force, since this is common testing practice and provides further insight into mechanical performance of the contact zone;
g) reducing the number of test specimens required, since in previous testing scheme a lot of test samples were discarded;
h) new wording in 4.5 for cracked and bent terminations;
i) added Figure 7b to show V and A connection locations when the press-in termination does not protrude through the bottom side of the board.

  • Standard
    34 pages
    English language
    sale 15% off
  • Standard
    69 pages
    English and French language
    sale 15% off

IEC 60352-4:2020 is applicable to non-accessible ID connections for which the tests and measurements according to Clauses 6 through 8 are suitable and which are made with:
– appropriately designed ID terminations;
– wires having solid round conductors of 0,25 mm to 3,6 mm nominal diameter;
– wires having stranded conductors of 0,05 mm2 to 10 mm2 cross-sectional area;
for use in electrical and electronic equipment and components.
Information on materials and data from industrial experience is included in addition to the test procedures to provide electrically stable connections under prescribed environmental conditions.
There are different designs and materials for ID terminations in use. For this reason, only fundamental parameters of the termination are specified, while the performance requirements of the wire and the complete connection are specified in full detail.
The purpose of this document is:
– to determine the suitability of non-accessible ID connections under specified mechanical, electrical and atmospheric conditions;
– to provide a means of comparing test results when the tools used to make the connections, if any, are of different designs or manufacture.
This second edition cancels and replaces the first edition, published in 1994, and its Amendment 1 (2000). This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) Transferred Clauses 9 to 13 into Annex A (informative).
b) The figures were re-drawn for clarity.

  • Standard
    85 pages
    English and French language
    sale 15% off

IEC 60352-3:2020 is applicable to ID connections which are accessible for tests and measurements according to Clauses 6 through 8 and which are made with:
– appropriately designed accessible ID terminations,
– wires having solid round conductors of 0,25 mm to 3,6 mm nominal diameter,
– wires having stranded conductors of 0,05 mm2 to 10 mm2 cross-sectional area,
for use in electrical and electronic equipment and components.
Information on materials and data from industrial experience is included in addition to the test procedures to provide electrically stable connections under prescribed environmen-tal conditions.
There are different designs and materials for accessible ID terminations in use. For this reason only fundamental parameters of the termination are specified, while the perfor-mance requirements of the wire and the complete connection are specified in full detail.
The purpose of this document is:
– to determine the suitability of accessible ID connections under specified mechanical, electrical and atmospheric conditions;
– to provide a means of comparing test results when the tools used to make the con-nections, if any, are of different designs or manufacture.
This second edition cancels and replaces the first edition published in 1993. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the pre-vious edition:
a) Subclause 7.2.2: reduce the limit of duration of contact disturbance to 1 µs.
b) Subclause 7.2.3: reduce the limit of duration of contact disturbance to 1 µs.
c) Transferred Clauses 9 to 13 to Annex A (informative).
d) The figures were revised for clarity.

  • Standard
    81 pages
    English and French language
    sale 15% off

IEC 60352-5:2012 is applicable to solderless press-in connections for use in telecommunication equipment and in electronic devices employing similar techniques. The press-in connection consists of a termination having a suitable press-in zone which is inserted into a plated-through hole of a double-sided or multilayer printed board. Information on materials and data from industrial experience is included in addition to the test procedures to provide electrically stable connections under prescribed environmental conditions. The object of this part of IEC 60352 is to determine the suitability of press-in connections under mechanical, electrical and atmospheric conditions as specified by the manufacturer of the press-in termination and to provide a means of comparing test results when the tools used to make the connections are of different designs or manufacture. This fourth edition cancels and replaces the third edition published in 2008. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- enhancement of Annex A and further application remarks are added;
- editorial changes throughout the standard to prevent the document from being misunderstood as specification for establishing press-in connection in total;
- deletion of all tables with hole dimensions. Historically the hole dimensions were constrained because of the dimensions of the wire wrap and clip connections posts. Since these connection technologies are no longer commonly used, the design requirements are no longer practical;
- inclusion of additional figures and one table in 4.4.4 to define tolerance ranges for holes in test-boards and to illustrate them;
- inclusion of a requirement for the thickness of the test-board in 4.4. The contents of the corrigendum of September 2014 have been included in this copy.

  • Standard
    66 pages
    English and French language
    sale 15% off

IEC 60352-8:2011 Is applicable to compression mount connections with metallic spring contacts for use in telecommunication equipments and in other electronic devices employing similar techniques. Information on materials and data from industrial experience are included in addition to the test procedures to provide electrically stable connections under prescribed environmental conditions. The object of this part of IEC 60352 is to determine the suitability of compression mount connections under specified electrical, mechanical and atmospheric conditions and to provide a means of comparing test results when the tools used to make the connectors are of different designs or manufacture.

  • Standard
    41 pages
    English and French language
    sale 15% off

Determines the suitability of solderless crimped connections under specified mechanical, electrical and atmospheric conditions and provides a means of comparing test results when the tools used to make the connections are of different designs or manufacture.

  • Standard
    111 pages
    English and French language
    sale 15% off

Determines the suitability of spring-clamp connections under specified mechanical, electrical and atmospheric conditions. Is applicable to spring-clamp connections made with stripped wire without further preparation.

  • Standard
    51 pages
    English and French language
    sale 15% off

Determines the suitability of insulation piercing connections under specified mechanical, electrical and atmospheric conditions, and provides a means of comparing test results when the tools used to make the connections are of different design.

  • Standard
    53 pages
    English and French language
    sale 15% off

Determines the suitability of wrapped connections under specified mechanical, electrical and atmospheric conditions, and provides a means of comparing test results when the tools used to make the connections are of different design. The contents of the corrigendum of October 1998 have been included in this copy.

  • Standard
    61 pages
    English and French language
    sale 15% off